Abstract
Atherosclerosis develops due to different hemodynamic factors, among which time-averaged Wall shear stress (mean WSS) and Oscillatory shear index (OSI) are two of the most important. These two factors not only depend on flow geometry, but are also influenced by rheological characteristics of blood. Since analytical solutions are limited to simple problems and since experimental tests are costly and time consuming, CFD solutions been prominently and effectively used to solve such problems. We conducted a numerical study via ADINA 8.8 software on the non-Newtonian pulsatile flow of blood through an elastic blood artery with single and consecutive stenosis. The studied stenosis cross sectional area was 70 % that of the unstenosed artery. The single stenosis results were compared with the consecutive stenosis results. The five non-Newtonian flow models, the Carreau model, the Carreau-Yasuda model, the modified Casson model, the power-law model, and the generalized power-law model, were used to model the non-Newtonian blood flow. The obtained results showed that increasing the number of stenoses would lead to reduced length of the oscillatory area after the first stenosis, thus forming another oscillatory area with a larger length after the second stenosis. Thus, a consecutive stenosis would develop a larger disease prone area. Upon examining the mean WSS and OSI, we found that, as compared with the other models, the modified Casson model and the power-law model produced predictions for the most extent of damage to endothelial cells and the most disease prone areas, respectively.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
C. Zarins, D. Giddens, B. Bharadvaj, V. Sottiurai, R. Mabon and S. Glagov, Carotid bifurcation atherosclerosis. Quantitative correlation of plaque localization with flow velocity profiles and wall shear stress, Circ. Res., 53 (4) (1983) 502.
D. Ku, D. Giddens, C. Zarins and S. Glagov, Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress, Arterioscler. Thromb. Vasc. Biol., 5 (3) (1985) 293–302.
E. Pedersen, S. Oyre, M. Agerbaek, I. Kristensen, S. Ringgaard, P. Boesiger and W. Paaske, Distribution of early atherosclerotic lesions in the human abdominal aorta correlates with wall shear stresses measured in vivo, Eur. J. Vasc. Endovasc. Surg., 18 (4) (1999) 328–333.
M. Lei, D. Giddens, S. Jones, F. Loth and H. Bassiouny, Pulsatile flow in an end-to-side vascular graf tmodel: comparison of computations with experimental data, J. Biomech. Eng., 123 (2001) 80.
J. Soulis, G. Giannoglou, G. Parcharidis and G. Louridas, Flow parameters in normal left coronary artery tree. Implication to atherogenesis, Comput. Biol. Med., 37 (5) (2007) 628–636.
J. Soulis, G. Giannoglou, Y. Chatzizisis, K. Seralidou, G. Parcharidis and G. Louridas, Non-newtonian models for molecular viscosity and wall shear stress in a 3d reconstructed human left coronary artery, Med. Eng. Phys., 30 (1) (2008) 9–19.
J. R. Cebral, F. Mut, J. Weir and C. M. Putman, Association of hemodynamic characteristics and cerebral aneurysm rupture, Am. J. Neuroradiol., 32 (2011) 264–270.
G. Lu, L. Huang, X. L. Zhang, S. Z. Wang, Y. Hong, Z. Hu and D. Y. Geng, Influence of hemodynamic factors 356 on rupture of intracranial aneurysms: patient-specific 3D mirror aneurysms model 357 computational fluid dynamics simulation, Am. J. Neuroradiol., 32 (2011) 1255–1261.
J. Xiang, S. K. Natarajan, M. Tremmel, D. Ma, J. Mocco, L. N. Hopkins, A. H. Siddiqui, E. I. Levy and H. Meng, Hemodynamic-morphologic discriminants for intracranial aneurysm rupture, Stroke, 42 (2011) 144–152.
M. R. Sadeghi, E. Shirani, M. Tafazzoli-Shadpour and M. Samaee, The effects of stenosis severity on the hemodynamic parameters-assessment of the correlation between stress phase angle and wall shear stress, J. Biomech., 44 (15) (2011) 2614–2626.
M. Jahangiri, M. Saghafian and M. R. Sadeghi, Numerical study of turbulent pulsatile blood flow through stenosed artery using fluid-solid interaction, Comput. Math. Methods Med. (2015) Article ID 515613.
M. Jahangiri, M. Saghafian and M. R. Sadeghi, Numerical simulation of hemodynamic parameters of turbulent and pulsatile blood flow in flexible artery with single and double stenoses, J. Mech. Sci. Technol., 29 (8) (2015) 3549–3560.
S. Van Wyk, L. P. Wittberg and L. Fuchs, Atherosclerotic indicators for blood-like fluids in 90-degree arterial-like bifurcations, Comput. Biol. Med., 50 (2014) 56–69.
M. Jahangiri, M. Saghafian and M. R. Sadeghi, Effects of non-Newtonian behavior of blood on wall shear stress in an elastic vessel with simple and consecutive stenosis, Biomed. Pharmacol. J., 8 (1) (2015) 123–131.
F. Rikhtegar, J. A. Knight, U. Olgac, S. C. Saur, D. Poulikakos, W. Marshall, P. C. Cattin, H. Alkadhi and V. Kurtcuoglu, Choosing the optimal wall shear parameter for the prediction of plaque location-A patient-specific computational study in human left coronary arteries, Atherosclerosis, 221 (2) (2012) 432–437.
M. R. M. Razavi, S. H. Seyedein and P. B. Shahabi, Numerical study of hemodynamic wall parameters on pulsatile flow through arterial stenosis, IUST International Journal of Engineering Science, 17 (3–4) (2006) 37–46.
J. Chen and X. Y. Lu, Numerical investigation of the non-Newtonian pulsatile blood flow in a bifurcation model with a non-planar branch, J. Biomech., 39 (2006) 818–832.
H. A. G. Rojas, Numerical implementation of viscoelastic blood flow in a simplified arterial geometry, Med. Eng. Phys., 29 (4) (2007) 491–496.
A. Hundertmark-Zauskova and M. Lukacova-Medvidova, Numerical study of shear-dependent non-Newtonian fluids in compliant vessels, Comput. Math. with Appl., 60 (3) (2010) 572–590.
M. Toloui, B. Firoozabadi and M. S. Saidi, A numerical study of the effects of blood rheology and vessel deformability on the hemodynamics of carotid bifurcation, Sci. Iran., 19 (1) (2012) 119–126.
F. Kabinejadian and D. N. Ghista, Compliant model of a coupled sequential coronary arterial bypass graft: Effects of vessel wall elasticity and non-Newtonian rheology on blood flow regime and hemodynamic parameters distribution, Med. Eng. Phys., 34 (7) (2012) 860–872.
M. K. Banerjee, R. Ganguly and A. Datta, Effect of pulsatile flow waveform and womersley number on the flow in stenosed arterial geometry, ISRN Biomath., Article ID 853056 (2012) 1–17.
Z. Mortazavinia and E. G. Rad, Study of pulsatile non-Newtonian blood flow through abdominal aorta and renal arteries incorporating fluid-structure interaction, J. Biomed. Phys. Eng., 2 (3) (2012) 93–102.
V. M. Pereira, O. Brina, A. Marcos Gonzales, A. P. Narata, P. Bijlenga, K. Schaller, K. O. Lovblad and R. Ouared, Evaluation of the influence of inlet boundary conditions on computational fluid dynamics for intracranial aneurysms: A virtual experiment, J. Biomech., 46 (9) (2013) 1531–1539.
S. M. Abdul Khader, A. Ayachit, R. Pai, K. A. Ahmed, V. R. K. Rao and S. G. Kamath, FSI simulation of increased severity in patient specific common carotid artery stenosis, 3rd International Conference on Mechanical, Electronics and Mechatronics Engineering, Abu Dhabi (UAE) (2014).
J. Xiang, A. H. Siddiqui and H. Meng, The effect of inlet waveforms on computational hemodynamics of patientspecific intracranial aneurysms, J. Biomech., 47 (16) (2014) 3882–3890.
G. J. Harrison, T. V. How, R. J. Poole, J. A. Brennan, J. B. Naik, S. R. Vallabhaneni and R. K. Fisher, Closure technique after carotid endarterectomy influences local hemodynamics, J. Vasc. Surg., 60 (2) (2014) 418–427.
M. Blagojevic, A. Nikolic, M. Zivkovic, M. Zivkovic and G. Stankovic, A novel framework for fluid/structure interaction in rapid subject-specific simulations of blood flow in coronary artery bifurcations, Vojn. Pregl., 71 (3) (2014) 285–292.
K. Gayathri and K. Shailendhra, Pulsatile blood flow in large arteries: comparative study of Burton’s and McDonald's models, Appl. Math. Mech. (-Engl. Ed.), 35 (5) (2014) 575–590.
T. Meirson, E. Orion, C. Di Mario, C. Webb, N. Patel, K. M. Channon, Y. Ben Gal and D. P. Taggart, Flow patterns in externally stented saphenous vein grafts and development of intimal hyperplasia, J. Thorac. Cardiovasc. Surg., 150 (4) (2015) 871–878.
J. Fan, Y. Wang, J. Liu, L. Jing, C. Wang, C. Li, X. Yang and Y. Zhang, Morphological-hemodynamic characteristics of intracranial bifurcation mirror aneurysms, World Neurosurg., 84 (1) (2015) 114–120.
Theory and modeling guide, Volume III: ADINA CFD & FSI, Help of ADINA software (2011).
A. Razavi, E. Shirani and M. R. Sadeghi, Numerical simulation of blood pulsatile flow in a stenosed carotid artery using different rheological models, J. Biomech., 44 (11) (2011) 2021–2030.
T. J. Pedley, The Fluid Mechanics of Large Blood Vessels, Cambridge University Press, Cambridge (1980).
W. Y. Chan, Y. Ding and J. Y. Tu, Modeling of non-Newtonian blood flow through a stenosed artery incorporating fluid-structure interaction, ANZIAM J., 47 (2007) 507–523.
Y. I. Cho and K. R. Kensey, Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel, Part 1: Steady flows, Biorheology, 28 (3–4) (1991) 241–262.
E. W. Merril, C. S. Cheng and G. A. Pelletier, Yield stress of normal human blood as a function of endogenous fibrinogen, J. Appl Physiol., 26 (1) (1969) 10–23.
B. M. Johnston, P. R. Johnston, S. Corney and D. Kilpatrick, Non-Newtonian blood flow in human right coronary arteries: steady state simulations, J. Biomech., 37 (2004) 709–720.
R. B. Bird, R. C. Armstrong and O. Hassager, Dynamics of polymer liquids, 2nd Ed., Wiley, New York (1987).
Y. C. Fung, Biomechanics: Mechanical Properties of Living Tissues, 2nd Edition, Springer, Berlin (1993).
P. D. Ballyk, D. A. Steinman and C. R. Ethier, Simulation of non-Newtonian blood flow in an end-to-end anastomosis, Biorheology, 31 (5) (1994) 565–586.
W. R. Mower, W. J. Quinonse and S. S. Gambhir, Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress, J. Vasc. Surg., 26 (1997) 602–608.
D. Zeng, E. Boutsianis, M. Ammann and K. Boomsma, A study on the compliance of a right coronary artery and its impact on wall shear stress, J. Biomech. Eng., 130 (4) (2008) Article ID 041014.
M. R. Sadeghi, Numerical simulation of blood flow in vessels with arterial stenosis considering fluid structure interaction, Ph.D. Thesis, Graduate school of Mechanical Engineering, Isfahan University of Technology (2013).
S. Fazli, E. Shirani and M. R. Sadeghi, Numerical simulation of LDL mass transfer in a common carotid artery under pulsatile flow, J. Biomech., 44 (1) (2011) 2021–2030.
Author information
Authors and Affiliations
Corresponding author
Additional information
Recommended by Associate Editor Sung Yang
Mehdi Jahangiri is Ph.D. student of Mechanical Engineering at Isfahan Universit of Technology, Iran. His current research interests include biomechanical and renewable energy.
Rights and permissions
About this article
Cite this article
Jahangiri, M., Saghafian, M. & Sadeghi, M.R. Numerical simulation of non-Newtonian models effect on hemodynamic factors of pulsatile blood flow in elastic stenosed artery. J Mech Sci Technol 31, 1003–1013 (2017). https://doi.org/10.1007/s12206-017-0153-x
Received:
Revised:
Accepted:
Published:
Issue Date: