Abstract
Graphene-based inorganic layered materials have developed as a versatile, new class of nanomaterials and drawn huge scientific interest, owing to its thickness-dependent physical properties, exfoliated two-dimensional crystals in various technological and industrial applications. This work is the first demonstration of the fabrication of low dimensional bismuth selenide (Bi2Se3) NPs functionalized reduced graphene oxide (rGO) on the platinum electrode (Pt-E) for the ultra-sensitive and simultaneous detection of acetaminophen (ACT) and L-DOPA (LD) in the presence of ascorbic acid (AA) in various biological samples and pharmaceuticals. The constructed electrode accelerates the electron transfer reactions of LD and ACT without interfering with the electron transfer reactions of AA, which was an electroactive coexisting chemical. At pH 6.0 in 0.1 M phosphate buffer solution, Bi2Se3 NPs/rGO/Pt-E showed a sixfold and fivefold increase in cyclic voltammetry for LD and ACT signals, respectively, when compared to bare Pt-E. Under the optimal conditions, differential pulse voltammetry (DPV) demonstrated that the anodic peak currents were linearly dependent on the concentrations of LD (0.006–0.25 mM) and ACT (0.0045–0.14 mM) at anodic peak potentials of + 0.25 and + 0.52 V, respectively. With a signal to noise (S/N) ratio of 3, acceptable detection limits of 0.23 and 0.17 M were achieved for both LD and ACT, with strong intra- and inter-electrode repeatability. Overall, the fabricated nanosensor offered numerous advantages including ease to fabricate, ultra-sensitivity, good stability, and reproducibility towards the detection of LD and ACT in various bioloical samples and pharmaceuticals. The amounts of LD and ACT were also identified in commercial pharmaceuticals and synthetic urine samples to validate the applicability of the modified electrode.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Parkinson’s disease (PD) is one of the life-threatening diseases caused by an imbalance production of dopamine in the brain [1]. This can be prevented by increasing the dopamine levels with various drugs such as Levodopa (L-3,4-dihydroxyphenylalanine, LD). In humans, the LD can be biosynthetically prepared from non-essential amino acid such as tyrosine. However, the LD can autoxidize in the peripheral system and leads to various side effects, for instance, dyskinesia, vomiting, nausea, paranoia, and schizophrenia [2]. Therefore, it is essential to control its dosage by detecting the amount of LD. Keeping in mind, different analytical approaches have been proposed, including high-performance liquid chromatography [3], spectroscopy [4], flow injection analysis [5], gas chromatography [6], and capillary electrophoresis [7] for the determination of LD in pharmaceutical and biological samples.
Moreover, Acetaminophen (ACT) or Paracetamol is one of the most extensively used drugs for reducing fevers originated from bacteria or viruses, and pain caused by arthritis, backaches, headaches, and post-operation aches. Further, the patients those sensitive to aspirin can use ACT as an effective substitute and it is safe up to therapeutic doses. The ACT has an admirable safety profile due to its highest (90%) absorption capacity by the organism and then excreted through urine. However, higher doses of AC can cause nephrotoxicity and severe or sometimes fatal hepatotoxicity. Therefore, to determine ACT levels, several analytical procedures have been developed in the literature such as near-infrared transmittance spectroscopy [8], spectrofluorimetry [9], and high-performance liquid chromatography [10], spectrophotometry [11], capillary electrophoresis [12]. However, these methods are still limited due to their process complexity, non-economic, prolonged time for analysis. Whereas electrochemical techniques have superior advantages such as cost-effectiveness, sensitivity, rapidness, simplicity, and user friendly. Moreover, it is renowned that chemically modified electrodes are widely used in various fields such as clinical, environmental applications as a selective and sensitive analytical tool. Recently, researchers are focused on the design and development of sensors using the electrodes modified with nanocomposites, results in the amplification of electroanalytical signals [13]. By utilizing these features, electrodes modified with various functional materials including Au–Pd/NPSS [14], 4-MoPD/MWCNTs [15], g-C3N4-E-PEDOT [16] and Poly (L-Dopa)/MWCNTs [17] has been used for the detection of ACT and LD.
Opiates were used by Parkinson’s disease patients, drugs, and acetaminophen treating neuropathic pain such as antiepileptics and antidepressants. The pharmacokinetics of ACT will greatly change by altering the gastric emptying with other drugs. In the human body, the absorption of ACT is exponentially dependent on gastric emptying [18]. Mostly, ascorbic acid (AA) is used as dietary food or medicine. Therefore, it is a great challenge to develop an analytical method to quantify drugs without the interference of AA for better health. The literature survey reveals that very few reports existed in the literature for the electrochemical detection of LD and ACT [18]. However, these methods have certain drawbacks such as low sensitivity and AA interference.
The sheets of graphene oxide (GO) are honeycomb-shaped crystal structures made up of monolayers of carbon atoms, have recently attracted a lot of attention because of their large surface-to-volume ratio, superior chemical stability, tuneable bandgap, and good thermal, mechanical, and electronic stabilities. [19]. The unique properties of the GO nanosheets motivated to utilize in various applications such as drug delivery, protein assays, biosensors and molecular probing of living cells [20].
Moreover, various nanostructures modified with GO such as MnO2, ZnO, CuO, and Cr3O4, etc., have been recognized as promising electron mediators for the fabrication of sensitive electrochemical sensors [21]. Whereas packed advantages of bismuth have been already explored as a successful alternative electrode to substitute the noxious mercury electrode in anodic or cathodic stripping voltammetry [22]. In addition, various bismuth precursor materials were used as an electrochemical sensor, such as Bi2O3 [23], bismuth citrate [24], ammonium tetrafluorobismuthate [25], bismuth xerogel [26], bismuth phosphate[27]. It was demonstrated that the concentration of the bismuth precursors is greatly influenced the detection capabilities. Bismuth-related compounds were greatly utilized in electro-analysis of pharmaceuticals [28], hormones [29] pesticides [30], etc. As a result, innovative bismuth precursors are urgently needed in a variety of applications, including food [28], environmental [28], and clinical analysis [31]. Bismuth-based nanomaterials, on the other hand, have significant benefits over bulk bismuth precursors due to their increased surface area, chemical, and physical properties. Recently, Bismuth chalcogenides such as Bi2Te3, Bi2S3, and Bi2Se3 have gained much interest due to their 2D structures and superior performance for various applications [32]. The remarkable band gap approximately up to 0.3 eV of Bi2Se3 and its laminated structure with stacky layers (Se-Bi-Se-Bi-Se) makes it as a weak van der Waals interactions with the thickness of each layer of about 0.96 nm [32]. Overall, overcoming the limitations of the literature and leveraging the unique features of rGO and Bi to make the suggested electrochemical sensor highly selective for concomitant sensing of LD and ACT in the sight of AA is a difficult challenge.
In the present study, the Bi2Se3 NPs/rGO/Pt-E was successfully fabricated for concomitant determination of LD and ACT in the presence of AA. The present electrode system successfully overcomes the overlapping of oxidation peaks, resulted in the selective detection of targeted drugs compare to that of the unmodified electrode. Furthermore, reproducibility, ultra-sensitivity, stability, short-time response, vast linear range, and low detection limits made the Bi2Se3 NPs/rGO/Pt-E as a superior sensor.
Experimental
Chemicals and reagents
Levodopa (LD), Acetaminophen (ACT), Ascorbic acid (AA) standards of 97% analytical quality were obtained from Sigma Aldrich, Taiwan. For real sample analysis, LD and ACT pharmaceutical samples were obtained from a local pharmacy. Analytical grade bismuth (III) nitrate pentahydrate (Bi(NO3)3 0.5H2O) (98%), sodium selenite pentahydrate (Na2SeO3 0.5H2O) (99%), ethylene glycol, isopropyl alcohol, ethanol, nafion, were purchased from Sigma-Aldrich. Analytical grade disodium hydrogen orthophosphate and sodium dihydrogen orthophosphate, hydrochloric acid, sodium hydroxide, sulphuric acid were (Sigma Aldrich product) supplied by Uni-Onward Corporation (Taipei, Taiwan). Metrohm(Taipei, Taiwan) provided alumina powder with a particle size of 3 μm. Chiahlung (Taiwan) provided 99.9% of the nitrogen gas needed. Merck Millipore series water filtration provided deionized water for all solutions and samples (Merck SUPPORT, United States). For stability, all normal solutions were held at 4 °C in the Samsung refrigerator.
Instrumentation
All electrochemical measurements were carried out using Autolab/PGSTAT 204 connected to 663 VA stand and IME663 interface from Metrohm (Herisau, Switzerland) operated with a PC installed using NOVA 1.11 software. The three-electrode system consisting of the platinum electrode (Pt-E) with 3 mm diameter (working electrode), the platinum wire as a counter electrode, and Ag/AgCl as a reference electrode were used to record voltammograms at room temperature. Prior to analysis, all solutions were purged with pure (99.99%) nitrogen gas for 10 min. The pH measurements (CRISON micro pH 2000 digital pH meter) were recorded on a which was previously calibrated with a precision of 0.1 pH units using buffers of known pH. The as-prepared Bi2Se3 NPs and Bi2Se3 NPs/rGO were well characterized as follows. Powder X-ray diffraction (XRD) using a Rigaku D/MAX-2500 X-ray diffractometer with Cu Kα radiation (= 1.5406 A°) at 40 kV and 20 mA was used to examine the crystal structures of the samples. The UV–Vis-NIR spectra for rGO, Bi2Se3 NPs, and Bi2Se3 NPs/GO were recorded using a JASCO V-570 spectrometer in the wavelength range of 350–1200 nm, with a resolution of 1 nm. The morphologies and elemental composition of the Bi2Se3 NPs and Bi2Se3 NPs/rGO were analyzed by a JEOL JEM-2100 TEM coupled with an EDXA analyzer as well as a JEOL, JSM-7000F SEM. A VG-ESCALAB 220 i-XL system was used for the XPS experiments. Bi2Se3 NPs/rGO samples were mounted on a sample holder and cleaned and measured in the same manner. The imaging capabilities of the system were used to regulate the probe zone on the surface. The chamber’s base pressure was around 6 × 10–8 Pa, and the sample was not contaminated during the measurements.
Synthesis of rGO, Bi2Se3 NPs and Bi2Se3 NPs/rGO nanocomposite
Reduced graphene oxide was synthesized using the pristine graphite flakes as a starting material following by the modified Hummers process [33]. The Bi2Se3 NPs was synthesized by the reported procedure [34] with some modifications: 1 mM of Bi(NO3)3 and 1.5 mM of Na2SeO3 were stirred for 1 h in 35 mL of ethylene glycol after dissolving, the reaction mixture temperature was raised to 260 °C for 5 h and then cool down to room temperature. Isopropyl alcohol was added to the reaction mixture to precipitate the Bi2Se3 NPs, followed by acetone washings to remove unreacted components, ethylene glycol, and oven drying for 6 h at 50 °C.
Preparation of Bi2Se3 NPs/rGO nanocomposite
Bi2Se3 NPs/rGO hybrid dispersion was prepared as follows: Typically, Bi2Se3 NPs (0.5 mg mL−1) and 0.5 mg mL−1 of rGO were added in 1 mL of ethanol: water (2:3) mixture. Finally, to the mixture, 100 µL of Nafion was added and sonicated for 1 h in an Elmasonic S40, 140 W sonication bath. Nafion acts as a binder to the electrode surface. Before modification of Pt-E, Bi2Se3 NPs/rGO nanocomposite was agitated for 4 h.
Preparation of working electrodes
A bare Pt-E was manually polished to a mirror-like surface with 3 µm alumina slurry followed by the rinsing with deionized distilled water. Thenafter, 3–5 drops of concentrated nitric acid in a deionized distilled water was added to perform the electrochemical cleaning at a potential range of − 0.4–1.0 V for 30 cycles to remove physisorbed or chemisorbed materials from the surface of the electrode. After that, the Pt-E was coated with 6 µL of Bi2Se3/rGO by gently dropping it onto the surface of the electrode and widely distributed with a tip followed by the drying in a 50 °C oven for 10 min to obtaine a Bi2Se3/rGO/Pt-E.
Preparation of stock solutions
In a 5.0 mL volumetric flask, standard solutions of AA, LD and ACT were prepared using appropriate quantities and further diluted with deionized distilled water. Similarly, 100 mL of 0.1 M phosphate buffer was prepared using dihydrogen orthophosphate and disodium hydrogen orthophosphate in deionised distilled water. The optimum pH of the solution was set to 6.0 by adding the appropriate amount of NaOH/HCl and stored at 4 °C. These solutions were cleaned before voltammetric measurements with a disposal syringe having a 25 mm diameter, 0.45 mm pore size cellulose filter.
Preparation of ACT and LD pharmaceuticals and synthetic urine samples
The ACT pharmaceuticals were prepared by crushing the three Ancogen tablets (250 mg mL−1, Hua Shin Chemical Pharmaceutical works CO., LT, Taiwan) and three SOMA tablets (250 mg mL−1, Standard Chem & Pharm CO., LTD, Taiwan) to a fine powder. An equivalent one tablet weight of the powder was dissolved in 25 mL of 0.1 M PBS at pH 6.0, ultrasonicated for 5 min, and diluted to 100 mL with PBS. The quantification of ACT and LD were performed with DPV using a regression equation. Similarly, LD in 1 mL of dopamine injection (40 mg mL−1, Taiwan Biotech CO., LTD) was prepared by diluting 50 mL of 0.1 M PBS at pH 6.0.
The synthetic urine sample was prepared according to the literature [35]. 0.40 g KCl, 0.28 g CaCl2·2H2O, 0.73 g NaCl, 0.35 g KH2PO4, 0.56 g Na2SO4, 25 g NH4Cl, and 6.25 g urea have been introduced to a 250 mL of volumetric flask with deionized distilled water. As synthetic urine samples were doped with three different concentrations of LD: 10, 15, and 25 µM and ACT: 10, 20, and 30 µM, respectively, and aliquots of each sample were diluted with supporting electrolyte solution and the final solutions were analyzed.
Procedure for the electrochemical measurement of LD and ACT
A 10 mL of 0.1 M PBS was added to an electrochemical cell equipped with bare Pt-E or Bi2Se3 NPs/rGO/Pt-E as a working electrode. After achieving low background current by several cyclic sweeps, an aliquot (analyte solution) was added and a pre-concentrated potential was applied with a stirring (400 rpm) of solution. The stirring was stopped at the end of the pre-concentration time and allowed for 5 s equilibration period to become inert. The DPV was recorded using the bare or Bi2Se3 NPs/rGO/Pt-E by positive scanning mode at a rate of 0.1 V/s, for each measurement, the working electrode was cleaned with deionized distilled water.
Results and discussion
Characterization of Bi2Se3 NPs/rGO nanocomposite
Bi2Se3 NPs were synthesized by high-temperature reaction and further fabricated on graphene oxide through sonication process and characterized using different spectroscopic techniques. With scanning electron microscopy (SEM) and transmission electron microscopy (TEM), the morphologies and nanostructures of as-prepared Bi2Se3 NPs and Bi2Se3 NPs/rGO were investigated. The layer structure of Bi2Se3 NPs is depicted in SEM pictures (Fig. 1A, B), with some showing truncated trigonal morphology with an average size of 0.8–0.9 m. Some are generated in the intermediate stage and show truncated trigonal morphology with an average size of 0.8–0.9 m. Furthermore, as shown in Fig. 1B, the Bi2Se3 NPs were well penetrated by thin layers of rGO. In the image, the curves and outlines of overlap between two nanoplates could be seen. Low magnification bright-field TEM was used to corroborate the hexagonal morphology of the Bi2Se3 NPs, as shown in Fig. 1C.
The selected area electron diffraction (SAED) pattern (Fig. 1D) has a sixfold symmetry with a [0 0 1] zone axis pattern, which matches the prior study [36]. Figure 1E, F depict a thin layer of rGO nanosheets and hexagonal Bi2Se3 NPs wrapped in rGO layers, respectively. The chemical composition of Bi2Se3 NPs was determined by energy dispersive X-ray analysis (EDXA). The strong characteristic signals of Bi2Se3 NPs for Bi and Se at 1.9 kev, 2.52 keV and 1.47 keV respectively, as shown in Fig. 2A. The obtained results were in comparison with the literature [37, 38]. However, the weak signals of carbon, oxygen and copper at 0.25, 0.5, 1.0, 5.3 and 8 keV were observed due to the usage of copper grid during the anslysis of transmission electron microscope. In the case of synthesis of AgNPs and AuNPs by the Singh and co-workers, similar minor peaks were also observed in the spectra of EDXA [39].
Furthermore, the synthesized Bi2Se3 NPs was also characterized by elemental mapping, in which the weight percentage (wt %) and of bismuth (Bi M) and selenium (Se L) were found to be 62.34% and 37.66% and atomic percentage (at %) of Bi M and Se L were 38.47% and 61.53%, respectively, as shown in Table 1. These results demonstrated that the at % of Bi M to Se L was found to be approximately 2:3, confirming the product to be Bi2Se3 [38].
The powder XRD patterns of the Bi2Se3 NPs, rGO, and Bi2Se3 NPs/rGO samples also confirmed phase composition and structural characteristics, as shown in Fig. 2B–D. Figure 2B shows the observed typical diffraction peaks of carbon in rGO (001) at 2θ = 10o. XRD pattern for the orthorhombic structure of Bi2Se3 was illustrated in Fig. 2C. The obtained XRD diffraction peaks are consistent with the reported values (JCPDS Card No.33-0214) as per literature [40,41,42]. According to the previous study, (0 1 5), (1 0 1 0), (1 1 0) facets are the three strongest diffraction peaks at 2θ = 41.3°, 44.5°, 48.7° for Bi2Se3 NPs with reference to our previously reported paper [34]. Whereas a typical diffraction peak of rGO at 2θ = 18.4° has been noted in the XRD pattern of Bi2Se3 NPs/rGO nanocomposite as illustrated in Fig. 2D.
This indicates the proper matching of lattices between the counterparts which is favorable for the stability of nanocomposite. The UV–visible absorption spectrum of suspended rGO nanosheets is shown in Fig. 2E. The major absorption peak at about 230 nm is due to the π → π* transitions of aromatic C–C bond, and a shoulder at about 300 nm can be assigned to the π → π* transitions of C=O bonds which confirms the existence of oxygen functional groups in rGO nanosheets [43].
UV–vis-NIR spectra of graphene oxide have strongly dropped NIR absorbance however, Bi2Se3 NPs and Bi2Se3 NPs/rGO having broad NIR absorbance due to the strong absorption of light. XPS was used to investigate the surface chemical composition of Bi2Se3 NPs/rGO nanocomposite. The high-resolution spectra were recorded at a narrow energy range as shown in Fig. 2F. The major elements present in the composite Bi, Se, C, and O were determined at 157.8–163 eV, 53.7–54.3 eV, 284–289 eV, and 532 eV, respectively.
Figure 3A, B shows the C1s and O1s XPS spectra of rGO, respectively. The C–C and C–H binding energies were assigned at 284.5–285 eV, and chemical shifts of C–OH, C=O, and O=C–OH functional groups are + 1.5, + 2.5 and + 3.7 eV, respectively [44]. The high-intensity peak at 532 eV represents the presence of a high amount of oxygen in the form of carboxylic, alcoholic groups in the composite (Fig. 3A). The high-resolution spectra of Bi4f (Fig. 3C) and Se3d (Fig. 3D) indicating that Bi4f peak exhibited much higher intensity than that of Se3d peak. Furthermore, Bi4f spectra revealed peaks at 158.2 and 163.8 eV for Bi4f7/2 and Bi4f5/2, respectively, which are consistent with literature [45]. Whereas, Se3d spectra showed a peak at 53.7 eV which corresponds to the bonding energy of the Se3d transition. According to the peak areas of Bi4f and Se3d, the atomic ratio of Bi/Se was 40.5:59.5, indicating that Bi2Se3 NPs were formed with a high density of selenium vacancies.
The atomic force microscopy (AFM) analyses were performed to evaluate the surface morphology of the synthesized Bi2Se3 NPs/rGO nanocomposite. The AFM amplitude images in Fig. 4 demonstrates a hexagonal nanoplate with rGO sheets. The height profile indicates that the thickness increased from the edge to the center and the nanocomposite was in the size of 41 nm.
Optimization of solution pH and accumulation time
The electrochemical reaction of the developed Pt-E to LD and ACT was investigated in various electrolyte solutions, including acetate buffer solution, Britton–Robinson buffer solution, and PBS at pH 6.0. The electrode had the highest sensitivity to LD and ACT of all the PBS solutions tested. The impact of pH on anodic peak potentials and anodic peak currents was also investigated. The DPV analyses were conducted for individual solutions of LD and ACT in the pH range of 4.0–8.0. As shown in Fig. 5A, B, the anodic peak currents (Ipa) varied with pH. Both LD and ACT oxidation peak currents increased when the pH climbed from 4.0 to 6.0. However, as the pH rises, the peak current decreases, indicating sluggish electron transfer kinetics. PBS with a pH of 6.0 was utilized as a supporting electrolyte for the simultaneous electrochemical detection of LD and ACT in the mixture based on the results.
Furthermore, the DPV analyses revealed that the peak potentials varied linearly with pH (Fig. 5A, B), as stated in the equations below:
The findings showed that as pH increased, the oxidation peak potentials of LD and ACT changed towards lower potentials, indicating that protons were transferred throughout the electrochemical process of LD and ACT. The slopes of oxidation peak potential (Ep) vs. pH at 25 °C were 62 mV/pH and 57 mV/pH for LD and ACT, respectively. These results demonstrated that the oxidation process of LD and ACT at Bi2Se3 NPs/rGO/Pt-E required a same number of protons and electrons, which was calculated as 2. Figure 5C, D represents the cyclic voltammograms of 0.5 mM LD and ACT recorded at Pt-E modified with rGO, Bi2Se3 NPs and Bi2Se3 NPs/rGO. The results clearly demonstrated that the electrochemical signals obtained with Bi2Se3 NPs/rGO were much higher than that of rGO and Bi2Se3 NPs in both cases.
Figure 6 represents the electrode mechanism of LD and ACT at Bi2Se3 NPs/rGO/Pt-E. The sensitivity of the electrode towards analytes can be enhanced by accumulation studies that are simple and effective. Accumulation time and potential studies were carried out with 0.5 mM ACT and LD at Bi2Se3 NPs/rGO/Pt-E. Figure 7A depicts the effect of accumulation potential on ACT and LD oxidation peak currents. In the potential range of − 0.6–0.8 V, the variation in the anodic peak currents of LD and ACT with the accumulating potential was investigated. As shown in Fig. 7B, the anodic peak currents increased as accumulation potential decreased from 0.8 to − 0.5 V. However, the peak current was unchanged with higher negative potentials. Therefore, − 0.2 V was chosen as accumulation potential for further studies. The influence of the accumulation period on the anodic peak currents of LD and ACT was investigated at a fixed accumulation potential of − 0.2 V, as shown in Fig. 7B. For achieving fair detection limits in voltammetry, accumulation time is an important factor. As the accumulation time increases from 10 to 150 s, the peak current also increased. The extended accumulation time would give a better platform for the LD and ACT to complete their oxidation reactions, leading in a greater peak current. However, when the accumulation time rose, the peak current remained unchanged due to the oxidized LD and ACT reaching saturation of modified Pt-E. As a result, a 100 s accumulation time was chosen for further research.
Electrochemical characterization of Bi2Se3 NPs/rGO/Pt-E
The microscopic areas of the Bi2Se3 NPs/rGO/Pt-E were electrochemically measured using 1 M K3Fe(CN)6 as a probe solution with cyclic voltammetry (CV). One-electron transfer reaction (n = 1) was seen in the [Fe(CN)6]3−, which is one of the most investigated redox coupling reactions in the field of electrochemistry. The cathodic and anodic peak currents of the redox probe increase linearly with the increase in the scan rate increase from 10 to 210 mV/s. However, the cathodic and anodic peak potentials shifted to both negative and positive sides. The Randles–Sevcik equation was used to determine the microscopic area of bare and modified Pt-Es [46]:
The peak current, electrode surface area, K3Fe(CN)6 concentration, number of electrons transferred, diffusion coefficient, and scan rate are represented by IP, A, C0, n, DR, and v, respectively. From the slope of the ipc–v1/2 graph, the DR was calculated as 6.7 × 10−6 cm2 s−1. The surface area of Bi2Se3 NPs/rGO/Pt-E was calculated as 0.752 cm−2, which is six times higher than that of bare Pt-E.
Furthermore, the current potential responses were examined to assess the electrochemical performance of the Bi2Se3 NPs/rGO/Pt-E sensor for LD and ACT sensing in pharmaceuticals and biological samples. The microscopic areas of the electrodes are influenced by the peak responses of LD and ACT. In a phosphate buffer of pH 6.0 (10 mL) and scan rate of 10 mV/s, a comparison investigation was conducted on peak currents (ipa) utilizing CV. Peak currents were proportional to the amount of electroactive surface area. The electrochemical responses of LD and ACT at + 0.25 and + 0.52 V (vs Ag/AgCl) representing curves a,b and c for bare Pt-E, rGO/Pt-E and Bi2Se3 NPs/rGO/Pt-E, respectively, as illustrated in Fig. 5C, D. Both compounds showed broad and weak intensity waves at + 0.25 and + 0.52 V due to the sluggish electron transport kinetics of the oxidation process at bare Pt-E. Modification of electrodes with rGO enhances the voltammetric signals (intensity anodic peaks) of LD and ACT at the same potentials.
The catalytic mechanism behind the detection of LD and ACT depends on the n-type semiconducting behaviour of Bi2Se3 NPs due to the charges on the selenium vacancies leading to the lattice defects and resulted as electron donors. The covently bonded monolayers of five sets are in the order of Se-Bi-Se-Bi-Se, in which Se is assembled on either side, resulted as a bidentate ligand. During the electrochemical process, one electron trapping step occurs on the surface of Bi2Se3 at 0.41 V, converting Bi2Se3 NPs to Bi2Se3·− species at − 0.60 V, which is stimulated upon oxidation. When LD and ACT interact with radical anion (Bi2Se3·−), reduction occurs resulting in the conversion of Bi2Se3·− to Bi2Se3, followed by the oxidation of analytes. As a result, Bi2Se3 acts as an efficient electrocatalyst for the oxidation of LD and ACT, with the degree of oxidation proportional to the current generated. Considering a previous study by Savariraj et al., 2019 where Bi2Se3 was used as an electrocatalyst to fabricate the non-enzymatic glucose sensor, Bi2Se3 has been used as a mediator to enhance the electron transfer between the electrode and analytes in the electrochemical detection of LD and ACT with Bi2Se3. [47].
For comparison, a study was performed on the LD and ACT response with Bi2Se3 NPs coated Pt-E, however, it is difficult to coated Bi2Se3 NPs alone due to low density and less adhesion property. The high loading of Bi2Se3 NPs and greater concentration of nafion on the surface of Pt-E shows no significant changes in the results as illustrated in Fig. 5C, D, where the peak currents achieved for both the compounds with rGO and pure Bi2Se3 NPs are almost in the same range. However, the electrochemical signaling of LD and ACT was greatly improved at Pt-E modified with rGO and Bi2Se3 NPs. The bar graph (inset Fig. 5C, D) exhibited relative current responses of three electrodes studied, demonstrating that the peak currents with Bi2Se3 NPs/rGO/Pt-E at 59.2 µA (LD) and 46.5 µA (ACT) were remarkably greater than that of currents obtained with bare Pt-E, rGO/Pt-E and Bi2Se3/Pt-E at 3.1 µA (LD), 5.2 µA (ACT) and 6.2 µA (LD), 10.4 µA (ACT) and 7.5 µA (LD) and 8.3 µA (ACT), respectively.
Using Bi2Se3 NPs/rGO/Pt-E, cyclic voltammetry was used to investigate simultaneous electrochemical detection of LD and ACT in the presence of AA, as shown in Fig. 8A. A well-defined anodic peaks were observed at 0.05 V for 0.2 mM AA (curve a), at 0.05 V for 0.2 mM AA + 0.25 V for 0.1 mM LD (curve b), at 0.05 V for 0.2 mM AA + 0.25 V for 0.1 mM LD + 0.57 V for 0.1 mM ACT (curve c). The AA, LD and ACT exhibited distinct anodic peaks at 0.05, 0.25 and 0.57 V with a peak to peak separation of 0.20 V (between AA and LD), 0.52 V (between AA and ACT), 0.32 (between LD and ACT) as shown in the inset showing the response of Bi2Se3 NPs/rGO/Pt-E in 0.1 M PBS. The anodic peaks resulted from Bi2Se3 NPs/rGO/Pt-E has greater separation efficiency for the concurrent sensing of LD and ACT in the sight of AA and further in any mixture. The efficient electrocatalytic effect of Bi2Se3 NPs/rGO/Pt-E was monitored by the oxidation of LD and ACT with sharp peaks, good selectivity, large peak separations and enhanced current responses, resulting in the amplification of electrochemical signaling of LD and ACT. The enhancement in both LD and ACT peak currents is due to the greater area of the layer on the surface of modified Pt-E and improvement in the electron transfer process.
To obtain the kinetic parameters, the effect of scan rates on the peak currents were studied with 0.2, 0.1 mM and 0.1 mM solutions of AA, LD and ACT on Bi2Se3 NPs/rGO/Pt-E using CV mode. Figure 8B shows the anodic peak currents for three compounds were linearly increases with an increase in the scan rate from 10 to 170 mV/s, indicating the oxidation process was adsorption controlled. Consequently, AA, LD, and ACT are first adsorbed and accumulated on the electrode surface and then followed by an electrochemical reduction reaction. The adsorbed quantities of analytes (AA, LD, and ACT) on the Pt-E surface was calculated using the following equation:
The Faraday’s constant is F (C mol−1), Q(C) is the quantity of charge spent during the electro-oxidation reaction, and v (Vs−1) is the scan rate. The area of the electrode is A (cm2), and the surface concentration of the electroactive AA, LD, and ACT is I−T (mol cm−2).
Integration of the peak area of modified Pt-Es, resulted in a straight line with a slope of 0.11 and 0.50 and 1.1 within the same scan range for AA, LD and ACT, respectively. From Eq. (4) the values of n and I−T were obtained and the results were 0.32, 1.6 and 3.1 × 10–6, respectively. At an optimum scan rate of 50 mV/s, Bi2Se3 NPs/rGO/Pt-E showed 24.8, 79.8 and 108 µA of the peak current, which was nearly tenfold compared to peak current measured at bare Pt-E (2.8, 8.4, and 11.7 µA) for AA, LD and ACT indicate the fair catalytic activity of nanocomposite materials.
The effect of scan rate on the peak potentials was studied with the same concentration of AA, LD and ACT, and the anodic peak potential shifted to a more positive side with an increase in the scan rate. The linear regression equations were constructed between the peak potentials and the scan rates (v) at the modified Pt-Es were shown in Fig. 8B.
From the regression equation, the electrochemical parameters, electron transfer co-efficient (α) 0.37 and 0.48 for both LD and ACT, and the electrode reaction standard rate constant (ks) 1.73 and 2.17 s−1 were calculated using Laviron’s equation at the modified electrode.
Quantification studies of LD and ACT with DPV
The DPV responses for various concentrations of LD and ACT at the modified electrode in 0.1 M phosphate buffer (pH 6.0) were measured individually under the best experimental conditions (pH 6.0, accumulation time: 100 s, accumulation potential: − 0.25 mV, pulse amplitude: 50 mV, voltage step: 2 mV, voltage step time: 0.4 s). The results revealed a linear relationship between the peak currents recorded and LD concentrations ranging from 0.006 to 0.25 mM, as shown in Fig. 8C. The peak current at a potential of + 0.25 V (vs Ag/AgCl) increases sensitively with an increase in the concentration of LD. The linear regression equation for LD was obtained as Ipa(µA) = 404.65C + 45.205 (R2 = 0.9866) with a limit of detection (LOD) and limit of quantification (LOQ) of 0.23 and 0.71 µM, respectively, at the signal to noise ratio of 3. Similarly, a linear relationship between the peak currents and concentration ranging from 0.0045 to 0.14 mM of ACT was observed as shown in Fig. 8D. The peak current at a potential of + 0.52 V (vs Ag/AgCl) increases gradually with an increase in the concentration of ACT. The calculated linear regression equation was noted as Ipa(µA) = 434.41C + 41.277 (R2 = 0.9879) with a LOD and LOQ values of 0.17 µM and 0.53 µM respectively, at signal to noise ratio of 3. The split in the LD and ACT calibration curves is most likely due to the creation of a sub-monolayer at low concentrations and a monolayer at high concentrations in the calibration plot.
The DPV studies were used to detect LD, ACT in the sight of AA concurrently. Three well-defined peaks were seen in Fig. 9A, showing that the Bi2Se3 NPs/rGO/Pt-E electrochemical sensor was an acceptable electrochemical sensor for concurrent sensing of two analytes. Peak currents for LD, ACT, and AA rose as concentration increased. The calibration curves were linear in some ranges when the peak potentials were constant (Fig. 9B). These findings suggest that Bi2Se3 NPs/rGO/Pt-E had adequate linear ranges and detection limits for simultaneously detecting LD and ACT in the presence of AA. The linear regression equations achieved for both LD and ACT are shown in (Fig. 9B).
The analytical performance of the proposed electrode was summarized and compared with literature reports as tabulated in Table 2. The fabricated electrochemical sensor, Bi2Se3 NPs/rGO/Pt-E exhibited lower linear range and detection limits compared to the reported electrochemical sensors. Therefore, it could open a new venue for the simultaneous detection of LD and ACT in the presence of AA with ultra-sensitivity and high selectivity.
Validation of Bi2Se3 NPs/rGO/Pt-E
The fabricated electrochemical sensor was verified by measuring the parameters such as robustness, precision, accuracy, recovery, and selectivity. Five replicate measurements on 0.1 mM LD and ACT assay were done on the first day (intra-day) and after 5 days (inter-day) to determine the accuracy. The standard addition method was used to examine recovery and results were showed in Table 3. To test the sensor’s stability, it was submerged in PBS (pH 6.0) containing LD and ACT for 5 days and the voltammograms were recorded. The results were compared with the voltammograms of the same sensor obtained after every 5 days. The obtained data revealed that the peak currents decreased slightly, indicating that the developed electrochemical sensor possessed long-term stability. In the presence of excipients including uric acid, caffeine, calcium (II), magnesium (II), tryptophan, valine, tyrosine, glucose, atenolol, phenylalanine, and Amlodipine, the capacity of the optimized technique to detect LD and ACT selectively was investigated. The degree of substantial interference with LD and ACT was evaluated using the current ratio method. The peak currents obtained from LD and ACT were measured alone (IR) in 0.5 mM of excipient substance (IR+S). The current ratios (IR+S/IR) of LD and ACT were in the range of 0.92 ± 0.05 to 1.01 ± 0.03 for above mentioned co-existing interferents, respectively (Fig. 9C). The current ratios were unchanged in the presence of interferents, indicating that the fabricated electrochemical sensor possessed an excellent selectivity towards the analytes. Variations in some of the key factors, such as preconcentration, time, pH, and potential, were used to assess the robustness. The obtained findings demonstrated the manufactured electrochemical sensor's dependability in the analysis of LD and ACT. Within the analyzed range of operational parameter adjustments, the mean % recoveries of five replicate measurements were not significantly altered, indicating that the Bi2Se3 NPs/rGO/Pt-E is a reliable electrochemical sensor.
Analytical applications
By analyzing pharmaceuticals and synthetic urine samples, the analytical applications of the constructed sensor (Bi2Se3 NPs/rGO/Pt-E) were investigated to detect LD and ACT. The standard addition method was used to analyze the real and urine samples at Bi2Se3 NPs/rGO/Pt-E to avoid the matrix effect. The voltammetric responses of urine and actual samples spiked with known concentrations of LD and ACT were recorded after they were diluted [4 times with 0.1 M PBS (pH 6.0) without any pretreatment]. The results showed that the Bi2Se3 NPs/rGO/Pt-E sensor is reliable, it could be successfully applied to the detection of LD and ACT in real pharmaceutical and urine samples (Table 4 and Fig. 9D).
Conclusions
The novel fabricated electrochemical sensor, Bi2Se3 NPs/rGO/Pt-E has exceptional properties such as excellent adsorptive properties, electrocatalytic properties, and high specific surface area. To our knowledge, this is the first time that Bi2Se3 NPs/rGO/Pt-E were used to selectively recognize and sensitively determine LD and ACT in the presence of AA. For the simultaneous detection of LD and ACT, the electrochemical characteristics of all three electrodes, bare Pt-E, rGO/Pt-E, and Bi2Se3 NPs/rGO/Pt-E, have been studied. Interestingly, it was noticed that Bi2Se3 NPs/rGO/Pt-E exhibited high selectivity and ultra-sensitivity towards LD and ACT. In comparison to previous methods published in the literature, the suggested method is very reliable and sensitive in reaching ultra-low detection limits, very good reproducibility, wide linear dynamic range, and repeatability. The proposed strategy is expected to be extremely beneficial to both the pharmaceutical industries and the clinical sector.
References
Castro Caldas, A., Teodoro, T., Ferreira, J.J.: The launch of opicapone for Parkinson’s disease: negatives versus positives. Expert Opin. Drug Saf. 17, 331–337 (2018)
Movlaee, K., Beitollahi, H., Ganjali, M.R., Norouzi, P.: Electrochemical platform for simultaneous determination of levodopa, acetaminophen and tyrosine using a graphene and ferrocene modified carbon paste electrode. Microchim. Acta. 184, 3281–3289 (2017)
César, Id.C., Byrro, R.M.D., de Santana e Silva Cardoso, F.F., Mundim, I.M., de Souza Teixeira, L., Pontes da Silva, E., Gomes, S.A., Bonfim, R.R., Pianetti, G.A.: Simultaneous quantitation of levodopa and 3-O-methyldopa in human plasma by HPLC–ESI-MS/MS: Application for a pharmacokinetic study with a levodopa/benserazide formulation. J. Pharm. Biomed. Anal. 56, 1094–1100 (2011)
Yue, H.Y., Zhang, H., Huang, S., Lin, X.Y., Gao, X., Chang, J., Yao, L.H., Jun Guo, Er.: Synthesis of ZnO nanowire arrays/3D graphene foam and application for determination of levodopa in the presence of uric acid. Biosens Bioelectron. 89, 592–597 (2017)
Pistonesi, M., Centurión, M.E., Band, B.S.F., Damiani, P.C., Olivieri, A.C.: Simultaneous determination of levodopa and benserazide by stopped-flow injection analysis and three-way multivariate calibration of kinetic-spectrophotometric data. J. Pharm. Biomed. Anal. 36, 541–547 (2014)
Hansson, C., Agrup, G., Rorsman, H., Rosengren, A.M., Rosengren, E., Edholm, L.E.: Analysis of cysteinyldopas, dopa, dopamine, noradrenaline and adrenaline in serum and urine using high-performance liquid chromatography and electrochemical detection. J. Chromatogr. B Biomed. Appl. 162, 7–22 (1979)
He, W.-W., Zhou, X.-W., Lu, J.-Q.: Simultaneous determination of benserazide and levodopa by capillary electrophoresis–chemiluminescence using an improved interface. J. Chromatogr. A. 1131, 289–292 (2006)
Soh, C.S., Raveendran, P.: Multi-resolution analysis of near infrared spectroscopic data for calibration and prediction of active substances in phosphate buffer solution, pp. 415–418. Springer, Berlin Heidelberg (2007)
Vilchez, J., Blanc, R., Avidad, R., Navalón, A.: Spectrofluorimetric determination of paracetamol in pharmaceuticals and biological fluids. J. Pharm. Biomed. Anal. 13, 1119–1125 (1995)
Nebot, C., Gibb, S.W., Boyd, K.G.: Quantification of human pharmaceuticals in water samples by high performance liquid chromatography–tandem mass spectrometry. Anal. Chim. Acta. 598, 87–94 (2007)
Săndulescu, R., Mirel, S., Oprean, R.: The development of spectrophotometric and electroanalytical methods for ascorbic acid and acetaminophen and their applications in the analysis of effervescent dosage forms. J. Pharm. Biomed. Anal. 23, 77–87 (2000)
Perez-Ruiz, T., Martinez-Lozano, C., Tomas, V., Galera, R.: Migration behaviour and separation of acetaminophen and p-aminophenol in capillary zone electrophoresis: analysis of drugs based on acetaminophen. J. Pharm. Biomed. Anal. 38, 87–93 (2005)
Kunene, K., Weber, M., Sabela, M., Voiry, D., Kanchi, S., Bisetty, K., Mikhael, B.: Highly-efficient electrochemical label-free immunosensor for the detection of ochratoxin A in coffee samples. Sens. Actuators B Chem. 305, 127438 (2020)
Rezaei, B., Shams-Ghahfarokhi, L., Havakeshian, E., Ensafi, A.A.: An electrochemical biosensor based on nanoporous stainless steel modified by gold and palladium nanoparticles for simultaneous determination of levodopa and uric acid. Talanta 158, 42–50 (2016)
Fouladgar, M., Karimi-Maleh, H., Gupta, V.K.: Highly sensitive voltammetric sensor based on NiO nanoparticle room temperature ionic liquid modified carbon paste electrode for levodopa analysis. J. Mol. Liq. 208, 78–83 (2015)
Xu, Y., Lei, W., Su, J., Hu, J., Yu, X., Zhou, T., Yang, Y., Mandler, D., Hao, Q.: A high-performance electrochemical sensor based on g-C3N4-E-PEDOT for the determination of acetaminophen. Electrochim. Acta. 259, 994–1003 (2018)
Yang, C., Zhu, S., Ma, J., Song, J., Ran, P., Fu, Y.: Highly sensitive electrochemical sensing platform for the detection of L-dopa based on electropolymerizing glutathione disulfide and multi-walled carbon nanotube-modified electrodes. S. Afr. J. Chem. 71, 182–187 (2018)
Babaei, A., Sohrabi, M.: Selective simultaneous determination of levodopa and acetaminophen in the presence of ascorbic acid using a novel TiO2 hollow sphere/multi-walled carbon nanotube/poly-aspartic acid composite modified carbon paste electrode. Anal. Methods. 8, 1135–1144 (2016)
Zhang, Z., Fu, X., Li, K., Liu, R., Peng, D., He, L., Wang, M., Zhang, H., Zhou, L.: One-step fabrication of electrochemical biosensor based on DNA-modified three-dimensional reduced graphene oxide and chitosan nanocomposite for highly sensitive detection of Hg(II). Sens. Actuators B Chem. 225, 453–462 (2016)
Venkatesh, K., Rajakumaran, R., Chen, S.-M., Karuppiah, C., Yang, C.-C., Ramaraj, S.K., Ali, M.A., Al-Hemaid, F.M.A., El-Shikh, M.S., Almunqedhi, B.M.A.: A novel hybrid construction of MnMoO4 nanorods anchored graphene nanosheets; an efficient electrocatalyst for the picomolar detection of ecological pollutant ornidazole in water and urine samples. Chemosphere 273, 129665 (2021)
Zhu, C., Yang, G., Li, H., Du, D., Lin, Y.: Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal. Chem. 87, 230–249 (2015)
Serrano, N., Alberich, A., Díaz-Cruz, J., Ariño, C., Esteban, M.: Coating methods, modifiers and applications of bismuth screen-printed electrodes. Trends Anal. Chem. 46, 15–29 (2013)
Wang, J., Lu, J., Hocevar, S.B., Farias, P.A.M., Ogorevc, B.: Bismuth-coated carbon electrodes for anodic stripping voltammetry. Anal. Chem. 72, 3218–3222 (2000)
Lezi, N., Economou, A., Dimovasilis, P.A., Trikalitis, P.N., Prodromidis, M.I.: Disposable screen-printed sensors modified with bismuth precursor compounds for the rapid voltammetric screening of trace Pb(II) and Cd(II). Anal. Chim. Acta. 728, 1–8 (2012)
Sopha, H., Baldrianová, L., Tesařová, E., Grincienė, G., Weidlich, T., Švancara, I., Hočevar, B.: A new type of bismuth electrode for electrochemical stripping analysis based on the ammonium tetrafluorobismuthate bulk-modified carbon paste. Electroanalysis 22, 1489–1493 (2010)
Dimovasilis, P.A., Prodromidis, M.I.: Bismuth-dispersed xerogel-based composite films for trace Pb(II) and Cd(II) voltammetric determination. Anal. Chim. Acta. 769, 49–55 (2013)
María-Hormigos, R., Gismera, M.J., Procopio, J.R., Sevilla, M.T.: Disposable screen-printed electrode modified with bismuth–PSS composites as high sensitive sensor for cadmium and lead determination. J. Electroanal. Chem. 767, 114–122 (2016)
Riman, D., Avgeropoulos, A., Hrbac, J., Prodromidis, M.I.: Sparked-bismuth oxide screen-printed electrodes for the determination of riboflavin in the sub-nanomolar range in non-deoxygenated solutions. Electrochim. Acta. 165, 410–415 (2015)
de Lima, C.A., Spinelli, A.: Electrochemical behavior of progesterone at an ex situ bismuth film electrode. Electrochim. Acta. 107, 542–548 (2013)
de Figueiredo-Filho, L.C.S., dos Santos, V.B., Janegitz, B.C., Guerreiro, T.B., Fatibello-Filho, O., Faria, R.C., Humberto, L., Junior, M.: Differential pulse voltammetric determination of paraquat using a bismuth-film electrode. Electroanalysis 22, 1260–1266 (2010)
Sopha, H., Hocevar, S.B., Pihlar, B., Ogorevc, B.: Bismuth film electrode for stripping voltammetric measurement of sildenafil citrate. Electrochim. Acta. 60, 274–277 (2012)
Tseliou, F., Avgeropoulos, A., Falaras, P., Prodromidis, M.I.: Low dimensional Bi2Te3-graphene oxide hybrid film-modified electrodes for ultra-sensitive stripping voltammetric detection of Pb(II) and Cd(II). Electrochim. Acta. 231, 230–237 (2017)
Hummers, W.S., Offeman, R.E.: Preparation of graphitic oxide. J. Am. Chem. Soc. 80, 1339–1339 (1958)
Gorle, G., Bathinapatla, A., Chen, Y.-Z., Ling, Y.-C.: Near infrared light activatable PEI-wrapped bismuth selenide nanocomposites for photothermal/photodynamic therapy induced bacterial inactivation and dye degradation. RSC Adv. 8, 19827–19834 (2018)
Deroco, P.B., Vicentini, F.C., Oliveira, G.G., Rocha-Filho, R.C., Fatibello-Filho, O.: Square-wave voltammetric determination of hydroxychloroquine in pharmaceutical and synthetic urine samples using a cathodically pretreated boron-doped diamond electrode. J. Electroanal. Chem. 719, 19–23 (2014)
Hennighausen, Z., Lane, C., Buda, I.G., Mathur, V.K., Bansil, A., Kar, S.: Evidence of a purely electronic two-dimensional lattice at the interface of TMD/Bi2Se3 heterostructures. Nanoscale 11, 15929–15938 (2019)
Ota, J.R., Roy, P., Srivastava, S.K., Popovitz-Biro, R., Tenne, R.: A simple hydrothermal method for the growth of Bi2Se3nanorods. Nanotechnology 17, 1700–1705 (2006)
Xiao, C., Yang, J., Zhu, W., Peng, J., Zhang, J.: Electrodeposition and characterization of Bi2Se3 thin films by electrochemical atomic layer epitaxy (ECALE). Electrochim. Acta. 54, 6821–6826 (2009)
Singh, P., Kim, Y.J., Wang, C., Mathiyalagan, R., Yang, D.C.: The development of a green approach for the biosynthesis of silver and gold nanoparticles by using Panax ginseng root extract, and their biological applications. Artif. Cells Nanomed. Biotechnol. 44, 1150–1157 (2016)
Dun, C., Hewitt, C.A., Huang, H., Xu, J., Montgomery, D.S., Nie, W., Jiang, Q., Carroll, D.L.: Layered Bi2Se3 nanoplate/polyvinylidene fluoride composite based n-type thermoelectric fabrics. ACS Appl. Mater. Interfaces. 7, 7054–7059 (2015)
Liu, M., Spanos, P.D., Yu, S.-H.: Synthesis of ultrathin Bi2Se3 nanosheets/graphene nanocomposite with defects/vacancies-dependent transient photocurrent performance. Nano Energy 64, 103877 (2019)
Zhuang, A., Zhao, Y., Liu, X., Xu, M., Wang, Y., Jeong, U., Wang, X., Zeng, J.: Controlling the lateral and vertical dimensions of Bi2Se3 nanoplates via seeded growth. Nano Res. 8, 246–256 (2015)
Chaiyakun, S., Witit-anun, N., Nuntawong, N., Chindaudom, P., Oaew, S., Kedkeaw, C., Limsuwande, P.: Preparation and characterization of graphene oxide nanosheets. Procedia Eng. 32(759), 764 (2012)
Yang, D., Velamakanni, A., Bozoklu, G., Park, S., Stoller, M., Piner, R.D., Stankovich, S., Jung, I., Field, D.A., VentriceJr, C.A., Ruoffa, R.S.: Chemical analysis of graphene oxide films after heat and chemical treatments by X-ray photoelectron and Micro-Raman spectroscopy. Carbon 47, 145–152 (2009)
Sun, Z., Liufu, S., Chen, L.: Synthesis and characterization of nanostructured bismuth selenide thin films. Dalton Trans. 39, 10883–10887 (2010)
Suvardhan, K., Heba, A.K.: Electrochemical biosensor for the detection of amygdalin in apple seeds with a hybrid of f-MWCNTs/CoFe2O4 nanocomposite. Curr. Anal. Chem. 16, 660–668 (2020)
Savariraj, A.D., Vinoth, V., Mangalaraja, R.V., Arun, T., Contreras, D., Akbari-Fakhrabadi, A., Valdésc, H., Banat, F.: Microwave-assisted synthesis of localized surface plasmon resonance enhanced bismuth selenide (Bi2Se3) layers for non-enzymatic glucose sensing. J. Electroanal. Chem. 856, 113629 (2020)
Ghodsi, J., Rafati, A.A., Shoja, Y.: First report on hemoglobin electrostatic immobilization on WO3 nanoparticles: application in the simultaneous determination of levodopa, uric acid, and folic acid. Anal. Bioanal. Chem. 408, 3899–3909 (2016)
Teixeira, M.F.S., Marcolino-Júnior, L.H., Fatibello-Filho, O., Dockal, E.R., Bergamini, M.F.: An electrochemical sensor for l-dopa based on oxovanadium-salen thin film electrode applied flow injection system. Sens. Actuators B Chem. 122, 549–555 (2007)
Aslanoglu, M., Kutluay, A., Goktas, S., Karabulut, S.: Voltammetric behaviour of levodopa and its quantification in pharmaceuticals using a β-cyclodextrine doped poly (2,5-diaminobenzenesulfonic acid) modified electrode. J. Chem. Sci. 121, 209–215 (2009)
Kemmegne-Mbouguen, J.C., Toma, H.E., Araki, K., Constantino, V.R.L., Ngameni, E., Angnes, L.: Simultaneous determination of acetaminophen and tyrosine using a glassy carbon electrode modified with a tetraruthenated cobalt(II) porphyrin intercalated into a smectite clay. Microchim. Acta. 183, 3243–3253 (2016)
Liu, R., Zeng, X., Liu, J., Luo, J., Zheng, Y., Liu, X.: A glassy carbon electrode modified with an amphiphilic, electroactive and photosensitive polymer and with multi-walled carbon nanotubes for simultaneous determination of dopamine and paracetamol. Microchim. Acta. 183, 1543–1551 (2016)
Wang, S.-F., Xie, F., Hu, R.-F.: Carbon-coated nickel magnetic nanoparticles modified electrodes as a sensor for determination of acetaminophen. Sens. Actuators B Chem. 123, 495–500 (2007)
Baghayeri, M., Namadchian, M.: Fabrication of a nanostructured luteolin biosensor for simultaneous determination of levodopa in the presence of acetaminophen and tyramine: application to the analysis of some real samples. Electrochim. Acta. 108, 22–31 (2013)
Babaei, A., Sohrabi, M., Taheri, A.R.: Highly sensitive simultaneous determination of l-dopa and paracetamol using a glassy carbon electrode modified with a composite of nickel hydroxide nanoparticles/multi-walled carbon nanotubes. J. Electroanal. Chem. 698, 45–51 (2013)
Acknowledgements
We are grateful for the financial support of the Ministry of Science and Technology, Taiwan (MOST 104-2113-M-007-008-MY3 and MOST 104-2923-M-007-002-MY3) and the National Tsing Hua University for this work.
Author information
Authors and Affiliations
Contributions
The manuscript was written by G.G and AB through the contributions of all authors. G.G, A.B, and S.K. conceived ideas and G.G, A.B carried out the experiments and interpreted the results. YCL and MR supervised the study. All authors read and approved the final manuscript.
Corresponding authors
Ethics declarations
Conflict of interest
The authors declare no conflict of interests.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Gorle, G., Bathinapatla, A., Kanchi, S. et al. Low dimensional Bi2Se3 NPs/reduced graphene oxide nanocomposite for simultaneous detection of L-Dopa and acetaminophen in presence of ascorbic acid in biological samples and pharmaceuticals. J Nanostruct Chem 12, 513–528 (2022). https://doi.org/10.1007/s40097-021-00428-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s40097-021-00428-3