Abstract
Tumor oxygenation (pO2), acidosis (pH) and interstitial inorganic phosphate concentration (Pi) are important parameters of the malignant behavior of cancer. A noninvasive procedure that enables visualization of these parameters may provide unique information about mechanisms of tumor pathophysiology and provide clues to new treatment targets. In this research, we present a multiparametric imaging method allowing for concurrent mapping of pH, spin probe concentration, pO2, and Pi using a single contrast agent and Overhauser-enhanced magnetic resonance imaging technique. The developed approach was applied to concurrent multifunctional imaging in phantom samples and in vivo in a mouse model of breast cancer. Tumor tissues showed higher heterogeneity of the distributions of the parameters compared with normal mammary gland and demonstrated the areas of significant acidosis, hypoxia, and elevated Pi content.
Similar content being viewed by others
Introduction
Solid tumors develop a tissue microenvironment profile significantly different from parent healthy tissue. Tissue oxygenation (pO2), interstitial pH, and inorganic phosphate (Pi) levels are important markers of tumorigenic activity1,2,3,4,5. Magnetic resonance techniques are widely used to study cancer in both preclinical animals model and clinical set-ups. Magnetic resonance imaging (MRI) is one of the most successful techniques for anatomical tissue characterization, including tumor neoplasm detection. Moreover, MRI can be applied for measurements and mapping of oxygen6,7,8,9, pH10,11,12, and inorganic phosphate13,14 using both endogenous and exogenous molecular probes. In contrast to MRI, electron paramagnetic resonance (EPR) techniques are unsuitable for anatomical tissue characterization because of strict reliance on exogenous probes. However, EPR techniques have found multiple applications in various analyte detection, including pO2 15,16,17,18, pH18,19,20,21, and Pi4. The major advantage of EPR techniques over MRI is multifunctionality of tissue parameter detection20,21,22,23,24. The double resonance imaging technique, Overhauser MRI (OMRI), combines advantages of both approaches allowing for concurrent anatomical tissue imaging and multifunctional mapping of tissue physiological parameters25,26,27,28,29. In OMRI, saturation of spin probe EPR transition by powerful radiofrequency irradiation results in polarization transfer from electron to nuclear spin (water protons in 1H MRI modality) transition levels and corresponding significant enhancement of MRI signal intensity. The variation of EPR saturation power or EPR frequency value allows for measurement of different analytes in solution (e.g., oxygen, pH et cet.)25.
Most OMRI experiments monitor concentrations of spin probes (nitroxide probes, redox-related studies30,31,32,33,34) or oxygenation level (trityl probes26,34,35,36,37). Several attempts were made to use the OMRI technique to map the acidity of tissues and solutions using both nitroxide20,38 and trityl39 probes. Here we present the development of a multifunctional OMRI technique using a monophosphonated trityl probe for concurrent mapping of several functional parameters, namely pO2, pH, Pi, and spin probe concentration.
Results
Concurrent pH, pO2, and Pi and contrast agent concentration measurements
Monophosphonated perdeuterated trityl radical (dpTAM, Fig. 1a) has been used as a multifunctional paramagnetic probe for concurrent measurement of several tissue parameters (pO2, pH, and Pi) in vivo using L-band EPR spectroscopic approaches4,21. dpTAM exhibits a doublet EPR spectrum due to hyperfine splitting on the phosphorus nucleus. dpTAM probe exists in two forms (acidic and basic) at physiological range of pH due to reversible protonation of phosphono group (pK = 6.9). Therefore, four lines are observed in the EPR spectra of dpTAM radical (Fig. 1b) in the pH range from 6 to 8 pH units.
The high frequency component of dpTAM dynamic nuclear polarization (DNP) spectra at acidic (pH = 4), neutral (pH~7) and basic (pH = 10) pH are shown in Fig. 1c. Similar to EPR spectra (Fig. 1b), DNP spectra of the high frequency component are characterized by a singlet in acidic and basic solutions and a doublet at neutral pH. The ratio of enhancement factors of protonated, \({E}_{RH}^{457}\), and deprotonated, \({E}_{R}^{456.6}\), forms strongly depends on pH value (see Fig. 2a) and can be described by a standard titration curve39 (see Eq. (4), Methods Section) with pK value equal to 6.88 in agreement with published data4,21. pH titration of the dpTAM probe was performed at different conditions, as shown in Fig. 2a,c. It was found that the titration curve shape significantly depends only on irradiation power level (Fig. 2a,b) while the influence of pO2, Pi and contrast agent concentration (C) is negligible in the range of pH 6.4–7.4 (Fig. 2c), therefore allowing pH mapping independently of pO2, Pi and C parameters.
The mapping of pO2 values and contrast agent concentration using OMRI techniques are well documented for single line EPR trityl probes24,26,29,35. However, the multifunctional dpTAM trityl probe high frequency component of the DNP spectrum consists of two partially overlapped spectral components (see Fig. 1d). The semi-empirical mathematical description was developed to correctly describe the dependences of enhancement factor values on oxygen level and contrast agent concentration. Conventional Overhauser enhancement equations were modified by introducing the overlap factors (see Eqs (1a) and (1b), Methods Section) to describe a spectral lines overlapping effect (see Fig. 1d). The contribution of dpTAM probe Heisenberg spin self-exchange40 and oxygen-dependent polarization leakage24 have been taken into account (see Methods Section for details). The developed approach allows the description of the dependence of enhancement factor values of both deprotonated and protonated forms on irradiation power, C and pO2 independently. The mathematical description was elaborated using a set of 36 experimental dependences acquired at various pH, pO2 and spin probe concentrations.
The developed approach for simultaneous pH, pO2, and C computation was first tested on phantom samples. Figure 3a–f represents the dependencies of enhancement factors, \({E}_{R}^{456.6}\) and \({E}_{RH}^{457}\), on irradiation power at different C, pO2 and pH values. These dependencies were fitted using Eqs (1a) and (1b) yielding the values of spin probe concentration and pO2, while pH values were determined independently using Eq. (4). The calculated values of C, pO2, and pH are listed in Table SI1 (see SI) and are in satisfactory agreement with prepared solution values of C, pO2, and pH.
The chemical reaction of proton exchange of dpTAM probe with inorganic phosphate results in the coalescence of two resonance lines of protonated and deprotonated forms providing a basis for Pi measurements (see Fig. 4a and ref.38). The intensity of the DNP spectrum in the middle point (\({E}_{m}^{456.8}\)) strongly depends on phosphate buffer concentration (see Fig. 4a). On the other hand, enhancements at protonated (\({E}_{RH}^{457}\)) and deprotonated (\({E}_{R}^{456.6}\)) EPR frequencies negligibly depend on Pi in the range 0–4 mM (see Figs S3a,b, SI) allowing for semi-empirical Pi calculation (see Eqs (6) and (7), Methods Section) independently on the values of pH, C, and pO2 as illustrated in Fig. 4b. The ratio, \({E}_{m}^{456.8}/({E}_{R}^{456.6}+{E}_{RH}^{457})\), measured at different Pi values was normalized on its maximum value at infinite power to reduce the experimental error of enhancement measurement. The normalized ratio dependences on irradiation power were fitted by Eq. (6) (see Methods Section) yielding the calculated Pi concentration values in satisfactory agreement with the prepared ones (see Fig. 4b).
Multiparametric phantoms imaging
To demonstrate the feasibility of simultaneous imaging of multiple parameters, we performed OMRI measurements of several phantom samples to generate 2D maps of C, pO2, pH, and Pi distributions. In total, mapping of these four parameters requires the acquisition of six OMRI images performed at two EPR powers and three frequencies of EPR irradiation. Note that collection of a conventional MRI (EPR-off) image is required for calculation of all parameters. Figure 5 represents 2D functional maps and corresponding histograms of parameter distributions for three different phantoms of four glass vials filled with dpTAM solutions with different C, pO2, pH, and Pi values listed in Table 1. As seen in Table 1, the calculated values are in a reasonable agreement with prepared ones.
Multiparametric imaging of normal mouse mammary gland and breast cancer tumor
Concurrent multiparametric imaging of the tissue microenvironment of normal mammary gland performed in anesthetized FVB/N wild type mouse yields C, pO2, pH, and Pi maps, as shown in Fig. 6a–d. Functional maps were superimposed with MRI image. The mean parameters values and their standard deviations are equal to 1.0 ± 0.4 mM, 53 ± 6 mmHg, 7.00 ± 0.06, 0.9 ± 0.4 mM for C, pO2, pH and Pi maps, correspondingly.
Multiparametric imaging of the tissue microenvironment of breast cancer tumor performed in MMTV-PyMT transgenic mouse yields functional maps shown in Fig. 6e–h. The mean parameters values for C, pO2, pH and Pi maps, and their standard deviations are equal to 0.6 ± 0.2 mM, 32 ± 7 mmHg, 6.7 ± 0.1, 1.8 ± 0.9 mM, correspondingly.
Identical experiments were performed on sets of animals; the total number of mice was 7 and 4 for experiments with healthy mammary gland and tumors, respectively. All obtained multiparametric imaging data and corresponding mean values are presented in SI. Figure 7 shows pO2, pH, and Pi histograms for data combined from all images. Histograms were fitted by normal distributions yielding the following mean values of pO2, pH and Pi and their standard deviations: 27 ± 4 and 34 ± 11 mmHg (tumor pO2 distribution is a mixture of two normal distributions), 6.86 ± 0.15 and 2.0 ± 0.8 mM in the case of tumor tissue; 45 ± 10 mmHg, 7.15 ± 0.14 and 1.3 ± 0.3 mM in the case of mammary gland tissue.
In a separate experiment, the pharmacokinetics of the dpTAM probe was studied in healthy and tumor-bearing mice. The disappearance of dpTAM signal from a tumor or mammary gland was accompanied by the appearance of dpTAM signal in the mouse bladder (see Fig. S15, SI). The characteristic time (half of signal intensity change) of dpTAM wash out from tissues was calculated to be equal to 26 min for tumor and 43 min for mammary gland. The characteristic time of dpTAM signal accumulation in the bladder was found to be in the range 34–40 min and 58–78 min for tumor and mammary gland, correspondingly.
Discussion
Noninvasive in vivo multifunctional mapping of tumor microenvironment (TME) parameters such as pO2, pH and Pi may provide a unique insight into understanding mechanisms of tumor pathophysiology and become a useful tool for the development of new therapeutic approaches. However, in the present time, there are no available techniques for concurrent imaging of these parameters. In this work, we present a multiparametric imaging method for concurrent visualization of spin probe concentration, pO2, extracellular pH, Pi, and anatomical structure using single contrast agent and OMRI technique.
Recently, we designed a monophosphonated trityl spin probe, dpTAM (see Fig. 1a) with EPR spectrum possessing unique multiple functional sensitivity to pO2, pH, and Pi4,21,38. In our previous work, we employed low-field L-band EPR spectroscopy to monitor these parameters in several mouse models of cancer4. However, EPR spectroscopic approaches still have the disadvantage of reporting the average values of the TME parameters and does not allow assessing their spatial distribution in tumors characterized by high heterogeneity. To perform multifunctional mapping using a dpTAM probe, we develop an OMRI approach that acquires set of images at different EPR irradiation powers and different EPR frequencies. A minimal number of image acquisitions required for extracting pO2, pH, Pi, and probe concentration has been justified by testing in vitro using phantom samples. Maps of functional parameters have been calculated using the semi-empirical mathematical description of experimental data. The developed OMRI approach allows for multiparametric mapping using six OMRI images obtained at three frequencies and two powers of EPR irradiation. Also a conventional MRI (EPR-off) image has to be collected to retrieve anatomical information and the base level of NMR signal intensity.
Previously, several attempts were performed using OMRI technique to map the acidity using nitroxide20 or trityl spin probes39. It has been shown that pH mapping can be performed using two OMRI images obtained at irradiation frequencies of protonated and deprotonated forms of pH-sensitive contrast agent. We performed the pH titration of the dpTAM probe and observed dependence of titration curve shape on irradiation power while the influence of pO2, Pi and contrast agent concentration (C) was insignificant in the range of pH 6.4–7.4 (see Fig. 2a–c). Therefore, in physiological ranges of functional parameters, pH from 6.4 to 7.4, pO2 from 0 to 80 mmHg, and Pi from 0 to 4 mM, the values of pH can be calculated using only two OMRI images acquired at two different EPR frequencies. The maximum error caused by simplification of titration curve description reaches 0.1 pH units at the edges of considered pH range. Note that the collection of naive MRI images is not required for pH assessment.
Trityl radicals with a single line EPR/DNP spectrum were applied for pO2 imaging using OMRI technique24,26,29,35. The theoretical foundation for these measurements shows that the collection of two OMRI images obtained at two different irradiation powers and one naive MRI (EPR-off) image is sufficient for pO2 and contrast agent concentration determination. In the case of the dpTAM spin probe, pO2 measurements can be performed independently using both protonated and deprotonated forms of a probe which potentially increases the accuracy of the pO2 determination. Thereby, contrast agent concentration and pO2 mapping can be performed using four OMRI images acquired at two EPR pumping powers at two frequencies of protonated and deprotonated forms of the dpTAM probe. Note that the collection of a naive MRI image is required.
The presented approach for Pi mapping requires OMRI acquisition at frequencies of protonated and deprotonated forms, and at the mid-point frequency most sensitive to the Pi (see Fig. 4a), each at two powers of EPR irradiation. Therefore, multiparametric C, pO2, pH, and Pi imaging can be performed using six OMRI images and one EPR-off MRI image.
Practically, the application of the developed approach is limited by contrast agent concentration in the range below 2 mM due to the significant contribution of Heisenberg spin self-exchange at high dpTAM probe concentration in the exchange process. High contrast agent concentration results in a high rate of proton exchange between protonated and deprotonated forms of dpTAM38, which significantly complicates the discrimination between Pi- and self-exchange contributions.
The developed theoretical semi-empirical foundation allows us to describe the enhancement factors \({E}_{R}^{456.6}\) and \({E}_{RH}^{457}\), their ratios \(({E}_{R}^{456.6}+1)/({E}_{R}^{456.6}+{E}_{RH}^{457}+2)\) and \({E}_{m}^{456.8}/({E}_{R}^{456.6}+{E}_{RH}^{457})\), as functions of irradiation power, C, pO2, pH, and Pi (see Methods Section for details). The developed approach was successfully applied for simultaneous C, pO2, pH (see Fig. 3a–f), and independent Pi calculations (see Fig. 4b). Multiparametric imaging was performed using three different phantom samples. Figure 5 shows examples of concurrent pO2 and pH, pO2 and C, pO2, and Pi imaging. These experiments show that solving of the multiparameter problem is accompanied by broadening of parameters distribution due to the accumulation of errors. Nevertheless, all calculated parameters are normally distributed and their standard deviation values (see Table 1) are in an acceptable range.
After successful imaging experiments with phantom samples, we performed in vivo experiments in mouse normal mammary glands and breast tumors. Figure 6a–d represents maps of functional parameters in mammary gland tissue. Images clearly show uniform distribution of high pO2, neutral pH, and low Pi values in the region of interest. Concurrent multiparametric mapping of tumor tissue is shown in Fig. 6e–h. Images of tumor tissues are characterized by: (i) approximate uniform hypoxic area compared to pO2 value of normal tissue; (ii) heterogeneous pH distribution with average pH value significantly lower compared to healthy tissue; (iii) heterogeneous Pi distribution with average Pi value two times higher compared to normal mammary gland. Similar imaging experiments were performed on several normal mammary glands (n = 7) and tumors (n = 4) resulting in the comparable mean values of functional parameters (see Figs S4–S14 and Table SI2). Figure 7 shows pO2, pH, and Pi distribution for combined data sets of normal and tumor tissues. Data were fitted by normal distribution to elicit the mean values and standard deviations (see Fig. 7). Significant differences were identified for two types of tissue. TME oxygen value distribution covers the large variation in values from hypoxic to normoxic areas and can be described by combination of two normal distributions with mean values considerably lower compared to pO2 values in mammary gland tissue. pH value distribution for malignant tissue is significantly shifted by approximately 0.3 pH units (p < 0.05, see Fig. 7) toward acidic values compared with normal mammary gland tissue. Interstitial inorganic phosphate concentration in tumor tissue was found to be 2 times higher compared to healthy mammary gland. This observation emphasizes the importance of Pi as a marker of tumor progression4. Note that the Pi value distribution width in tumors (SD = 0.8 mM) is significantly broader compared to its mammary gland counterpart (SD = 0.3 mM). In contrast, the widths of pH and pO2 distributions are comparable for both tumor and mammary gland tissues. The presented results of these pilot animal studies were found to be in agreement with the values previously measured by L-band EPR spectroscopy4,20 demonstrating capability of the multifunctional OMRI mapping for in vivo studies. The future animal applications of the developed OMRI approach may include investigating relationship between tumor progression and appearance of hypoxic, acidic and high [Pi] areas and correlation between these TME parameters, and may provide new insights into the underlying biochemical mechanisms of tumorigenesis.
The dpTAM trityl probe is a water soluble amphiphilic compound. Its application in vivo is limited by local intratissual delivery due to toxicity of “Finland”-type trityls upon systemic delivery41. Nevertheless, this probe is characterized by low toxicity by local delivery, in part due to negligible doses used under itratissue delivery (100–1000 times lower compared to i.v. delivery). We have observed slow transfer of dpTAM probe (see Fig. S15) from tissue to the bladder due to wash out of probe by blood flow. The characteristic (half-life) time was found to be in the range of 26–43 minutes, which justifies the insignificant change in dpTAM probe concentration over acquisition time of about 4 minutes. Note that we were not able to estimate bladder pO2, pH and Pi content using dpTAM probe due to both the low acidity and high phosphate content of urine.
This work demonstrates a unique capability of the OMRI technique in combination with specially designed trityl spin probe for multiparametric imaging of pH, contrast agent concentration, pO2 and inorganic phosphate concentration in phantom samples, mouse tumors and normal mammary gland tissues. Based on the enhancement of the proton MRI signal after EPR irradiation of paramagnetic probes, OMRI inherently offers a high spatial resolution, plane selectivity, and rapid image data collection. Previously we demonstrated the capability of OMRI for in vivo pH mapping of extracellular pH in tumors in a mouse model of breast cancer using a pH-sensitive imidazoline nitroxide38. Note that OMRI applications benefit from using paramagnetic probes with a narrow line width to obtain a high enhancement and low radio frequency power deposition. In the case of the nitroxide probe, the irradiation-induced body temperature increase measured with the microsensor did not exceed 1 °C38. Trityl probes possess significantly more narrow linewidth (ΔHpp ≈ 40 mG for dpTAM) compared to the nitroxides (ΔHpp ≈ 1.2 G for imidazoline nitroxide38) and at least one order of magnitude longer relaxation times allowing for their easy saturation and application of low specific absorption rates, therefore making them preferable paramagnetic probes for functional in vivo pre-clinical OMRI applications25. The multifunctional monophosphonated trityl probe, dpTAM, used in this work, is applicable for intratissue delivery only due to its interaction with plasma albumin41. Further synthetic work to improve the probe biocompatibility and suitability for systemic delivery is in progress based on two alternative strategies, (i) incorporation of monophosphonate group in core structure of Ox071 trityl probe suitable for systemic delivery15,25; and (ii) conjugation of dpTAM probe with a biocompatible carrier, such as dextran42. In summary, the multifunctional OMRI technique significantly broadens the area of pre-clinical EPR-based applications allowing for mapping and correlation of physiologically-relevant tissue parameters in various disease models of cancers and beyond. Moreover, as an MRI-based approach, multifunctional OMRI has potential for translation into clinical settings upon progress in instrumentation (e.g., in our previous work38 OMRI system based on the whole body 0.38 T clinical scanner was used) and in the development of biocompatible probes.
Methods
Contrast agent
Deuterated phosphonated trityl radical (dpTAM) (see Fig. 1a) used as a paramagnetic multifunctional contrast agent was synthesized according to published procedure21.
OMRI scanner, pulse sequence, and experimental parameters
The OMRI experiments were performed on an OMRI desktop imager (Keller JXI-KC02, Japan Redox Ltd.) using a standard fast spin echo sequence for MRI. Imaging experiments were performed in 2D modality. The scanning conditions for the OMRI experiment were as follows: repetition time (TR) × echo time (TE) × EPR irradiation time (TEPR), 700 × 37 × 500 ms; echo factor, 4; frequencies of EPR irradiation, 456.6, 456.8, 457 MHz; slice thickness, 100 mm for phantom imaging, 4 mm for animal imaging; field of view, 30 × 30 mm2 or 40 × 40 mm2; matrix size, 64 × 64; number of averages was 10 for MRI (EPR-off) images, 2 for OMRI images (for EPR power 8 and 0.25 W) in animal experiments and was varied as 2, 2, 4, 4, 4, 6, 6 for irradiation powers 8, 4, 2, 1, 0.5, 0.25, 0.125 W in experiments with phantom samples. The scanning times of images with two and ten averages were 24 and 114 s, correspondingly. Total time of OMRI + MRI (EPR-off) image set in in vivo experiments 2 EPR powers × 3 EPR frequencies × 24 s + MRI (EPR-off) image = 2 × 3 × 24 + 114 = 4.3 min. MRI detection of 1H water signal was performed on field 0.016 T (0.686 MHz).
Specific absorption rate estimation for OMRI experiment
Specific absorption rate (SAR) was estimated by measurement of the Q-factor of empty and mouse-loaded resonator43. It was found that 23.5% of applied power was absorbed by the mouse body (weight 36 g). Taking into account the duty cycle of the EPR irradiation (500 ms in 700 ms or 71.4%) with two different powers (0.25 and 8 W) the estimated average SAR was 19.2 W·kg−1. A series of six OMRI images were performed over 2.4 minutes by alternating sequences with the high (8 W) and the low (0.25–0.5 W) irradiation powers, each 24 s, to avoid a body heating of the mice. The animal temperature was measured using Nomad Fiber Optic Thermometer (Neoptix, Canada) equipped with Fiber Optic Temperature Sensor with a probe diameter of 0.5 mm, placed on the shaved skin chest area. The measured temperature did not exceed 37 °C during the entire OMRI experiment. All animals were alive until the end of the experiment and placed back to the cage after the end of anesthesia.
Theory and calibration procedures
The enhancement factors for deprotonated and protonated forms are described by equations (see SI for the details):
where indexes R and RH correspond to deprotonated and protonated forms of dpTAM; \({E}_{R}^{456.6}\) and \({E}_{RH}^{457}\) are the enhancement factors of deprotonated and protonated forms measured at their resonance frequencies 456.6 and 457 MHz of the high frequency component of the DNP spectrum (see Fig. 1c); \({E}_{R}^{inf}\) and \({E}_{RH}^{inf}\) are the enhancement factors of deprotonated and protonated forms at infinite power and contrast agent concentration (\({E}_{R,RH}^{inf}=({\gamma }_{S}/{\gamma }_{I})\cdot {\varepsilon }_{R,RH}\), where εR and εRH are the coupling factors, γS and γI are the values of the gyromagnetic ratio of electron and proton); f is the leakage factor; SR,RH is the saturation factor, \({E}_{RH}^{456.6}\) and \({E}_{R}^{457}\) are the overlap factors – the enhancement factors of protonated and deprotonated forms determined at resonance frequencies 456.6 and 457 MHz (see Fig. 1d); P is a power of EPR irradiation. Theoretical details of enhancement factors description are provided in SI.
The leakage factor can be described as following24:
where T10 and T1 are the relaxation times of water protons in the absence and the presence of spin probe, r is a relaxivity constant, \({w}_{l}^{0}\) is oxygen-induced leakage rate constant, f0 is a traditional interpretation of leakage factor, fl a part of the leakage factor which depends on the concentration of the paramagnetic impurity (e.g., oxygen).
The second parameter in enhancement factors descriptions (1a) and (1b) is the saturation factor40:
where a numerical factor \(\frac{1}{2}\) represents a saturation of only high frequency component of the DNP spectrum of the dpTAM probe, α is a resonator efficiency factor measured for each sample in a separate experiment, T1e and T2e are the electron spin relaxation times of the contrast agent, \({f}_{exc}^{R,RH}\) are parameters represented the influence of Heisenberg spin exchange on the shape of the DNP spectrum (self-exchange of dpTAM probe results in ‘preservation’ of spin probe polarization), wexc is the rate constant of spin exchange. A detailed description of parameters \({g}_{R}^{456.6}\), \({g}_{RH}^{457}\), wexc and overlap factors \({E}_{RH}^{456.6}\,\)and \({E}_{R}^{457}\) are provided in SI.
The ratio of enhancement factors of protonated and deprotonated forms strongly depends on pH value and can be described by the standard titration curve38,39:
where Rmax and Rmin are the maximum and minimum values of the titration curve function. The dependences of Rmax and Rmin parameters on irradiation power are described by the following equations (see SI):
where s1, s2, s3, s4 are experimentally calibrated parameters.
The ratio of enhancement factors \({R}_{m}(P)={E}_{m}^{456.8}/({E}_{R}^{456.6}+{E}_{RH}^{457})\), where \({E}_{m}^{456.8}\) is an enhancement factor measured at frequency 456.8 MHz (see Fig. 4a), was used for Pi calculations. The following semi-empirical equation was obtained to describe Rm(P) as function:
where are \({R}_{m}^{max}={R}_{m}(P\to \infty )\) is an Rm value at infinite power, parameters g + and gm are described as follows:
where b0, b1, b2, b3,b4, b5, b6, b7, b8, b9 and b10 are experimentally calibrated parameters.
Descriptions of calibration procedures are provided in SI. All presented data processing procedures were made using specially developed MATLAB code.
Calculation procedure in an imaging modality
Enhancement factors (1a) and (1b) depends on C, pO2, and pH. Parameters C and pO2 were calculated by a finding a numerical solution of the system of four Eqs (1a) and (1b) using two different irradiation powers P1 and P2. (Note that acquisition of third MRI image with no EPR irradiation power is required to calculate the enhancement values). The pH values were calculated solving system of two Eq. (4) at powers P1 and P2, obtained pH values were used as parameters for calculation of contrast agent concentrations and oxygen partial pressures.
Phosphate buffer concentrations, Pi, were calculated using a system of two ratios of enhancement factors \({E}_{m}^{456.8}/({E}_{R}^{456.6}+{E}_{RH}^{457})\) obtained at two powers P1 and P2 and the highest power (P2) equal to 8 W was used for estimation of maximum values \({R}_{m}^{max}\):
where function \({R}_{m}(P)/{R}_{m}^{max}\) is described by Eq. (6), values of parameters C, pO2, and pH were obtained independently by procedure described above and used for Pi calculation as parameters. Systems of equations were solved numerically in each pixel. Only pixels with enhancement factor higher than one were taken into account for calculation of parameter maps. Calculations were made using specially developed MATLAB code.
Phantom samples preparation and imaging
The contrast agent was dissolved in 150 mM NaCl solution for samples preparation. Sample solutions were bubbled for 15 minutes with a gas mixture of nitrogen and oxygen in various proportions to provide desired oxygen concentration. pH values were regulated by the addition of HCl or NaOH. All measurements were performed at 33 °C. All calibration samples were constructed using one 8 mL glass vial filled with 4–5 mL of contrast agent solution and one 8 mL glass vial filled with 150 mM NaCl solution. OMRI data were acquired at irradiation powers 0, 0.125, 0.25, 0.5, 1, 2, 4 and 8 W for calibration experiments and mean data values of OMRI images from regions of interest for were used for further data processing. Imaging phantom samples were constructed using four 2 ml glass vials filled with solutions with various spin probe concentration and pO2, pH, Pi values.
Animals imaging in vivo
All animal work was performed in accordance with the WVU IACUC approved protocol. All experimental procedures were approved by West Virginia University Institutional Animal Care and Use Committee. MMTV-PyMT (polyoma virus middle T antigen) transgenic mice (PyMT+/−) on the FVB/N background (Jackson Laboratories, 002374, FVB/N-Tg (MMTV-PyVT)634Mul/J) which spontaneously-develop breast cancer (4 animals) were used for in vivo experiments. For comparison of tissue microenvironments of normal mammary glands and tumors, age-matched littermate females (7 animals) absent of the PyMT oncogene (PyMT−/−) were used. A stock solution of 5–15 mM contrast agent (pH = 7.1) in 150 mM sodium chloride solution was prepared for injection. Injection solution was bubbled slowly during 30 minutes with a gas mixture of nitrogen and oxygen in proportion 93%/7% to provide faster equilibration of tissue microenvironment after injection. Animals were placed into the OMRI resonator and anesthetized by inhalation of the air-isoflurane mixture using DRE VP3 (DRE veterinary, USA) anesthetic machine. A tube with a gas mixture was connected to the rear side of resonator to provide continuous gas supply during the experiment. After the onset of anesthesia, a 50–100 µl of stock solution of contrast agent was injected locally into mouse mammary gland or breast tumor. Fifteen minutes after injection, one MRI and six OMRI images were acquired at irradiation powers 0.25 (or 0.5) and 8 W and frequencies 456.6, 457, 456.8 MHz. Slice thickness of 4 mm was selected so that only signals from which an area that contrast agent contributed to the enhancement of MRI signal was included. Tumor volume was calculated using 2D MRI image measurements of length (L) and width (W) of tumor and equation, V = [L × W2] × 0.5, where V is tumor volume44.
Statistical analysis
Statistical analysis was performed using the OriginPro software package. To compare two distributions, the ANOVA test (for normally distributed populations) and non-parametric Mann–Whitney U test (for non-normally distributed populations) were used.
Data Availability
The datasets generated and/or analyzed during the current study are available from the corresponding author on reasonable request.
References
McKeown, S. R. Defining normoxia, physoxia and hypoxia in tumours-implications for treatment response. The British journal of radiology 87, 20130676–20130676, https://doi.org/10.1259/bjr.20130676 (2014).
Kato, Y. et al. Acidic extracellular microenvironment and cancer. Cancer cell international 13, 89–89, https://doi.org/10.1186/1475-2867-13-89 (2013).
Ramirez, C. P. & Fiedler, D. Investigating the role of inorganic phosphate in tumor metabolism and metastasis. Cancer & Metabolism 2, P55–P55, https://doi.org/10.1186/2049-3002-2-S1-P55 (2014).
Bobko, A. A. et al. Interstitial Inorganic Phosphate as a Tumor Microenvironment Marker for Tumor Progression. Sci Rep-Uk 7, 41233, https://doi.org/10.1038/srep41233 (2017).
Brown, R. B. & Razzaque, M. S. Phosphate toxicity and tumorigenesis. Biochim Biophys Acta Rev Cancer 1869, 303–309, https://doi.org/10.1016/j.bbcan.2018.04.007 (2018).
Zhang, Z., Hallac, R. R., Peschke, P. & Mason, R. P. A noninvasive tumor oxygenation imaging strategy using magnetic resonance imaging of endogenous blood and tissue water. Magnetic resonance in medicine 71, 561–569, https://doi.org/10.1002/mrm.24691 (2014).
Padhani, A. R., Krohn, K. A., Lewis, J. S. & Alber, M. Imaging oxygenation of human tumours. European radiology 17, 861–872, https://doi.org/10.1007/s00330-006-0431-y (2007).
O’Connor, J. P. B. et al. Oxygen-Enhanced MRI Accurately Identifies, Quantifies, and Maps Tumor Hypoxia in Preclinical Cancer Models. Cancer research 76, 787–795, https://doi.org/10.1158/0008-5472.CAN-15-2062 (2016).
Shi, Y. et al. Mapping in vivo tumor oxygenation within viable tumor by 19F-MRI and multispectral analysis. Neoplasia (New York, N.Y.) 15, 1241–1250 (2013).
Chen, L. Q. & Pagel, M. D. Evaluating pH in the Extracellular Tumor Microenvironment Using CEST MRI and Other Imaging Methods. Advances in radiology 2015, 206405, https://doi.org/10.1155/2015/206405 (2015).
Martinez, G. V. et al. Imaging the extracellular pH of tumors by MRI after injection of a single cocktail of T1 and T2 contrast agents. NMR in biomedicine 24, 1380–1391, https://doi.org/10.1002/nbm.1701 (2011).
Gillies, R. J., Raghunand, N., Karczmar, G. S. & Bhujwalla, Z. M. MRI of the tumor microenvironment. Journal of Magnetic Resonance Imaging 16, 430–450, https://doi.org/10.1002/jmri.10181 (2002).
Shinkwin, M. A. et al. Integrated magnetic resonance imaging and phosphorus spectroscopy of soft tissue tumors. Cancer 67, 1849–1858 (1991).
Beauregard, D. A. et al. Magnetic resonance imaging and spectroscopy of combretastatin A4 prodrug-induced disruption of tumour perfusion and energetic status. British journal of cancer 77, 1761–1767 (1998).
Epel, B., Redler, G. & Halpern, H. J. How in vivo EPR measures and images oxygen. Advances in experimental medicine and biology 812, 113–119, https://doi.org/10.1007/978-1-4939-0620-8_15 (2014).
Bratasz, A. et al. In vivo imaging of changes in tumor oxygenation during growth and after treatment. Magnetic resonance in medicine 57, 950–959, https://doi.org/10.1002/mrm.21212 (2007).
Swartz, H. M. et al. Clinical EPR: unique opportunities and some challenges. Academic radiology 21, 197–206, https://doi.org/10.1016/j.acra.2013.10.011 (2014).
Gorodetsky, A. A., Kirilyuk, I. A., Khramtsov, V. V. & Komarov, D. A. Functional electron paramagnetic resonance imaging of ischemic rat heart: Monitoring of tissue oxygenation and pH. Magn Reson Med 76, 350–358, https://doi.org/10.1002/mrm.25867 (2016).
Marchand, V., Levêque, P., Driesschaert, B., Marchand-Brynaert, J. & Gallez, B. In vivo EPR extracellular pH-metry in tumors using a triphosphonated trityl radical. Magnetic Resonance in Medicine 77, 2438–2443, https://doi.org/10.1002/mrm.26316 (2016).
Bobko, A. A. et al. In vivo monitoring of pH, redox status, and glutathione using L-band EPR for assessment of therapeutic effectiveness in solid tumors. Magn Reson Med 67, 1827–1836, https://doi.org/10.1002/mrm.23196 (2012).
Dhimitruka, I., Bobko, A. A., Eubank, T. D., Komarov, D. A. & Khramtsov, V. V. Phosphonated trityl probes for concurrent in vivo tissue oxygen and pH monitoring using electron paramagnetic resonance-based techniques. J Am Chem Soc 135, 5904–5910, https://doi.org/10.1021/ja401572r (2013).
Swartz, H. M. et al. Advances in probes and methods for clinical EPR oximetry. Advances in experimental medicine and biology 812, 73–79, https://doi.org/10.1007/978-1-4939-0620-8_10 (2014).
Pandian, R. P. et al. A New Tetragonal Crystalline Polymorph of Lithium Octa-n-Butoxy-Naphthalocyanine (LiNc-BuO) Radical: Structural, Magnetic and Oxygen-Sensing Properties. Chemistry of Materials 22, 6254–6262, https://doi.org/10.1021/cm101733h (2010).
Gorodetskii, A. A. et al. Oxygen-induced leakage of spin polarization in Overhauser-enhanced magnetic resonance imaging: Application for oximetry in tumors. J Magn Reson 297, 42–50, https://doi.org/10.1016/j.jmr.2018.10.005 (2018).
Kishimoto, S., Krishna, M. C., Khramtsov, V. V., Utsumi, H. & Lurie, D. J. In Vivo Application of Proton-Electron Double-Resonance Imaging. Antioxid Redox Signal 28, 1345–1364, https://doi.org/10.1089/ars.2017.7341 (2018).
Krishna, M. C. et al. Overhauser enhanced magnetic resonance imaging for tumor oximetry: coregistration of tumor anatomy and tissue oxygen concentration. Proc Natl Acad Sci USA 99, 2216–2221, https://doi.org/10.1073/pnas.042671399 (2002).
Mellet, P. et al. New Concepts in Molecular Imaging: Non-Invasive MRI Spotting of Proteolysis Using an Overhauser Effect Switch. Plos One 4, e5244, https://doi.org/10.1371/journal.pone.0005244 (2009).
Waddington, D. E. J. et al. An Overhauser-enhanced-MRI platform for dynamic free radical imaging in vivo. NMR in Biomedicine 31, e3896, https://doi.org/10.1002/nbm.3896 (2018).
Efimova, O. V. et al. Standard-based method for proton-electron double resonance imaging of oxygen. J Magn Reson 212, 197–203, https://doi.org/10.1016/j.jmr.2011.06.030 (2011).
Yamato, M. et al. Overhauser-enhanced magnetic resonance imaging characterization of mitochondria functional changes in the 6-hydroxydopamine rat model. Neurochem Int 59, 804–811, https://doi.org/10.1016/j.neuint.2011.08.010 (2011).
Nakata, R. et al. In vivo redox metabolic imaging of mitochondria assesses disease progression in non-alcoholic steatohepatitis. Sci Rep 7, 17170, https://doi.org/10.1038/s41598-017-17447-2 (2017).
Eto, H. et al. Redox imaging of skeletal muscle using in vivo DNP-MRI and its application to an animal model of local inflammation. Free Radical Bio Med 89, 1097–1104, https://doi.org/10.1016/j.freeradbiomed.2015.10.418 (2015).
Kawano, T. et al. Noninvasive mapping of the redox status of dimethylnitrosamine-induced hepatic fibrosis using in vivo dynamic nuclear polarization-magnetic resonance imaging. Sci Rep-Uk 6, 32604, https://doi.org/10.1038/srep32604 (2016).
Ahn, K. H., Scott, G., Stang, P., Conolly, S. & Hristov, D. Multiparametric imaging of tumor oxygenation, redox status, and anatomical structure using overhauser‐enhanced MRI–prepolarized MRI system. Magnetic resonance in medicine 65, 1416–1422 (2011).
Golman, K. et al. Dynamic in vivo oxymetry using overhauser enhanced MR imaging. J Magn Reson Imaging 12, 929–938 (2000).
Matsumoto, S. et al. Influence of proton T1 on oxymetry using Overhauser enhanced magnetic resonance imaging. Magn Reson Med 54, 213–217, https://doi.org/10.1002/mrm.20564 (2005).
Matsumoto, S. et al. Simultaneous imaging of tumor oxygenation and microvascular permeability using Overhauser enhanced MRI. Proc Natl Acad Sci USA 106, 17898–17903, https://doi.org/10.1073/pnas.0908447106 (2009).
Samouilov, A. et al. In vivo proton-electron double-resonance imaging of extracellular tumor pH using an advanced nitroxide probe. Anal Chem 86, 1045–1052, https://doi.org/10.1021/ac402230h (2014).
Takahashi, W. et al. Proton-Electron Double-Resonance Imaging of pH using phosphonated trityl probe. Appl Magn Reson 45, 817–826, https://doi.org/10.1007/s00723-014-0570-2 (2014).
Armstrong, B. D. & Han, S. A new model for Overhauser enhanced nuclear magnetic resonance using nitroxide radicals. J Chem Phys 127, 104508, https://doi.org/10.1063/1.2770465 (2007).
Song, Y., Liu, Y., Liu, W., Villamena, F. A. & Zweier, J. L. Characterization of the binding of the Finland trityl radical with bovine serum albumin. RSC Advances 4, 47649–47656, https://doi.org/10.1039/C4RA04616A (2014).
Poncelet, M. et al. Dextran-conjugated tetrathiatriarylmethyl radicals as biocompatible spin probes for EPR spectroscopy and imaging. Bioorganic & Medicinal Chemistry Letters 29, 1756–1760, https://doi.org/10.1016/j.bmcl.2019.05.017 (2019).
Lurie, D. J., Li, H., Petryakov, S. & Zweier, J. L. Development of a PEDRI free-radical imager using a 0.38 T clinical MRI system. Magn Reson Med 47, 181–186 (2002).
Ryzhov, S. et al. Host A(2B) adenosine receptors promote carcinoma growth. Neoplasia 10, 987–995 (2008).
Acknowledgements
This work was partially supported by NIH grants CA194013, CA192064, U54GM104942, EB023990, and P20GM121322. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH. The WVCTSI is acknowledged for a start-up to V.V.K., A.A.B., and T.D.E. The authors thank Prof. E. G. Bagryanskaya for the useful discussion. The Ministry of Education and Science of the Russian Federation is acknowledged for financial support to A.A.G. (grant 14.W03.31.0034)
Author information
Authors and Affiliations
Contributions
A.A.G., V.V.K. and A.A.B. were responsible for study design. A.A.G. performed all the OMRI measurements, developed the theoretical basis for data analysis, and performed raw data analysis and processing. T.D.E., E.E., and A.A.B. provided animal care and assisted in in vivo OMRI measurements, B.D. and M.P. synthesized dpTAM probe, T.D.E. and V.V.K. edited the manuscript, and A.A.G. and A.A.B. wrote the manuscript.
Corresponding authors
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Gorodetskii, A.A., Eubank, T.D., Driesschaert, B. et al. Development of multifunctional Overhauser-enhanced magnetic resonance imaging for concurrent in vivo mapping of tumor interstitial oxygenation, acidosis and inorganic phosphate concentration. Sci Rep 9, 12093 (2019). https://doi.org/10.1038/s41598-019-48524-3
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-019-48524-3
- Springer Nature Limited
This article is cited by
-
In Vivo Electron Paramagnetic Resonance Molecular Profiling of Tumor Microenvironment upon Tumor Progression to Malignancy in an Animal Model of Breast Cancer
Molecular Imaging and Biology (2024)
-
Trityl radicals: synthesis, properties, and applications
Russian Chemical Bulletin (2021)