Introduction

Interactions between electrons and protonated peptides compose a family of processes each of which is defined by the kinetic energy of the electrons (Table 1). Collectively, the preceding processes have come to be generically referred to as electron-induced dissociation (EID) [1315].

Table 1 Cationic Dissociation Precursors Resulting from Protonated Peptides via the Reaction [M + nH]n+ + e → Dissociation Precursor + ae → Fragments

A number of studies carried out in Fourier-transform ion cyclotron resonance (FT-ICR) mass spectrometers have shown that the norm under electron-ionization-dissociation conditions (high-energy EID, Reaction 7) is higher sequence coverage than typically observed in product-ion spectra produced by a single dissociation process. Fung et al. [12] showed that singly and multiply charged peptides and proteins cleave at N–Cα bonds to produce c/z-type fragments and secondarily at C–C bonds to produce a/x-type fragments. Ly et al. [16] investigated the technique’s potential for generating residue-specific fragmentation of singly charged peptides, and Sargaeva et al. [17] demonstrated that the technique can be used to determine the presence and the position of isoaspartic acid residues in amyloid β peptides. Enyenihi and coworkers [18, 19] implemented an electron-capture dissociation ECD capability in a linear ion trap and used this instrument to perform comparative collision-induced/electron-capture/electron-ionization dissociation analyses of singly and multiply charged peptides, including sodiated and phosphorylated, and sodiated oligosaccharides. These authors observed that high-energy EID of phosphorylated peptides resulted in extensive backbone cleavage during which phosphorylation is largely conserved. Enyenihi [19] also found that small sodiated peptides (five residues) lose the C-terminal amino acid residue as well as certain side chains and, further, that the sugar monomers of sodiated oligosaccharides undergo cross-ring cleavages that can aid structural characterization. More recently, Kaczorowska and Cooper [20] showed that the technique can be applied in analyses of singly-charged electrosprayed ions of octaethylporphyrin (OEP) and its iron(III) complex to produce singly and doubly charged fragment ions unlike any observed in electron ionization and collision-induced dissociation (CID).

Kalli and Hess [15] produced singly, doubly, and triply charged hydrogen deficient peptide radicals, [M + nH](n+1)+• (n = 0, 1, 2), from corresponding [Cu(II)(terpy)(M + nH)](n+2)+• complexes by isolating the latter in the linear ion trap of an FT ICR mass spectrometer system and subjecting them to CID. The radical cations so produced were subsequently fragmented in the ICR cell by collision-induced dissociation, infrared multiphoton dissociation, and electron-induced dissociation in order to compare the fragmentation pathways of the three processes. Regardless of the process used, fragmentation of triply charged radical cations, of the same sort investigated in the present study, was found to proceed through both radical- and charge-driven processes that result in the formation of a wide range of amino acid side-chain (SC) losses and a-, b-, c-, y-, x-, and z-type backbone product ions very similar to those observed under electron-ionization-dissociation conditions with an FT ICR mass spectrometer.

Despite the preceding demonstrations of its promise as a useful structural tool, electron-ionization-dissociation conditions have been underutilized in mass spectrometry of peptides and proteins. This may be due in large part to the fact that for the present, analyses under these conditions can only be performed with FT ICR mass spectrometers and that on this instrument platform, they can be a difficult experiment to carry out. Recent advances in FT ICR technology have to a large degree mitigated this problem [21], but as yet, there is no evidence in the literature of increased application of electron-ionization-dissociation conditions.

In 2008, the present authors introduced an electromagnetostatic (EMS), electron-inducing dissociation cell [22] that can be retrofitted into triple quadrupole (QqQ) [2226] and hybrid quadrupole/time-of-flight (QqTOF) [27] mass spectrometers. In the course of an analysis of Substance P aimed at demonstrating the utility of this device in a QqTOF mass spectrometer for ECD and complementary ECD/CID analyses of peptides, the doubly protonated precursor was exposed to electrons with energies ranging up to 50 eV. As a result, [M + 2H]3+• ions and fragments resulting from monomolecular decomposition of this triply charged radical appeared in the product-ion spectrum [27]. The analyses described in this report expand on that initial observation of high-energy EID in a radio-frequency-free electromagnetostatic (EMS) cell.

Experimental

Materials and Sample Preparation

Authentic standards of Substance P (RPKPQQFFGLM-NH2), MW = 1346.7 (mono.); ACTH (SYSMEHFRWGKPVG), MW = 1679.8 (mono.); neurotensin (pyroELYENKPRRPYIL), MW = 1671.9 (mono.); tyrosine kinase peptide 3 (RRLIEDAEYAARG-NH2), MW = 1517.8 (mono.); and phosphorylated tyrosine kinase peptide 3 (RRLIEDAEpYAARG-NH2), MW = 1597.8 (mono.) were purchased from American Peptide Co. (Sunnyvale, CA, USA). Each of these peptide standards was dissolved in 50% MeOH containing 0.1% formic acid to a final concentration in the range of 20-50 μg/mL.

Mass Spectrometry

All mass spectrometry was performed using a modified Agilent G6460 electrospray ionization (ESI), QqQ mass spectrometer system (Agilent Technologies, Santa Clara, CA, USA). This instrument and the EMS cell have been described in detail elsewhere [25]. Briefly, the mass spectrometer was modified by shortening the original radiofrequency (rf) hexapole CID cell (Q2) by 40 mm and retrofitting a rf-free EMS ECD cell into the space created between the first quadrupole and the shortened CID cell (Figure 1a). From entrance to exit arranged concentrically along a straight axis, the EMS cell comprises an aperture plate, a Sm2Co17 disc-magnet, an electromagnet, and a tungsten-rhenium filament held within a chamber that also serves as an electrostatic lens. The energy of the electrons in the cell was defined by the potential difference between the electron emitter and the electromagnet. In each analysis, the electron energy was adjusted to maximize the yield of the most abundant peak in the EID product-ion spectrum; in all instances reported herein, this setting was in the range of 65–75 eV, which corresponds to that commonly used in electron ionization mass spectrometers.

Figure 1
figure 1

Arrangements and operational modes of the EMS cell and radio-frequency hexapole CID cell (Q2) in the analyzer section of the Agilent G6460 for: (a) high-energy EID as performed in this study, (b) high-energy EID followed by CID, and (c) collisional ion activation followed by high-energy EID

Each peptide solution was electrosprayed at a flow rate of 30 μL/min. Doubly protonated precursors ([M + 2H]2+) were selected by the first quadrupole mass analyzer (Q1) for exposure to energetic electrons in the EMS cell. The shortened CID cell (Q2) located downstream of the EMS cell was operated in a transmission mode only. The second quadrupole mass analyzer (Q3) produced mass spectra of the EID fragments and nondissociated precursors.

Results and Discussion

The high-energy EID product-ion mass spectrum of doubly protonated Substance P (Figure 2, Table 2) exemplifies the EMS cell’s performance and provides a basis for comparison to that of a commercial FT-ICR instrument. Fung et al. [12] identified 46 ion species among the ion signals in their FT-ICR high-energy EID product-ion spectrum of Substance P (Figure 2a, Table 2). Excluding a1 + and b1 +, which lie outside the m/z range scanned with the Agilent G6460 used in this study, slightly more than three-quarters (35 out of 44) of the ion signals recorded in the EMS high-energy EID spectrum (Figure 2b) have measured m/z values that fall within ±0.4 of those assigned identities the FT-ICR spectrum recorded by Fung et al. (Table 2). Aside from the precursor ([M + 2H]2+, m/z 674.5), the most prominent signals in the FT-ICR and EMS cell spectra alike are due to the triply charged radical cation ([M + 2H]3+•, m/z 449.7), the radical cation putatively formed [12] from the latter species by the loss of methionine’s SC ([M + 2H]3+• – Msc (74.0 Da), m/z 424.8), and the loss of ammonia respectively from the preceding two species ([M + 2H]3+• – NH3, m/z 443.6; [M + 2H]3+• – Msc (74 Da) – NH3, m/z 419.1). The ratios of the signal intensities of these radical cations to the signal strength of [M + 2H]3+• in the product-ion spectrum of Substance P produced with the EMS cell match within reasonable experimental limits those observed in the FT-ICR high-energy EID spectrum.

Figure 2
figure 2

High-energy EID product-ion mass spectra of Substance P: (a) recorded with an FT ICR mass spectrometer (reprinted with permission from reference [12]. Copyright 2009 American Chemical Society); (b) recorded with the EMS QqQ mass spectrometer used in the present study. In both panels the EID precursor is the even electron species [M + 2H]2+; fragmentation also proceeds from the hydrogen-abundant reduced radical cations [M + 2H]+• and the hydrogen-deficient oxidized radical cations [M + 2H]3+•

Table 2 Comparison of Substance P m/z Values Measured via QqQ EMS EID and FT ICR EID (Latter Reproduced with Permission from Reference [12]. Copyright 2009 American Chemical Society)

The range of peptide backbone fragmentation evident in high-energy EID product-ion mass spectra (e.g., Figure 2, Table 1) runs the gamut from a/x-type to c/z-type cleavages, most of which can be associated with recognized processes (Table 1). As has been noted in the literature [12, 19] and is readily seen in the high-energy EID mass spectrum of Substance P, dissociation can proceed from the even electron precursor ions, i.e., the species selected by Q1 (reactions 3 and 6, Table 1; precursor [M + 2H]2+, Figure 2), the hydrogen-abundant reduced radical cations formed by capture of electrons (reactions 2 and 4, Table 1; [M + 2H]+•; Figure 2), and the hydrogen-deficient oxidized radical cations produced from tandem ionization (reaction 7, Table 1, [M + 2H]3+•; Figure 2). The singly and doubly charged b- and y-ion signals seen in the Substance P spectrum have been attributed [12] to C–N bond cleavages (the sort typically observed in CID product-ion spectra) induced by inelastic ion-electron collisions (reaction 3, Table 1). The c/z-type ion signals have been ascribed [12, 19] to dissociation of the charge-reduced radical cations formed by capture of low energy electrons (reaction 2, Table 1). HECD (reaction 4, Table 1) has been credited [12] with the appearance of the singly and doubly charged a/x-ion-signals as well as singly charged c/z-type ion signals observed in Substance P’s high-energy EID product-ion spectrum. The appearance of such a broad range of fragment types in Substance P’s high-energy EID product-ion spectrum supports the general conclusion drawn by earlier researchers that electron ionization in and of itself does not necessarily result in dissociation of the resulting oxidized radical cations [12, 28].

Signals for the three doubly charged ions c4 2+, c5 2+, and c6 2+, which were recorded in the FT-ICR spectrum but could “not be attributed to either of” the preceding processes [12], are not present in the EMS cell’s spectrum. The absence of signals for these three ion species as well as those for b7 2+, a4 +, y4 +, b4 +, b5 +, y5 +, and y9 + (all with the exception of a4 +, are EIEIO-type fragmentation products) from the spectrum produced with the EMS cell is not surprising when the Agilent G6460’s limited resolving power (at least three orders of magnitude less than that of the FT-ICR) and the EMS and ICR cells’ distinctly different high-energy EID (e.g., electron-energy distribution) conditions are taken into account.

Enyenihi detailed a method for exploiting the appearance of a/b/c-type and x/y/z-type triplet signals in electron-ionization-dissociation product-ion spectra to distinguish between N- and C-terminal fragments in de novo peptide sequencing [19]. Since for a given residue number the difference in mass between an a/b-type ion pair is 28 Da and that between a b/c-type ion pair is 17 Da, the presence of three mass peaks in a high-energy EID spectrum whose differences in order of increasing mass are respectively 28 and 17 Da would indicate that these peaks compose an a/b/c-triplet corresponding to an N-terminal peptide fragment. By similar reasoning, it is easy to determine that the presence of three mass peaks in a high-energy EID spectrum whose differences in order of increasing mass are respectively 26 and 16 Da would indicate that these peaks compose an x/y/z-triplet corresponding to a C-terminal peptide fragment. The high-energy EID product-ion spectrum of Substance P (Figure 2b, Table 2) provides an excellent example of how Enyenihi’s method could in principle be applied. Specifically, it contains four series of three mass peaks (nominally m/z 226/254/271, 579/607/624, 707/735/752, and 854/882/899). In this particular case, these four series are readily seen to correspond, respectively, to the N-terminal Substance-P triplets a2 +/b2 +/c2 +, a5 +/b5 +/c5 +, a6 +/b6 +/c6 +, and a7 +/b7 +/c7 +. Were these spectra an instance of de novo sequencing however, these four patterns of mass peaks, all of whose m/z-differences in order of increasing m/z are, respectively, of 28 and 17, could be interrogated by an appropriately designed computer algorithm to determine whether they did indeed correspond to N-terminal fragments.

The high-energy EID product-ion spectrum of doubly protonated ACTH (Figure 3a) is dominated by a mass peak corresponding to the triply charged, doubly protonated radical cation ([M + 2H]3+•, m/z = 560.6) formed via electron ionization of the [M + 2H]2+ precursor (m/z 837.0). It has been previously noted that the oxidized species is often present in high-energy EID spectra at a high abundance relative to backbone cleavage ions and, further, that this feature can be used to determine the oxidation threshold (essentially the ionization energy) of ions [19]. Signals corresponding to losses of CO2 (44.0 Da) from the doubly protonated precursor ([M + 2H]2+–CO2, m/z 818.9) and its ionized analogue ([M + 2H]3+•– CO2, m/z 545.9) are also prominent in the spectrum. It should be noted that the resolving power of the Agilent triple quadrupole is too low to allow the loss of CO2 (43.98984 Da) to be distinguished from possible losses of CN2H3 (43.02963 Da) or CONH2 (44.01364 Da) in peptides that can lose these moieties; this caveat should be borne in mind in the subsequent text when the appearance of a mass peak is attributed to a loss of CO2. Mass peaks putatively corresponding to SC losses (reaction 7, Table 1) from tryptophan ([M + 2H]2+– Wsc (129.1 Da), m/z 776.4), [M + 2H]3+• – Wsc (129.1 Da), m/z 517.6), arginine ([M + 2H]3+•– Rsc (99.1 Da), m/z 527.6), and methionine ([M + 2H]3+•– Msc (74.0 Da), m/z 535.9) are readily discerned in the ACTH spectrum. Finally, weak signals corresponding to four singly charged c- and z-type fragments and the charge reduced molecular ion [M + 2H]+• originating from ECD of the doubly protonated precursor are also assignable in the ACTH high-energy EID product-ion spectrum.

Figure 3
figure 3

High-energy EMS QqQ EID product-ion mass spectra of (a) ACTH and (b) neurotensin; insert shows speculative assignments of SC losses based on FT-ICR mass spectra reported by Kalli and Hess [15]. In both panels the EID precursor is the even electron species [M + 2H]2+; fragmentation also proceeds from the hydrogen-abundant reduced radical cations [M + 2H]+• and the hydrogen-deficient oxidized radical cations [M + 2H]3+•

Enyenihi [19] has pointed out that the neutral losses of amino acid SCs from the oxidized species observed in high-energy EID product-ion spectra (reaction 7, Table 1) can in principle be exploited in the same way immonium ions are to establish the presence of specific amino acids. In order to take full advantage of this possibility, more extensive fragmentation than observed in this study would be desirable. In the cases of ECD and electron-transfer dissociation (ETD), this has been accomplished, respectively, by collisional [29] or infrared-photon [3033] activation of the precursor population prior to or during electron capture and by collisional [34] or infrared-photon [35, 36] activation prior to or during electron transfer. There are two possibilities by which these techniques could be adapted to the EMS cell. Rather than operating Q2 in a transmission only mode (Figure 1a), Q2 can be operated in a CID mode (Figure 1b), as has been done previously [23, 27], so that collisional energy can be imparted to various high-energy EID species that require additional internal energy to dissociate. Alternatively, Q2 could be placed in front of the EMS cell (Figure 1c). Flipping the order of the cells in this manner would make it possible to collisionally activate (not to dissociation level) the protonated precursors in the CID cell before subjecting them to electron ionization in the EMS cell. Preparation to modify the QqQ and carry out the ion-activated high-energy EID experiment just described is currently in progress.

As in the case of ACTH, the most intense mass peak in the high-energy EID product-ion spectrum of doubly protonated neurotensin corresponds to the triply charged, doubly protonated radical cation ([M + 2H]3+• at m/z = 558.0, Figure 3b). Other mass peaks in the neurotensin spectrum whose identities can be assigned are consistent with losses of CO2 from the doubly protonated precursor ([M + 2H]2+ – CO2, m/z 815.0) and its ionized analogue ([M + 2H]3+•– CO2, m/z 543.3), neutral loss of a tyrosine SC from the doubly protonated precursor ([M + 2H]2+ – Ysc (106.0 Da), m/z 784.0), and a series of low abundance c- and z-type fragments, which have previously been produced by ECD of the doubly protonated precursor in both FT-ICR [37] and EMS [24] cells.

The appearance of a series of low intensity satellite peaks (insert, Figure 3b) at slightly lower m/z ratios than that of the triply charged radical cation suggests SC losses similar to those observed in the ACTH spectrum (Figure 3a). Although Kali and Hess [15] produced triply charged radical cations of neurotensin by a different process, the main products they identified from electron-induced dissociation of neurotensin’s triply charged radical cations by FT-ICR mass spectrometry were SC losses from leucine/isoleucine, glutamic acid, arginine, tyrosine, lysine, and combinations thereof. Hence, the weak signals nominally discerned at m/z 539, 538, 534, 529, 523, 515, and 506 in the EMS cell’s high-energy EID spectrum (insert, Figure 3b) might reasonably correspond to the following SC losses, respectively, from these same four residues: [M + 2H]3+• – Lsc (56.1 Da), m/z 539.3; [M + 2H]3+• – Esc (59.0 Da), m/z 538.3; [M + 2H]3+• – Esc (72.0 Da), m/z 534.0; [M + 2H]3+• – Rsc (72.1 Da), m/z 533.9; [M + 2H]3+• – Rsc (86.1 Da), m/z 529.3; [M + 2H]3+• – Ysc (106.0 Da), m/z 522.6; [M + 2H]3+• – Esc (59.0 Da) – Isc/Lsc (56.1 Da), m/z 515.3; and [M + 2H]3+• – Rsc (86.1 Da) – Ksc (71.1 Da), m/z 505.6. The weakness of the signals coupled with the Agilent 6460’s limited resolving power preclude, however, assignments to them as any other than speculative. The putative loss of CO2 from neurotensin’s triply charged radical cation, which is clearly evident in the EMS cell’s high-energy EID spectrum (Figure 3a), was only observed by Kalli and Hess in their electron-induced dissociation spectrum of the same ion species [15] when accompanied by a SC loss from leucine.

The high-energy EID product-ion mass spectrum of doubly protonated tyrosine kinase peptide 3 (p1518 – Figure 4a) is similar in most respects to that of neurotensin, exhibiting a prominent mass peak corresponding to the triply charged radical cation ([M + 2H]3+•, m/z 505.9), mass peaks putatively corresponding to losses of CO2 from the doubly protonated precursor ([M + 2H]2+– CO2, m/z 737.9) and its ionized analogue ([M + 2H]3+• – CO2, m/z 491.9), and a mass peak corresponding the neutral loss of a single, amino-acid SC from the precursor, in this case, most probably arginine ([M + 2H]3+• – Rsc (99.1), m/z 710.4) and the ionized precursor ([M + 2H]3+•– Rsc (99.1), m/z 473.6). A series of mass peaks corresponding to ECD c-type fragments, which was recently reported for this peptide [25], is also present in the spectrum.

Figure 4
figure 4

High-energy EMS QqQ EID product-ion mass spectra of (a) tyrosine kinase peptide 3 (p1518) and (b) phosphorylated tyrosine kinase peptide 3 (Pp1598). In both panels the EID precursor is the even electron species [M + 2H]2+; fragmentation also proceeds from the hydrogen-abundant reduced radical cations [M + 2H]+• and the hydrogen-deficient oxidized radical cations [M + 2H]3+•

The doubly protonated, phosphorylated analogue of tyrosine kinase peptide 3 (Pp1598) yielded a high-energy EID product-ion mass spectrum (Figure 4b) that, except for the obvious 80-Da shift of all peaks, is very similar to that of p1518 (Figure 4a). Specifically, the spectrum displays a very strong signal consistent with the ionized precursor ([M + 2H]3+•, m/z 532.6), prominent signals consistent with the loss of CO2 from both the precursor and the ionized precursor (respectively, [M + 2H]2+– CO2, m/z 777.9; [M + 2H]3+• – CO2, m/z 518.6), a structurally related fragment consistent with the loss of an arginine SC from both the precursor and the ionized precursor (respectively, [M + 2H]3+• – Rsc (99.1), m/z 750.4); [M + 2H]3+• – Rsc (99.1), m/z 500.2), and a series of ECD c-type fragments. In addition, there are significant mass peaks in Pp1598’s high-energy EID product-ion spectrum nominally at m/z 485, 714, and 735 that could possibly correspond to combinations of SC losses from arginine, aspartic acid, and glutamic acid such as [M + 2H]3+• – Rsc (86.1 Da) – Dsc (58.0 Da), m/z 485.2; [M + 2H]3+• – Rsc (99.1 Da) – Esc (72.0 Da), m/z 714.4; and [M + 2H]3+• – Rsc (72.1 Da) – Dsc (58.0 Da), m/z 734.9. The most significant aspect of this high-energy EID spectrum, however, is the absence of fragments corresponding to the loss of tyrosine’s phosphorylated SC either from the even electron precursor ions, the reduced radical cations, or the oxidized radical cations. This observation agrees with that made earlier by Enyenihi [19], namely, that high-energy EID product-ion spectra still allow for confident identification of phosphorylated residues.

Conclusion

Fragmentation techniques involving electron-ion reactions with electron energies sufficient to produce electronic excitation are highly informative in FT-ICR mass spectrometry [3841]. Dissociation of protonated peptides irradiated with electrons whose energies range from near 0 to >30 eV proceeds from electronically excited even electron precursor ions, reduced radical cations formed by capture of low-energy electrons, and oxidized radical cations produced by interaction with high-energy electrons [12, 19]. Consequently, as has been shown by various research groups [12, 1520], EID in this energy regime can give rise to higher sequence coverage than is typically observed in peptide product-ion spectra produced by a single dissociation process while retaining information about post-translational modification. The results of this study demonstrate that an ECD EMS cell installed in a QqQ mass spectrometer can be used to produce high-energy EID product-ion spectra that, within the limits of the QqQ’s resolving power, exhibit essentially the same qualitative structural information (i.e., amino acid SC losses and backbone cleavages) as observed in high-energy EID spectra produced with an FT-ICR mass spectrometer. In as much as the triply charged radical of Substance P has been identified in an high-energy EID spectrum recorded at a resolving power of ~13,500 (m/z 674) with a QqTOF mass spectrometer in which an EMS ECD cell was installed [27], it is reasonable to expect that the preceding conclusion extends to an EMS ECD cell installed in a QqTOF mass spectrometer with the added benefit of that platform’s greater resolving power.

The levels of fragmentation efficiency evident in the product-ion spectra recorded in this study as well as in those recorded in earlier studies with FT ICR mass spectrometers [12, 1520] is at the margin of analytical utility. Efforts by the present authors are underway to eliminate this shortcoming in the EMS cell. Assuming this is accomplished, EMS cells incorporated into QqQ or QqTOF mass spectrometers would make tandem high-energy EID mass spectrometry more widely accessible for analyses of peptides and small, singly charged molecules like pharmaceuticals [4245]. Q[EMS]qQ platforms would make possible targeted multiple reaction monitoring (MRM) of peptides based on EID transitions or combined EID/CID transitions, a capability that could have widespread applicability in pharmaceutical and clinical analyses. Q[EMS]qTOF platforms would make it easier for research groups to exploit high-energy EID in identification and de novo sequencing of peptides, and the prospect of performing ion-activated high-energy EID on QqTOF instruments further suggests the possibility of wider application of top-down analyses of folded gas-phase proteins. Recently, the present authors have recorded HPLC tandem mass spectra of peptide mixtures and a tryptic protein digest and performed MRM analyses of those samples based on ECD transitions with the EMS QqQ system described in this report [26]. By reasonable extension, it should thus also be possible to perform tandem mass spectrometry in conjunction with high-energy EID on the time-scale of liquid chromatography, which in turn would increase the amount of complementary information producible by a single instrument from analyses of proteins, peptides, and small molecules such as those of interest to the pharmaceutical industry.