Introduction

Advanced coronary artery disease often requires surgical bypass using autologous vessels to reestablish adequate blood flow to the heart. Despite new surgical techniques, materials, and interventional criteria that have improved overall patency, the 1st-year failure rates for coronary artery bypass grafting (CABG) remain between 5 and 15% and are strongly dependent upon the source tissue.16, 17, 34 Vein grafts, for example, suffer from progressive intimal-medial hyperplasia with only a 65% 5-year patency rate.30 Although the etiology of vein-graft disease is multifactorial, due partly to their mechanical composition and microstructure, it has been hypothesized that veins exposed to altered hemodynamic loading induce endothelial cell damage, thrombosis, and fibrosis.10, 11 Concurrent with this is the concept of structural mechanical mismatching (compliance mismatching) at the anastomotic junction—a location of vulnerability in the grafting process5, 17, 22, 46—which is a consequence of both geometrical and mechanical differences between the host and graft tissues.6, 16, 22, 44 The sudden change in deformed vessel geometry across the anastomotic junction can also cause atherogenic flow disturbances around contraction and expansion points12, 13, 18 triggering endothelial conformational and functional changes.1, 8 Likewise, mechanosensitive mural cells that guide regulatory, remodeling, and migratory pathways, may experience altered wall stresses near the anastomotic junction and exhibit an unfavorable cellular response.19, 24, 33 Overall, graft-host mechanical and geometric mismatching present a major risk of graft failure and restenosis.7, 9

Arteries, especially the internal thoracic artery (ITA), have been used successfully in bypass grafting; thus, the pathology of artery graft failure has received less attention than veins. The left (LITA) and right (RITA), for example, possess abundant histomechanical similarities to the left anterior descending artery (LAD), supporting its continued use as the superior autograft option.15, 17, 20, 34 Moreover, the single anastomotic junction and native hemodynamic similarity improve overall patency. Our recent investigation revealed that the ITA exhibits multiple histological patterns depending on the distance from the heart (i.e., elastic, hybrid, muscular), and can be divided into four distinct anatomical grafting regions (1 = proximal, 2 = submuscular, 3 = middle, 4 = distal).15, 26, 29, 42 Likewise, coronary arteries and their branches possess distinct regional variations in geometry and microstructure that can change with sex, age, species, and disease conditions.25, 43

In this study, we quantified the properties of four different coronary artery targets, namely the proximal and distal left anterior descending (PLAD & DLAD), right coronary artery (RCA), and left circumflex artery (LCX), using the American Yorkshire pig as a surrogate for the human central vasculature. Histomechanical results were directly compared to those of the middle LITA segment (LITA3) to serve as a representative sample of ITA architecture.21, 38 Biaxial mechanical data was used to estimate constitutive modeling parameters using a nonlinear, hyperplastic, structurally motivated material model within a continuum mechanics framework. Leveraging these data, idealized computational models of end-to-end anastomoses with 32 different graft-target (ITA-coronary) combinations were constructed.26 Finite Element Analyses (FEA) were first used to simulate and perform a “virtual anastomosis” through alignment of the vessel’s lumens and attachment of the two tissues. Finally, the resultant deformed geometry was fed into a Computational Fluid Dynamics (CFD) simulation to model fluid-flow behavior. Although end-to-end anastomosis is not the preferred surgical configuration, computational models were designed to mimic ongoing mechanobiological laboratory experiments and provide an initial indication of source tissue performance. Given that the bypass region (e.g., PLAD, DLAD, RCA, LCX) is dictated by the clinically determined stenosis location, a normalized objective function, based on mechanical deviation from homeostatic stresses, was found for each graft-coronary combination so that the preferred ITA region could be selected for each coronary target.

Materials and Methods

Tissue Acquisition

Porcine coronary arteries and ITAs were acquired from 2-year-old American Yorkshire sows from a local abattoir weighing approximately 200 kg. All arteries were dissected under sterile conditions within 1 h of slaughter and transported in 1% phosphate-buffered saline (PBS) with heparin sodium (20 units/mL), cleaned, and separated into different groups for histological and mechanical characterization (Fig. 1). The four coronary arteries included the proximal and distal left anterior descending artery (PLAD & DLAD), right coronary artery (RCA), and left circumflex artery (LCX). Where applicable, and for simplicity purposes, the discrete histological (n = 5, each) and mechanical data (n = 4, each) were averaged for each group of coronary arteries. These averaged values were compared to the average histological (n = 4) and mechanical (n = 5) values of the third segment of the left ITA (LITA) excised from the same pigs. Our previous work revealed this segment had the fewest notable differences from other segments of the left or right ITA.26

Figure 1
figure 1

Porcine heart from the anterior and superior view with distinct structures labeled to discern relative sizes and locations of the four coronary arteries of interest. PLAD proximal left anterior descending artery; DLAD distal left anterior descending artery; LCX left circumflex artery; RCA right coronary artery; RA right atrium; LA left atrium; PV pulmonary vein.

Biaxial Mechanical Testing

All testing was performed on fresh arteries and completed within 48 h of animal sacrifice. Before performing acute biaxial mechanical testing on our Bose BioDynamic biaxial mechanical testing device, the region of each coronary artery to be tested underwent a rigorous selection process to ensure accurate and reproducible results. The region that exhibited the least amount of twisting or bending was selected for biaxial testing with an average undeformed length of ~ 9.88 mm and an angle of ≥ 164° (straight = 180°) for all coronary arteries. These vessels were mounted onto two Luer fittings and fixed in place by tying several 3–0 braided sutures around the ends. An initial measurement of the unloaded length was recorded as the distance between sutures, which aided in calculating experimental axial stretch ratios. The tissue samples were submerged in the testing bath and perfused with 1% PBS and sodium nitroprusside (10–5 M) to elicit a fully passivated state. Vessels were inflated to pre-defined pressures by increasing the volumetric flow rate and the downstream resistance, per the design of the testing device. Every sample underwent five cycles of axial extension and inflation preconditioning to minimize viscous dissipation and ensure reproducible results. Inflation-extension testing was then conducted at 0–200 mmHg and at three axial stretch ratios, the in vivo stretch, and ± 10%. The in vivo axial stretch ratio was the axial extension which yielded a constant force measurement during changes in pressure. The luminal pressure and axial displacement were both controlled while the deformed outer radius and axial force were recorded.

Following biaxial mechanical testing, a 1 mm thick ring segment was cut from the middle of the vessel, and a cross-sectional image was captured. The residual strain in the vessel was removed by making a radial cut and allowing the tissue to equilibrate for 30 min in 1% PBS. An image of this zero-stress state was captured using a Canon EOS 60d DSLR camera mounted to a dissecting microscope using an adapter lens (Micro Tech Lab). ImageJ image analysis software (NIH) was used to measure the geometries of both images. The unloaded thickness and opening angle were calculated from

$$H = \frac{2A}{{L_{i} + L_{o} }}$$
(1)

and

$$ {\varPhi} = \pi - \frac{{L_{o} - L_{i} }}{\mathrm{2}\it{H}},$$
(2)

where Li and Lo are the inner and outer arc lengths, respectively, and A the cross-sectional area. Under the assumption of incompressibility, the inner radius at any deformed state could be calculated as

$$r_{i} = \sqrt {r_{o}^{2} - \frac{A}{{\pi \lambda_{z} }}} ,$$
(3)

where \(\lambda_{z}\) is the axial stretch ratio. The mid-wall circumferential and axial stretches can be calculated from

$$\lambda_{\theta } = \frac{{2\pi \left( {r_{i} + r_{o} } \right)}}{{L_{i} + L_{o} }},$$
(4)
$$\lambda_{z} = \frac{l}{L},$$
(5)

where l and L are the deformed and undeformed lengths, respectively. Then the mean circumferential stress, mean axial stress, and area compliance are calculated from

$$\it \sigma_{\theta } = \frac{{Pr_{i} }}{h},$$
(6)
$$\sigma_{z} = \frac{F}{{\pi \left( {r_{o}^{2} - r_{i}^{2} } \right)}},$$
(7)
$$C_{A} = \pi \frac{{\Delta r_{i}^{2} }}{\Delta P},$$
(8)

where \(F\) is the axial force, \(P\) the transmural pressure, and \(h\) the wall thickness. For area compliance, \(\Delta r_{i}^{2}\) is the change in inner radius squared (area) per change in pressure \(\Delta P\) calculated around a 100 ± 20 mmHg operating point.

Constitutive Modeling of Experimental Data

The constitutive modeling framework was identical to our previous investigation with extended details and procedures found therein.26 Briefly, we used a modified version of the structurally-motivated constitutive model proposed by Holzapfel, Gasser, and Ogden to include the four families of collagen fibers4, 23 to represent each coronary artery uniquely, so that

$$W\left( {{\mathbf{C}},{\mathbf{M}}^{k} } \right) = \frac{c}{2}\left( {I_{C} - 3} \right) + \sum\limits_{k = 1}^{4} {\frac{{c_{1}^{k} }}{{4c_{2}^{k} }}\left\{ {\exp \left[ {c_{2}^{k} \left( {IV_{C}^{k} - 1} \right)^{2} } \right] - 1} \right\}} ,$$
(9)

where \(I_{C} = tr({\mathbf{C}})\) and \(IV_{C}^{k} = {\mathbf{M}}^{k} \cdot {\mathbf{CM}}^{k}\) are the first and fourth principal invariants, respectively of the right Cauchy–Green deformation tensor, \({\mathbf{C}}\). \({\mathbf{M}}^{k} = [0,\,\,\sin (\alpha^{k} ),\,\,\cos (\alpha^{k} )]\) is a unit vector oriented in the direction of the \(k{\text{th}}\) fiber at an angle \(\alpha^{k}\) relative to the axial direction with \(\alpha^{1} = 0\), \(\alpha^{2} = {\pi \mathord{\left/ {\vphantom {\pi 2}} \right. \kern-0pt} 2}\), and \(\alpha^{3} = - \alpha^{4}\). Assuming relatively small radial stresses, the problem is reduced to plane stress and the theoretical pressure and force calculated from

$$P^{\prime} = \frac{h}{{r_{i} }}\left[ {\lambda_{\theta } \frac{\partial W}{{\partial \lambda_{\theta } }} - \lambda_{r} \frac{\partial W}{{\partial \lambda_{r} }}} \right],$$
(10)
$$F^{\prime} = \pi h\left( {2r_{i} + h} \right)\left[ {2\lambda_{z} \frac{\partial W}{{\partial \lambda_{z} }} - \lambda_{r } \frac{\partial W}{{\partial \lambda_{r } }}} \right].$$
(11)

The eight-independent positive modeling parameters were then found by least-squares minimization of an objective function between the experimentally measured [Eqs. (6)–(8)] and theoretically modeled [Eqs. (10)–(11)] values of pressure and force using MATLAB's optimization toolbox (MathWorks; Natick, MA).

Computational Modeling

To simulate outputs from both the solid and fluid domains, computational models of each possible grafting configuration were generated for all 32 coronary-ITA combinations in FEBio.27 The experimentally determined material properties were represented using the available constitutive model for a solid mixture of anisotropic four fiber families embedded in an isotropic ground matrix. In all cases, the ITA’s unloaded inner diameter was greater than the coronary artery so the lumens were first matched by applying an equal but opposite direction pressure to the inner surface elements at the ends of the respective vessels until a continuous lumen was formed. Then a tied facet-on-facet contact was enforced between the two arteries to serve as a “virtual anastomosis” with approximated geometry. A fixed displacement boundary condition for the z-direction was applied to the non-anastomosed ends of both the graft and coronary arteries. For simplicity, the virtually anastomosed tissues were studied under a single quasi-static inflation pressure of 100 mmHg. Thus, the previous step’s stress history was not carried to the final simulation. The magnitude of the first principal stress (σ1—maximum normal stress in a plane oriented to be absent of shear) for each anastomosis was found and plotted vs. location along the graft-coronary axis. The displacement tolerance, energy tolerance, and line search tolerance for this solid mechanical FEA model were set to 0.001, 0.01, and 0.9, respectively. The simulation results were deemed mesh-independent if mesh refinement led to less than a 0.5% change in the average first principal stress.2 A total of 7680 hexahedral (hex8) elements were required for mesh independence.

The inflated lumen mesh at 100 mmHg was extracted to build a computational fluid dynamics (CFD) model to simulate steady and fully developed blood flow through the anastomosis consisting of a 10 mm long segment of the ITA graft on the proximal side and a 10 mm segment of the coronary artery on the distal side. Blood was modeled as an incompressible non-Newtonian Carreau fluid (η0 = 0.25 Pa s; η = 0.0035 Pa s; λb = 25; n = 0.25) with a fluid density of 1060 kg/m3 and zero-slip fluid boundary conditions applied to the outer surface of the extracted geometry representing the interface between the blood and the arterial wall.3, 28 Additionally, a zero fluid dilation boundary condition was applied to the inlet and outlet surfaces. Because direct blood flow measurements were not feasible with abattoir-sourced pigs, published coronary blood flow data from young, healthy domestic swine were used to calculate the volumetric flow of each coronary artery using allometric scaling laws.32 For simplicity, analyses were performed under steady flow conditions, so the effects of the fluid–solid interface and vessel wall motion were not analyzed. The tissues were then used to predict regional maximum fluid shear stress (τw—wall stress due to fluid friction acting opposite to the direction of blood flow) across the anastomoses in the in vivo-like loaded condition. The fluid velocity tolerance, fluid dilatation tolerance, and energy tolerance within the CFD model were set to 0.001, 0.001, and 0.01, respectively. CFD simulation outputs were deemed mesh-independent if additional mesh refinement led to less than a 0.5% change in the average fluid shear stress.2 A total of 155,159 tetrahedral (tet4) elements were required to reach mesh independence.

Since blood vessels have a preferred homeostatic or “basal” state of stress,24, 33 the maximum σ1 values from the solid mechanical model were normalized to basal coronary σ1 values taken from biaxial mechanical data captured at the force-invariant axial stretch and 100 mmHg. Likewise, the maximum τw values from the fluid dynamic model were normalized to basal τw values. The basal coronary stresses were given a value of 0, and the maximum stresses from each model were given a value of 1 to scale the anastomosis configurations in terms of the most significant deviation from basal coronary stresses (GraphPad Prism).

Histological Analysis

Fresh arteries were fixed in 4% paraformaldehyde and embedded in paraffin wax. Sections were cut at 5 μm and stained with Movat’s Pentachrome or Picrosirius Red (PSR). Tissue segments from the same heart were processed together to facilitate a uniform histological comparison. Brightfield images were then obtained using a Nikon E600 microscope and computer interface with Q Capture (QImaging). The PSR stained sections were imaged through brightfield microscopy and cross-polarized light using a Zeiss AxioCam MCr5. Each arterial cross-section was imaged around the vessel’s circumference at five different locations.

Constituent area fractions were obtained using ImageJ software with the “Threshold_Colour” plugin. Movat’s Pentachrome stained sections were used to estimate area fractions of elastin and smooth muscle cells (SMCs). On the other hand, the area fraction of collagen was found as the ratio of PSR cross-polarization birefringence to the total tissue measured in the brightfield. The standard threshold values were fixed at specified brightness, saturation, and hue ranges to ensure experimental consistency. Elastin was stained deep red/brown and was quantified using a bandpass filter from brightness 34–155 and saturation 60–255, and a band stop filter from hue 4–130. SMCs were stained red/pink and were quantified using a bandpass filter from brightness 135–220, saturation 90–185, and hue 0–11. The sums of these areas were normalized to 1 for each sample. Cross-polarized light analysis of collagen birefringence was quantified separately for the medial and total cross-sectional areas. The medial region of interest (ROI) was confined to the inner and outer elastic lamellae area. The total birefringence signal was measured using a bandpass filter from brightness 30–255, saturation 0–255, and hue 0–255.

Statistical Analyses

Experimental data were analyzed using GraphPad Prism to identify the statistical significance of discrete metrics of LITA and the coronary vasculature. Comparisons of the mechanical properties were conducted through a one-way ANOVA with a two-tailed paired t-test of unequal variances. The histological data were analyzed through a two-way ANOVA in conjunction with two-tailed paired t-tests of unequal variances to determine statistical differences between the amounts of load-bearing constituents found within the arterial samples. Statistically significant differences were taken at confidence levels of p < 0.05, p < 0.01, and p < 0.001.

Results

Plots are displayed for all coronary arteries at their respective force-invariant stretch (middle) as well as ± 10% stretch (low, high) (Fig. 2). The axial force-pressure profiles revealed that the force-invariant stretch for the DLAD was the only artery that maintained a force reading above 0.5 N for the entire experimental pressure range. The pressure-outer diameter profiles exhibited some of the expected variability commonly observed when using abattoir tissue samples. However, the circumferential stress and stretch measurements had comparatively smaller error bars due to their calculation’s dependency on each specimen’s cross-sectional area or unloaded radius, respectively. From this data, the structurally-motivated constitutive model revealed a set of best-fit parameters that demonstrated an excellent fit to grouped experimental data (Table 1) with an average root mean square error (RMSE) of 0.2405 across all coronary arteries. Since the reported parameters are fitted for the grouped data, rather than fitted for an individual sample and then averaged, values are reported without standard deviation and no statistical comparisons are made. Nevertheless, we note that the isotropic parameter \(c\) was highest for the PLAD and lowest for the RCA making up 48.9 and 10.2%, respectively, of the total elastic energy when assessed at in vivo-like stretch conditions. Likewise, the paired contribution of the anisotropic parameters, \(c_{1}\) and \(c_{2}\), to the total strain energy for the DLAD is much higher in the axial (superscript 1, 41.6% of the total) than in the circumferential direction (superscript 2, 10.8% of the total) when assessed at in vivo conditions. By comparison, the axial and circumferential contributions to the total strain energy of the LCX were 17.9 and 16.9%, respectively.

Figure 2
figure 2

Biaxial mechanical data of the four porcine coronary arteries (n = 4, each). The leftmost plots are pressure–outer diameter data, the center plots are axial force–pressure data, and the rightmost plots are mean circumferential stress–mid-wall circumferential stretch data. Data was collected at three distinct stretch ratios, the force-invariant stretch (middle) as well as ± 10% strain (low, high). Mean ± SEM.

Table 1 Fitted material parameters for grouped coronary artery datasets used in this study.

Data captured from the stress-free configurations revealed that LITA has significant geometric differences from the coronary arteries (Table 2). The LITA outer arc length was significantly larger than the PLAD (p = 0.039), DLAD (p < 0.001), RCA (p = 0.001), and LCX (p < 0.001), while the LITA opening angle was significantly smaller than the PLAD (p = 0.003), DLAD (p = 0.021), RCA (p = 0.005), and LCX (p = 0.004). Comparing mechanical data at common loading conditions (i.e., 100 mmHg, force-invariant axial stretch) revealed that LITA has a significantly larger loaded inner radius than DLAD (p = 0.010), RCA (p = 0.029), and LCX (p = 0.014) (Fig. 3a). Similarly, LITA exhibited significantly larger area compliance (p < 0.001) and circumferential stress (p ≤ 0.005) than all coronary arteries (Figs. 3b and 3c, respectively).

Table 2 Averaged unloaded geometries for each group of (n = 4) arteries.
Figure 3
figure 3

Biaxial mechanical data of the porcine coronary arteries and the third LITA segment plotted at common loading conditions of 100 mmHg and the force-invariant stretch (n = 4, each). (a) Inner radius; (b) area compliance; (c) circumferential stress; (d) axial stress. Statistical significance between different coronary arteries is indicated by (**) and (***) at p < 0.01 and p < 0.001, respectively. Statistical significance between a coronary artery and LITA is indicated by (#) at p < 0.05. Mean ± SD.

Image thresholding using Movat’s Pentachrome stain revealed that the amount of elastin found within the LITA segment was significantly greater than that of all coronary arteries; PLAD (p < 0.001), DLAD (p < 0.001), RCA (0.28 ± 0.04, p < 0.001), and LCX (p < 0.001) (Fig. 4f). Inversely, the area fraction of smooth muscle cells within LITA was significantly less than that of all coronary arteries; PLAD (p < 0.001), DLAD (p < 0.001), RCA (p < 0.001), and LCX (p < 0.001) (Fig. 4F). The adventitial collagen area fraction of the LITA was significantly less than that of all coronary arteries (p < 0.001) (Fig. 5f).

Figure 4
figure 4

Qualitative and quantitative comparison of arterial wall composition using Movat’s Pentachrome stained cross-sections. (a) PLAD; (b) DLAD; (c) RCA; (d) LCX; and (e) the third LITA segment. (f) Quantified area fractions of elastin and smooth muscle cell dyes for all arterial sections (n = 5, each). Statistical significance between a coronary vessel and LITA is denoted as (#) at p < 0.05. Mean ± SD.

Figure 5
figure 5

Picrosirius red-stained cross-sections imaged through polarized light microscopy. (a) PLAD; (b) DLAD; (c) RCA; (d) LCX; and (e) the third LITA segment. (f) Quantified area fractions of medial and adventitial collagen birefringence (n = 5, each). Statistical significance between the adventitial collagen of a coronary vessel and LITA is denoted as (#) at p < 0.05. Mean ± SD.

Interestingly, comparisons of the mechanical properties between the coronary vessels revealed few differences. Notably, the circumferential stress of the PLAD was significantly greater than that of RCA (p < 0.005), while the DLAD experienced a significantly higher axial stress than the PLAD (p = 0.001), RCA (p = 0.003), and LCX (p < 0.001) (Figs. 3c and 3d). There were no significant histological differences found between any of the coronary vessels.

All tapering simulations converged except the RCA-RITA1, which was omitted from the results. As a representative example, colorimetric FEA model illustrations of σ1 and τw for the PLAD-LITA3 combination are shown in Figs. 6a and 6b, respectively. The spatial plots of σ1 across the anastomotic junction for all configurations are shown in Fig. 7; likewise, τw is displayed in Fig. 8. Maximum stresses for each simulation (i.e., the peak values of each curve in Figs. 7 and 8) are collated and reported in Table 3. The ITA graft segment that yielded the maximum and minimum stress values for each coronary vessel are highlighted in red and blue, respectively. Notably, for the PLAD, RCA, and LCX, the maximum σ1 occurred when anastomosed with the LITA1, while the DLAD, on the other hand, was highest when anastomosed to the LITA4. Likewise, for PLAD, DLAD, and LCX, the maximum τw occurred when anastomosed with LITA4, while RCA maximum occurred when connected with RITA4. Finally, the solid and fluid simulation outputs were normalized and averaged to create an objective function relative to the basal coronary stress values. Table 4 shows normalized values for each coronary artery in red and blue, respectively, inferring the greatest and smallest degree of deviation from the basal coronary stresses. This table reveals that the poorest overall grafting options largely follow the trends set by the first principal stress in Table 3 (LITA1 for all except for the DLAD). The best grafting options for the LADs are LITA2 while the best grafting options for the RCA and LCX are RITA3 and LITA4.

Figure 6
figure 6

Computational analysis of PLAD-LITA3 end-to-end anastomosis. (a) Colorimetric illustration of first principal stress (σ1) after inflation from 0 to 100 mmHg. (b) Colorimetric illustration of fluid shear stress (τw) at the inflated configuration. Red arrows depict the contact region representing the anastomosis.

Figure 7
figure 7

Plots of the first principal stress (σ1) along the anastomosis for all ITA-coronary combinations. (a) ITAx-PLAD, (b) ITAx-DLAD, (c) ITAx-RCA, and (d) ITAx-LCX where x represents the respective ITA region. The vertical line represents the anastomotic junction between the two vessels.

Figure 8
figure 8

Plots of the maximum fluid shear stress (τw) along the anastomosis for all ITA-coronary combinations. (a) ITAx-PLAD, (b) ITAx-DLAD, (c) ITAx-RCA, and (d) ITAx-LCX where x represents the respective ITA region. The vertical line represents the anastomotic junction between the two vessels.

Table 3 Summary of peak simulation outputs from the solid–fluid models of all anastomosis configurations.
Table 4 Results of the normalized objective function for all anastomosis combinations.

Discussion

Anisodiametric and anisocompliant graft-target tissue combinations have been correlated to increased restenosis rates and premature graft failure.7, 17, 46 Since the joining of distinctly different anisotropic tissues creates nonlinearities at the interface with resultant geometries that are not easily solved using standard analytical approaches, we present a histomechanical and computationally-driven objective function to assess the biomechanical responses of the different ITA grafting regions for a given coronary target. Our study provides insight into the inherent differences between these tissues and illustrates the solid mechanical and fluid dynamic consequences that arise in an end-to-end CABG anastomosis configuration.

Not surprisingly, our computational analyses revealed the mechanical response across the anastomotic junction was unique for each ITA-coronary graft combination. Even though our simplified approach uses sutureless and idealized end-to-end anastomoses, the interface still experiences high-stress concentrations due to the abrupt change in geometry and material properties. Moreover, our simulations show the peak stress values occur predominantly on the coronary side of the anastomotic junction, a finding supported by the literature that depicts the suture line as a vulnerable site for the development of intimal hyperplasia in response to mechanical mismatch with the graft.6, 31 This evidence supports normalizing our solid mechanical simulation outputs to the basal levels of coronary stresses rather than those of the graft tissue. For vein grafts, intimal-medial thickening occurs within the graft tissue itself.10, 30 However, when these vein grafts were analyzed spatially, 67% developed fibro-intimal thickening, and 33% had an atherosclerotic plaque on the proximal (aortic) side, while 96% showed fibro-intimal thickening and only 4% had an atherosclerotic plaque on the distal (coronary) side.47 Indeed, several factors play a role in the etiology of regional graft failure, but compatibility with the anastomosing tissue is likely paramount to this process. Still, more attention needs to be given to the spatial pathology of arterio-graft disease.

Our finite element results provide a framework for optimal graft selection based on the minimization of an objective function for all graft vessels. Most of the coronary arteries matched poorest with the LITA1 except for the DLAD. Interestingly, the DLAD exhibited the greatest axially-biased anisotropy as indicated by the pairwise contribution of axial parameters \(c_{1}^{1}\) and \(c_{2}^{1}\) to the total strain energy. In contrast, the PLAD had the greatest isotropic contributions to the total strain energy (parameter \(c\), Table 1) and most potential ITA graft vessels matched extremely well with this coronary artery. Although experimental and computational tools of biomechanical analyses (i.e., how biological bodies respond to applied forces or displacements) were used in this study to predict localized stress gradients, the underlying motivation for our work was one of mechanobiology (i.e., how physical loads affect the biological output of cells). That said, the vascular wall cells are accustomed to basal levels or “homeostatic” stresses with chronic perturbations in loading, leading to a restoration of long-term stress.19, 24, 33, 45 Cellular and tissue level stresses are not zero with resident vascular cells exposed to healthy multi-directional periodic loading in vivo. Moreover, emerging evidence supports the idea that the cells of the graft tissue are gradually replaced by the host.36 For these reasons, basal values of homeostatic coronary vessel stresses were chosen as a baseline for normalization rather than values of the graft tissue. Likewise, regions of low-shear are known for atherosclerotic plaque localization and progression, but high-shear regions have also been linked to plaque progression/transformation, necrotic core progression, and increased apoptosis rates.14, 17, 39 Interestingly, the fluid and solid stress levels found from our computational analysis were an order of magnitude lower in the LAD than the RCA and LCX anastomoses and may be responsible, in part, for the enhanced pathological outcomes in this region.37 Still, further study into regional pathologies is needed to draw a more robust conclusion.

Our approach towards estimating constitutive parameters are based on the axisymmetric deformation of anisotropic cylindrical specimens experiencing elastic deformations under pressurization and longitudinal extension thus subjecting all specimens (ITA and coronary) to the same set of conditions. Although we chose the straightest regions of the coronary vasculature possible, Saravanan et al. showed that the porcine circumflex artery actually undergoes bending and twisting and that omission of these deformations adds uncertainty to the analysis.40 This observation may play a role in the disparate axial stress values displayed in Fig. 3d, but further analysis beyond the scope of the current work would be required. Overall, our analytical and computational approaches were indeed idealized. Likewise, end-to-end anastomoses are rarely implemented clinically. This configuration, however, demonstrates an axisymmetric stress field, permits clear comparisons of compliance mismatching, and enables direct interpretation of ongoing mechanobiologically-driven experimental assessments such as immunohistochemistry, ELISAs, qPCR, and Western blot analyses. An unfortunate disadvantage is that significant size discrepancies between the graft and host tissues limit potential configurations experimentally and computationally. For example, our tapered computational geometries and tied facet-on-facet contact restrictions could not be implemented for the RCA-RITA1 combination. End-to-side, spatulated, or even fish-mouth surgical techniques could be performed to circumvent such limitations.7, 35 These are important for translating the current work into clinical investigations and are part of our ongoing studies. Another notable limitation was the idealized nature of the virtual anastomotic junction. In addition, there was no stress history carried over from the virtual anastomosing process to elucidate local stress gradients that arise solely from intraluminal pressurization. As a common site for surgically-induced vascular injury, the exclusion of sutures or other surgical materials (e.g., vascular clips) from our models allowed for quantification of the solid mechanical and hemodynamic stress gradients that arise solely from the gross biomechanical differences between the graft and target tissues rather than the stress concentrations around sutures.6, 41, 44 In fact, suture compliance matching may be as important as tissue compliance matching.44

Conclusion

Using a porcine surrogate for the human central vasculature our experimental and computational analyses helped provide insight into the importance of graft tissue selection by quantifying the mechanical consequences of an idealized virtual coronary-grafting anastomosis. Based on an objective function used to stratify these tissue combinations for all converged solutions, we found the best ITA graft region for the RCA and LCX was RITA3, and LITA3, respectively, while the best grafting region for both PLAD and DLAD was the LITA2. Vice-versa, the worst ITA grafting region for the PLAD, RCA, and LCX was LITA1, while the worst region for the DLAD was LITA4. This information provides the foundational knowledge necessary for the ongoing investigations of matched and mismatched tissue combinations that will be used to establish a link between mechanobiologically-driven inflammation and thrombosis within mismatched graft-target tissues.