1 Introduction

Shape memory alloys (SMA) are materials that can gain their predefined shape or size when subjected to appropriate thermal and mechanical procedures. Studies on SMA materials are increasing day by day and their usage areas are expanding. This material group exhibits two different behaviors in itself: Shape Memory Effect (SME) and superelastisity (Ref 1). SMAs stand out with their mechanical properties such as corrosion resistance, SME and high strength. Compared to other SMAs, NiTi alloys have much better mechanical properties and SME makes this alloy valuable (Ref 2). On the contrary to these advantages, milling process of NiTi SMAs is quite problematic. Strain hardening, high ductility and low thermal conductivity of the alloy result in severe tool wear, poor surface finish, and poor machining efficiency, and it is difficult to meet dimensional accuracy requirements (Ref 3). In addition, the high ductility of the NiTi shape memory alloy is a source of the hard-to-break chips that occur during machining. Therefore, the chip formation process of NiTi SMAs should be investigated (Ref 4, 5).

Many experiments and theoretical analysis have been performed to solve these problems (Ref 3). The use of coolants during the machining process is known to have positive effects on machinability. These positive results are mainly due to the effects of coolant on reducing the temperature, friction and wear amount at the tool-chip interface. It has been reported that cryogenic cooling has also positive effects on the machining of nickel-based superalloys (Ref 6) and titanium alloys (Ref 7). To increase cutting performance in machining of NiTi SMAs, coated cutting tools, the minimal amount of lubrication (MQL) and cryogenic cutting are used as green cutting technologies (Ref 4, 8).

In application of these solutions, the surface integrity is used in evaluation of the machinability of materials due to the fact that the performance of the products depends substantially on surface integrity of the material. General surface integrity properties used are average surface roughness (Ra), metallographic structure, residual stress, and work hardening. Velmurugan et al. reviewed the surface integrity properties of NiTi SMAs under the conventional, unconventional, and micromachining conditions (Ref 9). Kaynak et al. compared the Ra of the NiTi SMAs machined under two different conditions in the turning process with and without cryogenic coolant. As a result of the studies, the increase in the feed rate caused an increase in the Ra values. The Ra values obtained in the cryogenic machining condition were lower than those obtained in the dry machining condition in all feed parameters (Ref 10). Kulkarni et al., in their study of optimization of machining parameters in the processing of NiTi superelastic materials with wire erosion bench, investigated the effects of electrode advance, pulse duration, pulse interval time and the amount of voltage in the spark gap on the metal removal rate and Ra values. The researchers aimed to obtain the maximum metal removal rate and the minimum Ra value in line with the relevant parameters (Ref 1).

Weinert et al. investigated the best cutting conditions for machining NiTi SMAs and the effects of various cutting tool materials on the machinability of this material. Uncoated carbide, various PVD-coated carbides, CBN, PCD and ceramic tools were used as cutting tools. As a result of experimental studies, it has been shown that coated carbide cutting tools exhibit better machinability performance than uncoated carbide cutting tools (Ref 12). In a similar study, Guo et al. (Ref 13) investigated the surface integrity characteristics of Ni50.8Ti49.2 alloy after milling using AlTiN/TiN-coated carbide cutting tools (replaceable inserts using a single active insert). Huang investigated the effects of cutting parameters on tool wear and surface properties using high-speed milling. The authors reported that the increase in cutting speed resulted in an increase in the surface quality, and a decrease in the degree of work hardening. They attributed this to the decreasing of cutting forces due to reducing of chip thickness and chip cross-sectional area (Ref 14). Zhao et al. investigated the surface integrity of NiTi alloy during turning process with the change of cutting speed under cryogenic and dry conditions. They studied on microhardness, work contact layer, and phase transformation of the material. The authors reported that the machinability of the NiTi alloy depends highly on cutting speed (Ref 15). Kaynak et al. combined orthogonal experimentation, shear-induced phase transformation, and simulation and investigated the effect of phase transformation on surface integrity of the NiTi alloy (Ref 16). Zailani and Mativenga performed micro-milling experiments to compare the effects cooled air and MQL on the machinability of NiTi SMA. They reported that the cooled air can make the workpiece structure uniform, decrease the cutting force and the burr height. They also stated that chilled air and MQL have a big influence on decrease burr size, tool wear, and to increase surface roughness (Ref 17). Kaynak et al. studied on the machining induced deformation layer and investigated this layer's effect on the material's potential deformation behavior by experimental design methods. Researchers reported that cryogenic heat treatment causes a stronger effect than dry cutting (Ref 18). Aslantaş and Kaynak (Ref 19) investigated the effects of machining parameters on cutting forces, average surface roughness, and burr width in micro-milling and slot milling studies of Ni55.82Ti44.18 SMA. They stated that increasing cutting speed causes a phase transformation from austenite to martensite by increasing the stresses on the sample, and the hardening chips increase the cutting forces. Wang et al. (Ref 20) performed milling experiments to examine the effect of machining parameters on the strain hardening of Ni50.8 Ti49.2 SMA. As a result of the experimental studies, they determined that the most important parameter affecting the strain hardening is the cutting speed. They stated that the austenite content of the machined surface is higher at high cutting speeds, and therefore, the strain hardening is higher. They found that an increase in the feed rate causes an increase in the shear force and plastic deformation area, and therefore an increase in strain hardening. Kuppuswamy and Yui (Ref 21) studied on the machining parameters in milling process of NiTi alloy to decrease cutting forces and burr formation. As a result of the experimental design, the researchers determined that the most important machining parameters to reduce the cutting forces and burr size in the micro-milling process of NiTi alloy are the cutting speed, feed rate, and depth of cut, respectively. Weinert and Petzoldt (Ref 22) investigated tool wear and machining quality in micro-milling processes of NiTi SMA using the MQL method. As a result of the experiments, they emphasized that the MQL method is necessary to achieve acceptable processing results. They found that the tool life increased, and the surface quality of the sample improved with the MQL method; high cutting width and feed rate provided better chip formation, increased tool life, and sample surface quality. Zhao et al. carried out experiments to examine the effect of cooling conditions on turning NiTi shape memory alloys at different cutting speeds. Tool wear, cutting force and surface morphology were determined as properties evaluated to investigate the effects of different cooling methods and stress-induced martensitic phase during the turning process. The study showed that the appearance of the stress-induced martensitic phase during the turning process impairs the machinability of NiTi shape memory alloys (Ref 23). Kabil et al. studied the optimization of the cutting parameters of NiTiHf high temperature shape memory alloys using a multi-objective optimization method. Empirical models were used to predict outputs in the turning process of NiTiHf and compared with experimental data. It has been determined that cutting parameters such as cutting speed, feed rate, and depth of cut have a great effect on performance. These parameters have been optimized using the Genetic Algorithm to achieve maximum tool life, minimum energy consumption, and maximum surface quality (Ref 24). Optimizing the Ra in milling is a method frequently used by researchers. Many authors evaluated the Ra of different metal materials by optimizing with Taguchi method (Ref 25,26,27,28,29,30).

In the study, the effect of NiTi SMAs on Ra was investigated with the change of machining parameters under dry and MQL conditions with cutting fluids and tungsten carbide (WC) cutting tools with or without cryogenic heat treatment in face milling operations. Optimum cutting conditions and parameters were determined using the Taguchi method, an adequate experimental design method. Thus, recommendations have been made to ensure the surface integrity of this material, which is difficult to process.

2 Experimental Setup

Face milling was carried out to observe the influence of different machining parameters, cutting conditions, and cryogenic heat treatment parameters on the average surface roughness (Ra) of the NiTi SMA. Taguchi optimization was used to reduce the number of experiments. The milling tests were performed by three-axis "Falco VMC 855-B" industrial type CNC vertical machining center with 7.5 kW spindle power. Ra of the machined surface was measured by Mitutoyo Surftest SJ-310 tipped surface roughness measuring device because the Ra is the most commonly used parameter in roughness measurements in literature. After the surface roughness measurements of the milled samples were made, the data obtained were optimized and interpreted. The sampling length was chosen as λ = 0.8 mm and the evaluation length as L = 5.6 mm during the measurement. The schematic representation of the experimental setup is given in Fig. 1. Werte Mikro STN 25 operating at the pressure of 4-6 bar with a lubrication range of 0.0021-0.028 ml was used as the MQL system. The prepared cutting fluid was sprayed into the cutting medium with a nozzle on the system.

Fig. 1.
figure 1

Experimental setup (a) MQL system, (b), (c) and (d) Milling of NiTi SMA plate

2.1 Material and Cutting Tools

NiTi SMA, used in orthopedics to join broken bones, was used as workpiece material in the experimental study. The NiTi SMA used was subjected to hot rolling after it was produced by the VAR (Vacuum Arc Remelting) method, and the material was in the austenite phase at room temperature. It contained 55.8% Ni element in its structure. NiTi SMA plate was prepared in 25 × 100 × 100 mm dimensions. Detailed dimensions and plate photographs of the test sample are shown in Fig. 2. The chemical composition and mechanical properties of NiTi SMA are given in Tables 1 and 2, respectively (Ref 31).

Fig. 2.
figure 2

NiTi plate and basic dimensions

Table 1. Chemical composition of NiTi SMA (%Weight) (Ref 31)
Table 2. Mechanical properties of NiTi SMA (Ref 31)

Phase transformation temperatures of the alloy, i.e., martensite start (Ms), the martensite finish (Mf), austenite start (As), and austenite finish (Af) temperature, were measured by DSC (Diffraction Scanning Calorimetry) method. According to the phase transformation temperatures given in Table 3, the NiTi alloy was seen to be in austenite phase at room temperature before machining.

Table 3. Phase transformation temperatures of the NiTi SMA (Ref 32)

Three different cutting tools belonging to Sandvik Coromant were utilized in the cutting experiments of NiTi SMAs in accordance with the test conditions specified in ISO 1832. These are uncoated, TiAlN coated (by PVD method), and TiN/Al2O3/TiCN coated (by CVD method with a TiN top layer) tungsten carbide cutting tools. To keep the cutting conditions constant during the experiments, each experiment was carried out using new cutting tools. In the experiments, a tool holder with a two-edge, 120 mm height (l2), 25 mm cutting diameter (Dc), 17.06° tilt angle (λs) and the code R390-025A25-11L produced by Sandvik Coromant, suitable for replaceable inserts, was used. The geometry of the tool holder was determined with reference to ISO 5608. Only one cutting tool was mounted onto the tool holder to provide a stable cutting conditions (Fig. 3).

Fig. 3.
figure 3

Geometrical properties of the tool holder and cutting tools utilized in the cutting process

2.2 Cutting Fluids and Cryogenic Process

Borax Decahydrate (Na2B4O7·10H2O) and Ethylene Glycol (EG (C2H6O2)) fluids were prepared as cutting fluid to be used in milling operations of NiTi SMAs. These cutting fluids were applied onto the workpiece at an angle of 45° and from a distance of approximately 30 mm using the MQL (Minimum Quantity Lubrication) system. Borax Decahydrate is a natural alkaline mineral, and it consists of water, oxygen, sodium, and boron. As its alkaline (basic) structure, it acts as a reducing agent in the emulsion, allowing the pH level of the cutting fluid to be increased and the wear resistance to increase (Ref 33, 34). Borax Decahydrate (5% by weight BX) was added to Ethylene Glycol (EG), and boron added (EG+5%BX) cutting fluid was prepared. In order to obtain a homogeneous mixture, the formulated cutting fluids were mixed with a mechanical stirrer at 300 rpm at room temperature for 10 min and then placed in a magnetic stirrer (Ref 33, 35). The technical properties of the prepared cutting fluids are shown in Table 4.

Table 4. Some physical properties of cutting fluids prepared for milling experiments (Ref 32)

Cryogenic heat treatment of cutting tools was carried out in a specially prepared computer-controlled cryogenic processing unit. Two different cryogenic heat treatments were applied to some carbide cutting tools at − 80 ºC and − 196 ºC, while the others were kept as untreated. In order to prevent microcracks that may occur in the cutting tools during cryogenic heat treatment, gradually cooling and heating process was applied to the cutting tools (Ref 36, 37). In order to relieve the stresses that may occur, the cutting tools were tempered by waiting at 200 °C for 2 h after the cryogenic heat treatment.

2.3 Experimental Parameters and Optimization

Uncoated, PVD-coated, and CVD-coated cutting tools were utilized in the cutting experiments of NiTi SMAs. Two different cryogenic heat treatment processes as shallow (− 80 ºC) and deep (− 196 ºC) were applied to some of cutting tools, while the others were kept untreated. Machining experiments were carried out in dry, EG, and EG+5%BX environments. Axial depth of the cut (ap = 0.7 mm) and radial cutting depths (ae = 15 mm) were kept constant and three different cutting speeds (Vc) and feed rate (fz) were determined as a result of preliminary experiments and suggestions of the cutting tool manufacturer as machining parameters. The processing parameters used are given in Table 5.

Table 5. Process parameters and their levels

The Taguchi method was used to determine the optimum machining parameters and to analyze the effects of process parameters on the average surface roughness (Ra). The L27 orthogonal array was chosen as the experimental design. The experimental design created using the specified processing parameters is given in Table 6.

Table 6. The experimental design L27

The effect of each machining parameter on the Ra was analyzed using the S/N ratio. In the Taguchi method, there are performance criteria as nominal best, smallest best, and largest best. The lowest value was taken for the best Ra value in the study, and the "smallest best" performance criterion was selected to calculate the lowest Ra value and the most appropriate S/N ratio for better product quality and the lowest cost. The “smallest best” performance characteristic is given in Eq 1.

$$\frac{S}{N} = - 10.\log \left( {\frac{1}{n}\mathop \sum \limits_{i = 1}^{n} Y_{i}^{2} } \right)$$
(1)

In Eq 1, Y is the average surface roughness, and n notates the number of experiments. The influence of the effect levels of the variables on the Ra was determined by applying ANOVA to the experimental results. Analysis of variance was performed with Minitab 18 software, taking into account the 95% confidence interval.

3 Results and Discussion

The sample Ra data obtained from the milling process of NiTi SMAs by the Taguchi L27 orthogonal test pattern and the S/N ratios calculated using Eq 1 are given in Table 7.

Table 7. Ra and Calculated S/N values relative to the L27 vertical index

Figure 4 shows the relationship of the Ra with the machining parameters using average of S/N ratios and average of measured values.

Fig. 4.
figure 4

Effect of machining parameters on the Ra of NiTi SMA in milling depending on (a) average of S/N ratios, (b) average of measured values

According to the graphical display of S/N ratios Fig. 4(a), optimum test parameters for minimum Ra were defined as CVD cutting tool, − 196 °C cryogenic heat treatment, EG+5%BX cutting fluid, 50 m/min cutting speed, and 0.03 mm/tooth feed rate. In Fig. 5, the influence of machining parameters on the Ra is shown in 3D graphics.

Fig. 5.
figure 5

Influence of cutting parameters on the Ra

When the influence of the coating materials on the Ra was examined, it was concluded that the coatings deposited to the cutting tools improved the Ra. The Ra value (0.490 μm) obtained using the CVD-coated cutting tool was approximately 17% lower than the uncoated cutting tool (0.593 μm). It has been seen that the Ra value of CVD-coated tools is also lower than that of PVD-coated tools. This improvement was attributed to the friction coefficient and thickness of the coating on the CVD-coated tools. These tools have a top TiN coating layer with a low friction coefficient which decreases chip sticking on the tool and makes chip formation easy. In addition, higher thickness of multilayer coating on these tools result in a larger cutting edge radius, which decreases the Ra in accordance with surface roughness theory. Accordingly, an improvement in the Ra of the sample was detected with CVD-coated cutting tools as seen in Ref. (Ref 38,39,40,41).

Applying cryogenic heat treatment to the cutting tools, a decrease was observed in the Ra values. The mean surface roughness value (0.508 μm) obtained using the deep cryogenic heat-treated cutting tool was approximately 7% lower than the value obtained in the non-cryogenic heat-treated cutting tool (0.544 μm). It is thought that the Ra decreases thanks to the preservation of the cutting edge geometry by delaying the tool wear as a result of the increase in the hardness and wear resistance of the cutting tools, especially with deep cryogenic heat treatment (Ref 36, 42). As for the influence of cutting fluids on the Ra, a decrease was found in the Ra in the case of using EG and EG+5%BX cutting fluids. The Ra value (0.465 μm) obtained using EG+5%BX cutting fluid was approximately 20% lower than the value in dry cutting conditions (0.580 μm). In particular, high thermal conductivity and lubricating properties of EG+5%BX provided removal of the temperature in the cutting zone, reduction of the friction between the cutting tool and the sample, thereby reducing the temperature in the cutting zone. Depending on the decrease in friction and cutting temperature, tool hardness is preserved, preventing tool wear and the change of tool geometry. Thus, a reduction of Ra has been observed as observed by Ref 33, 35. As for the effect of the cutting speed on the Ra, it was concluded that the Ra decreased with the increase in the cutting speed. It is thought that at low cutting speeds (20 m/min), the build-up edge (BUE) depositing on the cutting edge acts as a part of the cutting tool, which in turn increases the Ra by changing cutting tool geometry and thus the depth of cut Fig. 6(a) (Ref 43). The improvement of the Ra with the increase in cutting speeds can be explained by the fact that less strain hardening is obtained as the cutting temperature increases at high cutting speed and the chip formation around the cutting edge is facilitated as explained by Ref 31. The Ra value (0.477 μm) obtained at high cutting speed (50 m/min) was approximately 15% lower compared to low cutting speed (20 m/min) value (0.560 μm). The improvement in the Ra due to the increase in cutting speed is an expected feature and the results are in good agreement with the literature (Ref 31, 44).

Fig. 6. 
figure 6

(a) BUE formed on the cutting tool due to milling NiTi SMA in different machining parameters (0.03 mm/tooth feed rate) (b) SEM image of tool wear at high feed rate (0.14 mm/tooth)

The wear on the cutting tool was visualized using a SEM microscope. Figure 6(a) shows the BUE formed, while Fig. 6(b) shows the high feed BUE and tooltip breakage.

As the feed rate increases, the cutting temperature increased due to the rise of chip width and the amount of removed chips. It is known that the generated heat is concentrated at the tool-chip and tool-workpiece interface due to the low thermal conductivity of NiTi SMA. It is an expected result that the Ra values will increase since the permanent stresses on the machined surface will increase with the feed rate similar to Ref 44, 45. The high Ra at a high feed rate (0.14 mm/tooth) is due to cutting tool wear Fig. 6(b). The cutting forces increase with the feed rate due to the increase in chip thickness. Accordingly, the wear formation on the tool accelerates and causes an increase in the Ra as seen in Ref. 31, 46. Finally, the increase in feed rate results in an increase in the Ra in accordance with the surface roughness theory.

So as to show the influence of optimum cutting parameters on the Ra, the experiments at three different machining parameters were carried out. The surface roughness profiles obtained at these machining conditions are shown in Fig. 7. The profiles show that the lowest Ra (0.324 µm) was obtained at optimum cutting parameters (CVD cutting tool, − 196 °C cryogenic heat treatment, EG+5%BX cutting fluid, 50 m/min cutting speed, and 0.03 mm/tooth feed rate. The height of the roughness peaks decreased and the peaks became frequent.

Fig. 7.
figure 7

Surface roughness profiles of NiTi SMA after milling at different cutting parameters

In order to determine the effects of each machining parameter on the Ra in milling of NiTi SMA, ANOVA analysis was performed. It was seen that ANOVA analysis was carried out at a 95% confidence level. The parameters and levels that affect the Ra values are given in Table 8.

Table 8. ANOVA results for the Ra value obtained with different machining parameters in the milling process of NiTi SMA

According to ANOVA results, it was determined that the variable that have the most significant effect on the Ra is the feed rate with 42.99% contribution. It was followed by the cutting tool type by 20.27%, the cutting fluid by 20.25%, the cutting speed by 11.68%, and the cryogenic heat treatment by 1.95%. The main effect plot shown in Fig. 4 and the S/N response values indicated in Table 8 confirmed the analysis of variance. The error in the ANOVA table remained at the level of 2.87%. Since the error effect rates in the ANOVA table are expected to be below 20% for a safe result (Ref 47), it can be stated that the ANOVA results met the standards in this study. According to the regression analysis results, the correlation coefficients established for the Ra are R2 = 97.13%, R2adj = 95.34%, and R2pred = 91.83%. These results show that the model obtained for the mean surface roughness agrees with the experimental data and has a high predictive ability.

The normal probability plot of the residuals and histogram of residuals were used to verify normality assumption. As seen from Fig. 8(a,c), the residuals fall approximately along a straight line, and this means that the errors are in the normal distribution and the terms mentioned in the model are the only significant (Ref 48, 49). There is no systematic pattern and unusual structure Fig. 8(b, d). This means that the model obtained is adequate and there is no doubt for any violation of independence or constant variance assumption (Ref 50, 51).

Fig. 8.
figure 8

(a) Normal probability plot for standardized residuals (b) versus fits for standardize residuals (c) histogram of standardized residuals (d) versus order for standardize residuals

3.1 Confirmation Experiments and Calculation of Confidence Interval for Average Surface Roughness

After the optimum experiment parameters were determined, the reliability of the optimized parameters is experimentally validated in order to obtain reliable experimental results at a 95% confidence interval and 5% significance level. Three validation experiments were performed in milling operations, and the arithmetic average of the results is given in Table 9. Optimal (CVD-coated cutting tool, − 196 °C cryogenic heat treatment, EG+5%BX coolant, 50 m/min cutting speed and 0.03 mm/tooth feed rate) and predicted (CVD-coated cutting tool, − 196 °C cryogenic heat treatment, EG+5%BX coolant, 50 m/min cutting speed and 0.03 mm/tooth feed rate) machining parameter combinations for minimum Ra were compared in Table 9. According to these comparisons, the estimated Ra value was 0.357 μm, while the Ra value experimentally obtained was 0.324 μm.

Table 9. Comparison of the measured and estimated values according to Taguchi design for the Ra value obtained from the milling process of NiTi SMA at different machining parameters

In order to determine the reliability of the optimization process with the Taguchi method, the confidence interval of the estimated values should be determined. For this purpose, Eq 2 was used to obtain the confidence interval (CI) for the estimated average surface roughness (Ra_opt). CI symbols and abbreviations of Eq 2 and 3 are given in Table 10.

$${\text{CI}} = \sqrt {F_{\alpha :1,V2} \cdot V_{e} \cdot \left( {\frac{1}{{n_{{{\text{eff}}}} }} + \frac{1}{r}} \right)}$$
(2)
$$n_{{{\text{eff}}}} = \frac{{T_{\exp } }}{{1 + T_{{{\text{dof}}}} }}$$
(3)
Table 10. Confidence interval (CI) formulas and symbols (Ref 31)

The optimum average surface roughness (Ra_opt = 0.357 µm) estimated by the optimization process is given in Table 9. In the calculation in Eq (2), α = 0.05, Fα:1,V2 = 4.747 (95% F ratio (F table)), and Ra = 0.00053 (Table 8), r = 3, Texp = 27, Tdof = 10 and neff = 2.45. Using Eq 2 and 3, the Ra was calculated as CIRa = ± 0.043.

CI range for estimated average optimum surface roughness at 95% confidence interval and 5% significance level:

$$[{\text{R}}_{{{\text{a\_opt}}}} {-}{\text{CI}}_{{{\text{Ra}}}} ] < {\text{Ra}}_{{{\text{exp}}}} < [{\text{R}}_{{{\text{a\_opt}}}} + {\text{CI}}_{{{\text{Ra}}}} ] \to [0.357{-}0.043] < 0.324 < [0.357 + 0.043] = 0.314 < 0.324 < 0.400.$$

Due to the fact that the average surface roughness value (Raexp = 0.324 μm) obtained as a consequence of the validation experiments is in confidence interval, it was seen that the optimization is successful by Taguchi method at a significance level of 0.05.

Figure 9 shows the comparison of predicted and experimental values for the Ra. It is seen that all experiment results fall in the confidence interval (CI) and prediction interval (PI). This means that the model can be used in estimation of the Ra.

Fig. 9.
figure 9

Comparison of predicted and experimental values for output parameters

4 Conclusions

In the study, the influence of cutting conditions and machining parameters on the Ra of NiTi SMA plates was investigated during face milling operations. The results clearly revealed that feed rate, cutting fluid and deep cryogenic heat treatment are highly effective on Ra. The other experimental and optimization results are listed as follows:

  • According to Taguchi optimization, the most significant parameter on the Ra is the feed rate; it is followed by cutting tool, cutting fluid, cutting speed and cryogenic heat treatment, respectively.

  • The Ra increases with the feed rate, while it decreases with the cutting speed, at especially high values of the cutting speed by about 15%.

  • The Ra value obtained by CVD-coated tools is lower than that of PVD-coated tools; it is approximately 16% lower compared to the uncoated tool.

  • Deep cryogenic heat-treated tools provides an approximately 7% lower mean surface roughness.

  • Usage of the EG and EG+5%BX cutting fluids leads to a 20% decrease in the Ra compared to the dry machining condition.

  • The optimum test parameters for the Ra are the S40T grade cutting tool, − 196 °C cryogenic heat treatment, EG+5%BX cutting fluid, 50 m/min cutting speed, and 0.03 mm/tooth feed.

  • BUE and breakage on the cutting tool occurring especially at high feed rate are responsible for the increase in average surface roughness.