Abstract
Neutron Tomography (NT) is a non-destructive technique to investigate the inner structure of a wide range of objects and, in some cases, provides valuable results in comparison to the more common X-ray imaging techniques. However, NT is time consuming and scanning a set of similar objects during a beamtime leads to data redundancy and long acquisition times. Nowadays NT is unfeasible for quality checking study of large quantities of similar objects. One way to decrease the total scan time is to reduce the number of projections. Analytical reconstruction methods are very fast but under this condition generate streaking artifacts in the reconstructed images. Iterative algorithms generally provide better reconstruction for limited data problems, but at the expense of longer reconstruction time. In this study, we propose the recently introduced Neural Network Filtered Back-Projection (NN-FBP) method to optimize the time usage in NT experiments. Simulated and real neutron data were used to assess the performance of the NN-FBP method as a function of the number of projections. For the first time a machine learning based algorithm is applied and tested for NT image reconstruction problem. We demonstrate that the NN-FBP method can reliably reduce acquisition and reconstruction times and it outperforms conventional reconstruction methods used in NT, providing high image quality for limited datasets.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Introduction
Neutron Tomography (NT) is a well established technique that provides the map of the neutron attenuation coefficients within an object1,2. Neutron Imaging (NI) is especially well suited to study for example thick metals, hydrogenous materials and porous media3, hence found applications in biology4,5,6, agriculture7,8, archaeology9,10, material science and engineering11. In some cases NI offers incomparable results with respect to X-ray imaging. Computed Tomography (CT) consists in acquiring many transmission images of the sample at different angle views. Subsequently, the three-dimensional map of the attenuation coefficients is computed starting from the projection data by means of a mathematical reconstruction algorithm. Long scan times - generally several hours, depending on the sample and the desired spatial resolution - are required to perform neutron measurements, since the flux of the existing neutron sources is several order of magnitude lower than the X-ray sources. NT is a useful tool for evaluating the structural integrity of objects but it is time-consuming and therefore not feasible to scan large quantities of similar samples, such as in quality check systems. Hence, in the NT field there is great interest in the reduction of scan time, motivated also by the high neutrons production cost.
One way to reduce the CT scan time is to limit the number of projections. Analytical reconstruction algorithms, e. g. the widely used Filtered Back-Projection (FBP) algorithm, generate streaking artifacts in the reconstructed images when the number of projections does not satisfy the Nyquist-Shannon condition12,13. Conversely, iterative algorithms better handle limited and noisy datasets, providing higher reconstruction quality than analytical algorithms14. In fact, they rely on a discrete representation of the image formation process, described by a linear system of equations solvable through an iterative optimization method. A wide variety of regularized iterative methods have been proposed in literature15,16,17,18,19. This class of reconstruction algorithms involve additional regularizing terms in the objective function. The prior knowledge about the scanned sample is embedded in the regularizing term, providing accurate reconstruction from high under-sampled datasets. Recently, the performances of the FBP algorithm and different iterative reconstruction methods were tested with neutron data and discussed20. Although iterative methods generally outperform analytical ones to handle limited-data problems, they present two major drawbacks. The first is the high computational cost, several order of magnitude greater than analytical methods. The latter is the limited variety of samples that can be reconstructed, due the constrain imposed by the specific prior knowledge. For example, Total Variation minimization based methods can be used only to accurately reconstruct objects with sparse gradient. Hence, the application to large-scale tomographic data is still limited.
Nowadays, Deep Learning21 (DL) has reached state-of-the-art performance for image classification22,23,24, segmentation25,26,27, image denoising28,29,30, deconvolution31 and artifact reduction32,33. Recently, new Machine Learning (ML) based methods were introduced to improve low-dose and Sparse-View X-ray tomography34,35,36,37,38,39,40,41. These methods are data-driven, i.e. they learn the image features from training data providing more accurate reconstructions than analytical methods.
In this work we propose the recently introduced Neural Network Filtered Back-Projection (NN-FBP) method42 to reduce the acquisition time in NT experiments. At the best of our knowledge, this is the first study which proposes and tests a ML based reconstruction method for NT. The NN-FBP method avoids to a degree the aforementioned problems of analytical and iterative reconstruction algorithms. In fact, NN-FBP is faster than iterative methods, since it has similar computation complexity to FBP, and learns how to use problem specific knowledge, providing high image quality even for limited datasets. We demonstrate that this method is suitable for neutron data and outperforms conventional reconstruction methods used in NT. Furthermore, the NN-FBP method can reliably reduce the scan time, reconstruction time and the amount of data storage. As case study, we chose to inspect part of a monoblock (Fig. 1) from the divertor region of a fusion energy device by means of Sparse-View NT and the NN-FBP reconstruction algorithm. The main motivation of employing the fusion divertor monoblock as a specimen is because of the large number of armor that will be required for the divertor assembly within the ITER project43 and consequently matches the need of a quality check technique. The structural integrity of these samples subjected to high thermal loads is fundamental within a tokamak fusion energy device. A comparative study between X-ray CT and NT has been recently carried out44 to inspect the quality of manufactured monoblocks.
In our work, simulated and real neutron data were used to assess the performances of the NN-FBP, FBP and Simultaneous Iterative Reconstruction Technique (SIRT)45 methods as a function of the number of projections. The reconstructed images were quantitatively compared in terms of several image quality indexes.
Results
The NN-FBP method combines different FBP reconstructions, each with a custom filter, to produce a single image. The filters are determined by training an Artificial Neural Network (ANN). A brief description of the algorithm and of the ANN architecture is reported in the Methods section. The network input is a vector that contains the projection data and the network output is a single reconstructed pixel. The intermediate hidden layer of the network consists of Nh hidden nodes. This parameter can be chosen freely and, in the NN-FBP implementation, represents the number of different FBP reconstructions to compute and combine in a single image. We used simulated data to find the optimal value of Nh which ensures the best balance between reconstructed image quality and reconstruction time. We underline that the network must be re-trained to change the number of hidden nodes.
Afterwards, we quantitatively compared the NN-FBP, FBP and SIRT methods as a function of the number of projections using both simulated and real data. The evaluation of the image quality was carried out by computing the Normalized Root Mean Square Error (NRMSE), the Structural Similarity Index (SSIM)46, the Feature Similarity Index (FSIM)47 and the Gradient Magnitude Similarity Deviation (GMSD)48. The NRMSE is a measure of the reconstruction error and it is defined as:
where Irec and Igt are vectors containing pixel values of the reconstructed and ground truth image, respectively, \(||\cdot {||}_{2}\) is the Euclidean norm. In our analysis, the NRMSE was computed both on the sample (NRMSE sample) and on a ring-shaped region of interest (NRMSE ring) shown in Fig. 2 in order to evaluate the reconstruction accuracy of a particular thin feature of the specimen. The sample mask was computed using the Otsu’s thresholding method49. The SSIM index quantifies the structural similarity between two images by comparing the luminance, the contrast and the structure. The SSIM value ranges from −1 to 1, a higher value indicates superior image quality. The FSIM is an image quality index that better reflects the perception of the human visual system evaluating salient low-level image features. In fact, FSIM index exploits the phase congruency and the image gradient magnitude, which are complementary features in characterizing the image quality. The FSIM value ranges from 0 to 1, a higher value indicates superior image quality. The GMSD index measures the variation in the similarity of gradient maps between two images. We used this metric to assess the quality of the edges. GMSD values lie between 0 and 1, a value closer to 0 indicates better similarity in the gradient maps.
Simulation study
A numerical phantom, which mimics the Cu-CuCrZr pipe (Fig. 1), was generated to find optimal parameters for the reconstruction and to test the NN-FBP method. A slice of the numerical phantom is shown in Fig. 2. Simulated projections were obtained by computing the Radon Transform of the phantom image, assuming a parallel beam geometry. First, we reconstruct images from an over-sampled dataset of 1335 projections using the SIRT method with 400 iterations. The over-sampled dataset contains twice the number of projections required by the Nyquist-Shannon condition. In fact, the sampling theorem is exactly satisfied for 668 projections (the widest horizontal dimension of the sample is ~430 pixels long). We then train the ANN to mimic the reconstructed images obtained from the oversampled dataset, using a subset of the available projections. The network was trained on 105 pixels/slice from 10 training images and 105 pixels/slice from 10 validation images. The image quality indexes were evaluated on 30 reconstructed images of a numerical phantom that differs from spatial orientation from the one used for training. We used the original phantom images as ground truth image.
Firstly, we evaluated the quality of the NN-FBP reconstruction for different number of hidden nodes (Nh). Figure 3 shows the NRMSE computed over the whole image and the reconstruction time as a function of the number of projections (Nproj). Each line represents reconstructions with 1, 2, 4 and 8 hidden nodes. It is clear that in general higher reconstructed image quality is achieved by increasing the number of hidden nodes, but at the expense of a longer reconstruction time. Hence, we chose to use 4 hidden nodes in both simulated and experimental study, since it ensures a good balance between image quality and short reconstruction time (less than 300 ms for under-sampled datasets).
Afterwards, we compared the reconstruction quality of the NN-FBP with respect to the quality of conventional algorithms SIRT and FBP, in terms of the aforementioned image quality indexes. In our analysis, all FBP reconstructions were performed with the Ram-Lak filter. Figure 4 shows the NRMSE sample (top-left), the NRMSE ring (top-right), the SSIM (bottom-left) and the FSIM (bottom-right) evaluated from FBP, SIRT and NN-FBP reconstructions of simulated data as a function of the number of projections. It is clear that NN-FBP method outperforms significantly the FBP and SIRT. In fact, the indexes related to NN-FBP reconstructions indicate better image quality than conventional algorithms for all number of projections considered. The FSIM turns out to be the most significant image quality index. It is evident from the FSIM plot in Fig. 4 that the number of projections can be reduced using the NN-FBP method to 134, i.e. 1/8 of the over-sampled dataset and 1/4 of the projections required by the sampling theorem, ensuring image quality comparable to FBP reconstruction for Nproj = 668.
Experimental study
Neutron images of the sample were acquired at the IMAT beamline50,51,52, ISIS neutron spallation source, Rutherford Appleton Laboratory, U.K. We performed tomographic scans of two similar samples by collecting an over-sampled dataset of 1335 projections in the angular range [0°, 360°) with 30 s exposure time per projection, which is the maximum exposure time per projection allowed by the used camera. A complete CT scan takes approximately 11 hours. Our setup, described in detail in the section Methods, provides a number of neutrons per pixel equals to 1.5 ⋅ 103.
Also in this case, the oversampled datasets contains twice the number of projections required by the sampling theorem. The first sample was used to train the ANNs, the latter to evaluate the image quality of the NN-FBP reconstructions. The network was trained to mimic images obtained from 1335 projections using the SIRT method with 400 iteration. In particular, 105 pixels/slice from 10 training images and 105 pixels/slice from 10 validation images of the first sample were used to train the ANNs. We evaluated the image quality indexes on 30 reconstructed images of the second sample for each reconstruction method. At this stage, we regard as ground truth images the SIRT reconstruction of the oversampled dataset (Nproj = 1335) with 400 iterations.
Figure 5 shows the NRMSE sample (top-left), the NRMSE ring (top-right), the SSIM (bottom-left) and the FSIM (bottom-right) evaluated from FBP, SIRT and NN-FBP reconstructions of experimental data as a function of the number of projections. In general, the trend of each index obtained in the experimental study is quite similar to the results of the simulation study. In fact, the NN-FBP shows higher image quality than FBP and SIRT in terms of the NRMSE sample, SSIM and FSIM for all numbers of projections. From the NRMSE ring plot, we deduce that NN-FBP method provides at worst reconstruction comparable for accuracy to the SIRT. From the FSIM plot in Fig. 5 we conclude that the number of projections can be reduced using the NN-FBP method to 223, i.e. 1/6 of the over-sampled dataset and 1/3 of the projections required by the sampling theorem, ensuring image quality comparable to the standard FBP reconstruction for Nproj = 668.
In Fig. 6 we show a comparison of different reconstructed slices: the ground truth image, the FBP and SIRT reconstructions of 668 projections, matching exactly the Nyquist condition, and the FBP, SIRT and NN-FBP reconstructions for 223 and 67 projections. Below each image is shown the intensity profile along a line segment marked in each CT slice with a red dashed line. Furthermore the histogram of attenuation coefficients within the sample mask is represented below each intensity profile plot. We note from a visual inspection that for 223 projections the FBP reconstruction is affected by high noise dose which makes the segmentation not feasible. On the other hand, the NN-FBP method with 223 projections provides high contrast images and less noise than conventional algorithms. Furthermore, we note that the NN-FBP for Nproj = 223 is the only one method able to reconstruct images with a multimodal distribution of the pixel values. The edges and the sample features are accurately reconstructed. This result indicates that segmentation and analysis can be actually performed on a NN-FBP reconstruction of a limited dataset with 223 projections. When the number of projection is reduced to 67 (1/10 of the required one by the sampling theorem) the NN-FBP reconstructs well the strong edges but with an over-smoothing which suppresses low contrast structure. Hence the severe under-sampling in NN-FBP method leads to low-noise images but with a loose of image features.
To assess the local structural similarity of the reconstructed images with respect to the ground truth image we computed the local SSIM map. In Fig. 7 we show the SSIM maps related to the FBP and SIRT reconstructions of 668 projections, the FBP, SIRT and NN-FBP reconstructions of 223 projections. The histogram of local SSIM values is represented below each image and the global SSIM is also reported. We observe that in the case of the NN-FBP method with 223 projections the majority of local SSIM values range from 0.7 to 1 and globally around 0.67. This result is significantly better than the results obtained from FBP and SIRT for the same number of projections (i.e. global SSIM 0.30 and 0.47 for FBP and SIRT and majority of local SSIM values <0.7). Furthermore, the NN-FBP reconstruction of 223 projections outperforms the standard FBP reconstruction of 668 projections in terms of local and global SSIM values. However, the SIRT reconstruction of 668 projections shows slightly better structural similarity respect the ground image than the NN-FBP reconstruction for 223 projections. In fact, the global SSIM for the SIRT image is 0.72 while for NN-FBP image is 0.67.
In Fig. 8 we show a comparison of the GMSD values computed with respect to the ground truth image for each reconstruction algorithm as a function of the number of projections. We observe that for each reconstruction method the edge quality decreases when the number of projections is reduced. However, the NN-FBP outperforms SIRT and FBP in terms of the GMSD values for each number of projections considered. Furthermore, the edge quality of the NN-FBP reconstruction of 223 projections is comparable to the standard FBP reconstruction of 668 projections.
Finally, we evaluated the average reconstruction time per slice of the FBP, SIRT and NN-FBP methods as a function of the number of projections. The results are shown in Fig. 9. The FBP method is the fastest reconstruction algorithm. However, NN-FBP is in general one order of magnitude faster than SIRT and one order of magnitude slower than FBP, ensuring reconstruction time per slice of the order of tenths of a second. In Table 1 we report the training time of the NN-FBP method as a function of the number of projections and for different number of hidden nodes. Obviously the training time increases with the amount of training and validation data and in our analysis we fixed them. For each training stage we used 105 pixels/slice from 10 training images and 105 pixels/slice from 10 validation images. We observe from Table 1 that the training time increases with the Nh value but does not strictly depend on the number of projections. In general, the training task requires tens of minutes which is a reasonable time with respect to the acquisition time of a NT scan.
Discussion and Conclusions
We have studied for the first time the performance of the NN-FBP method with neutron data and compared to conventional reconstruction algorithms used in NT in terms of different image quality metrics. We demonstrate that NN-FBP method outperforms the FBP and SIRT ones with respect to image quality. Furthermore, the computation complexity of NN-FBP method is lower than SIRT. Hence, NN-FBP method provides reconstructions in shorter times with respect to iterative methods. We conclude that the NN-FBP can reliably reduce scan time, reconstruction time and data storage providing high image quality for sparse-view NT. Specific prior knowledge is not explicitly moulded in the NN-FBP method, as opposed to advanced iterative reconstruction algorithms. In fact the method learns the features of the training images by tuning the neural network’s weights appropriately. Hence the NN-FBP method can be implemented with high computational efficiency at neutron imaging facilities for the broader applicability than regularized iterative reconstruction algorithms.
The main requirement of the NN-FBP method is that the scanned objects should consist only of the same materials present in the training samples. When this prerequisite is satisfied the NN-FBP method is able to reconstruct accurately objects with different shape and size of the training samples53.
Our experimental study demonstrates that using the NN-FBP method, the number of projections can be reduced to 1/3 of the projections required by the sampling theorem, ensuring image quality comparable to standard FBP reconstruction. Hence, the acquisition time can be reduced to 1/3 of the time requested by a standard CT scan. However, the reconstruction quality of the NN-FBP is highly dependent on the quality of the projections and reconstructed images used in the training stage. In principle, better results can be obtained by optimizing the imaging setup to increase the signal-to-noise ratio of neutron projections.
In this study, we focused on the application of the NN-FBP method to sparse-view CT reconstruction of objects similar to a training sample, which was scanned over a large number of view angles. The NN-FBP was trained using the SIRT reconstruction of the over-sampled training dataset. However, several experimental situations limit the angles for which projection data can be acquired. The NN-FBP method can be used in these cases to emulate an advanced but slow regularized iterative method to produce reconstructions from limited projection data. In particular, this can be of great interest for spatio-temporal reconstruction of dynamic systems. For example, the NN-FBP method could be used to study the dynamics of slow periodic phenomena in a stroboscopic mode by acquiring projections according to a Golden ratio based sequence54. The training should be performed on high-quality reconstruction of the system at particular time instant. The temporal evolution can be reconstructed with NN-FBP if the aforementioned prerequisite is satisfied during the experiment. However the feasibility of these applications in NT remains subject of further research.
The NN-FBP can be used to reconstruct also truncated data, occurring when the scanned object is larger than the field-of-view (FOV) of the imaging system. Truncated sinograms can lead to strong artifacts in the reconstructed images. When using the FBP method with truncated data, the artifacts can be reduced by replicating the projection boundary values to form a larger virtual detector55. This method cannot be applied to iterative algorithms, which require projections of the entire sample. Conversely, the padding approach can be used with the NN-FBP method since it is based on FBP reconstructions with custom filters.
We think that the NN-FBP could be improved by using deeper networks with the aim of learning more features of the sample. Deep learning and machine learning in general are promising and innovative approaches for image reconstruction. This field of research nowadays is of interest in medical and X-ray imaging56, but we think that also the NI community should take into account new ML based reconstruction theories and techniques.
Methods
Sample
Fabrication of the Cu-CuCrZr pipe, shown in Fig. 1, was carried out in the following way. Firstly, the inner CuCrZr pipe with a thickness of 1 mm was wrapped in three turns of a 25 μm thick braze foil to a total thickness of 75 μm. The braze foil is a 50:50 copper-gold mix known commercially as OrobrazeTM. Next, two half copper pipe ‘sleeves’ were placed around the inner pipe. The sleeves were held in place by tying them with a molybdenum wire in several locations along the length of the pipe. This assembly was heated in a vacuum furnace to perform the brazing cycle and join the inner and outer pipes. Finally, the molybdenum wire was removed, and 1 mm wide grooves were machined along the length of the copper pipe; one groove along one side and seven equidistant grooves on the opposing side. For the purpose of this investigation, a length of 20 mm pipe was cut from a longer part.
Overview of the approach
The NN-FBP method is based on a nonlinear weighted sum of different FBP reconstructions, each of these with a specific filter. A neural network model is exploited to train these custom filters. The type of network used for the NN-FBP is the multilayer perceptron57. This network has three layers: the input layer, the hidden layer and the output layer, each of them composed of n, Nh and m nodes, respectively. In a multilayer perceptron, each input node is connected to all hidden nodes with a weight wij, and each hidden node to all output nodes with a weight qij. Hence, the connections between the input layer and the hidden layer is described by the n × Nh matrix W, containing the wij weights. The m × Nh matrix Q containing the weights qij represents the connections between the hidden nodes and the output nodes. Scalar values are subtracted from the output of each hidden and output node. Moreover, a logistic function σ is applied as activation function to the output of each hidden and output node, making the neural network a nonlinear model. The number of hidden nodes Nh is a free parameter, to be determined for each specific problem. The output vector O of a multilayer perceptron, with Nh number of hidden nodes, for the input vector z can be expressed as:
where wi and qi are single columns of the matrices W and Q respectively, while bi and b0 are the bias weights. According to supervised learning approach, an unknown function can be approximated by an ANN if the output values fi are known for a particular set of T input vectors zi. Hence, the network weights are found in a training task that consists in minimize the cost function:
In the case of the NN-FBP, the input vector has the same size of the detector array, composed of Nd elements each with coordinate τd. The input vector components can be expressed as follows:
while output layer is composed of a single node and described by the formula:
The output of the neural network can be viewed as weighted sum of Nh FBP reconstructions with custom filters and specific biases. Hence, the computational complexity of the NN-FBP method depends on the number of hidden nodes Nh, but is comparable to the FBP method.
Tomographic acquisition at the IMAT beamline
The data acquisition was carried out at the IMAT beamline, ISIS neutron spallation source, Rutherford Appleton Laboratory, U.K. The sample was placed on the rotating platform at the distance L = 10 m from the beam aperture and at the distance d = 25 mm from the scintillator screen. The diameter of the beam aperture was D = 40 mm, resulting in a L/D ratio of 250. The neutron flux for this setup is 5.9 ⋅ 106 n/cm2/s51. The imaging system consisted of a CMOS camera with 2048 × 2048 pixels coupled with optical lenses and a scintillator 6LiF/ZnS with thickness of 50 μm. The FOV was set to 59.5 × 59.5 mm2 and the resulting pixel size was 29 μm. Each tomographic scan was performed by collecting a set of 1335 radiographs in the angular range [0°, 360°), with an exposure time of 30 s for each projection and an overall scan time of approximately 11 hours. Open beam and dark field images were taken as well in order to perform the data normalization.
Data processing and reconstruction
The acquired raw projections were normalized respect to the dark images, flat field images and to the neutron dose. Afterwards, the normalized projections were pre-processed by removing dead-pixels and gamma-spots, while ring artifacts were suppressed by means of a filter based on combined wavelet and Fourier analysis58.
In the simulation experiment, we generated images of 3480 × 3480 pixels representing a slice of the sample (Fig. 2). We evaluated equispaced projections in the angular range [0°, 360°) for a detector with 3480 pixels. We assumed a parallel beam geometry which is a fair approximation for neutron beams characterized by an L/D ratio of 250. Afterwards, we rebinned the projected data to 870 pixels and we added Poisson noise assuming 5000 counts as background intensity. The reconstruction was done on a 870 × 870 pixels grid.
Pre-processing, reconstruction and analysis of simulated and real data were performed using a Python code developed ad hoc. For the CT reconstruction task we exploit the ASTRA toolbox59,60. All reconstructions and simulations were performed on a Linux workstation equipped with an Intel Core i7-6700HQ CPU @ 3.40 GHz CPU, 64 GB of system RAM and a NVIDIA GTX TITAN X GPU.
Data Availability
The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
References
Schillinger, B., Lehmann, E. & Vontobel, P. 3D neutron computed tomography: requirements and applications. Physica B: Condensed Matter 276–278, 59–62, https://doi.org/10.1016/S0921-4526(99)01254-5 (2000).
Vontobel, P., Lehmann, E. H., Hassanein, R. & Frei, G. Neutron tomography: Method and applications. Physica B: Condensed Matter 385–386, 475–480, https://doi.org/10.1016/j.physb.2006.05.252 (2006).
Kaestner, A. P. et al. Recent developments in neutron imaging with applications for porous media research. Solid Earth 7, 1281–1292, https://doi.org/10.5194/se-7-1281-2016 (2016).
Micieli, D. et al. Characterizing pearls structures using X-ray phase-contrast and neutron imaging: a pilot study. Scientific Reports, https://doi.org/10.1038/s41598-018-30545-z (2018).
Tsuchiya, Y. et al. Imaging of Rabbit VX-2 Hepatic Cancer by Cold and Thermal Neutron Radiography. Japanese Journal of Applied Physics 42, 7151 (2003).
Moghaddam, K. K., Taheri, T. & Ayubian, M. Bone structure investigation using X-ray and neutron radiography techniques. Applied Radiation and Isotopes 66, 39–43, https://doi.org/10.1016/j.apradiso.2007.07.011 (2008).
Warren, J. M. et al. Neutron imaging reveals internal plant water dynamics. Plant and Soil 366, 683–693, https://doi.org/10.1007/s11104-012-1579-7 (2013).
Esser, H. G., Carminati, A., Vontobel, P., Lehmann, E. H. & Oswald, S. E. Neutron radiography and tomography of water distribution in the root zone. Journal of Plant Nutrition and Soil Science 173, 757–764, https://doi.org/10.1002/jpln.200900188 (2010).
Lehmann, E. H., Deschler-Erb, E. & Ford, A. Neutron tomography as a valuable tool for the non-destructive analysis of historical bronze sculptures. Archaeometry 52, 272–285, https://doi.org/10.1111/j.1475-4754.2009.00480.x. (2010).
Lehmann, E. H., Hartmann, S. & Speidel, M. O. Investigation of the content of ancient tibetan metallic buddha statues by means of neutron imaging methods. Archaeometry 52, 416–428, https://doi.org/10.1111/j.1475-4754.2009.00488.x. (2010).
Penumadu, D. Material science and engineering with neutron imaging. In Bilheux, H. Z., McGreevy, R. & Anderson, I. S. (eds) Neutron Imaging and Applications: A Reference for the Imaging Community, 209–227 (Springer US, Boston, MA, 2009).
Kak, A. C. & Slaney, M. Principles of computerized tomographic imaging (Society for Industrial and Applied Mathematics, 2001).
Buzug, T. M. Computed tomography: from photon statistics to modern Cone-Beam CT (Springer, Berlin, 2008).
Beister, M., Kolditz, D. & Kalender, W. A. Iterative reconstruction methods in X-ray CT. Physica Medica 28, 94–108, https://doi.org/10.1016/j.ejmp.2012.01.003 (2012).
Yu, W., Wang, C., Nie, X., Huang, M. & Wu, L. Image Reconstruction for Few-view Computed Tomography Based on l 0 Sparse Regularization. Procedia Computer Science 107, 808–813, https://doi.org/10.1016/j.procs.2017.03.178, Advances in Information and Communication Technology: Proceedings of 7th International Congress of Information and Communication Technology (ICICT2017) (2017).
Abir, M., Islam, F., Wachs, D. & Lee, H.-K. Sparse-view neutron CT reconstruction of irradiated fuel assembly using total variation minimization with Poisson statistics. Journal of Radioanalytical and Nuclear Chemistry 307, 1967–1979, https://doi.org/10.1007/s10967-015-4542-2 (2016).
Liu, Y., Ma, J., Fan, Y. & Liang, Z. Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction. Physics in Medicine & Biology 57, 7923 (2012).
Liu, Y. et al. Total Variation-Stokes Strategy for Sparse-View X-ray CT Image Reconstruction. IEEE Transactions on Medical Imaging 33, 749–763 (2014).
Han, X., Bian, J., Ritman, E. L., Sidky, E. Y. & Pan, X. Optimization-based reconstruction of sparse images from few-view projections. Physics in Medicine & Biology 57, 5245 (2012).
Micieli, D., Minniti, T., Formoso, V., Kockelmann, W. & Gorini, G. A comparative study of reconstruction methods applied to Neutron Tomography. Journal of Instrumentation 13, C06006 (2018).
Lecun, Y., Bengio, Y. & Hinton, G. Deep learning. Nature 521, 436–444, https://doi.org/10.1038/nature14539 (2015).
Krizhevsky, A., Sutskever, I. & Hinton, G. E. Imagenet classification with deep convolutional neural networks. In Pereira, F., Burges, C. J. C., Bottou, L. & Weinberger, K. Q. (eds) Advances in Neural Information Processing Systems 25, 1097–1105 (Curran Associates, Inc., 2012).
Szegedy, C. et al. Going deeper with convolutions. In 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), 1–9, https://doi.org/10.1109/CVPR.2015.7298594 (2015).
Russakovsky, O. et al. ImageNet Large Scale Visual Recognition Challenge. International Journal of Computer Vision (IJCV) 115, 211–252, https://doi.org/10.1007/s11263-015-0816-y (2015).
Guo, Y., Liu, Y., Georgiou, T. & Lew, M. S. A review of semantic segmentation using deep neural networks. International Journal of Multimedia Information Retrieval 7, 87–93, https://doi.org/10.1007/s13735-017-0141-z (2018).
Long, J., Shelhamer, E. & Darrell, T. Fully convolutional networks for semantic segmentation. In 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), 3431–3440, https://doi.org/10.1109/CVPR.2015.7298965 (2015).
Ronneberger, O., Fischer, P. & Brox, T. U-net: Convolutional networks for biomedical image segmentation. In Navab, N., Hornegger, J., Wells, W. M. & Frangi, A. F. (eds) Medical Image Computing and Computer-Assisted Intervention-MICCAI 2015, 234–241 (Springer International Publishing, Cham, 2015).
Koziarski, M. & Cyganek, B. Deep neural image denoising. In Chmielewski, L. J., Datta, A., Kozera, R. & Wojciechowski, K. (eds) Computer Vision and Graphics, 163–173 (Springer International Publishing, Cham, 2016).
Xie, J., Xu, L. & Chen, E. Image denoising and inpainting with deep neural networks. In Pereira, F., Burges, C. J. C., Bottou, L. & Weinberger, K. Q. (eds) Advances in Neural Information Processing Systems 25, 341–349 (Curran Associates, Inc., 2012).
Burger, H. C., Schuler, C. J. & Harmeling, S. Image denoising: Can plain neural networks compete with BM3D? In 2012 IEEE Conference on Computer Vision and Pattern Recognition, https://doi.org/10.1109/CVPR.2012.6247952, 2392–2399 (2012).
Xu, L., Ren, J. S., Liu, C. & Jia, J. Deep convolutional neural network for image deconvolution. In Ghahramani, Z., Welling, M., Cortes, C., Lawrence, N. D. &Weinberger, K. Q. (eds) Advances in Neural Information Processing Systems 27, 1790–1798 (Curran Associates, Inc., 2014).
Guo, J. & Chao, H. Building dual-domain representations for compression artifacts reduction. In Leibe, B., Matas, J., Sebe, N. & Welling, M. (eds) Computer Vision–ECCV 2016, 628–644 (Springer International Publishing, Cham, 2016).
Dong, C., Deng, Y., Change Loy, C. & Tang, X. Compression artifacts reduction by a deep convolutional network. In The IEEE International Conference on Computer Vision (ICCV) (2015).
Chen, H. et al. Low-dose ct via convolutional neural network. Biomed. Opt. Express 8, 679–694, https://doi.org/10.1364/BOE.8.000679 (2017).
Yang, X. et al. Low-dose x-ray tomography through a deep convolutional neural network. Scientific Reports 8, https://doi.org/10.1038/s41598-018-19426-7 (2018).
Sparse-view CT reconstruction with improved GoogLeNet, vol. 10578, https://doi.org/10.1117/12.2295345.
Gupta, H., Jin, K. H., Nguyen, H. Q., McCann, M. T. & Unser, M. CNN-Based Projected Gradient Descent for Consistent CT Image Reconstruction. IEEE Transactions on Medical Imaging 37, https://doi.org/10.1109/TMI.2018.2832656 (2018).
Jin, K. H., McCann, M. T., Froustey, E. & Unser, M. Deep Convolutional Neural Network for Inverse Problems in Imaging. IEEE Transactions on Image Processing 26, 4509–4522, https://doi.org/10.1109/TIP.2017.2713099 (2017).
Hammernik, K., Würfl, T., Pock, T. & Maier, A. A Deep Learning Architecture for Limited-Angle Computed Tomography Reconstruction. In Maier-Hein, K. H., geb. Fritzsche, Deserno, T. M., geb. Lehmann, Handels, H. & Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2017, 92–97 (Springer Berlin Heidelberg, Berlin, Heidelberg, 2017).
Würfl, T. et al. Deep Learning Computed Tomography: Learning Projection-Domain Weights From Image Domain in Limited Angle Problems. IEEE Transactions on Medical Imaging 37, 1454–1463 (2018).
Adler, J. & Öktem, O. Learned Primal-Dual Reconstruction. IEEE Transactions on Medical Imaging 37, 1322–1332 (2018).
Pelt, D. M. & Batenburg, K. J. Fast tomographic reconstruction from limited data using artificial neural networks. IEEE Transactions on Image Processing 22, 5238–5251, https://doi.org/10.1109/TIP.2013.2283142 (2013).
Motojima, O. The ITER project construction status. Nuclear Fusion 55, 104023, https://doi.org/10.1088/0029-5515/55/10/104023 (2015).
Evans, L. M. et al. Comparison of X-ray and neutron tomographic imaging to qualify manufacturing of a fusion divertor tungsten monoblock. Fusion Engineering and Design 134, 97–108, https://doi.org/10.1016/j.fusengdes.2018.06.017 (2018).
Gilbert, P. Iterative methods for the three-dimensional reconstruction of an object from projections. Journal of Theoretical Biology 36, 105–117, https://doi.org/10.1016/0022-5193(72)90180-4 (1972).
Wang, Z., Bovik, A. C., Sheikh, H. R. & Simoncelli, E. P. Image quality assessment: from error visibility to structural similarity. IEEE Transactions on Image Processing 13, 600–612, https://doi.org/10.1109/TIP.2003.819861 (2004).
Zhang, L., Zhang, L., Mou, X. & Zhang, D. FSIM: A Feature Similarity Index for Image Quality Assessment. IEEE Transactions on Image Processing 20, 2378–2386, https://doi.org/10.1109/TIP.2011.2109730 (2011).
Xue, W., Zhang, L., Mou, X. & Bovik, A. C. Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index. IEEE Transactions on Image Processing 23, 684–695, https://doi.org/10.1109/TIP.2013.2293423 (2014).
Otsu, N. A Threshold Selection Method from Gray-Level Histograms. IEEE Transactions on Systems, Man, and Cybernetics 9, 62–66, https://doi.org/10.1109/TSMC.1979.4310076 (1979).
Minniti, T. et al. Materials analysis opportunities on the new neutron imaging facility imatisis. Journal of Instrumentation 11, C03014, https://doi.org/10.1088/1748-0221/11/03/C03014 (2016).
Minniti, T., Watanabe, K., Burca, G., Pooley, D. E. & Kockelmann, W. Characterization of the new neutron imaging and materials science facility IMAT. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 888, 184–195, https://doi.org/10.1016/j.nima.2018.01.037 (2018).
Kockelmann, W. et al. Time-of-Flight Neutron Imaging on IMAT@ISIS: A New User Facility for Materials Science. Journal of Imaging 4, https://doi.org/10.3390/jimaging4030047 (2018).
Bladt, E., Pelt, D. M., Bals, S. & Batenburg, K. J. Electron tomography based on highly limited data using a neural network reconstruction technique. Ultramicroscopy 158, 81–88, https://doi.org/10.1016/j.ultramic.2015.07.001 (2015).
Kaestner, A. P., Trtik, P. & Munch, B. Spatiotemporal computed tomography of dynamic processes. Optical Engineering 50, 50-50-10, https://doi.org/10.1117/1.3660298 (2011).
Kyrieleis, A., Titarenko, V., Ibison, M., Connolley, T. & Withers, P. Region-of-interest tomography using filtered backprojection: assessing the practical limits. Journal of Microscopy 241, 69–82, https://doi.org/10.1111/j.1365-2818.2010.03408.x. (2010).
Wang, G. A perspective on deep imaging. IEEE Access 4, 8914–8924, https://doi.org/10.1109/ACCESS.2016.2624938 (2016).
Haykin, S. Neural Networks: A Comprehensive Foundation, 1st edn (Prentice Hall PTR, 1994).
Münch, B., Trtik, P., Marone, F. & Stampanoni, M. Stripe and ring artifact removal with combined wavelet-Fourier filtering. Optics Express 17, 8567, https://doi.org/10.1364/OE.17.008567 (2009).
van Aarle, W. et al. Fast and flexible X-ray tomography using the ASTRA toolbox. Opt. Express 24, 25129–25147, https://doi.org/10.1364/OE.24.025129 (2016).
Palenstijn, W., Batenburg, K. & Sijbers, J. Performance improvements for iterative electron tomography reconstruction using graphics processing units (GPUs). Journal of Structural Biology 176, 250–253, https://doi.org/10.1016/j.jsb.2011.07.017 (2011).
Author information
Authors and Affiliations
Contributions
D.M. and T.M. conceived the original idea. T.M and LL.M.E. performed the neutron measurements at the IMAT beamline. D.M. carried out the data analysis and developed the code. D.M. and T.M. discussed the experiment results. G.G. supervised the project. D.M. wrote the manuscript and all authors reviewed it.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Micieli, D., Minniti, T., Evans, L.M. et al. Accelerating Neutron Tomography experiments through Artificial Neural Network based reconstruction. Sci Rep 9, 2450 (2019). https://doi.org/10.1038/s41598-019-38903-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-019-38903-1
- Springer Nature Limited
This article is cited by
-
A novel panoptic segmentation model for lung tumor prediction using deep learning approaches
Soft Computing (2024)
-
A Review of Image-Based Simulation Applications in High-Value Manufacturing
Archives of Computational Methods in Engineering (2023)