Abstract
X-ray Fluorescence (XRF) microscopy is a growing approach for imaging the trace element concentration, distribution, and speciation in biological cells at the nanoscale. Moreover, three-dimensional nanotomography provides the added advantage of imaging subcellular structure and chemical identity in three dimensions without the need for staining or sectioning of cells. To date, technical challenges in X-ray optics, sample preparation, and detection sensitivity have limited the use of XRF nanotomography in this area. Here, XRF nanotomography was used to image the elemental distribution in individual E. coli bacterial cells using a sub-15 nm beam at the Hard X-ray Nanoprobe beamline (HXN, 3-ID) at NSLS-II. These measurements were simultaneously combined with ptychography to image structural components of the cells. The cells were embedded in small (3–20 µm) sodium chloride crystals, which provided a non-aqueous matrix to retain the three-dimensional structure of the E. coli while collecting data at room temperature. Results showed a generally uniform distribution of calcium in the cells, but an inhomogeneous zinc distribution, most notably with concentrated regions of zinc at the polar ends of the cells. This work demonstrates that simultaneous two-dimensional ptychography and XRF nanotomography can be performed with a sub-15 nm beam size on unfrozen biological cells to co-localize elemental distribution and nanostructure simultaneously.
Similar content being viewed by others
Introduction
Trace elements are essential for carrying out biochemical reactions and act as structural components in cells. The appreciation of the important roles that trace elements, especially metals, play in cell metabolism has resulted in an increase in the number of studies in this area1,2,3,4,5. However, to truly understand the functions of trace elements in cells and tissues, the distribution within a cell must be imaged and quantified in the native cellular environment, which has proven to be difficult.
Hard XRF microscopy is a well-suited microanalytical technique for assessing the elemental distribution in a wide range of materials including whole cells and tissues6,7,8. In XRF microscopy, multiple elements can be mapped simultaneously, which provides precise elemental co-localization and speciation. High detection sensitivity down to sub-parts-per-million has been demonstrated in biological studies9,10.
To understand the functions of trace elements in biological cells, the X-ray probe must resolve subcellular compartments on the sub-micron to nanometer scale such as mammalian nuclei, mitochondria, and cell membranes, which measure ~6 μm, ~1 μm and ~10 nm, respectively11. In prokaryotic cells such as E. coli (1 μm × 3 μm), the outer and inner cell membranes are each ~10–15 nm wide, while ribosomes are about 20 nm in size12.
Nanoscale imaging with X-rays requires high-resolution nano-focusing optics like Kirkpatrick-Baez mirrors13,14,15 and Fresnel zone plate optics16. A more sophisticated, higher-resolving, nano-focusing approach is to use Multilayer Laue Lenses (MLLs)17,18,19, incorporated into a specialized X-ray microscope located at a beamline with infrastructure for good vibration isolation and thermal stability20,21,22.
It is well-accepted that X-ray imaging of living biological specimens can be a challenge due to radiation-induced damage, so cells are frequently imaged in the fixed/dried or frozen-hydrated state23. While fixed/dried cells are least subject to radiation damage from water hydrolysis and free radical production, the subcellular structure can be compromised, especially at the nanoscale. Frozen-hydrated cells represent the most natural state of the cell while reducing the effects of radiation damage; however, this method requires the cells to be flash frozen, e.g. with a plunge freezer, and imaged in a cryostage. Since optical configurations of nanotomography instruments with MLLs21 have very short working distances and rotation constraints, integration of a cryostage is a significant technical challenge. In addition, since the trace elements are typically micro- to nanomolar in concentration, sensitive detectors with a large solid angle situated close to the sample are required for quantification, further increasing technical complexity.
Whereas two-dimensional XRF microscopy is the most straightforward approach for imaging cells and tissues, these two-dimensional data can be ambiguous when imaging three-dimensional objects, e.g. when aiming to differentiate between elements located on the surface of a cell from those distributed throughout the cell. At present, only a few three-dimensional XRF tomography studies from whole biological specimens have been reported. Kim et al. have studied the role of the vacuolar iron uptake transporter in the uptake and distribution of iron in the Arabidopsis seed, which was performed at 12 μm spatial resolution24. More recently, de Jonge et al. performed three-dimensional XRF tomography of a whole diatom, Cyclotella meneghiniana, at 400 nm spatial resolution using 150 nm voxels over a 15 μm field of view9. This work elegantly showed the distribution of several species including silicon and zinc within the organelles including the siliceous frustule, a diatom’s cell wall. Most surprising was the detection of Fe and Mn rings in the cell wall that would not have been detectable using only two-dimensional projections.
To date, XRF nanotomography has been limited by sub-micron spatial resolution and weak absorption contrast in biological cells, inhibiting its ability to distinguish the ultra-structures of cell organelles25. In contrast, coherent diffraction imaging techniques, such as ptychography, can be used to image the fine structural components in samples26 but cannot determine the distribution of trace elements. However, by combining XRF nanotomography and ptychography, it is possible to obtain complementary data on elemental and structural composition, respectively, at the nanoscale from biological cells8,27. The results described here represent a combination of two-dimensional ptychography and XRF nanotomography performed on E. coli cells using a MLL microscope with a sub-15 nm focused beam.
Methods
Cell culture
LB media (10 mL) was inoculated with a single colony of BL21 (DE3) E. coli cells and the culture grown at 37 °C with shaking to an OD of 0.6–0.8. Cells were harvested in 1 mL aliquots via centrifugation at 3,500 RPM, flash frozen in liquid nitrogen, and stored at −80 °C.
Sample preparation, light microscopy and scanning electron microscopy
A 20 μl solution containing 2 μM NaCl, 0.01 OD E. coli cells, and 0.025 OD 100 nm gold nanoballs (CytoDiagnostics, #GRF-100-20) was mixed thoroughly. The gold nanoballs were added as fiducial markers for the tomography reconstruction. One microliter of this solution was pipetted onto a silicon chip sample holder with Cr fiduciary grids (Fig. 1C,D), also known as a “diving board” (substrate area 1.4 mm by 0.4 mm with a 10 μm thickness) (Norcada NCT4155P-III-Cr), and allowed to dry overnight. The diving board was then glued onto a stainless-steel insect pin (0.2 mm thick, 16.5 mm tall) (Fig. 1C) and mounted on the sample mount (Fig. 1B) for the X-ray microscope (Fig. 1A). The diving board has 5 μm wide chromium-patterned gridlines for sample alignment in the X-ray microscope. Images of cells prepared on the diving boards were taken using both a visible light microscope (Nikon Eclipse LVDIA-N) and a scanning electron microscope (SEM, JEOL 300) for cell identification, correlation, and navigation during data acquisition at the beamline.
Synchrotron X-ray fluorescence microscopy and ptychography measurements
The distribution of elements was mapped using nano-Mii (Nanoscale Multimodal Imaging Instrument) at beamline 3-ID (HXN) at the National Synchrotron Light Source II (Fig. 1A). Beamline 3-ID provides a scanning X-ray microscope capable of multimodal imaging including absorption, fluorescence, differential phase contrast, and ptychography28. In this study, a 12 keV incident beam was focused to a sub-15 nm spot (14 nm horizontal and 12 nm vertical) using Multilayer Laue Lenses (MLLs). The coherent illumination was selected by a 50 × 30 µm secondary source aperture placed about 15 m in front of the nanofocusing optics. A three-element silicon drift detector (Vortex-ME3) was placed perpendicular to the incident beam to collect the fluorescence signals, and the transmitted scattering data for differential phase contrast or ptychography reconstructions were acquired by using a pixelated area detector (Merlin) with a pixel size of 55 µm at a distance of 0.5 m downstream the sample.
Two-dimensional fluorescence/ptychography scans, via continuous fly-scan, were performed using a step size of 20 nm/pixel and a dwell time of 250 ms. For the tomography data set, the cells were scanned from -39 to 132 degrees at 3 degree intervals using a dwell time of 100 ms and a 20 nm step size. Each projection was ~14 min. After each rotation interval, a short coarse scan (~1 min) was used to center the sample in the field of view of the projection image, resulting in a total imaging time for a complete cell of approximately 15 hours, excluding overhead.
The fitting of the X-ray fluorescence data was accomplished using PyXRF, an X-ray fluorescence analysis package developed at NSLS-II29. For the fitting process, the summed spectrum was first fitted using the non-linear least squares method to determine the global parameters such as the energy-calibration values, widths of the global peaks, and parameters related to the Compton and elastic peaks. Once the correct global parameters were obtained, the peak area of each element under the XRF spectrum of each single pixel was then fitted using a nonnegative least squares approach. TomoPy was used for the tomography reconstruction of the data sets30. The projection images were aligned by calculating the cross-correlation of a pair of images taken at successive projection angles. The aligned image stack was reconstructed using the maximum-likelihood method coded in the TomoPy package30, and 20 iterations were used to reconstruct each slice. To correct for any attenuation (due to the thickness of the diving board, since the XRF photons are detected through the diving board for some projections), the total intensity of the Zn fluorescence images was normalized to be constant for all the images taken at different projection angles.
For the ptychography reconstruction, a 96 × 96 array was cropped from the recorded raw dataset, which gave a reconstruction pixel size of about 10 nm. The cropped data array was fed into 100 iterations of a difference map algorithm for ptychography reconstruction31. From the preliminary reconstruction result, we noticed that the measurement was not performed exactly at the focal plane (due to run-out error of the rotary stage). In order to achieve the best reconstruction image quality, the exact illumination function at the measurement plane was searched by running the reconstruction process using a series of propagated wavefronts as the initial probe guesses, and the one that gave the best contrast was selected. A series of illumination functions propagated to various distances from the focus were tested, and the one that gave the best reconstruction image quality was selected. To assist the reconstruction convergence, the allowable ranges for the amplitude and phase parts of the E. coli image were constrained to [0.95, 1.0] and [−0.1, 0.0], respectively. The last 20 iterations were averaged to give the final reconstructed image.
Results
E. coli cells were deposited on the diving board and examined under a visible light microscope in epi-brightfield mode followed by visualization using SEM. The SEM image (Fig. 2A) displays E. coli cells (typically 1 μm × 3 μm in size) embedded in small sodium chloride crystals (3–20 μm) that formed on the silicon substrate, where the cells appear as dark (negative contrast) regions in the crystals. The inset in Fig. 2A shows a magnified view of a group of cells lined up side-by-side within a sodium chloride crystal.
Two-dimensional elemental images (Fig. 2B–E) were taken using XRF microscopy, mapping the distribution and co-localization of zinc, calcium, and chlorine. The chlorine image (Fig. 2D) shows the location of the sodium chloride crystals and the dark regions indicate the areas occupied by the cells embedded in the crystal, which correlates well with the SEM image in Fig. 2A (inset). Most notably, zinc exhibits an inhomogeneous distribution (Fig. 2B) whereas a more uniform distribution of calcium (Fig. 2C) is observed throughout the cell. An XRF spectrum showing elements present in the sample is seen in Fig. 2F. It should be noted that peaks from Fe, Ni, and W are contributions from the microscope, the Cr signal arises from the bars on the substrate, and the Au signal comes from the nanoball fiducials.
In Fig. 3A, the two-dimensional zinc distribution is shown in a series of two cells lined end-to-end. Again, the distribution of zinc is uneven within the cells and varies from cell to cell. The gold elemental map (Fig. 3B) was used to localize the gold nanoballs, which were added to the cell solution as fiducial markers for the alignment and reconstruction of the tomography data. These gold nanoballs are also visible in the ptychography reconstructed phase image (Fig. 3C) along with the clear outline of two cells that appear to be dividing. An overlay of the ptychography and XRF images can be seen in Fig. 3D. It should be noted that the edge enhanced contrast in the ptychography image is most likely due to the propagation uncertainty along the beam direction32. As the reconstruction plane in the ptychography method is determined by the illumination function26, the object transmission functions that propagate within the depth of focus range (±2 μm for MLLs) are allowed in the phase-retrieval process. For an object with extremely small contrast, which is the case for this study, the edge-enhanced artifact is more pronounced than the objects with higher contrast.
The zinc distribution was further investigated in a three-dimensional XRF nanotomography dataset of a single E. coli cell (Fig. 4). The tomography reconstruction in Fig. 4A as well as the 2D cut in Fig. 4C clearly show that zinc is inhomogeneously distributed throughout the cell. The 2D cut through the cell in Fig. 4B shows that Zn is heavily concentrated at one pole of the cell.
Since bacteria do not have many well-defined subcellular structures, the spatial resolution of the two-dimensional XRF images was estimated using a power spectral analysis27,33. According to Deng et al., for low-photon statistics images like XRF images, one can use the fact that Poisson fluctuations (‘shot noises’) are uncorrelated from pixel to pixel so that, at high spatial frequencies, one arrives at a noise floor in Fourier power analysis. Figure 5 shows the result of the power spectral analysis, where we found an estimated spatial resolution of approximately 36 nm (horiz) × 36 nm (vert) using the 2D zinc fluorescence image from the tomography projection at 15°.
Another method to estimate the spatial resolution is by using the Fourier Ring Calculation approach which requires two independent datasets acquired under the same conditions34,35. Based on previously published work22, the beam size routinely produced by the MLLs is about 14 nm x 12 nm when performed with 2D imaging using a well-aligned sample. This results in a depth of focus of ±2 μm for the HXN MLL microscope. However, the rotation stage used for these experiments had a poor run-out error of ~5 μm. Thus, for some rotation angles, the sample moved away from its ideal rotation center. Although the sample was centered in the direction perpendicular to the beam, the run out along the direction parallel to the beam was not corrected. Considering these factors, the XRF image resolution in this study was larger than the published work by Yan, et al.22.
Discussion
In this study, X-ray fluorescence microscopy, nanotomography, and ptychography were performed on individual E. coli cells using a sub-15 nm beam size with a MLL microscope. The distributions of chlorine, calcium, and zinc were imaged, focusing on the sub-cellular distribution of zinc in the cell. E. coli cells have few internal structures; they possess a nucleoid, which is a highly condensed and membrane-free, irregular structure containing the genetic material of the bacterial cell36,37 and a dense distribution of ribosomes. The tomography results showed an inhomogeneous zinc distribution in the cell, with a higher concentration at one pole. Most of the internal labile zinc is thought to be stored in the ribosomes38,39,40. Generally, ribosomes are distributed among and around the central nucleoid. This ribosome distribution leads to ribosome-rich regions especially at the polar end-caps of the cell and in a cylindrical shell surrounding the nucleoid36 which would explain the higher amounts of zinc observed in these regions39,40,41.
In rapidly growing E. coli, it is believed that the majority of the translation events are presumably carried out on mature, freely diffusing mRNAs within this localized ribosome-rich, “protein-factory” region using poly-ribosomes42. In bacteria, zinc can play a structural, regulatory, or catalytic role in proteins and is tightly controlled by dedicated systems for high-affinity zinc uptake and export systems involving the cell membranes40,43.
One of the challenges of using a MLL microscope is the short working distance between the sample position and the order-sorting aperture (OSA), which was ~0.8 mm in this experiment. Because there is a short working space available to rotate the sample to collect XRF maps at different angles, it was necessary to have a sample and substrate small enough to prevent sample collision with the OSA. To mitigate this, several iterations of sample holders were tested including Mitegen’s Microcrystal MountsTM, direct addition of the cells embedded in NaCl crystals to a tungsten pin, and different sizes of the HXN diving board Si-chip sample holder. In the end, we chose a Si-chip substrate that was less than 0.5 mm wide, which was small enough to safely rotate the sample but large enough to accommodate more than 100 cells for the experiment.
A further limitation of nanoscale X-ray imaging, in particular for living biological specimens, is the inherent radiation damage that occurs with hard X-ray exposure, which can change the structure and chemistry of samples. Generally, samples are measured dried or under cryogenic conditions to mitigate chemical and structural changes when exposed to an intense X-ray beam. With the short working distance of the MLL microscope, sample transfer and data collection at cryogenic conditions presented a significant technical challenge. Instead, we chose to embed the bacteria in small (5–20 µm wide, 1–2 µm thick) sodium chloride crystals, which was a simple and straightforward approach to provide a non-aqueous matrix that retained the three-dimensional structure of individual cells. Furthermore, the XRF and SEM contrast provided by chlorine greatly enhanced the ability to locate individual cells on the sample substrate, also minimizing the radiation dose. While this method may not be applicable to all cells, it is likely to be most effective for many nonadherent cell types including bacteria, archaea, and algae that can easily be suspended in the salt solution prior to drying.
The estimated radiation dose imparted on the sample for the duration of the tomography data collection was 1.3 × 109 Gray. No signs of cell shrinkage or compositional changes were observed. This dose was calculated assuming the main consistency of the cell material was of protein composition of H48.6C32.9N8.9O8.9S0.6 with a condensed density of 1.35 g/cm3 44,45. This dosage was similar to those imparted on biological samples reported by others without seeing any significant mass loss33,46, albeit these studies were done under cryogenic conditions.
Having the ability to assess the zinc distribution in E. coli – as is possible with XRF nanotomography – is essential for establishing the role of zinc in cellular processes and disease. Importantly in bacteria, infectivity can readily be altered by varying levels of zinc in the host system47. More broadly, zinc plays a vital role in the physiology of all organisms and its homeostasis is widely studied in areas such as aging, neurodegenerative diseases, cancer, the immune system, and energy metabolism.
This work represents one example of how XRF nanotomography and ptychography can be used to image trace element distribution/concentration and structural morphology, respectively, in biological cells. It was made possible through the development of a synchrotron source with high brightness and coherence, nanofocusing optics, and exceptional beam and sample stability along with a new approach for sample preparation and image collection.
Conclusions
In summary, this study demonstrates that XRF nanotomography can be used to image the distribution of trace elements in intact biological cells using a sub-15 nm beam in three dimensions, and that simultaneous ptychography can be used for the co-localization of the trace elements with subcellular structures. An approach such as this presents new possibilities in understanding subcellular biochemistry in individual organelles and other subcellular compartments, which are usually analyzed at the organelle population level.
References
Kashiv, Y. et al. Imaging trace element distributions in single organelles and subcellular features. 6, 21437, https://doi.org/10.1038/srep21437 (2016).
Hagmeyer, S., Mangus, K., Boeckers, T. M. & Grabrucker, A. M. Effects of Trace Metal Profiles Characteristic for Autism on Synapses in Cultured Neurons. Neural Plasticity 2015, 985083, https://doi.org/10.1155/2015/985083 (2015).
Wu, Y. et al. Quantitative Relationship between Cadmium Uptake and the Kinetics of Phytochelatin Induction by Cadmium in a Marine Diatom. Scientific Reports 6, 35935, https://doi.org/10.1038/srep35935 (2016).
Cristóvão, J. S. et al. Metals and Neuronal Metal Binding Proteins Implicated in Alzheimer’ s Disease. Oxidative Medicine and Cellular Longevity 2016, 13, https://doi.org/10.1155/2016/9812178 (2016).
Colvin, R. A., Jin, Q. & Lai, B. & Kiedrowski, L. Visualizing Metal Content and Intracellular Distribution in Primary Hippocampal Neurons with Synchrotron X-Ray Fluorescence. PLoS ONE 11, e0159582, https://doi.org/10.1371/journal.pone.0159582 (2016).
Fahrni, C. J. Biological applications of X-ray fluorescence microscopy: exploring the subcellular topography and speciation of transition metals. Current Opinion in Chemical Biology 11, 121–127, https://doi.org/10.1016/j.cbpa.2007.02.039 (2007).
de Jonge, M. D. & Vogt, S. Hard X-ray fluorescence tomography—an emerging tool for structural visualization. Current Opinion in Structural Biology 20, 606–614, https://doi.org/10.1016/j.sbi.2010.09.002 (2010).
Yan, H. et al. Multimodality hard-x-ray imaging of a chromosome with nanoscale spatial resolution. Scientific Reports 6, 20112, https://doi.org/10.1038/srep20112 (2016).
de Jonge, M. D. et al. Quantitative 3D elemental microtomography of Cyclotella meneghiniana at 400-nm resolution. Proceedings of the National Academy of Sciences 107, 15676–15680, https://doi.org/10.1073/pnas.1001469107 (2010).
Punshon, T., Guerinot, M. L. & Lanzirotti, A. Using synchrotron X-ray fluorescence microprobes in the study of metal homeostasis in plants. Annals of Botany 103, 665–672, https://doi.org/10.1093/aob/mcn264 (2009).
Chaffey, N. et al. Molecular biology of the cell. 4th edn. Annals of Botany 91, 401–401, https://doi.org/10.1093/aob/mcg023 (2003).
Milo, R., Jorgensen, P., Moran, U., Weber, G. & Springer, M. BioNumbers—the database of key numbers in molecular and cell biology. Nucleic Acids Research 38, D750–D753, https://doi.org/10.1093/nar/gkp889 (2010).
Kazuto, Y. et al. Single-nanometer focusing of hard x-rays by Kirkpatrick–Baez mirrors. Journal of Physics: Condensed Matter 23, 394206 (2011).
Liu, W. et al. Short focal length Kirkpatrick-Baez mirrors for a hard x-ray nanoprobe. Review of Scientific Instruments 76, 113701, https://doi.org/10.1063/1.2125730 (2005).
Kujala, N. et al. Kirkpatrick-Baez mirrors to focus hard X-rays in two dimensions as fabricated, tested and installed at the Advanced Photon Source. Journal of synchrotron radiation 21, 662–668, https://doi.org/10.1107/s1600577514006493 (2014).
Vila-Comamala, J. et al. Ultra-high resolution zone-doubled diffractive X-ray optics for the multi-keV regime. Optics Express 19, 175–184, https://doi.org/10.1364/OE.19.000175 (2011).
Huang, X. et al. 11 nm hard X-ray focus from a large-aperture multilayer Laue lens. Scientific Reports 3, 3562, https://doi.org/10.1038/srep03562 (2013).
Morgan, A. J. et al. High numerical aperture multilayer Laue lenses. Scientific Reports 5, 9892, https://doi.org/10.1038/srep09892 (2015).
Bajt, S. et al. X-ray focusing with efficient high-NA multilayer Laue lenses. Light: Science & Applications 7, 17162, https://doi.org/10.1038/lsa.2017.162 (2018).
Nazaretski, E. et al. Pushing the limits: an instrument for hard X-ray imaging below 20 nm. Journal of Synchrotron Radiation 22, 336–341, https://doi.org/10.1107/S1600577514025715 (2015).
Nazaretski, E. et al. Design and performance of an X-ray scanning microscope at the Hard X-ray Nanoprobe beamline of NSLS-II. J Synchrotron Radiat 24, 1113–1119, https://doi.org/10.1107/s1600577517011183 (2017).
Yan, H. et al. Multimodal hard x-ray imaging with resolution approaching 10 nm for studies in material science. Nano Futures 2, 011001 (2018).
Nam, D. et al. Imaging Fully Hydrated Whole Cells by Coherent X-Ray Diffraction Microscopy. Physical Review Letters 110, 098103 (2013).
Kim, S. A. et al. Localization of iron in Arabidopsis seed requires the vacuolar membrane transporter VIT1. Science 314, 1295–1298, https://doi.org/10.1126/science.1132563 (2006).
Yamamoto, Y. & Shinohara, K. Application of X-ray microscopy in analysis of living hydrated cells. The Anatomical Record 269, 217–223, https://doi.org/10.1002/ar.10166 (2002).
Robinson, I. & Huang, X. X-ray imaging: Reaching the third dimension. Nat Mater 16, 160–161, https://doi.org/10.1038/nmat4845 (2017).
Deng, J. et al. X-ray ptychographic and fluorescence microscopy of frozen-hydrated cells using continuous scanning. Scientific Reports 7, 445, https://doi.org/10.1038/s41598-017-00569-y (2017).
Chu, Y. et al. Hard x-ray nanoprobe facility at the National Synchroton Light Source II. SPIE Newsroom, https://doi.org/10.1117/2.1201508.006068 (2015).
Li, L. et al. PyXRF: Python-based X-ray fluorescence analysis package. Proc. SPIE 10389, X-Ray Nanoimaging: Instruments and Methods III 10389, https://doi.org/10.1117/12.2272585 (2017).
Gürsoy, D., De Carlo, F., Xiao, X. & Jacobsen, C. TomoPy: A framework for the analysis of synchrotron tomographic data. Proc. SPIE 9212, Developments in X-Ray Tomography IX, 92120N 9212, https://doi.org/10.1117/12.2061373 (2014).
Huang, X. et al. Fly-scan ptychography. Scientific Reports 5, 9074, https://doi.org/10.1038/srep09074 (2015).
Huang, X., Harder, R., Xiong, G., Shi, X. & Robinson, I. Propagation uniqueness in three-dimensional coherent diffractive imaging. Physical Review B 83, 224109, https://doi.org/10.1103/PhysRevB.83.224109 (2011).
Deng, J. et al. Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae. Proceedings of the National Academy of Sciences 112, 2314 (2015).
van Heel, M. & Schatz, M. Fourier shell correlation threshold criteria. Journal of Structural Biology 151, 250–262, https://doi.org/10.1016/j.jsb.2005.05.009 (2005).
Vila-Comamala, J. et al. Characterization of high-resolution diffractive X-ray optics by ptychographic coherent diffractive imaging. Optics Express 19, 21333–21344, https://doi.org/10.1364/OE.19.021333 (2011).
Bakshi, S., Siryaporn, A., Goulian, M. & Weisshaar, J. C. Superresolution Imaging of Ribosomes and RNA Polymerase in Live Escherichia coli Cells. Molecular Microbiology 85, 21–38, https://doi.org/10.1111/j.1365-2958.2012.08081.x (2012).
Chai, Q. et al. Organization of Ribosomes and Nucleoids in Escherichia coli Cells during Growth and in Quiescence. Journal of Biological Chemistry 289, 11342–11352, https://doi.org/10.1074/jbc.M114.557348 (2014).
Hensley, M. P., Tierney, D. L. & Crowder, M. W. Zn(II) binding to E. coli 70S Ribosomes. Biochemistry 50, 9937–9939, https://doi.org/10.1021/bi200619w (2011).
Blindauer, C. A. Advances in the molecular understanding of biological zinc transport. Chemical Communications 51, 4544–4563, https://doi.org/10.1039/C4CC10174J (2015).
Takahashi, H. et al. The dynamic balance of import and export of zinc in <em> Escherichia coli </em>suggests a heterogeneous population response to stress. Journal of The Royal Society Interface 12, https://doi.org/10.1098/rsif.2015.0069 (2015).
Dillon, S. C. & Dorman, C. J. Bacterial nucleoid-associated proteins, nucleoid structure and gene expression. Nat Rev Micro 8, 185–195 (2010).
Bakshi, S., Choi, H. & Weisshaar, J. C. The spatial biology of transcription and translation in rapidly growing Escherichia coli. Frontiers in Microbiology 6, https://doi.org/10.3389/fmicb.2015.00636 (2015).
Ma, Z. & Jacobsen, F. E. & Giedroc, D. P. Metal Transporters and Metal Sensors: How Coordination Chemistry Controls Bacterial Metal Homeostasis. Chemical reviews 109, 4644–4681, https://doi.org/10.1021/cr900077w (2009).
London, R. A., Rosen, M. D. & Trebes, J. E. Wavelength choice for soft x-ray laser holography of biological samples: errata. Applied Optics 28, 4981_4981-4981_4981, https://doi.org/10.1364/AO.28.4981_1 (1989).
Howells, M. R. et al. An assessment of the resolution limitation due to radiation-damage in x-ray diffraction microscopy. Journal of electron spectroscopy and related phenomena 170, 4–12, https://doi.org/10.1016/j.elspec.2008.10.008 (2009).
Schneider, G. Cryo X-ray microscopy with high spatial resolution in amplitude and phase contrast. Ultramicroscopy 75, 85–104, https://doi.org/10.1016/S0304-3991(98)00054-0 (1998).
Djoko, K. Y., Ong, C.-lY., Walker, M. J. & McEwan, A. G. The Role of Copper and Zinc Toxicity in Innate Immune Defense against Bacterial Pathogens. The Journal of Biological Chemistry 290, 18954–18961, https://doi.org/10.1074/jbc.R115.647099 (2015).
Acknowledgements
This work was supported by the United States Department of Energy, Office of Biological and Environmental Research, as part of the “Environment Sensing and Response” Scientific Focus Area of the BER Genomic Science Program. TWV was partially supported by the National Institutes of Health T32 Grant 5T32GM092714. This research used resources of beamline 3-ID (HXN) at NSLS-II, a U.S. Department of Energy (DOE) Office of Science User Facilities operated for the DOE Office of Science by Brookhaven National Laboratory under Contract No. DE-SC0012704. We acknowledge the National Science Foundation Collaborative Research program (MCB-1614608/1615253 to K.N.A.). The authors thank Dr. Doga Gursoy at the Advanced Photon Source for providing technical support and consultation for reconstructing the XRF tomography dataset.
Author information
Authors and Affiliations
Contributions
L.M.M., Y.S.C. and T.W.V. designed the experiments. L.M.E., K.H.O. and K.N.A. prepared the samples. T.W.V., R.J.S., M.G., X.H., H.Y., Y.S.C. and L.M.M. collected and analyzed the data. T.W.V. and L.M.M. wrote the manuscript text and prepared Figures 1–5. All authors reviewed the manuscript.
Corresponding author
Ethics declarations
Competing Interests
The authors declare no competing interests.
Additional information
Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Victor, T.W., Easthon, L.M., Ge, M. et al. X-ray Fluorescence Nanotomography of Single Bacteria with a Sub-15 nm Beam. Sci Rep 8, 13415 (2018). https://doi.org/10.1038/s41598-018-31461-y
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-018-31461-y
- Springer Nature Limited
This article is cited by
-
Multielement Z-tag imaging by X-ray fluorescence microscopy for next-generation multiplex imaging
Nature Methods (2023)
-
Sub-10 second fly-scan nano-tomography using machine learning
Communications Materials (2022)
-
Nucleoid remodeling during environmental adaptation is regulated by HU-dependent DNA bundling
Nature Communications (2020)
-
Spectroscopic imaging with single acquisition ptychography and a hyperspectral detector
Scientific Reports (2019)