Abstract
In optics, the ability to measure individual quanta of light (photons) enables a great many applications, ranging from dynamic imaging within living organisms1 to secure quantum communication2. Pioneering photon counting experiments, such as the intensity interferometry performed by Hanbury Brown and Twiss3 to measure the angular width of visible stars, have played a critical role in our understanding of the full quantum nature of light4. As with matter at the atomic scale, the laws of quantum mechanics also govern the properties of macroscopic mechanical objects, providing fundamental quantum limits to the sensitivity of mechanical sensors and transducers. Current research in cavity optomechanics seeks to use light to explore the quantum properties of mechanical systems ranging in size from kilogram-mass mirrors to nanoscale membranes5, as well as to develop technologies for precision sensing6 and quantum information processing7,8. Here we use an optical probe and single-photon detection to study the acoustic emission and absorption processes in a silicon nanomechanical resonator, and perform a measurement similar to that used by Hanbury Brown and Twiss to measure correlations in the emitted phonons as the resonator undergoes a parametric instability formally equivalent to that of a laser9. Owing to the cavity-enhanced coupling of light with mechanical motion, this effective phonon counting technique has a noise equivalent phonon sensitivity of 0.89 ± 0.05. With straightforward improvements to this method, a variety of quantum state engineering tasks using mesoscopic mechanical resonators would be enabled10, including the generation and heralding of single-phonon Fock states11 and the quantum entanglement of remote mechanical elements12,13.
Similar content being viewed by others
Main
Measurement of the properties of mechanical systems in the quantum regime typically involves heterodyne detection of a coupled optical or electrical field, yielding a continuous signal proportional to the displacement amplitude14. An alternative method, particularly suited to optical read-out, is to utilize photon counting as a means to probe the quantum dynamics of the coupled optomechanical system15,16. Photon counting can be readily adapted to study intensity correlations in an optical field, and has been used not only in the astronomical studies of thermal light using the technique of Hanbury Brown and Twiss (HBT), but also in early studies of the photon statistics of laser light and single-atom fluorescence4,17. In the field of photon-correlation spectroscopy, such intensity interferometry techniques have found widespread application in the measurement of particle and molecular motion in materials18. More recently, photon counting of Raman scattering events in diamond has heralded and verified the quantum entanglement of a terahertz phonon shared between two separate bulk diamond crystals13. In the case of engineered cavity optomechanical systems, much longer phonon coherence times are attainable, albeit at lower mechanical frequencies (megahertz to gigahertz), which limit the temperature of operation and the optical power handling capability of such structures. Quantum optical schemes for manipulation of the quantum state of motion in cavity optomechanical systems thus rely on a large per-phonon scattering rate and efficient detection of scattering events. Here we embed a high-Q, gigahertz-frequency mechanical resonator inside an optical nanocavity, greatly enhancing the phonon–photon coupling rate and channelling optical scattering into a preferred optical mode for collection. Single-photon detection of this scattered light then allows for a precise counting of single-phonon emission or absorption events, effectively phonon counting (although this terminology should not be confused with Fock state detection or quantum non-demolition measurement of phonon number). The highly engineered and optimized nature of this optomechanical resonator furthermore yields a sub-phonon-level counting sensitivity of the intracavity mechanical resonator occupancy.
A conceptual schematic of the phonon counting experiment is shown in Fig. 1a. The device consists of a patterned silicon nanobeam which forms an optomechanical crystal (OMC)19,20 able to co-localize acoustic (mechanical) and optical resonances at frequencies ωm and ωc, respectively. Finite-element-method simulations of the acoustic and optical resonances are shown at the top of Fig. 1a. The Hamiltonian describing the interaction between the acoustic and optical modes is given by , where is the annihilation operator for the optical (acoustic) mode, and g0 is the optomechanical coupling rate, physically representing the optical frequency shift due to the zero-point motion of the acoustic resonator. This interaction modulates a laser probe with frequency ωl to produce sidebands at frequencies ωl ± ωm, analogous to the anti-Stokes and Stokes sidebands in Raman scattering and corresponding to phonon absorption or emission, respectively. For a system in the resolved sideband limit, where (κ is the linewidth of the optical resonance), the density of states of the optical cavity can be used to resonantly enhance either scattering process for an appropriately detuned pump. In particular, applying a large coherent pump red (blue) detuned from the optical cavity resonance by Δ = ωc − ωl = ωm (Δ = −ωm) results in an effective interaction Hamiltonian of the form (), where is the parametrically enhanced optomechanical coupling rate (nc is the intracavity photon number at frequency ωl due to the pump laser). In this case, the output field annihilation operator can be shown to consist of a coherent component at frequency ωl as well as a component at frequency ωc which is proportional to (ref. 21). Sending the cavity output through a series of narrowband optical filters centred on the cavity resonance, as shown in Fig. 1a, suppresses the pump so that photon counting events will correspond directly to counting phonon absorption (emission) events22. Subsequently directing the filter output to an HBT set-up in order to measure the second-order photon correlation function g(2)(τ) (ref. 3) will then result in a direct measurement of the normally (anti-normally) ordered second-order phonon correlation function. Although this work deals with measurements of a particular cavity optomechanical system, the nanobeam OMC, numerous other geometries possess the requisite optomechanical coupling strength and high mechanical frequency necessary to implement this phonon counting scheme5.
As described in ref. 20, the nanobeam is patterned in such a way as to support a ‘breathing’ acoustic resonance at ωm/2π = 5.6 GHz as well as a fundamental optical resonance at a free-space wavelength near 1,550 nm, with a theoretical vacuum coupling rate of g0/2π = 860 kHz. All measurements presented here are performed at room temperature and pressure. The thermal Brownian motion of the acoustic resonance manifests as a Lorentzian response centred around ωm in the noise power spectral density (NPSD), S(ω), of the cavity reflection photocurrent, as shown in Fig. 1b. The linewidth of this Lorentzian is γ = γi + γOM, where γi is the intrinsic acoustic energy damping rate and γOM = ±4G2/κ is the optomechanically induced damping rate due to dynamical back action when pumping on the red or blue sideband, respectively21. By measuring this linewidth as a function of nc for both red and blue detuning, we extract γi/2π = 3 MHz and g0/2π = 645 kHz. The optical cavity reflection spectrum shown in Fig. 1c reveals a total optical energy decay rate of κ/2π = 817 MHz and a decay rate into the detection channel of κe/2π = 425 MHz.
To determine the feasibility of the phonon counting scheme for measurements of the OMC in the quantum regime, one must determine the signal-to-noise ratio (SNR). While the signal level depends on the above-measured optomechanical cavity parameters as well as the overall efficiency of photon detection, any detection events that do not correspond to Raman-scattered sideband photons will contribute as noise. These noise counts originate in dark counts of the single-photon detectors (SPDs) and photodetection of light at frequencies other than ωc, most notably in the unscattered portion of the laser pump. Two cascaded tunable, commercially available Fabry–Perot filters (Micron Optics, FFP-TF2), with bandwidths of 50 MHz and free spectral ranges of 20 GHz, are used to attenuate the laser pump by a factor A > 80 dB relative to the peak transmission at ωc (see Fig. 1d). The transmission of the filters is then detected in the HBT apparatus by WSi-based superconducting nanowire SPDs23 operating at a system detection efficiency of ηSPD ≈ 70% and a dark count rate of Γdark = 4 Hz.
A useful parameterization of these quantities is the amount of noise (in units of mechanical occupation quanta) as a proportion of the signal generated by a single phonon in the OMC. Alternatively, this noise-equivalent phonon number nNEP can be interpreted as the mechanical occupation which would produce an SNR of 1. We obtain nNEP then by dividing the noise count rates by the per-phonon sideband photon count rate ΓSB,0 = η|γOM|, where η is the total efficiency of the set-up, including the system efficiency of the SPDs as well as optical insertion loss along the path from cavity to detector. For a coherent pump, this yields:
The above equation makes clear the benefits of large cavity-enhanced optomechanical coupling g0, both in terms of the low power sensitivity limited by detector dark counts and the high power sensitivity limited by pump bleed-through. Further details about the detection set-up, optical and mechanical spectroscopy, and derivation of nNEP can be found in the Supplementary Information.
In Fig. 2a we show the measured sensitivity of the phonon counting set-up for Δ = ωm (filled grey circles), as well as the expected theoretical curve (dashed line) given by equation (1). The noise count rate is measured with the pump beam detuned far off-resonance from the optical cavity, , which eliminates the signal due to motional sideband photons but does not change the reflected pump signal or SPD dark counts. To determine ΓSB,0, the sideband count rate is measured at low nc where back action is negligible and the mechanical mode occupancy 〈n〉 is equal to the room temperature thermal bath occupancy of nb ≈ 1,100. Since ΓSB,0 scales linearly with nc, we can determine ΓSB,0 for all nc from this single measurement without relying on calibration of the optomechanical back action. We can then compute nNEP by dividing this noise count rate by ΓSB,0 at each value of nc. The measured sensitivity follows the expected curve at low power due to detector dark counts (solid red curve), but at high nc saturates to a value several times larger than expected for the filter suppression of the pump (solid blue curve). In order to better understand this excess noise, Fig. 2b shows measurements of the nNEP as a function of filter–pump detuning, Δfilter, at a high power where the pump transmission dominates the noise (nc ≈ 65). A strong dependence on Δfilter is observed, with a peak in the noise at 5 GHz and a secondary peak at 6.1 GHz, consistent with the phase noise of our pump laser21. With the addition of a C-band bandpass filter before the SPD to remove broadband spontaneous emission from the pump laser, and at frequencies far from the laser phase-noise peaks, the measured nNEP agrees well with the theoretical predictions based on the filter pump suppression (horizontal dashed curve). At the relevant detuning of Δfilter = ωm (vertical dashed curve), we measure a limiting sensitivity of nNEP = 0.89 ± 0.05. While this sensitivity is directly measured at nc ≈ 65, nNEP is observed in Fig. 2a to be pump-limited for , implying that our current set-up achieves nNEP < 1 for nc of order unity.
In what follows, we focus on measurements made with a blue-detuned pump (Δ = −ωm), in which the optomechanical back action results in instability and self-oscillation of the acoustic resonator9,21. The Stokes sideband count rate detected on a single SPD, shown versus nc in Fig. 3a, displays a pronounced threshold, with an exponential increase in output power beginning at nc ≈ 1,200, where C ≡ |γOM|/γi ≈ 0.8, in agreement with the expected onset of instability around C = 1 (γ = 0). This sharp oscillation threshold can also be observed from the measured noise power spectral density (NPSD; Fig. 3b), in which the amplitude of the mechanical spectrum is seen to rapidly increase with a simultaneous reduction in linewidth, and in plots of the in-phase and in-quadrature components of the photocurrent fluctuations, which show a transition from thermal noise to a large-amplitude sinusoidal oscillation. Also shown in Fig. 3a is the inferred phonon occupancy 〈n〉. Below threshold, the photon count rate is related to 〈n〉 via the simple linear relation Γtot = η|γOM|(〈n〉 + 1). At and above threshold, as detailed in the Supplementary Information, self-consistent determination of the oscillation amplitude indicates that even at our highest pump power the mechanical amplitude remains small enough that this linear approximation remains valid.
The statistical properties of the resonator near the self-oscillation threshold can also be characterized by measuring photon correlations using an HBT set-up as shown in Fig. 1. As noted earlier, blue-detuned pumping produces anti-normally ordered phonon correlations. In this case g(2)(τ) refers to the anti-normally ordered second-order phonon correlation function, defined by . For measurements made with a red-detuned pump, as shown in Fig. 4b, g(2)(τ) refers to the normally ordered phonon correlation function, . In the case of the classical states measured here, there is no observable difference between the normally and anti-normally ordered correlation functions. As the oscillation threshold is crossed, the state of the acoustic resonator will transition from a thermal state into a displaced thermal state (DTS), and the normalized phonon intensity correlation function near τ = 0 should show a transition from bunching (g(2)(0) > 1) to Poissonian statistics (g(2)(τ) = 1 for all τ). Plots of g(2)(τ) below, at, and above threshold are shown in Fig. 4a. Below threshold, bunching is clearly visible, with g(2)(0) = 2 as expected for a purely thermal state. In Fig. 4b g(2)(0) is plotted versus nc for both blue- and red-detuned pump light. For a blue-detuned pump, a smooth decrease from g(2)(0) = 2 to g(2)(0) = 1 is observed in the threshold region, while for a red-detuned pump, the oscillator is observed to remain in a thermal state through threshold and beyond. The decay rate of the acoustic resonator, measured from both the linewidth of the NPSD and from an exponential fit to g(2)(τ) below threshold, is plotted in Fig. 4c. The decay rate as measured from the NPSD, which includes both phase and amplitude fluctuations, is seen to increase around threshold before continuing to decrease. This behaviour is commonly observed in semiconductor lasers where a coupling exists between the gain and the cavity refractive index, and a similar effect arises in optomechanical oscillators due to the optical spring effect24. The decay rate measured from g(2)(τ), on the other hand, which measures intensity fluctuations, begins to deviate from the measured linewidth in the vicinity of threshold. Thermal phonon emission dictates a strict correspondence between the second-order and first-order coherence functions4; however, above threshold where the phonon statistics are no longer purely thermal, such a deviation is possible, and in fact predicted for self-sustaining oscillators25. The Fano factor, defined as F = (Δn)2/〈n〉 = 1 + 〈n〉(g(2)(0) − 1), provides additional statistical information about the fluctuations of the oscillator, and is useful for defining a precise oscillator threshold26 as well as distinguishing between states that may have similar or identical values of g(2)(0) (for example, a coherent state versus a DTS)24. The Fano factor of our mechanical oscillator, computed from the measured g(2)(0) and the inferred values of 〈n〉, is displayed in Fig. 4d and shows the expected increase and peak in fluctuations at threshold. Above threshold, the Fano factor drops again due to saturation in the optomechanical gain, approaching a measured value consistent with that expected for a DTS (F ≈ 2nb + 1).
Although we have emphasized the analogy between the optomechanical oscillator studied here and a laser, there are unique differences which arise owing to the intrinsically nonlinear nature of the radiation pressure interaction in an optomechanical cavity. Recent theoretical studies15,24,27 indicate that a laser-driven optomechanical oscillator will enter a non-classical mechanical state with anti-bunched phonon statistics (F < 1), and under slightly more restrictive conditions, strongly negative Wigner density. Surprisingly, this is predicted to be observable even for classical parameters, that is, outside the single-photon strong-coupling regime (g0/κ < 1), and in the presence of thermal noise. Beyond phonon correlation spectroscopy of optomechanical oscillators, it is envisioned that sensitive photon counting of the filtered motional sidebands may be used in the preparation and heralding of non-Gaussian quantum states of a mechanical resonator10. For the OMC cavities of this work, with their large optomechanical coupling rate and near millisecond-long thermal decoherence time at temperatures less than 1 K (ref. 28), the phonon addition and subtraction processes of ref. 10 should be realizable with high fidelity and at rates approaching a megahertz. Whether for studies of the quantum behaviour of mesoscopic mechanical objects or in the context of proposed quantum information processing architectures using phonons and photons8, such photon counting methods are an attractive way of introducing a quantum nonlinearity into the cavity optomechanical system.
References
Hoover, E. E. & Squier, J. A. Advances in multiphoton microscopy technology. Nature Photon. 7, 93–101 (2013)
Hadfield, R. H. Single-photon detectors for optical quantum information applications. Nature Photon. 3, 696–705 (2009)
Hanbury Brown, R. & Twiss, R. Q. A test of a new type of stellar interferometer on Sirius. Nature 178, 1046–1048 (1956)
Glauber, R. J. The quantum theory of optical coherence. Phys. Rev. 130, 2529–2539 (1963)
Aspelmeyer, M., Kippenberg, T. J. & Marquardt, F. Cavity optomechanics. Rev. Mod. Phys. 86, 1391–1452 (2014)
Suh, J. et al. Mechanically detecting and avoiding the quantum fluctuations of a microwave field. Science 344, 1262–1265 (2014)
Stannigel, K., Rabl, P., Sørensen, A. S., Lukin, M. D. & Zoller, P. Optomechanical transducers for quantum-information processing. Phys. Rev. A 84, 042341 (2011)
Stannigel, K. et al. Optomechanical quantum information processing with photons and phonons. Phys. Rev. Lett. 109, 013603 (2012)
Grudinin, I. S., Lee, H., Painter, O. & Vahala, K. J. Phonon laser action in a tunable two-level system. Phys. Rev. Lett. 104, 083901 (2010)
Vanner, M. R., Aspelmeyer, M. & Kim, M. S. Quantum state orthogonalization and a toolset for quantum optomechanical phonon control. Phys. Rev. Lett. 110, 010504 (2013)
Galland, C., Sangouard, N., Piro, N., Gisin, N. & Kippenberg, T. J. Heralded single-phonon preparation, storage, and readout in cavity optomechanics. Phys. Rev. Lett. 112, 143602 (2014)
Børkje, K., Nunnenkamp, A. & Girvin, S. M. Proposal for entangling remote micromechanical oscillators via optical measurements. Phys. Rev. Lett. 107, 123601 (2011)
Lee, K. C. et al. Entangling macroscopic diamonds at room temperature. Science 334, 1253–1256 (2011)
Clerk, A. A., Devoret, M. H., Girvin, S. M., Marquardt, F. & Schoelkopf, R. J. Introduction to quantum noise, measurement, and amplification. Rev. Mod. Phys. 82, 1155–1208 (2010)
Qian, J., Clerk, A. A., Hammerer, K. & Marquardt, F. Quantum signatures of the optomechanical instability. Phys. Rev. Lett. 109, 253601 (2012)
Kronwald, A., Ludwig, M. & Marquardt, F. Full photon statistics of a light beam transmitted through an optomechanical system. Phys. Rev. A 87, 013847 (2013)
Kimble, H. J., Dagenais, M. & Mandel, L. Photon antibunching in resonance fluorescence. Phys. Rev. Lett. 39, 691–695 (1977)
Pike, R. 50th anniversary of the laser. J. Eur. Opt. Soc. Rapid Publ. 5, 10047s (2010)
Chan, J. et al. Laser cooling of a nanomechanical oscillator into its quantum ground state. Nature 478, 89–92 (2011)
Chan, J., Safavi-Naeini, A. H., Hill, J. T., Meenehan, S. & Painter, O. Optimized optomechanical crystal cavity with acoustic radiation shield. Appl. Phys. Lett. 101, 081115 (2012)
Safavi-Naeini, A. H. et al. Laser noise in cavity-optomechanical cooling and thermometry. New J. Phys. 15, 035007 (2013)
Fetter, A. L. Intensity correlations in Raman scattering. Phys. Rev. 139, A1616–A1623 (1965)
Marsili, F. et al. Detecting single infrared photons with 93% system efficiency. Nature Photon. 7, 210–214 (2013)
Rodrigues, D. A. & Armour, A. D. Amplitude noise suppression in cavity-driven oscillations of a mechanical resonator. Phys. Rev. Lett. 104, 053601 (2010)
Lax, M. Classical noise. V. Noise in self-sustained oscillators. Phys. Rev. 160, 290–307 (1967)
Rice, P. R. & Carmichael, H. J. Photon statistics of a cavity-QED laser: a comment on the laser-phase-transition analogy. Phys. Rev. A 50, 4318–4329 (1994)
Lörch, N., Qian, J., Clerk, A., Marquardt, F. & Hammerer, K. Laser theory for optomechanics: limit cycles in the quantum regime. Phys. Rev. X 4, 011015 (2014)
Meenehan, S. M. et al. Silicon optomechanical crystal resonator at millikelvin temperatures. Phys. Rev. A 90, 011803 (2014)
Acknowledgements
We thank F. Marquardt and A. G. Krause for discussions, and V. B. Verma, R. P. Miriam and S. W. Nam for their help with the single-photon detectors used in this work. This work was supported by the DARPA ORCHID and MESO programmes, the Institute for Quantum Information and Matter, an NSF Physics Frontiers Center with the support of the Gordon and Betty Moore Foundation, and the Kavli Nanoscience Institute at Caltech. Part of the research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with NASA. A.H.S.-N. acknowledges support from NSERC. S.G. was supported by a Marie Curie International Out-going Fellowship within the 7th European Community Framework Programme.
Author information
Authors and Affiliations
Contributions
O.P., S.M.M., J.D.C., S.G. and A.H.S.-N. planned the experiment. J.D.C., S.G., G.S.M., S.M.M. and A.H.S.-N. performed the device design and fabrication. F.M. and M.D.S. provided the single-photon detectors along with technical support for their installation and running. J.D.C., S.M.M., G.S.M. and O.P. performed the measurements, analysed the data and wrote the manuscript.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Supplementary Information
This file contains Supplementary Text and Data 1-8, Supplementary Figures 1-4 and additional references. (PDF 752 kb)
Rights and permissions
About this article
Cite this article
Cohen, J., Meenehan, S., MacCabe, G. et al. Phonon counting and intensity interferometry of a nanomechanical resonator. Nature 520, 522–525 (2015). https://doi.org/10.1038/nature14349
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1038/nature14349
- Springer Nature Limited
This article is cited by
-
Gigahertz optoacoustic vibration in Sub-5 nm tip-supported nano-optomechanical metasurface
Nature Communications (2023)
-
Realization of quantum ground state in an optomechanical crystal cavity
Science China Physics, Mechanics & Astronomy (2023)
-
Observation of the Hanbury Brown–Twiss effect with ultracold molecules
Nature Physics (2022)
-
Optomechanics for quantum technologies
Nature Physics (2022)
-
Far-infrared frequency mode conversion using bulk acoustic phonon modes
Applied Physics B (2022)