Abstract
The major portion of energy in a building is consumed by heating, ventilating, and air-conditioning (HVAC). The traditional heating and cooling systems contribute greatly to the emission of greenhouse gases, especially carbon dioxide. Four different ways, i.e., Trombe wall, solar chimney, unglazed transpired solar façade, and solar roof, are adopted for solar heating. Similarly, two major ways, i.e., evaporative cooling and building integrated evaporative cooling are adopted for cooling of the building. Therefore, an attempt has been made in this paper to compile the developments of solar heating and cooling technologies in a building.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
IEA. World energy outlook 2007: China and India insights. France: OECD/IEA; 2007, http://www.worldenergyoutlook.org/media/weowebsite/2008-1994/weo_2007.pdf
IEA. Renewable for heating and cooling: untapped potential. France: OECD/ IEA; 2007, http://www.iea.org/publications/freepublications/publication/renewable_heating_cooling_final_web.pdf
IEA. Worldwide trends in energy use and efficiency: key insights from IEA indicator analysis. France: OECD/IEA. 2008, https://www.iea.org/publications/freepublications/publication/Indicators_2008.pdf
Weingarten S R, Henning J M, Badamgarav E, Knight K. Interventions used in disease management programmes for patients with chronic illness which ones work? Meta-analysis of Published Reports, 2002
Ong K S, Chow C C. Performance of a solar chimney. Solar Energy, 2003, 74(1): 1–17
Hirunlabh J, Kongduang W, Namprakai P, Khedari J. Study of natural ventilation of houses by a metallic solar wall under tropical climate. Renewable Energy, 1999, 18(1): 109–119
Gan G. Simulation of buoyancy-induced flow in open cavities for natural ventilation. Energy and Building, 2006, 38(5): 410–420
Li A, Jones P, Zhao P, Wang L. Heat transfer and natural ventilation airflow rates from single-sided heated solar chimney for buildings. Journal of Asian Architecture and Building Engineering, 2004, 3(2): 233–238
Zhai X Q, Dai Y J, Wang R Z. Comparison of heating and natural ventilation in a solar house induced by two roof solar collectors. Applied Thermal Engineering, 2005, 25(5-6): 741–757
Khedari J, Mansirisub W, Chaima S, Pratinthong N, Hirunlabh J. Field measurements of performance of roof solar collector. Energy and Building, 2000, 31(3): 171–178
Chan H Y, Riffat S B, Zhu J. Review of passive solar heating and cooling technologies. Renewable & Sustainable Energy Reviews, 2010, 14(2): 781–789
Shen J, Lassue S, Zalewski L, Huang D. Numerical study on thermal behavior of classical or composite Trombe solar walls. Energy and Building, 2007, 39(8): 962–974
Richman R C, Pressnail K D. A more sustainable curtain wall system: analytical modeling of the solar dynamic buffer zone (SDBZ) curtain wall. Building and Environment, 2009, 44(1): 1–10
Gan G. A parametric study of Trombe wall for passive cooling of buildings. Energy and Building, 1998, 27(1): 37–43
Jie J, Hua Y, Gang P, Bin J, Wei H. Study of PV-Trombe wall assisted with DC fan. Building and Environment, 2007, 42(10): 3529–3539
Matuska T, Sourek B. Facçade solar collectors. Solar Energy, 2006, 80(11): 1443–1452
Onishi J, Soeda H, Mizuno M. Numerical study on a low energy architecture based upon distributed heat storage system. Renewable Energy, 2001, 22(1-3): 61–66
Tyagi V V, Buddhi D. PCM thermal storage in buildings: a state of art. Renewable & Sustainable Energy Reviews, 2007, 11(6): 1146–1166
Stritih U. Heat transfer enhancement in latent heat thermal storage system for buildings. Energy and Building, 2003, 35(11): 1097–1104
Miyazaki T, Akisawa A, Kashiwagi T. The effects of solar chimneys on thermal load mitigation of office buildings under the Japanese climate. Renewable Energy, 2006, 31(7): 987–1010
Harris D J, Helwig N. Solar chimney and building ventilation. Applied Energy, 2007, 84(2): 135–146
Raman P, Mande S, Kishore V V N. A passive solar system for thermal comfort conditioning of buildings incomposite climates. Solar Energy, 2001, 70(4): 319–329
Maerefat M, Haghighi A P. Passive cooling of buildings by using integrated earth to air heat exchanger and solar chimney. Renewable Energy, 2010, 35(10): 2316–2324
Wikipedia. Solar air heat.2015–01–21, http://en.wikipedia.org/wiki/Solar_air_heat
Cali A, Kutscher C F, Dymond C S, Pfluger R, Hollick J, Kokko J, McCenahan D, Pfluger R. Low cost high performance solar air heating systems using perforated absorbers. IEA Report No. SHC. T14. Air 1. Washington: International Energy Agency (IEA), 1999
Awbi H B. Chapter 7—ventilation. Renewable & Sustainable Energy Reviews, 1998, 2(1–2): 157–188
Dimoudi A, Androutsopoulos A, Lykoudis S. Summer performance of a ventilated roof component. Energy and Building, 2006, 38(6): 610–617
Amer E H. Passive options for solar cooling of buildings in arid areas. Energy, 2006, 31(8-9): 1332–1344
Florides G A, Tassou S A, Kalogirou S A, Wrobel L C. Review of solar and low energy cooling technologies for buildings. Renewable & Sustainable Energy Reviews, 2002, 6(6): 557–572
Henning H M. Solar-assisted Air-conditioning in Buildings. 2nd ed. New York: Springer, 2007
Daou K, Wang R Z, Xia Z Z. Desiccant cooling air conditioning: a review. Renewable & Sustainable Energy Reviews, 2006, 10(2): 55–77
Fan Y, Luo L, Souyri B. Review of solar sorption refrigeration technologies: development and applications. Renewable & Sustainable Energy Reviews, 2007, 11(8): 1758–1775
Chandel S S, Sarkar A. Performance assessment of a passive solar building for thermal comfort and energy saving in a hilly terrain of India. Energy and Building, 2015, 86: 873–885
Benhammou M, Draoui B, Zerrouki M, Marif Y. Performance analysis of an earth-to-air heat exchanger assisted by a wind tower for passive cooling of buildings in arid and hot climate. Energy Conversion and Management, 2015, 91: 1–11
Coma J, Pérez G, Castell A, Solé C, Cabeza L F. Green roofs as passive system for energy savings in buildings during the cooling period: use of rubber crumbs as drainage layer. Energy Efficiency, 2014, 7(5): 841–849
Lee K H, Lee J K, Yoon E S, Joo M C, Lee S M, Baek N C. Annual measured performance of building-integrated solar energy systems in demonstration low-energy solar house. Journal of Renewable and Sustainable Energy, 2014, 6(4): 042013
Sewalk S, Liston K S, Maher M D. Transpired solar air collectors: An Energy SolarWall. How solarwall technology works to provide fresh air and free heat. Conserval Engineering Inc. 2008–10, solarwall.com/en/products solarwall-air-heating/how-it-works.php
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Nanda, A.K., Panigrahi, C.K. A state-of-the-art review of solar passive building system for heating or cooling purpose. Front. Energy 10, 347–354 (2016). https://doi.org/10.1007/s11708-016-0403-0