Introduction

In recent years, the use of electrochemical methods was considered as an alternative in the detection and analysis of food [1] and drugs [2,3,4,5] due to its wide range of applications, ease of use, wide variety of electrodes, and speedy readout. They can be used to measure trace levels of substances [6] and for the determination of exosomes from certain diseases [7]. They also offer excellent sensitivity and specificity and provide fast, reliable, and early detection of cancer metastasis [8].

Moreover, nanoparticles inclusion to electrodes has significant advantages such as enhancing active surface area, mass transport, long-term stability, multiple functionalization, amplification of signals, and catalytic activity [1, 9, 10]. Cr/ZnO is an example of these nanoparticles having a variety of applications, including the photolytic degradation of aniline and the removal of nitrogen oxide pollutants. Different techniques have been utilized to fabricate ZnO and ZnCr2O4 including electrochemical deposition, hydrothermal, chemical vapor deposition, sol–gel, and co-precipitation approach [11, 12].

A literature survey revealed that there is no electrochemical method for determining CLT. In this work, scalable and cost-effective chemical co-precipitation method was utilized to prepare ZnCr2O4/MWCNTs which has been prepared and characterized. The objective of the present study is to develop a convenient and sensitive method for the determination of CLT based on the fabricated and characterized modified electrode in its dosage form, plasma and urine samples. Electrochemical performance of the drug was assessed by CV and DPV. Finally, the produced method was assessed as an environmental ecofriendly technique.

CLT (Figure 1S) is white or yellowish-white crystalline powder. It is practically insoluble in water, chloroform, and ether and soluble in methyl alcohol [13]. CLT is an orally administered thiazide-like diuretic used to control hypertension and edema, including that concomitant with heart failure [14]. Numerous analytical methods have been established for the estimation of CLT including spectrophotometric[15,16,17,18], spectrofluorimetric [19], HPLC [20,21,22,23,24,25], chemometrics [25], TLC [26, 27], capillary zone electrophoresis [28], LC–MS-MS [29, 30], ultrafast liquid chromatography [31], and supercritical fluid chromatography methods [32].

Experimental

Instruments

Voltammetric assay was done using Bio-logic SP 150 electrochemical workstation attached to a specialized computer. The fabricated sensors were CPE, ZnO/CPE, ZnCr2O4/CPE, or ZnCr2O4/MWCNTs /CPE. X-ray diffractometer (XRD; Rigaku Smart Lab.) was employed to investigate the microstructure properties of the fabricated samples through 2θ changed between 20° and 80°. The elemental chemical composition and purity of ZnO, spinel ZnCr2O4, and ZnCr2O4/CNTs were characterized by energy-dispersive X-ray analysis (EDX; JEOL-JSM-7600F). Sputter coater (Model, EMS 150 T ES) was used to coat the nanopowder by iridium. To define the mean size and particle distribution, transmission electron microscopy (TEM; Hitachi-H-7500, Japan) was performed at 80 kV. Further, pH meter Jenway, UK 3510, and sonicator (cleanwise®) model WUC-A06H (Korea) were used during the preparation of the samples.

Materials and reagents

CLT pure sample was kindly provided by Egyptian Co for Pharmaceutical and Chemical Industries (10th of Ramadan City), Cairo, Egypt. The purity was (99.00 ± 0.21) as referred by the supplier. Hygroton® containing 50 mg CLT was purchased from local market. Methanol, highly pure graphite powder (10–20 µm), paraffin oil, Zn (CH3COO)2.2H2O, and Cr (NO3)2·4H2O were purchased from Sigma-Aldrich, Germany. Dipotassium hydrogen phosphate (K2HPO4), dihydrogen potassium phosphate (KH2PO4), orthophosphoric acid, and sodium hydroxide were purchased from El-Nasr Company, Egypt. Phosphate buffer solution (0.1 mol L−1) composed of a mixture of 1 mol L−1 K2HPO4 and 1 mol L−1 KH2PO4; pH was adjusted using 0.1 mol L−1 H3PO4 and 0.1 mol L−1 NaOH.

Standard solution

Stock solution of CLT (1 × 10−3 mol L−1) was prepared by dissolving 33.87 mg of CLT in 70 mL of methanol and shaken for 15 min, and then volume was completed to 100 mL with methanol.

Preparation of ZnO, ZnCr2O4 and ZnCr2O4/ MWCNTs nanoparticles

Un-doped ZnO was prepared via chemical precipitation approach at room temperature. Firstly, to 65 mL 1 M aqueous solution zinc acetate dihydrate (Zn (CH3COO) 2. 2H2O), 65 mL of 2 M sodium hydroxide (NaOH) was added dropwise under vigorous stirring. At pH ~ 10, a clear white precipitate of zinc hydroxide (Zn (OH)2) was obtained. After completion of the reaction, the obtained white solid precipitate was filtered and washed with deionized water, dried at 70 °C for 12 h, and finally annealed in a furnace at 400 °C for 3 h. On the other side, the spinel compound ZnCr2O4 was prepared by dissolving 0.2 mol zinc acetate and 0.3 mol chromium nitrate Cr(NO3)2·4H2O) into 50 mL and 70 mL deionized water, respectively. Thereafter, 80 mL NaOH solution was carefully added till gray white powder was obtained at approximately pH 9. The formed powder was filtered, washed, dried, and calcined at the same previous procedures. The nanocomposite ZnCr2O4/ MWCNTs was prepared by dissolving 0.05 g ZnCr2O4 into 15 mL MWCNTs (0.05 g MWCNTs into 50 mL deionized water). After that, the solution was heat-treated in a microwave oven. The resulting precipitate was centrifuged, washed many times, and left for drying [33].

Electrode fabrication

Carbon bare electrode was constructed by mixing 0.4 g graphite powder and 0.2 mL paraffin oil using a pestle and mortar. The formed homogenous paste was filled into the cavity of the sensor, and the surface was smoothed out to obtain a glossy appearance. Modified electrodes ZnO, ZnCr2O4, and ZnCr2O4/MWCNTs were fabricated by adding nanoparticles in a the ratio of 6–12% to 0.6 g graphite powder and 0.4 mL paraffin oil to create a uniform paste. All prepared sensors were constructed in a similar way as previously stated.

Electrochemical procedure

The voltammetric cell was filled with 25 mL of phosphate buffer of pH 5.0; then a suitable volume of CLT standard solution was used to get a concentration of 1 × 10−4 mol L−1. All prepared electrodes were subjected to a definite voltage for a specified time. After the stated time, the potential and stirring were on hold for 6.0 s. All samples were determined in the same condition. Finally, differential pulse voltammograms were determined at the optimum state in DPV in a range 0.1–9 μmol L−1 with a scan rate of 100 mV/s, pulse amplitude of 20 mV, equilibrium time of 5 s, and a step potential of 5 mV.

Application to dosage form

Twenty Hygroton® tablets containing 50 mg CLT were accurately weighed and finely ground, and an amount of the fine powder equivalent to one tablet was transferred into a 100-mL volumetric flask, to which 60 mL methanol was added. After vigorously shaking for ten minutes, the flask was sonicated for 15 min, completed to the final volume with the same solvent, and then filtered. Further dilutions with phosphate buffer (pH 5) were done to prepare different concentrations of CLT; then the obtained solution was centrifuged at 5000 rpm for 15 min. The general procedure was repeated using aliquots covering the working concentration range, and the concentrations of CLT were calculated using the regression equation.

Spiked human plasma

Human plasma samples obtained from healthy individuals immediately prior to analysis were diluted five times using phosphate buffer (pH 5) to minimize the matrix effects prior to analysis. The samples were then spiked with suitable different concentrations of the drug (0.3–9 µmol L−1). CLT concentrations were determined in the plasma by the proposed method using the regression equation, and the recovery percent (%R) was determined.

Spiked human urine

A drug-free urine sample was provided by healthy non-smoking volunteer. The urine samples were spiked with suitable concentrations of CLT then centrifuged at 5000 rpm for 10 min to reduce the effect of any unexpected endogenous materials. The clear supernatant was diluted with phosphate buffer (pH 5) spiked with suitable concentrations of CLT (0.3–9 µmol L−1) and then completed to volume with the buffer. CLT was determined in the urine as mentioned above, and the drug concentrations were calculated from the corresponding regression equation.

Results and discussion

Characterization of ZnO, ZnCr2O4, and ZnCr2O4 / MWCNTs nanocomposites

XRD, EDX, and TEM spectroscopy were used to explore the structural, chemical composition, and mean particle size of the nanoparticles ZnO, ZnCr2O4, and ZnCr2O4/ MWCNTs. As can be seen from the XRD pattern in Fig. 1, ZnO has a polycrystalline structure of sharp, narrow, and high-intensity peaks suggesting a large crystallite size and well crystal structure. The diffraction peaks located at 2θ = 32.27°, 34.85°, 36.67°, 47.95°, 56.93°, 63.30°, 66.83°, 68.29°, 69.61°, 72.97°, and 77.37° according to the typical reflection planes (100), (002), (101), (102), (110), (103), (200), (112), (201), and (004) coincide with the standard card of wurtzite hexagonal structure ZnO (JCPDS. 79–2205, space group P63mc). No other phases related to hydroxyl species or chemical salts existed in the spectrum [34, 35]. Besides, the nanostructures ZnCr2O4 exhibited wide peaks attributed to the small crystalline size. The characteristic diffraction peaks located at 30.30°, 35.73°, 43.31°, 54.07°, 57.47°, 62.83°, and 74.69° refer to the (220), (311), (400), (422), (511), (440), and (533) planes are indexed to the spinel cubic phase of zinc chromium oxide (ZnCr2O4, JCPDS 87-0028, space group Fd-3 m) [36, 37]. Although with the closeness of ionic radius of Zn2+ (0.074 nm) to Cr3+ (0.063 nm) and electronegativity of Zn (1.65) compared with Cr (1.66), the phase was modified to the spinel structure due to the high amount of Cr3+ replacements. Additionally, the nanocomposite ZnCr2O4/MWCNTs showed deterioration structure in which most of the peaks of the spinel compound disappeared by MWCNTs inclusion. Only the weak reflection peaks of the planes (311) and (440) were observed in the spectrum. Moreover, a broad peak associated with the (002) plane of graphitic structure was detected at approximately 26.60°. It is worthy to note that the low degree of crystallinity was due to the lower calcination temperature as well as the combination of amorphous structure (MWCNTs) and crystalline phase of ZnCr2O4 [38, 39].

Fig. 1
figure 1

XRD patterns of ZnO, ZnCr2O4, and ZnCr2O4 /MWCNTs

To affirm the microstructure of the nanoparticles, the crystallographic parameters including the crystallite size (D), the dislocation density (δ), the degree of crystallinity (X_c), and the lattice strain (ε) were evaluated using the following equations [40,41,42]:

$$ D = k\lambda {/}\beta \cos \theta $$
(1)
$$ \delta = 1{/}D^{2} $$
(2)
$$ X\_c = \beta /0.24 $$
(3)
$$ \varepsilon = \beta {/}\left( {4\;\tan \theta } \right) $$
(4)

Equation 1 represents Debye–Scherrer formula where λ is the wavelength of the incident X-ray radiation, K is the Scherrer’s constant (the shape factor) ~ 0.94, θ is the angle of the diffracted X-ray radiations (Bragg angle), D is the average crystallite size, and β is the width at half maximum (FWHM) recorded in radian. The obtained XRD data are presented in Table 1. As summarized in the table, ZnO demonstrated a big crystallite size compared to the spinel ZnCr2O4 which suddenly decreased to around 10 nm. The impact of size confinement is very useful in most of biological and electrochemical applications in which the surface area was significantly increased. Moreover, the degree of crystallinity was decreased, whereas the strain and dislocation density were increased due to the increase of Cr3+ ion defects.

Table 1 The crystallographic parameters of the nanostructures ZnO, ZnCr2O4, and ZnCr2O4/MWCNTs

The elemental composition of the prepared samples was recorded using EDX spectra. Figure 2a illustrates the EDX pattern of ZnO including zinc (Zn) and oxygen (O) elements. However, the spectrum of spinel ZnCr2O4 (Fig. 2b) revealed the presence of chromium ions which clearly assure the surface modification and again confirm the grown spinel ZnCr2O4 with no further peaks related to other elements. Figure 2c shows the EDX spectrum of ZnCr2O4 /MWCNTs composed of the elements Zn, O, Cr, and C [43]. The strong carbon peak detected in the spectrum displayed that the MWCNTs completely covered the spinel lattice which is consistent with the XRD behavior. Figure 3A–D depicts the EDX color mapping of the elements Zn, O, C, and Cr which were homogeneously dispersed [44].

Fig. 2
figure 2

EDX patterns of ZnO nanorods (a), ZnCr2O4 (b) and ZnCr2O4/MWCNTs (c)

Fig. 3
figure 3

EDX analysis of A Oxygen, B Zinc, C Carbon and D Chromium

Figure 4a–c describes the TEM micrographs of the nanostructures. The TEM of ZnO shows the nanoparticles in spherical–hexagonal shape with mean size varied between 30 and 40 nm (Fig. 4a). Besides, the spinel ZnCr2O4 displayed a quasi-spherical particles of small diameter ~ 15 nm (Fig. 4b). Compared to ZnO, the particles of the spinel compound revealed a relative uniform distribution [45]. The TEM of the nanocomposite ZnCr2O4/MWCNTs depicted spherical nanoparticles decorated with CNTs (Fig. 4c) [46]. Some of the nanoparticles were aggregated together due to the small particle size and large surface area. It is worthy to note that the obtained results from the TEM micrographs were consistent with the XRD behavior.

Fig. 4
figure 4

TEM micrographs of a ZnO, b spinel ZnCr2O4, and c ZnCr2O4/MWCNTs nanocomposite

Electrochemical behavior of CLT at different sensors

Large surface area of the electrodes is a very important as it improves electrochemical activity and hence analytical performance. The electrodes active surface area can be determined by CV method consuming a solution of (1 × 10−3 mol L−1) K4 [Fe (CN)6] in 0.1 mol L−1 KCl for the reaction using Randles–Sevcik equation [47].

$$ Ipa = \left( {2.69 \, \times 10^{5} } \right)n^{3/2} A_{0} C_{0} D_{0}^{1/2} \upsilon^{1/2} $$

The active surface area was estimated from the previous equation through the obtained slope. ZnCr2O4/MWCNT/CPE shows irreversible oxidation reaction behavior toward CLT (Fig. 5). The response of ZnCr2O4/MWCNTs was higher than the other modified electrodes ZnO/CPE, ZnCr2O4/CPE, and bare CPE. Modified electrode appears to increase electrochemical activity due to its large intrinsic surface area, and it enhances the transfer of electrons leading to the improvement of the electrochemical reaction. The active surface area of ZnCr2O4/MWCNTs electrode was 0.291 compared to 0.199, 0.151, and 0.054 for ZnCr2O4, ZnO, and bare CPE sensors, respectively. A solution contains (6 μmol L−1) CLT was determined at a pH of 5 and a scan rate of 100 mV/s and the response of these four novel electrodes were compared; it was found that ZnCr2O4 MWCNTs/CPE showed a greater response than other electrodes. ZnCr2O4/ MWCNTs /CPE shows significant enhancement in the peak current due to increase in the electroactive surface area and electrocatalytic activity (Figure 2S).

Fig. 5
figure 5

CV of ZnCr2O4/MWCNTs/CPE behavior for 1 × 10−4 mol L−1 CLT in PBS of pH 5 at scan rate of 100 mV/s

It was found that 9% ZnCr2O4/MWCNTs NPs gave excellent response as verified by DPV (Figure 3S), while higher concentrations were found to be unsuitable owing to reduction of the electrode active area and block the electrode surface.

Optimization of the experimental conditions

Effect of pH

Phosphate buffer of pH range from 2 to 7 was tried to determine the suitable PH for ZnCr2O4/MWCNT/CPE using the same CLT concentration (6 µmol L−1). Shifting of the anodic peak occurred due to participation of electrons in the oxidation process as shown in Figure 4S (A). The protons to the electrons ratio was 1:1, and the reaction slope was 0.050, which was relatively close to the Nernstian hypothetical value (0.059). Consequently, pH had important effect on the reaction (Figure 4S) (B).

$$ Epa\;\left( {\text{V}} \right) = - 0.050\;{\text{pH}} + 1.096 $$
(5)

Scan rate optimization

Scan rate effect on the oxidation of CLT solution (1 × 10−4) mol L−1 was investigated by measuring the response of the sensor using scan rates range from 20 to 140 mV/s (Figure 5S). The obtained results suggest that the oxidation behavior of CLT was due to mixed diffusion and adsorption mechanism on the ZnCr2O4/MWCNTs electrode. Upon representing the log of peak current versus log of the scan rate, a linear relationship was obtained (Figure 5S) (inset B). The obtained slope was 0.797 which confirm mixed diffusion and adsorption mechanism for CLT oxidation.

$$ {\text{Log}}\;Ip = 0.91 + 0.797\;\log \;\nu $$
(6)

Diffusion of molecules from a great concentration to a small concentration was the principle of the mechanism of the electrode sensing. The electrons numbers contributing in an electrochemical process can be determined using Laviron equation [48].

$$ E = \, E^{o} + \left( {\frac{2.303 RT}{{anF}}} \right)\;\log \;\left( {\frac{{RTK^{^\circ } }}{anF}} \right) + \left( {\frac{2.303RT}{{anF}}} \right)\log \upsilon $$

Upon drawing log scan rate (log υ) against potential (Figure 5S (Inset C)), α n can be calculated from the obtained slope, where n is the number of electrons transmitted and α is the electron transfer coefficient.

$$ E_{p} \left( V \right) = 0.055 \, \log \upsilon + 0.899 $$

The slope of the last equation is 0.055, and α n is 1.07. As CLT electro-oxidation process is irreversible, α was supposed to be 0.5 and n was determined to be ≈ 2, which is in agreement with the suggested electro-oxidation mechanism shown in Scheme 1S.

Determination of CLT in pure form

Oxidation of CLT on ZnCr2O4/MWCNTs/CPE at applied potential range − 0.2–1.4 V. CLT displayed an oxidation peak at 0.847 V by DPV. The method was found to be linear from 0.1–9 μmol L−1, and the regression parameters are shown in Table 2.

Table 2 Regression parameters for CLT determination at ZnCr2O4/MWCNTs/CPE

Methods validation

Under the above-mentioned experimental conditions, the calibration graph was constructed as shown in Figure 6S and the linear regression parameters of CLT were determined and presented in Table 2.

LOD and LOQ were determined using the following equations:

$$ \begin{aligned} & {\text{LOD}} = 3.3 \, \sigma {/}S \\ & {\text{LOQ}} = 10 \, \sigma {/}S \\ \end{aligned} $$

where σ is the residual standard deviation of a regression line and S is the slope of the calibration curve. The values summarized in Table 2 demonstrate that the suggested method was sensitive for detection of low CLT concentrations.

Accuracy was assessed as % recovery of CLT concentrations and found be near to the theoretical value. The values are summarized in Table 2.

Three different CLT concentrations were determined in the same day and in three successive days to estimate intraday and interday precision of the fabricated ZnCr2O4/MWCNTs electrode. The precision as percent relative standard deviation (RSD %) was estimated (Table 2), and the technique appeared a worthy precision for CLT estimation.

Robustness refers to the capacity of an analytical method to be unaffected by slight changes without the occurrence of unexpected differences in the obtained results [49]. Upon small variation in a definite method parameters such as the response time (10 s ± 0.3 s) and change of pH (5 ± 0.1), the response of CLT stayed relatively unchanged, confirming robustness of the procedure. The reusability was estimated by recording the response of a sensor used before and that of the recently synthesized sensor (more than ten times). Similar responses explain that the sensor can be reused. The reproducibility of the proposed electrode was determined by construction of six sensors under the optimum conditions, and %RSD was found to be 1.650, confirming that acceptable reproducibility. Within 30 days, sensor's stability was tested by recording the produced current. The peak current was remained up to 98% of its initial response through this period. As a result, the suggested sensor shows an excellent degree of reliability.

Application to dosage form

The developed procedure was useful for the quantification of CLT in tablets. The obtained results were in good consistency with the label claim, demonstrating that there is no interference from excipients and additives. DPV technique was applied to measure CLT successfully in tablets at ZnCr2O4/MWCNT/CPE electrode. The validity of the suggested method was further evaluated by the standard addition technique where acceptable results were attained (Table 3). By comparing the results obtained for determination of CLT in tablets with those of a published HPLC method [20], no important differences were found by applying t-test and F-test as shown in Table 4. The results obtained from ANOVA test (Table 1S) approve the accurate evaluation of CLT in the bulk and in tablet. Moreover, the developed procedure is more sensitive than the published procedures (Table 2S).

Table 3 CLT determination by standard addition technique at ZnCr2O4/MWCNTs/CPE in commercial tablets
Table 4 Statistical comparison of the developed method with the reported method for CLT estimation

Application to spiked human plasma and urine

CLT was determined successfully in human plasma and urine. Oral administration of 25 mg per dose leads to absorption of above 75% of CLT to reach peak plasma concentration of about (192.2 ng/ml) after meal and (200.1 ng/ml) throughout fasting. The amount excreted unchanged in the urine was found to be about 27% of the dose [50]. The published methods cannot be applied for determination of CLT in plasma because the c max is out of their linearity, which suggest the need for the developed method. Remarkably, excellent results of CLT estimation in spiked plasma and urine were achieved; Table 5 confirms the ability of the developed method for the estimation of CLT without any interference in spiked plasma and urine samples.

Table 5 Validation parameters for the quantification of CLT in spiked human plasma and urine samples by DPV

Study of the electrode selectivity

The selectivity of the (ZnCr2O4/MWCNTs/CPE) to CLT was important parameter. The interference exhibited by materials found or introduced in the same dosage form with CLT was determined. Valsartan (VAL) as angiotensin receptor blockers has been widely used in combination with CLT (a potent diuretic). VAL was effective and safe to be administered with CLT in the same dosage form. The interference was determined by adding different VAL concentrations to fixed CLT concentration in phosphate buffer (pH 5.0), and the voltammetric current responses were recorded. It was observed that there was no significant variation in CLT oxidation peak current with increasing VAL concentrations and very small %RSD demonstrates that there is no significant interference confirming the high selectivity of the prepared electrode toward CLT (Figure 7S).

Assessment of the greenness of the proposed method

An important step nowadays in any established method is evaluating its greenness and impact on the environment. The Eco-scale assessment technique is depended on penalty points deducted from a base of 100. The novel constructed sensor was evaluated for its greenness by calculating penalty points, including instruments, reagents, and waste [51]. A high score indicates that the method is as smart green. It was found that the proposed method scored 83, as summarized in Table 3S, demonstrating that this novel fabricated electrode was considered as environmentally friendly.

Conclusion

The present work develops an electrochemical method based on modification of CPE by the incorporation of ZnCr2O4/MWCNTs to determine CLT in pure, dosage form, and biological fluids. ZnCr2O4/MWCNTs/CPEs electrode was found to enhance electrical conductivity more than unmodified CPE electrode. The developed method can effectively determine CLT with low detection limit, high sensitivity, selectivity, good reproducibility, and repeatability; it extended for determination of CLT in plasma and urine.