Abstract
Purpose of review
With the rapid growth of cholangiopancreatoscopy, several platforms of cholangiopancreatoscopy have been currently available. Since the introduction of digital single-operator cholangiopancreatoscopy, there have been several reports describing its efficacy for long-standing and novel applications. The purpose of this review is to show the current status and future perspective of cholangiopancreatoscopy.
Recent findings
Meta-analysis of cholangiopancreatoscopy have demonstrated good diagnostic yield for visual impression; however, it should be noted that there is no standardized classification system used for distinguishing benign from malignant lesions. In contrast, utility of tissue sampling under direct vision for cholangiopancreatic disorders is inconclusive. This could be explained by the fact that available devices (e.g., biopsy forceps) are limited by the small diameter of accessory channel. Regarding therapeutic applications, several studies demonstrated efficacy and feasibility of electrohydraulic lithotripsy or laser lithotripsy for difficult bile duct stone and pancreatic duct stone under cholangiopancreatoscopic guidance. Additionally, ablation of tumors, selective guidewire placement, retrieval of migrated stents, and anterograde cholangioscopy-guided procedure by using cholangiopancreatoscopy have been reported.
Summary
The recent development of digital single-operator cholangiopancreatoscopy enables easy access to the bile duct and pancreatic duct, contributing to expanding indications for cholangiopancreatoscopy. Improvement of devices or development of innovative devices is required to overcome the remaining problems of cholangiopancreatoscopy.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Cholangioscopy was initially described as peroral cholangioscopy (POCS) under duodenoscopic guidance in 1976 [1]. Subsequently, POCS has been developed to enable direct visualization of the inside of the biliary tree. Previously, image quality was low with the use of fiber optic system; however, a new video cholangioscope was introduced in 1999 with a high-quality digital image and a smaller scope diameter owing to improvements of very small charge-coupled devices [2]. In particular, usefulness of video POCS using a narrow-band imaging (NBI) system has been reported. POCS with NBI can provide clearer images of mucosal vessels and structures [3,4,5]. Peroral pancreatoscopy (POPS) was introduced and evaluated in a similar way.
Video POCS and POPS have potential for changing diagnostic or therapeutic strategy of pancreatobiliary diseases; however, these have not prevailed because of their fragility and requirement of the participation of two skilled endoscopists using two endoscopic systems. To overcome these drawbacks, direct POCS using ultra-slim upper endoscope (D-POCS) has been reported as a single-operator system [6,7,8]. D-POCS allows a greater variety of procedures with a larger diameter of accessory channel under excellent imaging even with an image-enhanced function system. However, scope insertion is still challenging, which avoids widespread use. Single-operator cholangioscopy consisting of disposable parts was introduced in 2007, which allowed for widespread dissemination use owing to its good maneuverability and single-operator system [9, 10]. Additionally, image quality and maneuverability has been improved in the newer generation, contributing to conversion of single-operator cholangioscopy from an advanced technique into a standard technique in clinical practice. In this article, we focus on the current status and future perspective of peroral cholangiopancreatoscopy.
Instruments and procedure
There are several platforms of currently available cholangiopancreatoscopy. It is important to understand the features of each platform as below, in an effort to select suitable cholangiopancreatoscopy.
Video cholangiopancreatoscopy
Peroral cholangiopancreatoscopy are composed of a mother duodenoscope and a baby cholangioscope. The baby scope is inserted into the bile duct through the accessory channel of a conventional therapeutic duodenoscope that acts as the mother scope. This insertion technique is called mother-baby scope insertion system (MBSS) [11]. One of a currently available video cholangiopancreatoscope as the baby scope (CHF-B260; Olympus Medical Systems, Tokyo, Japan) has a two-way angulation function, an outer diameter of 3.4 mm, and an accessory channel diameter of 1.2 mm [12, 13••]. This cholangiopancreatoscope can provide an excellent image with NBI system. Some advantages of peroral video cholangiopancreatoscopy with MBSS are as follows: (1) an excellent image is obtained, (2) the NBI system can be used, (3) insertion of the baby scope is comparatively easy, (4) the baby scope positioning in the bile duct is stable, and (5) the smaller outer diameter enables it to be used even for normal bile duct and intrahepatic bile duct [12]. In contrast, some disadvantages of video cholangiopancreatoscopy with MBSS are as follows: (1) baby scope fragility, (2) limitation of the working channel caliber, and (3) requirement of the participation of two skilled endoscopists using two endoscopic systems [12]. Peroral video cholangiopancreatoscopy with MBSS has potential for changing diagnostic and therapeutic strategies of pancreatobiliary diseases; however, it is not widely used because of these drawbacks. Given new video cholangioscope (CHF-B290; Olympus Medical Systems, Tokyo, Japan) has just launched, further development of image quality and durability is expected.
Direct video peroral cholangiopancreatoscopy
D-POCS using ultra-slim upper endoscope has been proposed as a single-operator system for direct endoscopic examination of the bile duct. The ultra-slim endoscope was originally designed for use in pediatric patients and for transnasal applications; therefore, several ultra-slim endoscopes are commercially available [12, 13••]. These ultra-slim endoscopes have a four-way angulation function and outer diameters of 5.0–5.9 mm with a 2-mm working channel, which can provide excellent images and can be used with image-enhanced function system including NBI. On the other hand, D-POCS has some disadvantages: difficulty in scope insertion to the bile duct and a larger outer diameter that limits the indications for which it can be used [12, 14, 15].
Single-operator cholangiopancreatoscopy
SpyGlass direct visualization system was introduced in 2007 and is designed for single-operator examination [9, 10]. This system was firstly composed of a reusable optical probe (SpyGlass Direct Visualization Probe; Boston Scientific Corporation, Marlborough, MA, USA) and a disposable delivery catheter (SpyScope; Boston Scientific Corporation, Marlborough, MA, USA). The delivery catheter has a four-way deflected steering, an outer diameter of 3.3 mm, and a 1.2-mm accessory channel [9]. This delivery catheter can be inserted through an accessory channel of therapeutic duodenoscope similar to MBSS; however, the four-way deflected steering makes it easier to visualize a target compared with a video cholangiopancreatoscopy. Additionally, the delivery catheter has dedicated irrigation channel, which enables continuous water irrigation for clear image. Nevertheless, this first SpyGlass direct visualization system had significant limitations related to the optical fiber system, including limited image quality and fiberoptic probe durability. This semi-disposable system is referred to as SpyGlass Legacy, because innovations in the system enabled to introduce digital single-operator cholangiopancreatoscopy: SpyGlass DS direct visualization system (SpyGlass DS), with improved image quality and better maneuverability of the catheter tip [16]. Improvement of image quality was supported by the study using a biliary tract bench model [16]. Some advantages of SpyGlass DS are as follows: (1) single-operator examination, (2) fully-disposable system, (3) four-way deflected steering, (4) dedicated irrigation channel, and (5) markedly improved image quality compared with SpyGlass Legacy [12, 16]. These advantages have brought SpyGlass DS into mainstream and widespread use, although it has some disadvantages including limited diameter of the working channel and inability of image-enhanced function systems.
Direct peroral cholangioscopy using balloon-assisted endoscope for cases with altered anatomy
Although endoscopic therapy for bile duct stone or biliary stricture with altered anatomy is still challenging, endoscopic retrograde cholangiopancreatography (ERCP)-related procedure using balloon-assisted endoscope and endoscopic ultrasonography-guided procedure have been attracting attention. Direct peroral cholangioscopy using a balloon-assisted endoscope have been reported recently, although indicated cases are limited to patients who undergo bile duct resection and pancreaticoduodenectomy with a dilated bile duct. Some reports revealed high technical success rate and feasibility of D-POCS-related procedures using double-balloon enteroscope or single-balloon enteroscope [17, 18]. The advantages of D-POCS using balloon assisted endoscopy are as follows: (1) excellent image with image-enhanced function system, (2) larger diameter of the accessory channel, and (3) endoscopic stability within the bile duct, although D-POCS using balloon-assisted endoscopy has a disadvantage including limited indication as noted above.
We reported a novel technique of direct POCS using SpyGlass DS with the overtube [19]. First, conventional balloon-assisted endoscope was inserted to the papilla or anastomotic site, and balloon dilation of papilla or anastomotic site was performed consecutively. Second, balloon-assisted endoscope was removed, leaving a guidewire in the bile duct and the overtube with inflated balloon. Third, SpyGlass DS was inserted into the bile duct over the guidewire through the overtube. This technique was named the “monorail technique,” which may broaden the indication to the case with smaller bile duct compared with D-POCS using.
Clinical applications
Peroral cholangiopancreatoscopy is used for both diagnostic and therapeutic purpose. Suitable cholangiopancreatoscopy should be selected from the currently available platforms described above, according to each cases and skill of an endoscopist; however, indication of cholangiopancreatoscopy is the same as below regardless of the choice of platform.
Diagnostic application of POCS
Endoscopic visual diagnosis for biliary diseases
Osanai et al. reported good diagnostic yield of video POCS using MBSS for indeterminate biliary disease and preoperative mucosal cancerous extension: sensitivity 96.4%, specificity 80.0%, and accuracy 92.1% [20]. In addition, meta-analysis of POCS including video POCS, SpyGlass Legacy, and D-POCS also revealed good diagnostic yield for visual impression (sensitivity 93%, specificity 85%, and accuracy 89%) [21]. The results of recent studies are listed in Table 1. However, it should be noted that there is no standardized classification system used for distinguishing benign lesions from malignant lesions [5, 22]. Mounzer et al. firstly evaluated the individual video of POCS findings and reported that tortuous and dilated vessels, infiltrative stricture, polypoid mass, and the presence of fish-egg lesions were significantly associated with neoplasm [23••]. Although this study is very important and contributory to establish endoscopic classification of pancreatobiliary diseases, there is discrepancy in some of the result between this study and the previous studies. Regarding tortuous and dilated vessels, we reported that dilated and tortuous vessels were observed even in patients with IgG4-related sclerosing cholangitis [24]. Additionally, we conducted ex vivo fundamental study to reveal the difficulty in diagnosing biliary neoplasm only by the existence of abnormal vessels, highlighting the importance of evaluating the form of abnormal vessels [25].
Korrapati et al. described in the aforementioned meta-analysis that SpyGlass Legacy had a significantly reduced sensitivity for visual impression when compared with video POCS [21], whereas several reports revealed good diagnostic yield of SpyGlass DS owing to improvement of image quality [26, 27••]. Navaneethan et al. conducted a multi-center study on SpyGlass DS and demonstrated that the sensitivity and specificity of SpyGlass DS visual impression for diagnosis of malignancy was 90% and 95.8%, respectively [28••]. In addition, Kanno et al. reported that the visual diagnosis using SpyGlass DS for tumor extension of extrahepatic cholangiocarcinoma was acceptable when compared with video POCS [29]. Improvement of image quality of SpyGlass DS obviously contributes to these results, which is supported by the retrospectively comparative study of SpyGlass Legacy and SpyGlass DS [30]. Taken together, it is conceivable that visual diagnosis of SpyGlass DS is reliable; however, it should be noted again that there is no standardized classification system of endoscopic findings of biliary diseases. Further study is required to establish endoscopic visual diagnosis.
Tissue sampling under direct vision
Aforementioned study on video POCS using MBSS also described that the definitive diagnosis of mucosal tumor extension may require a combination of visual diagnosis and biopsy under direct vision [20]. In addition, Tyberg et al. also evaluated utility of preoperative mapping biopsy using SpyGlass DS and described that it changed the surgical plan in 32 of 105 patients with cholangiocarcinoma [31•]. They uncovered the efficacy of preoperative mapping biopsy using SpyGlass DS. These results are supported by the current situation that endoscopic visual diagnosis has not been fully established. In contrast, a systematic review demonstrated the moderate sensitivity of SpyGlass Legacy-guided biopsy in the diagnosis of malignant biliary stricture (pooled sensitivity 60.1%, specificity 98.0%) [32••]. Several studies also reported moderate diagnostic yield of SpyGlass DS-guided biopsy [21, 33]. A possible explanation for these results is the fact that the same biopsy forceps (SpyBite biopsy forceps; Boston Scientific Corporation, Marlborough, MA, USA) with an outer diameter of 1.0 mm has been used since SpyGlass Legacy was introduced, although SpyGlass system was converted from Legacy into DS. The smaller diameter of the accessory channel may be the main problem or limitation of SpyGlass DS under present circumstances that image quality of SpyGlass has been drastically improved. Based on the above results, the efficacy of tissue sampling under POCS guidance still remains inconclusive, although it should be performed as a complementary approach of visual diagnosis. The results of recent studies are shown in Table 2.
To improve diagnostic performance of tissue sampling under direct vision, Varadarajulu et al. evaluated rapid onsite evaluation (ROSE) of touch imprint cytology when SpyGlass Legacy or DS-guided biopsy was performed, suggesting that the diagnostic outcomes of SpyGlass-guided tissue sampling can be significantly improved by using ROSE of touch imprint cytology (sensitivity 100%, specificity 88.9%, accuracy 93.5%) [34]. ROSE is widely known as a good tool for improving diagnostic yield of endoscopic ultrasound (EUS)-guided tissue sampling [35, 36]. Additionally, false-negative result of cytology can be mainly attributed to insufficient material. In this regard, ROSE may be also useful for the samples obtained using SpyGlass.
As discussed so far, we recommend that diagnostic POCS should be performed for diagnosing indeterminate strictures with inconclusive result of prior tissue sampling and for evaluating tumor extension of bile duct cancer preoperatively. POCS-guided biopsy is also recommended as a complementary approach of visual diagnosis, because endoscopic visual diagnosis of biliary disorders has not been fully established.
Therapeutic applications of POCS
Treatment of difficult-to-treat biliary stone
Management of difficult biliary stones is an important application of POCS. Approximately 85–90% of bile duct stones can be extracted using conventional ERCP-related procedures [37]; however, the removal of bile duct stones may be difficult in the remaining 10–15% of patients [38]. Difficult-to-treat bile duct stone is defined as biliary stones for which various difficulties are encountered during the procedure [39]. With regard to a large or impacted stone, the utility of electrohydraulic lithotripsy (EHL) or laser lithotripsy (LL) under video POCS guidance has been reported [40,41,42]. Recently, several reports have evaluated the feasibility and utility of EHL or LL using SpyGlass, because video POCS with MBSS requires the excellent coordination of two skilled endoscopists and video POCS is fragile as mentioned above. Some retrospective multi-center studies revealed that technical success rates of EHL and LL using SpyGlass DS were 95–97.3% [27, 43]. These studies enrolled the cases with failed stone removal by conventional ERCP method. In addition, two randomized control trials demonstrated better stone clearance rate of LL compared with conventional ERCP-related procedure [44, 45]. Buxbaum et al. reported that stone clearance rate of the LL group was better than the conventional procedure group (93% vs. 67%), although conventional methods were allowed in the LL group [44]. Angsuwatcharakon et al. also reported that mechanical lithotripsy had a significantly lower stone clearance rate in the first session compared with LL (63% vs. 100%). In addition, LL could achieve complete stone removal in 60% of cases with failed mechanical lithotripsy [45]. Although EHL or LL using POCS is effective and feasible, these techniques are still complicated, expensive, and time consuming [39]. Therefore, indication for this procedure may be limited to the cases with unsuccessful conventional ERCP-related procedure. On the other hand, a major advantage of EHL and LL using POCS is reduction in the need for mechanical lithotripsy. Based on these findings, conventional ERCP-related procedure and EHL or LL using POCS should be used as a complementary approach to the treatment of difficult stone.
EHL and LL using SpyGlass have one more advantage to have a potential to reduce radiologic procedure. A prospective study evaluating stone removal for noncomplex bile duct stone using SpyGlass DS in radiation-free setting revealed that all cases underwent successful fluoroscopy-free biliary cannulation and stone extraction and fluoroscopy was required in only 5% cases to confirm stone clearance [46]. POCS in radiation-free setting may become a very promising procedure especially for patients with biliary disorder who are hemodynamically unstable in the intensive care unit.
Ablation of biliary tumors
Catheter-based radiofrequency ablation (RFA) under ERCP guidance has been reported to contribute to obtaining longer stent patency or survival [47,48,49,50]. However, it has been associated with a high adverse event rate, since this procedure is commonly performed under only fluoroscopic guidance [51]. A recent study demonstrated the feasibility and safety of the RFA procedure using SpyGlass DS [52]. Observation of the tumor using POCS was performed in 12 patients with bile duct cancer before and after RFA, and administration of RFA was also performed under POCS guidance. RFA was technically successful in all patients with only one patient developing post-procedure cholangitis. Although long-term outcome of biliary RFA remains to be clarified, the feasibility and safety of POCS-guided RFA may provide clinical benefit.
Selective guidewire placement for complex biliary stricture
In spite of the fact that guidewire placement is the first step of ERCP-related procedures, selective guidewire placement is sometimes difficult especially in cases with biliary stricture. Several studies reported the efficacy of POCS for selective guidewire placement as a result of a subgroup analysis [26, 32••]. Bokemeyer et al. evaluated the utility of SpyGlass DS-guided guidewire placement across complex biliary stricture in 30 procedures of 23 patients with previously failed conventional guidewire placement, revealing that selective guidewire placement was successful in 21 of 30 procedures (70%) [53]. More intensive procedure such as percutaneous treatment has to be performed if conventional ERCP-related procedures fail due to the inability of the guidewire placement; therefore, POCS-guided guidewire placement should be considered especially in the case of complex biliary stricture.
Novel application of POCS
Recently, there have been several reports describing EUS-guided anterograde intervention (EUS-AI) through a temporary fistula between the gastrointestinal tract and intrahepatic bile duct to manage biliary disease especially in patients with surgically altered anatomy [54, 55]. EUS-AI has been attracting attention as an alternative of the percutaneous procedure, because procedures using balloon-assisted endoscopy are often challenging. We reported efficacy and feasibility of POCS-assisted anterograde intervention (POCS-AI) via the created fistula, thus enabling POCS-guided lithotripsy by using EHL for the stones and selective guidewire placement across the anastomotic stricture under direct vision, even when performing EUS-AI [56]. In this procedure, the cholangioscope was inserted over the guidewire through the fistula; therefore, SpyGlass DS is suitable for this procedure due to its good maneuverability, while ultra-slim upper endoscope has been also used for this procedure in some of other reports [57]. POCS-AI is a cutting edge and promising application of POCS, although further studies with long-term follow-up are needed.
Other therapeutic application of POCS
POCS allows endoscopists easy access to the lumen of the bile duct, resulting in several reports demonstrating novel use of POCS other than described above. For example, retrieval of migrated biliary stents and hemostasis by using POCS have been reported recently in the literature [58•, 59].
Clinical application of POPS
Indication of POPS is very limited owing to the outer diameter of the scope. Specifically, both the opening of the ampulla and consecutive dilatation of main pancreatic duct from the papilla to the target area are mandatory for POPS.
Diagnosis of intraductal neoplasms of the pancreas
Several retrospective studies have recently evaluated the efficacy of SpyGlass Legacy or DS for diagnosing intraductal neoplasm, for example, intraductal papillary mucinous neoplasm. Although some of the studies demonstrated that the extent of the examination was often limited to the body or head of the pancreas, the good diagnostic yield of visual diagnosis using SpyGlass Legacy was as follows: sensitivity 87%, specificity 86%, and accuracy 87% [60•]. Additionally, 42–43.8% of cases had findings on POPS that were not seen on EUS or other imaging modalities [61, 62]. In contrast, diagnostic yield of targeting biopsy under POPS guidance was reported to be in the range 0–87% in sensitivity [60•, 63]. Based on those findings, although utility of diagnostic POPS for intraductal neoplasms of the pancreas remains to be clarified, POPS should be considered a promising and complementary tool of diagnosing for intraductal lesions, owing to improved quality of images and maneuverability. The sample size of the previous reports is mostly small; therefore, further studies should be required.
Treatment of pancreatic duct stones using POPS
There are various treatment options for pancreatic duct stones, which include extracorporeal shock wave lithotripsy (ESWL), ERCP-related interventions, and surgery. Endoscopic treatment is less invasive and less cumbersome than ESWL or surgery; therefore, endoscopic treatment is often considered the first approach [64]. However, it is difficult to advance and use devices such as guidewire and basket catheter in the main pancreatic duct, when the stone is large or impacted in the main pancreatic duct. In these situations, endoscopic treatment of pancreatic duct stones under direct vision was one of the options. With the recent development of single-operator cholangioscopy, there have been several reports describing the efficacy of treatment of pancreatic duct stones. Ogura et al. retrospectively evaluated the utility of EHL under direct vision using SpyGlass DS, while complete stone clearance was achieved in 88.2% (18/21) of enrolled cases with only one patient developing mild pancreatitis [65]. The other reports also demonstrated high complete stone clearance rate ranging 80–85% by EHL, LL, or mechanical lithotripsy under SpyGlass DS guidance [61, 66]. A multidisciplinary approach is needed because pancreatic duct stone is inherently difficult to treat; therefore, endoscopic treatment under POCS guidance should be considered a promising alternative.
Other application of POPS
With the development of single-operator pancreatoscopy, POPS also allows endoscopists easy access to the lumen of the dilated pancreatic duct, resulting in several reports demonstrating novel use of POPS other than described above. For example, retrieval of migrated pancreatic stents, dilation of pancreatic duct stricture, laser ablation for treatment of benign, and neoplastic disorders by using POPS have been reported recently in the literature [58•, 61, 67].
Safety of cholangiopancreatoscopy
It still remains controversial whether cholangiopancreatoscopy increases the risk of adverse events. Some studies have demonstrated cholangiopancreatoscopy to be a safe procedure with low adverse event rates and no significant differences between conventional ERCP alone and cholangiopancreatoscopy [27••, 68]. In contrast, other reports have demonstrated a significantly higher overall adverse event rate with POCS and specifically a higher rate of post-procedure cholangitis [32••, 69]. Adverse events of recent reports are listed in Table 3.
Additionally, some serious and potentially fatal complications including air embolization and bile duct perforation have been reported in the previous literature [70•]. In an effort to prevent air embolism, saline or CO2 insufflation is recommended when performing cholangiopancreatoscopy [13••]. With regard to the safety of CO2 insufflation during POCS, Mukewar et al. evaluated it in a porcine model [71]. This study showed that CO2 insufflation during POCS is safe and does not result in biliary barotrauma or vital signs instability. This is a supportive result for the above recommendation.
Conclusion
In conclusion, the recent development of single-operator cholangioscopy enables easy access to the inside of bile duct and pancreatic duct, contributing to expanding the indication of cholangiopancreatoscopy. Recently, there have been several reports describing efficacy of SpyGlass DS for long-standing or novel application with good success rate and safety. In contrast, the diagnostic yield of cholangiopancreatoscopy-guided biopsy has been reported as unsatisfactory, although tissue sampling under direct vision is still necessary because endoscopic findings of pancreatobiliary diseases is halfway through being established. Unsatisfied diagnostic yield of tissue sampling using cholangiopancreatoscopy may be partially due to small biopsy forceps, and cholangiopancreatoscopy-guided procedure inherently remains to be complicated; therefore, improvement of devices or development of innovative devices are required to overcome the remaining problems of cholangiopancreatoscopy.
References and Recommended Reading
Papers of particular interest, published recently, have been highlighted as: • Of importance •• Of major importance
Nakajima M, Akasaka Y, Fukumoto K, Mitsuyoshi Y, Kawai K. Peroral cholangiopancreatoscopy (PCPS) under duodenoscopic guidance. Am J Gastroenterol. 1976;66:241–7. https://doi.org/10.1111/j.1572-0241.1976.tb00816.x.
Igarashi Y, Igarashi Y, Ukita T, Inoue H, Ishiguro J, Ogawa S, et al. Clinical evaluation of the peroral cholangioscopy using a new videoscope. Diagn Ther Endosc. 1999;5:231–7. https://doi.org/10.1155/DTE.5.231.
Itoi T, Sofuni A, Itokawa F, Tsuchiya T, Kurihara T, Ishii K, et al. Peroral cholangioscopic diagnosis of biliary-tract diseases by using narrow-band imaging (with videos). Gastrointest Endosc. 2007;66:730–6. https://doi.org/10.1016/j.gie.2007.02.056.
Okabe Y, Tsuruta O, Naito Y, Suga H, Sata M. Clinical evaluation of peroral cholangioscopy for biliary disease using narrow band imaging. Dig Endosc. 2007;19:S121–5. https://doi.org/10.1111/j.1443-1661.2007.00721.x.
Ishida Y, Itoi T, Okabe Y. Can image-enhanced cholangioscopy distinguish benign from malignant lesions in the biliary duct? Best Pract Res Clin Gastroenterol. 2015;29:611–25. https://doi.org/10.1016/j.bpg.2015.05.007.
Moon JH, Ko BM, Choi HJ, Hong SJ, Cheon YK, Cho YD, et al. Intraductal balloon-guided direct peroral cholangioscopy with an ultraslim upper endoscope (with videos). Gastrointest Endosc. 2009;70:297–302. https://doi.org/10.1016/j.gie.2008.11.019.
Choi HJ, Moon JH, Ko BM, Hong SJ, Koo HC, Cheon YK, et al. Overtube-balloon-assisted direct peroral cholangioscopy by using an ultra-slim upper endoscope (with videos). Gastrointest Endosc. 2009;69:935–40. https://doi.org/10.1016/j.gie.2008.08.043.
Mori A, Mori A, Ohashi N, Ohashi N, Nozaki M, Nozaki M, et al. Feasibility of duodenal balloon-assisted direct cholangioscopy with an ultrathin upper endoscope. Endoscopy. 2012;44:1037–44. https://doi.org/10.1055/s-0032-1309467.
Chen YK. Preclinical characterization of the Spyglass peroral cholangiopancreatoscopy system for direct access, visualization, and biopsy. Gastrointest Endosc. 2007;65:303–11. https://doi.org/10.1016/j.gie.2006.07.048.
Chen YK, Pleskow DK. SpyGlass single-operator peroral cholangiopancreatoscopy system for the diagnosis and therapy of bile-duct disorders: a clinical feasibility study (with video). Gastrointest Endosc. 2007;65:832–41. https://doi.org/10.1016/j.gie.2007.01.025.
Nakajima M, Akasaka Y, Yamaguchi K, Fujimoto S, Kawai K. Direct endoscopic visualization of the bile and pancreatic duct systems by peroral cholangiopancreatoscopy (PCPS). Gastrointest Endosc. 1978;24:141–5. https://doi.org/10.1016/S0016-5107(78)73488-7.
Ishida Y, Itoi T, Okabe Y. Types of peroral cholangioscopy: how to choose the most suitable type of cholangioscopy. Curr Treat Options Gastroenterol. 2016;14:210–9. https://doi.org/10.1007/s11938-016-0090-2.
•• ASGE Technology Committee, Komanduri S, Thosani N, Abu Dayyeh BK, Aslanian HR, Enestvedt BK, et al. Cholangiopancreatoscopy. Gastrointest Endosc. 2016;84:209–21 This report reviews currently available system and accessories of cholangiopancreatoscopy in detail.
Itoi T, Moon JH, Waxman I. Current status of direct peroral cholangioscopy. Dig Endosc. 2011;23:154–7. https://doi.org/10.1111/j.1443-1661.2011.01114.x.
Moon JH, Choi HJ. The role of direct peroral Cholangioscopy using an Ultraslim endoscope for biliary lesions: indications, limitations, and complications. Clin Endosc. 2013;46:537–9. https://doi.org/10.5946/ce.2013.46.5.537.
Shah R, Neuhaus H, Parsi M, Reddy D, Pleskow D. Randomized study of digital single-operator cholangioscope compared to fiberoptic single-operator cholangioscope in a novel cholangioscopy bench model. Endosc Int Open. 2018;06:E851–6.
Tsutsumi K, Kato H, Yabe S, Mizukawa S, Seki H, Akimoto Y, et al. A comparative evaluation of treatment methods for bile duct stones after hepaticojejunostomy between percutaneous transhepatic cholangioscopy and peroral, short double-balloon enteroscopy. Ther Adv Gastroenterol. 2017;10:54–67.
Yamauchi H, Kida M, Okuwaki K, Miyazawa S, Matsumoto T, Uehara K, et al. Therapeutic peroral direct cholangioscopy using a single balloon enteroscope in patients with Roux-en-Y anastomosis (with videos). Surg Endosc. 2017;32:498–506.
Tonozuka R, Itoi T, Sofuni A, Tsuchiya T, Ishii K, Tanaka R, et al. Novel peroral direct digital cholangioscopy-assisted lithotripsy using a monorail technique through the overtube in patients with surgically altered anatomy (with video). Dig Endosc. 2019;31:203–8.
Osanai M, Itoi T, Igarashi Y, Tanaka K, Kida M, Maguchi H, et al. Peroral video cholangioscopy to evaluate indeterminate bile duct lesions and preoperative mucosal cancerous extension: a prospective multicenter study. Endoscopy. 2013;45:635–42.
Korrapati P, Ciolino J, Wani S, Shah J, Watson R, Muthusamy VR, et al. The efficacy of peroral cholangioscopy for difficult bile duct stones and indeterminate strictures: a systematic review and meta-analysis. Endosc Int Open. 2016;4:E263–75.
Ayoub F, Yang D, Draganov PV. Cholangioscopy in the digital era. Transl Gastroenterol Hepatol. 2018;3:82–2. https://doi.org/10.21037/tgh.2018.10.08.
•• Mounzer R, Austin GL, Wani S, Brauer BC, Fukami N, Shah RJ. Per-oral video cholangiopancreatoscopy with narrow-band imaging for the evaluation of indeterminate pancreaticobiliary disease. Gastrointest Endosc. 2017;85:509–17. https://doi.org/10.1186/s12981-019-0217-3. This is the first study on individual findings of video cholangioscopy.
Itoi T, Kamisawa T, Igarashi Y, Kawakami H, Yasuda I, Itokawa F, et al. The role of peroral video cholangioscopy in patients with IgG4-related sclerosing cholangitis. J Gastroenterol. 2013;48:504–14. https://doi.org/10.1007/s00535-012-0652-6.
Ishida Y, Okabe Y, Yasumoto M, Naito Y, Nakama Y, Kitasato Y, et al. Ex vivo magnifying endoscopic observation of bile duct mucosa using narrowband imaging. J Hepatobiliary Pancreat Sci. 2018;25:433–9. https://doi.org/10.1002/jhbp.581.
Ogura T, Imanishi M, Kurisu Y, Onda S, Sano T, Takagi W, et al. Prospective evaluation of digital single-operator cholangioscope for diagnostic and therapeutic procedures (with videos). Dig Endosc. 2017;29:782–9. https://doi.org/10.1111/den.12878.
•• Turowski F, Hügle U, Dormann A, Bechtler M, Jakobs R, Gottschalk U, et al. Diagnostic and therapeutic single-operator cholangiopancreatoscopy with SpyGlassDS™: results of a multicenter retrospective cohort study. Surg Endosc. 2018;32:3981–8 This study demonstrates efficacy of SpyGlass DS for diagnostic and therapeutic procedure.
•• Navaneethan U, Hasan MK, Kommaraju K, Zhu X, Hebert-Magee S, Hawes RH, et al. Digital, single-operator cholangiopancreatoscopy in the diagnosis and management of pancreatobiliary disorders: a multicenter clinical experience (with video). Gastrointest Endosc. 2016;84:649–55 This study reveals efficacy of SpyGlass DS for diagnostic and therapeutic procedure.
Kanno Y, Koshita S, Ogawa T, Masu K, Kusunose H, Sakai T, et al. Peroral cholangioscopy by SpyGlass DS versus CHF-B260 for evaluation of the lateral spread of extrahepatic cholangiocarcinoma. Endosc Int Open. 2018;6:E1349–54. https://doi.org/10.1055/a-0743-5283.
Mizrahi M, Khoury T, Wang Y, Cohen J, Sheridan J, Chuttani R, et al. “Apple Far from the Tree”: comparative effectiveness of fiberoptic single-operator cholangiopancreatoscopy (FSOCP) and digital SOCP (DSOCP). HPB (Oxford). 2018;20:285–8. https://doi.org/10.1016/j.hpb.2017.09.002.
• Tyberg A, Raijman I, Siddiqui A, Arnelo U, Adler DG, Xu M-M, et al. Digital pancreaticocholangioscopy for mapping of pancreaticobiliary neoplasia: can we alter the surgical resection margin? J. Clin. Gastroenterol. 2019;53:71–5 This study evaluates mapping biopsy to reveal clinical impact of SpyGlass DS.
•• Navaneethan U, Hasan MK, Lourdusamy V, Njei B, Varadarajulu S, Hawes RH. Single-operator cholangioscopy and targeted biopsies in the diagnosis of indeterminate biliary strictures: a systematic review. Gastrointest Endosc. 2015;82:608–614.e2. https://doi.org/10.1093/gastro/goy049. This study reveals the diagnostic yield of cholangioscopy-guided biopsy.
Lenze F, Bokemeyer A, Gross D, Nowacki T, Bettenworth D, Ullerich H. Safety, diagnostic accuracy and therapeutic efficacy of digital single-operator cholangioscopy. United European Gastroenterol J. 2018;6:902–9. https://doi.org/10.1177/2050640618764943.
Varadarajulu S, Bang JY, Hasan MK, Navaneethan U, Hawes R, Hebert-Magee S. Improving the diagnostic yield of single-operator cholangioscopy-guided biopsy of indeterminate biliary strictures: ROSE to the rescue? (with video). Gastrointest Endosc. 2016;84:681–7. https://doi.org/10.1016/j.gie.2016.03.1497.
Klapman JB, Logrono R, Dye CE, WAXMAN I. Clinical impact of on-site cytopathology interpretation on endoscopic ultrasound-guided fine needle aspiration. Am J Gastroenterol. 2003;98:1289–94. https://doi.org/10.1111/j.1572-0241.2003.07472.x.
Iglesias-Garcia J, Dominguez-Muñoz JE, Abdulkader I, Larino-Noia J, Eugenyeva E, Lozano-Leon A, et al. Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses. Am J Gastroenterol. 2011;106:1705–10. https://doi.org/10.1038/ajg.2011.119.
Seitz U, Bapaye A, Bohnacker S, Navarrete C, Maydeo A, Soehendra N. Advances in therapeutic endoscopic treatment of common bile duct stones. World J Surg. 1998;22:1133–44. https://doi.org/10.1007/s002689900532.
McHenry L, Lehman G. Difficult bile duct stones. Curr Treat Options Gastroenterol. 2006;9:123–32. https://doi.org/10.1007/s11938-006-0031-6.
Yasuda I, Itoi T. Recent advances in endoscopic management of difficult bile duct stones. Dig Endosc. 2013;25:376–85. https://doi.org/10.1111/den.12118.
Leung JW, Chung SS. Electrohydraulic lithotripsy with peroral choledochoscopy. BMJ. 1989;299:595–8. https://doi.org/10.1136/bmj.299.6699.595.
Neuhaus H, Zillinger C, Born P, Ott R, Allescher H, Rosch T, et al. Randomized study of intracorporeal laser lithotripsy versus extracorporeal shock-wave lithotripsy for difficult bile duct stones. Gastrointest Endosc. 1998;47:327–34. https://doi.org/10.1016/S0016-5107(98)70214-7.
Binmoeller KF, Bruckner M, Thonke F, Soehendra N. Treatment of difficult bile duct stones using mechanical, electrohydraulic and extracorporeal shock wave lithotripsy. Endoscopy. 1993;25:201–6. https://doi.org/10.1055/s-2007-1010293.
Brewer Gutierrez OI, Bekkali NLH, Raijman I, Sturgess R, Sejpal DV, Aridi HD, et al. Efficacy and Safety of Digital Single-Operator Cholangioscopy for Difficult Biliary Stones. Clin Gastroenterol Hepatol. 2018;16:918–926.e1. https://doi.org/10.1016/j.gie.2019.01.023.
Buxbaum J, Sahakian A, Ko C, Jayaram P, Lane C, Yu CY, et al. Randomized trial of cholangioscopy-guided laser lithotripsy versus conventional therapy for large bile duct stones (with videos). Gastrointest Endosc. 2018;87:1050–60. https://doi.org/10.1016/j.gie.2017.08.021.
Angsuwatcharakon P, Kulpatcharapong S, Ridtitid W, Boonmee C, Piyachaturawat P, Kongkam P, et al. Digital cholangioscopy-guided laser versus mechanical lithotripsy for large bile duct stone removal after failed papillary large-balloon dilation: a randomized study. Endoscopy. 2019:1–4. https://doi.org/10.1055/a-0848-8373.
Barakat MT, Girotra M, Choudhary A, Huang RJ, Sethi S, Banerjee S. A prospective evaluation of radiation-free direct solitary cholangioscopy for the management of choledocholithiasis. Gastrointest Endosc. 2018;87:584–589.e1.
Itoi T, Isayama H, Sofuni A, Itokawa F, Tamura M, Watanabe Y, et al. Evaluation of effects of a novel endoscopically applied radiofrequency ablation biliary catheter using an ex-vivo pig liver. J Hepatobiliary Pancreat Sci. 2012;19:543–7.
Steel AW, Postgate AJ, Khorsandi S, Nicholls J, Jiao L, Vlavianos P, et al. Endoscopically applied radiofrequency ablation appears to be safe in the treatment of malignant biliary obstruction. Gastrointest Endosc. 2011;73:149–53. https://doi.org/10.1016/j.gie.2010.09.031.
Dolak W, Schreiber F, Schwaighofer H, Gschwantler M, Plieschnegger W, Ziachehabi A, et al. Endoscopic radiofrequency ablation for malignant biliary obstruction: a nationwide retrospective study of 84 consecutive applications. Surg Endosc. 2014;28:854–60. https://doi.org/10.1007/s00464-013-3232-9.
Strand DS, Cosgrove ND, Patrie JT, Cox DG, Bauer TW, Adams RB, et al. ERCP-directed radiofrequency ablation and photodynamic therapy are associated with comparable survival in the treatment of unresectable cholangiocarcinoma. Gastrointest Endosc. 2014;80:794–804. https://doi.org/10.1016/j.gie.2014.02.1030.
Mensah ET, Martin J, Topazian M. Radiofrequency ablation for biliary malignancies. Curr Opin Gastroenterol. 2016;32:238–43.
Ogura T, Onda S, Sano T, Takagi W, Okuda A, Miyano A, et al. Evaluation of the safety of endoscopic radiofrequency ablation for malignant biliary stricture using a digital peroral cholangioscope (with videos). Dig Endosc. 2017;29:712–7. https://doi.org/10.1111/den.12837.
Bokemeyer A, Gross D, Brückner M, Nowacki T, Bettenworth D, Schmidt H, et al. Digital single-operator cholangioscopy: a useful tool for selective guidewire placements across complex biliary strictures. Surg Endosc. 2019;33:731–7. https://doi.org/10.1007/s00464-018-6334-6.
Itoi T, Sofuni A, Tsuchiya T, Ijima M, Iwashita T. Endoscopic ultrasonography-guided transhepatic antegrade stone removal in patients with surgically altered anatomy: case series and technical review (with videos). J Hepatobiliary Pancreat Sci. 2014;21:E86–93. https://doi.org/10.1002/jhbp.165.
Iwashita T, Nakai Y, Hara K, Isayama H, Itoi T, Park DH. Endoscopic ultrasound-guided antegrade treatment of bile duct stone in patients with surgically altered anatomy: a multicenter retrospective cohort study. J Hepatobiliary Pancreat Sci. 2016;23:227–33. https://doi.org/10.1002/jhbp.329.
Mukai S, Itoi T, Sofuni A, Tsuchiya T, Tanaka R, Tonozuka R, et al. EUS-guided antegrade intervention for benign biliary diseases in patients with surgically altered anatomy (with videos). Gastrointest Endosc. 2019;89:399–407. https://doi.org/10.1016/j.gie.2018.07.030.
Hosmer A, Abdelfatah MM, Law R, Baron TH. Endoscopic ultrasound-guided hepaticogastrostomy and antegrade clearance of biliary lithiasis in patients with surgically-altered anatomy. Endosc Int Open. 2018;6:E127–30.
• Tanaka R, Itoi T, Honjo M, Tsuchiya T, Kurihara T, Tsuji S, et al. New digital cholangiopancreatoscopy for diagnosis and therapy of pancreaticobiliary diseases (with videos). J Hepatobiliary Pancreat Sci. 2016;23:220–6 This is first study describing utility of SpyGlass DS, revealing many applications of SpyGlass DS.
Komaki Y, Kanmura S, Funakawa K, Komaki F, Hashimoto S, Taguchi H, et al. A case of hereditary hemorrhagic telangiectasia with repeated hemobilia arrested by argon plasma coagulation under direct peroral cholangioscopy. Gastrointest Endosc. 2014;80:528–9. https://doi.org/10.1016/j.gie.2014.04.022.
• Hajj El II, Brauer BC, Wani S, Fukami N, Attwell AR, Shah RJ. Role of per-oral pancreatoscopy in the evaluation of suspected pancreatic duct neoplasia: a 13-year U.S. single-center experience. Gastrointest Endosc. 2017;85:737–45 This study reveals the good diagnostic yield of pancreatoscopy and also demonstrated endoscopic findings of pancreatic duct neoplasia.
Parbhu SK, Siddiqui AA, Murphy M, Noor A, Taylor LJ, Mills A, et al. Efficacy, safety, and outcomes of endoscopic retrograde cholangiopancreatography with per-oral pancreatoscopy: a multicenter experience. J Clin Gastroenterol. 2017;51:e101–5. https://doi.org/10.1097/MCG.0000000000000796.
Trindade AJ, Benias PC, Kurupathi P, Tharian B, Inamdar S, Sharma N, et al. Digital pancreatoscopy in the evaluation of main duct intraductal papillary mucinous neoplasm: a multicenter study. Endoscopy. 2018;50:1095–8.
Ohtsuka T, Gotoh Y, Nakashima Y, Okayama Y, Nakamura S, Morita M, et al. Role of SpyGlass-DS tm in the preoperative assessment of pancreatic intraductal papillary mucinous neoplasm involving the main pancreatic duct. Pancreatology. 2018;18:566–71. https://doi.org/10.1016/j.pan.2018.04.012.
Beyna T, Neuhaus H, Gerges C. Endoscopic treatment of pancreatic duct stones under direct vision: revolution or resignation? Systematic review. Dig Endosc. 2018;30:29–37. https://doi.org/10.1111/den.12909.
Ogura T, Okuda A, Imanishi M, Miyano A, Amano M, Nishioka N, et al. Electrohydraulic lithotripsy for pancreatic duct stones under digital single-operator pancreatoscopy (with video). Dig Dis Sci. 2018;387:1–6.
Bekkali NLH, Murray S, Johnson GJ, Bandula S, Amin Z, Chapman MH, et al. Pancreatoscopy-directed electrohydraulic lithotripsy for pancreatic ductal stones in painful chronic pancreatitis using SpyGlass. Pancreas. 2017;46:528–30. https://doi.org/10.1097/MPA.0000000000000790.
Mittal C, Shah RJ. Pancreatoscopy-guided laser dissection and ablation for treatment of benign and neoplastic pancreatic disorders: an initial report (with videos). Gastrointest Endosc. 2019;89:384–9. https://doi.org/10.1016/j.gie.2018.08.045.
Draganov PV, Lin T, Chauhan S, Wagh MS, Hou W, Forsmark CE. Prospective evaluation of the clinical utility of ERCP-guided cholangiopancreatoscopy with a new direct visualization system. Gastrointest Endosc. 2011;73:971–9. https://doi.org/10.1016/j.gie.2011.01.003.
Sethi A, Chen YK, Austin GL, Brown WR, Brauer BC, Fukami NN, et al. ERCP with cholangiopancreatoscopy may be associated with higher rates of complications than ERCP alone: a single-center experience. Gastrointest Endosc. 2011;73:251–6. https://doi.org/10.1016/j.gie.2010.08.058.
• Chavalitdhamrong D, Donepudi S, Pu L, Draganov PV. Uncommon and rarely reported adverse events of endoscopic retrograde cholangiopancreatography. Dig Endosc. 2014;26:15–22. https://doi.org/10.1055/s-0034-1392274. This review highlights uncommon adverse events of ERCP-related procedures, which endoscopists should know.
Mukewar S, Gorospe EC, Knipschield MA, Bingener J, Gostout C. Effects of carbon dioxide insufflation during direct cholangioscopy on biliary pressures and vital parameters: a pilot study in porcine models. Gastrointest Endosc. 2017;85:238–242.e1.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
Yusuke Ishida declares that he has no conflict of interest. Takao Itoi declares that he has no conflict of interest. Yoshinobu Okabe declares that he has no conflict of interest.
Human and animal rights and informed consent
This article does not contain any studies with human or animal subjects performed by any of the authors.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Ishida, Y., Itoi, T. & Okabe, Y. Current Status and Future Perspective in Cholangiopancreatoscopy. Curr Treat Options Gastro 17, 327–341 (2019). https://doi.org/10.1007/s11938-019-00238-1
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11938-019-00238-1