Abstract
Nitrate contamination in aquifers has posed human health under high risk because people still rely on groundwater withdrawn from aquifers as drinking water and running water sources. These days, bioelectrochemical technologies have shown a great number of benefits for nitrate remediation via autotrophic denitrification in groundwater. This study tested the working possibility of a denitrifying biocathode when installed into a simulated aquifer. The reactors were filled with sand and synthetic groundwater at various ratios (10, 50, and 100 %) to clarify the effect of various biocathode states (not-buried, half-buried, and fully buried) on nitrate reduction rate and microbial communities. Decreases in specific nitrate reduction rates were found to be correlated with increases in sand/medium ratios. A specific nitrate reduction rate of 322.6 mg m−2 day−1 was obtained when the biocathode was fully buried in an aquifer. Microbial community analysis revealed slight differences in the microbial communities of biocathodes at various sand/medium ratios. Various coccus- and rod-shaped bacteria were found to contribute to bioelectrochemical denitrification including Thiobacillus spp. and Paracoccus spp. This study demonstrated that the denitrifying biocathode could work effectively in a saturated aquifer and confirmed the feasibility of in situ application of microbial electrochemical denitrification technology.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
Nitrate contamination in aquifers has attracted special attention from environmentalists worldwide because people still rely on groundwater withdrawn from aquifers as drinking water and running water sources. These days, biological technologies have shown many benefits for nitrate remediation via denitrification because of low costs and eco-friendly self-generating catalysts. Both heterotrophic and autotrophic denitrifications have been reported thus far (Rocca et al. 2007). In heterotrophic denitrification, organic substrates, such as acetates, lactates, and glucose, must be supplied into the subsurface of a contaminated site to serve as electron donors for nitrate reduction. However, the supply of organic substrates may activate the growth of other microorganisms in addition to denitrifying bacteria. Autotrophic denitrification with H2 gas as an electron donor has, therefore, been said to be more efficient than heterotrophic denitrification in this respect. As in situ denitrification in groundwater is taken into account, the delivery of H2 gas into an aquifer is quite challenging owing to the low solubility of H2 gas and high installation and operational costs (Ma et al. 2003; Roggy et al. 2004; Agarwal et al. 2005).
Denitrification with a polarized electrode serving as an electron donor has been considered to be more preeminent than conventional heterotrophic or autotrophic denitrification, which requires hydrogen or organic substrates as electron donors. This is because bioelectrochemical denitrification not only stimulates and controls microbial nitrate reduction reactions but also avoids other microbiological activities and growth, which may result in unpreventable and undesirable consequences within the contaminated site. Biocathodes of bioelectrochemical systems have recently been developed for nitrate removal from water sources (Ghafari et al. 2008; Mousavi et al. 2011; Mook et al. 2012; Feng et al. 2013; Huang et al. 2013; Pous et al. 2015). Denitrification carried out by autotrophic bacteria attached to a polarized cathode has been demonstrated widely with synthetic groundwater (Zhao et al. 2011; Zhao et al. 2012; Mousavi et al. 2012; Kondaveeti and Min 2013; Tong et al. 2013; Nguyen et al. 2014). With the aim of in situ application, nitrate removal in the biocathode of a bioelectrochemical system has been thoroughly investigated with continuous influence of real nitrate-contaminated groundwater (Pous et al. 2015). Some other studies have tried to fill the cathode chamber with rod graphite (Puig et al. 2011) or granular graphite (Pous et al. 2015) with an objective to increase conductivity. However, there have been no studies on bioelectrochemical denitrification in aquifers or in soils saturated with groundwater until now, according to our knowledge.
This study aimed to test the working possibility of a denitrifying biocathode polarized at −0.7 V vs. the standard hydrogen electrode (SHE) when inserted into a simulated aquifer saturated with synthetic nitrate-contaminated groundwater. The experiment was also designed to investigate the effect of the proportion of the biocathode buried in a simulated aquifer on denitrification rate and microbial communities. The interactions between electrode and saturated soil and the performance of microorganisms in a liquid phase and solid phase might be totally different. The approach proposed in this report would principally provide us a more clear understanding on how efficient the denitrifying biocathode performed at different depths of burial is. The response of denitrifying microbial communities enriched on bioelectrode to the changes of electrode condition would be also elucidated.
Materials and methods
Reactor configuration and operation
All experimental sets were carried out in duplicate at ambient temperature (25 °C) using a two-chamber bioelectrochemical system (BES) with a working volume of 350 mL per chamber (Supplementary Fig. S1). Both the working electrode and counter electrode were made of graphite felt (4 × 6 × 0.5 cm; GF-S6-06, Amherst, NY, USA) treated by autoclaving with 0.1 M HCl and washing with distilled water. Separators placed between anode and cathode chambers were proton exchange membranes (Nafion 117, DuPont Co., Wilmington, DE, USA) treated by boiling with H2O2 (30 % v/v) and distilled water. Every treatment procedure was repeated consecutively three times. Connection was done by using titanium wire (0.5 mm in diameter). The reference electrode in the cathode chamber was a Ag/AgCl electrode (assumed to be +0.197 V vs. SHE). Coarse sand with an average diameter of 0.58 mm was added to both chambers at four different sand/medium ratios (volume/volume) to simulate a saturated aquifer. The four different ratios including 0, 10, 50, and 100 % represented four conditions of operation involving good circulation, no circulation, half of an electrode submerged in an aquifer, and an electrode totally submerged in an aquifer, respectively. Particle distribution of applied coarse sand analyzed by an LS 13 320 Laser Diffraction Particle Size Analyzer (Beckman Coulter Inc., CA, USA) is shown in Supplementary Fig. S2. Porosity of this sand was determined to be 0.37. A cathode potential of −0.7 V vs. SHE was chosen based on one of our previous studies that suggested that denitrification efficiency was optimal at this cathode potential (Nguyen et al. 2016).
Nitrate-contaminated groundwater applied to BESs was synthesized by adding 50 mg L−1 of NO3 −-N to 50 mM phosphate buffer containing 3.9 g L−1 of NaH2PO4·2H2O and 3.55 g L−1 of Na2HPO4. NaHCO3 (2 g L−1) was supplied as an inorganic carbon source for microorganisms. Anaerobic sludge collected from Suyoung Wastewater Treatment Plant (Suyoung, Busan, South Korea) was used as bacterial inoculum because it usually contains anaerobic consortia which can perform denitrification (Lee et al. 2013; Kondaveeti and Min 2013; Kondaveeti et al. 2014). An abiotic control (no inoculum addition) and a biotic control (open circuit between anode and cathode) were operated simultaneously to compare the results. The headspace of the reactors was purged with argon gas (99.9 %) to achieve the anoxic conditions. The experiment was carried out in batch mode and monitored until the denitrification process was complete. The cathode potential value reported throughout this paper is given in voltage vs. SHE, unless otherwise stated.
Analytical methods and calculations
Nitrate (NO3 −-N) and nitrite (NO2 −-N) concentrations were determined using an ICS-1000 Ion Chromatography System (Dionex, Sunnyvale, CA, USA) featuring a Dionex IonPac AS14 column, an electrochemical conductivity detector, and a suppressor. Column temperature was maintained at 30 °C. Total nitrogen (TN) and ammonium (NH4 +-N) levels were determined using the Humas Kit (Humas Co., Ltd., Daejeon, Korea) according to standard methods for examination of water and wastewater (Franson et al. 1992). Gas-phase products, such as N2, H2, NO, and N2O, that evolved in the headspace of the reactor were analyzed using a gas chromatography system (GC YL6500, Young Lin Instrument, Anyang, Korea) coupled with a thermal conductivity detector maintained at 150 °C.
The coulombic efficiency (CE) of bioreactors was calculated as a ratio between the number of cumulative reducing equivalents and cumulative consumed electric charge according to Eq. (1) as follows:
where eqp is the number of cumulative reducing equivalents that was obtained from Eq (2):
Products included NO2 −, NH4 +, N2 gas, and H2 gas, with conversion factors of 2, 8, 10, and 2 eq/mol, respectively. eq i is the cumulative consumed electric charge, which is calculated by integrating current (I) over the period (t) of cathode polarization using Eq (3). In the case where N2 gas was not totally recovered owing to its being captured by a saturated aquifer (at 50 and 100 %), all nitrate removal was considered to occur through transformation into N2 gas.
where F is the Faraday constant (96485.4 C/mol electron) and data for I was obtained from a potentiostat.
Microbial community analyses
At the end of each experiment, cathode electrodes were taken out of simulated aquifers and the biofilm samples were collected. DNA extraction was performed using a PowerSoil™ DNA isolation kit (Mo Bio Lab., Carlsbad, CA, USA). Polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) was performed as described previously (Nguyen et al. 2014). The PCR primers and PCR conditions are summarized in Supplementary Table S1. Electrophoresis was carried out at 60 °C for 16 h. After electrophoresis was complete, the gel was stained in ethidium bromide for 30 min followed by washing with distilled water for 30 min. The DGGE profile was photographed with a digital camera (Olympus 720 UZ, Olympus Optical Co. Ltd., Japan). DNA bands excised from the DGGE profile were then amplified by PCR using the universal primers Eub 27F (5ʹ-ACG GGC GGT GTG TAC AAG-3ʹ) and Eub 518R (5ʹ-ATT ACC GCG GCT GCT GG-3ʹ). The partial 16S ribosomal ribonucleic acid (rRNA) sequences were then sequenced by Solgent Co., Daejeon, Korea. The phylogenetic identifications of obtained sequences were determined based on 16S rRNA sequence homology by performing a nucleotide Basic Local Alignment Search Tool (BLAST) search at the website of the National Center for Biotechnology Information (Altschul et al. 1990).
Part of a biocathode electrode was pretreated with 2.5 % gluteraldehyde and 1 % osmium tetroxide followed by dehydration with 50, 70, 90, 95, and 100 % ethanol in succession. The pretreated specimens were dried in a desiccator overnight before observation under a field emission-scanning electron microscope (Zeiss FE-SEM SUPRA 25, Germany).
The partial 16S rRNA gene sequences (400–500 bp) obtained from PCR-DGGE analyses were deposited in the GenBank database under accession nos. KT932937–KT932947.
Results and discussion
Denitrification performance depending on the proportion of biocathode buried in simulated aquifer
The proportions of biocathodes buried in sand saturated with synthetic groundwater definitely affect bioelectrochemical denitrification performance (Fig. 1). Indeed, the time spent for complete denitrification varied with the sand/medium ratio in the reactors. Complete denitrification in the reactors with only a liquid phase (0 % sand) took only 15 days, whereas this time was extended to 25 days in the reactors containing 10 % sand (Fig. 1a, b). This may be because of the circulation conditions of the liquid phase in the cathode chamber. At a 0 % sand/medium ratio, the liquid phase was circulated well using a stirring magnetic bar, whereas addition of 10 % sand impeded its operation and the medium was not circulated as a consequence. In both of these cases, the biocathodes were still not buried in sand. When this ratio was increased to 50 % (50 % of biocathode buried in sand), the time for complete denitrification was reduced to 24 days. Only 20 days was required for total nitrate removal in the case where the biocathode was totally buried in sand (100 % sand/medium ratio). This reduction in time does not mean that the denitrification rate increased when these ratios increased from 0 to 100 % because the volume of medium decreased significantly upon increasing the sand/medium ratio.
It was interesting to find that nitrite that occurs as an intermediate of denitrification was detected in all cases except the case of the fully buried biocathode. The nitrite concentration detected during the denitrification varied from 1.1 to 4.7 mg L−1 NO2 −-N. The highest nitrate concentration was observed in the reactors with only a liquid phase where sand was not added. However, no nitrite accumulated until the end of the experiment in all of the cases. Ammonium (10–14 mg L−1 of NH4 +-N) that initially occurred in the reactors is the consequence of inoculum addition. All ammonium ions were removed at the end of each batch test. The removal of ammonium was believed to be due to a non-bioelectrochemical process because the same amount of ammonium was also eliminated in the biotic controls, in which an open circuit between the anode and cathode was maintained (Supplementary Fig. S3). In the biotic controls, nitrate reduction of approximately 10.1–15.5 % by the heterotrophic process, which used the small amount of organic matter available in the inoculum, in addition to ammonium removal of 15.2–20.1 %, resulted in a TN removal efficiency of 26.1–34.6 %. No significant denitrification was recorded in all of the abiotic control reactors, as expressed by the stabilization of nitrate concentration during incubation (Supplementary Fig. S4), which indicated that electrochemical denitrification was not achieved at a cathode potential of −0.7 V. During the operation, when cathode potentials were maintained at −0.7 V, anode potentials fluctuated from 0.6 to 0.8 V (Supplementary Fig. S5).
It was noticeable that no significant amount of nitrite accumulated during denitrification in all reactors, which indicated that direct transformation from nitrate to nitrogen gas was preferable in these cases. Denitrification without accumulation of nitrite was evaluated to be a strong point and a great advantage of this study. This is because nitrite in drinking water is known to be much more toxic than nitrate. The maximum accepted level of nitrite in potable water is 1 mg L−1 of NO2 −-N, whereas the allowance for nitrate is 10 mg L−1 of NO3 −-N according to the World Health Organization (WHO 2011). On the other hand, most of the previous studies on nitrate reduction in BESs indicated accumulation of nitrite at various levels (Virdis et al. 2009; Nguyen et al. 2014; Zhang et al. 2014; Pous et al. 2015).
Dissimilatory nitrate reduction to ammonium (DNRA) was not observed at the selected cathode potential (−0.7 V) in this study although some previous studies reported the occurrence of DNRA during denitrification at such low cathodic potentials (Su et al. 2012; Zhang et al. 2014; Sander et al. 2015; Yu et al. 2015). However, the result coincided well with that of a study on real nitrate-contaminated groundwater, which showed no ammonium production during biocathodic denitrification at −0.703 V (Pous et al. 2015).
The analysis data from the gas chromatograph of the headspace gas at the end of the experiment from the reactors with biocathodes half- or fully buried in sand showed the occurrence of only a small amount of nitrogen gas that was not appropriate to obtain a mass balance with the TN removal. This might be because the forming gases were captured in a saturated aquifer. Based on the present results, it could not be concluded that no gaseous products of nitrate reduction such as N2O and NO were formed in both of these cases (50 and 100 % sand). However, the results from reactors where the biocathode was not buried in sand (0 and 10 % sand) asserted that no N2O or NO gas was detected. On the other hand, our previous studies on the same electrode materials and reactor structure indicated denitrification without formation of these greenhouse gases (Nguyen et al. 2016). Total hydrogen evolutions at the end of the experiments with 0 and 10 % sand (not-buried biocathodes) were similar: 2.2 mmol for 0 % and 2.1 mmol for 10 %. The total hydrogen production in the reactor with the half-buried biocathode (50 % sand) was only 0.7 mmol. Hydrogen was not detected even in the headspace of the reactor with the fully buried biocathode (100 % sand). We cannot definitely assert that hydrogen was not produced in this case because hydrogen could have formed but was instantaneously consumed through hydrogenotrophic denitrification (Zhou et al. 2007; Karanasios et al. 2010; Feng et al. 2013) or possibly captured in a saturated aquifer. Furthermore, previous studies demonstrated that a biocathodic potential of −0.7 V could accelerate hydrogen production (Ra et al. 2008).
Specific nitrate reduction rate depending on the proportion of biocathode buried in simulated aquifer
The decrease in specific nitrate reduction rate was correlated with the increase in the proportion of biocathode buried in a simulated aquifer (Fig. 2). In this study, specific nitrate reduction rate was proposed to obtain an appropriate comparison between the denitrification performances of four different cases because the effective volume of the liquid phase would change with various sand/medium ratios. It was calculated based on the nitrate reduction rate per surface area of the cathodic electrode, which was constant in all reactors and was the main factor deciding denitrification efficiency. The highest specific nitrate reduction rate (831.5 mg m−2 day−1 of NO3 −-N) was achieved in the reactor with the 0 % sand/medium ratio, where the medium was thoroughly circulated. The specific nitrate reduction rate decreased approximately 30 % when 10 % sand was added to the reactors. In fact, under this condition, the cathodic electrode was not buried in sand and the added sand only impeded magnetic bar stirring. This revealed that the circulation plays a significant role in denitrification performance. Contrary to the expectation that an increase in nitrate reduction rate would be correlated with an increase in sand/medium ratio in the 10–100 % range owing to the reduction in overall denitrification time, specific nitrate reduction rate actually decreased when sand/medium ratio increased. A specific nitrate reduction rate of 322.1 mg m−2 day−1 of NO3 −-N was achieved in the 100 % sand/medium ratio, where the biocathode was fully buried in sand saturated with synthetic groundwater. This exhibited retention of 38.7 % denitrification performance in a simulated aquifer compared to the case of the biocathode working in only a liquid phase.
Coulombic efficiency
In this study, total coulombic efficiency at the end of an experiment was one of the parameters used to evaluate the electron consumption performance. Total electron consumption efficiencies varied from 69 to 83 % (Fig. 3). The coulombic efficiencies achieved in this study were slightly lower than those obtained from some previous studies on bioelectrochemical denitrification in water environments (Su et al. 2012; Zhang et al. 2014; Xie et al. 2014), but higher than that from a study on denitrification at an extremely low cathode potential (−0.9 V) (Sander et al. 2015). In this study, electron consumption was not only for denitrification but also partially for hydrogen production. Hydrogen production could be considered as an electron sink during cathodic denitrification. However, hydrogen evolution at the biocathode of denitrification systems might have had a positive impact on nitrate reduction because many previous studies have suggested that H2 would accelerate nitrate reduction through hydrogenotrophic denitrification (Zhou et al. 2007; Karanasios et al. 2010; Feng et al. 2013). Additionally, hydrogen evolution in the headspace of the reactors was believed to be produced biocatalytically because no hydrogen was detected under the same conditions of abiotic controls. Hydrogen production at the graphite felt electrode polarized at −0.7 V in this study coincided well with a previous study that focused on bioelectrochemical hydrogen production (Ra et al. 2008).
It seems that the efficacy of electron consumption in the reactors where the biocathode was not buried in sand (at sand ratios of 0 and 10 %) is higher than that where the cathode was inserted into sand (at sand ratios of 50 and 100 %) (Fig. 3). As a matter of fact, those lower coulombic efficiencies may be due to the loss of H2, which might have been trapped in the simulated aquifer. However, coulombic efficiencies for H2 production were only from 2.6 to 2.9 %, constituting 3.1 to 3.6 % of total coulombic efficiencies. This means that electron consumption for hydrogen production was not a substantial contributor to coulombic efficiency. Thus, in the cases of the half-buried and fully buried biocathodes (50 and 100 % of sand ratio), the calculated coulombic efficiencies reflect a high level of electron loss when the electrode worked in saturated aquifers. This might be due to the contact between the electrode and sand.
Microbial community catalyzing denitrification
PCR-DGGE results proved that there are slight differences between microbial communities on not-buried and buried biocathodes (Fig. 4). The prominent 11 DNA bands observed on DGGE profiles were excised and sequenced to determine the phylotypic levels. These obtained sequences were compared to the most similar sequences of cultured and uncultured microorganisms deposited in GenBank (Table 1). Phylotypic determination of these sequences indicated the dominance of Betaproteobacteria among bacterial communities (6/11 obtained sequences). The absence of bands in the case of abiotic control revealed that the reactors were successfully maintained in abiotic conditions.
Three bands including S7, S9, and S11 were observed to have the highest intensity, suggesting that the biocathodic denitrification was mainly attributed to Thiobacillus denitrificans (94 % similarity), T. thioparus (91 % similarity), and Paracoccus denitrificans (94 % similarity), respectively. Those bacteria are well known as autotrophic denitrifiers (Carlson and Ingraham 1983; Claus and Kutzner 1985) and were recently found to be the dominant denitrifiers in bioelectrochemical denitrification systems (Vilar-Sanz et al. 2013; Xie et al. 2014). Direct electron uptake by T. denitrificans has also been discovered (Yu et al. 2015). These findings are in good agreement with the scanning electron microscopic (SEM) observation of the cathode electrode (Fig. 5). SEM photographs revealed the attachment of some rod-shaped and coccus-shaped bacterial cells on the cathodic electrode.
It was interesting that band S8, which shared 91 % sequence similarity with an uncultured bacterium from cathode-suspended biomass of the bioelectrochemical denitrification system (Lee et al. 2013), was only detected on the biocathode suspended in medium (0 and 10 % of sand ratio). Alternatively, band S6, which shared 97 % sequence similarity with a betaproteobacterium, Simplicispira sp. RSG39, was only found on the electrode buried in sand. In addition, the sequence of this band also represented 99 % identity to an uncultured Simplicispira sp. clone, MFC-1-L9, that was found on the anodic biofilm of a microbial fuel cell (unpublished paper, GenBank accession no. JX944522), suggesting that this bacterium may possess electrochemically active properties.
Other bands, such as S1, S2, S3, S4, S5, and S10, were detected in all cases, even in the biotic control with lower band intensity. Band S1 shared 99 % similarity with an uncultured bacterium discovered in a microbial electrolysis cell biocathode (Croese et al. 2014). It also shared 99 % sequence similarity with an alphaproteobacterium, Mesorhizobium sp. ADC-19B. Bands S4 and S10 showed high sequence similarity to uncultured bacteria that were detected in sludge systems for ammonium removal via the combined nitrite nitrification and electrochemical denitrification process (Wang et al. 2014). These two bands may be assigned to the agent for ammonium removal in most reactors of this study.
Conclusion
This study showed that the first trial for testing denitrification performance of a biocathode buried in a simulated aquifer saturated with synthetic nitrate-contaminated groundwater was successful. Even though only 38.7 % of the specific nitrate reduction rate of the biocathode was retained in the case of the fully buried biocathode compared to that of the not-buried biocathode working with only a liquid phase, the results indicated the feasibility of in situ application of a graphite felt biocathode. Throughout the sand/medium ratio tests, the significant role of circulation was disclosed. A static state of the liquid phase could retard nitrate reduction by 30 % compared to the case with good circulation. In practical applications for groundwater remediation, this limitation could be attenuated by the natural dynamic flow of groundwater. The bioelectrochemical denitrifying microorganisms could grow and perform well in saturated aquifers. However, the state of the biocathode (not-buried or buried in aquifers) also impacts the growth of some specific bacteria slightly. More detailed studies on scaling up of this system should be taken into account before this technology is brought to field application.
Abbreviations
- BES:
-
Bioelectrochemical system
- SHE:
-
Standard hydrogen electrode
- TN:
-
Total nitrogen
- CE:
-
Coulombic efficiency
- PCR-DGGE:
-
Polymerase chain reaction-denaturing gradient gel electrophoresis
- rRNA:
-
Ribosomal ribonucleic acid
- BLAST:
-
Basic Local Alignment Search Tool
- DNRA:
-
Dissimilatory nitrate reduction to ammonia
- SEM:
-
Scanning electron microscopy
References
Agarwal N, Semmens MJ, Novak PJ, Hozalski RM (2005) Zone of influence of a gas permeable membrane system for delivery of gases to groundwater. Water Resour Res 41:1–10. doi:10.1029/2004WR003594
Altschul SF, Gish W, Miller W et al (1990) Basic local alignment search tool. J Mol Biol 215:403–410
Carlson CA, Ingraham JL (1983) Comparison of denitrification by Pseudomonas stutzeri, Pseudomonas aeruginosa, and Paracoccus denitrificans. Appl Envir Microbiol 45:1247–1253
Claus G, Kutzner H (1985) Physiology and kinetics of autotrophic denitrification by Thiobacillus denitrificans. Appl Microbiol Biotechnol. doi: 10.1007/BF00252031.
Croese E, Jeremiasse AW, Marshall IPG et al (2014) Influence of setup and carbon source on the bacterial community of biocathodes in microbial electrolysis cells. Enzyme Microb Technol 61–62:67–75. doi:10.1016/j.enzmictec.2014.04.019
Feng H, Huang B, Zou Y et al (2013) The effect of carbon sources on nitrogen removal performance in bioelectrochemical systems. Bioresour Technol 128:565–570. doi:10.1016/j.biortech.2012.11.004
Franson MAH, Greenberg AE, Clesceri LS, Eaton AD (1992) Standard methods for the examination of water and wastewater. American Public Health Association, Washinton
Ghafari S, Hasan M, Aroua MK (2008) Bio-electrochemical removal of nitrate from water and wastewater—a review. Bioresour Technol 99:3965–3974. doi:10.1016/j.biortech.2007.05.026
Huang B, Feng H, Wang M et al (2013) The effect of C/N ratio on nitrogen removal in a bioelectrochemical system. Bioresour Technol 132:91–98. doi:10.1016/j.biortech.2012.12.192
Karanasios KA, Vasiliadou IA, Pavlou S, Vayenas DV (2010) Hydrogenotrophic denitrification of potable water: a review. J Hazard Mater 180:20–37. doi:10.1016/j.jhazmat.2010.04.090
Kondaveeti S, Min B (2013) Nitrate reduction with biotic and abiotic cathodes at various cell voltages in bioelectrochemical denitrification system. Bioprocess Biosyst Eng 36:231–238. doi:10.1007/s00449-012-0779-0
Kondaveeti S, Lee S-H, Park H-D, Min B (2014) Bacterial communities in a bioelectrochemical denitrification system: the effects of supplemental electron acceptors. Water Res 51:25–36. doi:10.1016/j.watres.2013.12.023
Lee SH, Kondaveeti S, Min B, Park HD (2013) Enrichment of Clostridia during the operation of an external-powered bio-electrochemical denitrification system. Process Biochem 48:306–311. doi:10.1016/j.procbio.2012.11.020
Ma X, Novak PJ, Clapp LW et al (2003) Evaluation of polyethylene hollow-fiber membranes for hydrogen delivery to support reductive dechlorination in a soil column. Water Res 37:2905–2918. doi:10.1016/S0043-1354(03)00111-8
Mook WT, Aroua MKT, Chakrabarti MH et al (2012) A review on the effect of bio-electrodes on denitrification and organic matter removal processes in bio-electrochemical systems. J Ind Eng Chem 19:1–13. doi:10.1016/j.jiec.2012.07.004
Mousavi SAR, Ibrahim S, Aroua MK, Ghafari S (2011) Bio-electrochemical denitrification -A review.
Mousavi S, Ibrahim S, Aroua MK, Ghafari S (2012) Development of nitrate elimination by autohydrogenotrophic bacteria in bio-electrochemical reactors—a review. Biochem Eng J 67:251–264. doi:10.1016/j.bej.2012.04.016
Nguyen VK, Hong S, Park Y et al (2014) Autotrophic denitrification performance and bacterial community at biocathodes of bioelectrochemical systems with either abiotic or biotic anodes. J Biosci Bioeng 119:180–187. doi:10.1016/j.jbiosc.2014.06.016
Nguyen VK, Park Y, Yang H, et al (2016) Effect of the cathode potential and sulfate ions on nitrate reduction in a microbial electrochemical denitrification system. J Ind Microbiol Biotechnol. doi:10.1007/s10295-016-1762-6
Pous N, Puig S, Dolors Balaguer M, Colprim J (2015) Cathode potential and anode electron donor evaluation for a suitable treatment of nitrate-contaminated groundwater in bioelectrochemical systems. Chem Eng J 263:151–159. doi:10.1016/j.cej.2014.11.002
Puig S, Serra M, Vilar-Sanz A et al (2011) Autotrophic nitrite removal in the cathode of microbial fuel cells. Bioresour Technol 102:4462–4467. doi:10.1016/j.biortech.2010.12.100
Ra R, Aw J, Hvm H, Cjn B (2008) Hydrogen production with a microbial biocathode. Env Sci Technol 42:629–634
Rocca CD, Belgiorno V, Meriç S (2007) Heterotrophic/autotrophic denitrification (HAD) of drinking water: prospective use for permeable reactive barrier. Desalination 210:194–204. doi:10.1016/j.desal.2006.05.044
Roggy DK, Novak PJ, Hozalski RM, et al (2004) Membrane Gas Transfer for Groundwater Remediation: Chemical and Biological Fouling.
Sander EM, Virdis B, Freguia S (2015) Dissimilatory nitrate reduction to ammonium as an electron sink during cathodic denitrification. RSC Adv 5:86572–86577. doi:10.1039/C5RA19241B
Su W, Zhang L, Li D et al (2012) Dissimilatory nitrate reduction by Pseudomonas alcaliphila with an electrode as the sole electron donor. Biotechnol Bioeng 109:2904–2910. doi:10.1002/bit.24554
Tong S, Zhang B, Feng C et al (2013) Characteristics of heterotrophic/biofilm-electrode autotrophic denitrification for nitrate removal from groundwater. Bioresour Technol 148:121–127. doi:10.1016/j.biortech.2013.08.146
Vilar-Sanz A, Puig S, García-Lledó A et al (2013) Denitrifying bacterial communities affect current production and nitrous oxide accumulation in a microbial fuel cell. PLoS One 8:e63460. doi:10.1371/journal.pone.0063460
Virdis B, Rabaey K, Yuan Z et al (2009) Electron fluxes in a microbial fuel cell performing carbon and nitrogen removal. Environ Sci Technol 43:5144–5149. doi:10.1021/es8036302
Wang H, Zhou Y, Yuan Q et al (2014) Bacteria morphology and diversity of the combined autotrophic nitritation and sulfur-carbon three-dimensional-electrode denitrification process. J Environ Sci Health A Tox Hazard Subst Environ Eng 49:39–51. doi:10.1080/10934529.2013.824296
WHO (2011) Nitrate and nitrite in drinking-water. Background document for development of WHO Guidelines for Drinking-water Quality
Xie D, Yu H, Li C et al (2014) Competitive microbial reduction of perchlorate and nitrate with a cathode directly serving as the electron donor. Electrochim Acta 133:217–223. doi:10.1016/j.electacta.2014.04.016
Yu L, Yuan Y, Chen S et al (2015) Direct uptake of electrode electrons for autotrophic denitrification by Thiobacillus denitrificans. Electrochem Commun 60:126–130. doi:10.1016/j.elecom.2015.08.025
Zhang W, Zhang Y, Su W et al (2014) Effects of cathode potentials and nitrate concentrations on dissimilatory nitrate reductions by Pseudomonas alcaliphila in bioelectrochemical systems. J Environ Sci (China) 26:885–891. doi:10.1016/S1001-0742(13)60460-X
Zhao Y, Feng C, Wang Q et al (2011) Nitrate removal from groundwater by cooperating heterotrophic with autotrophic denitrification in a biofilm-electrode reactor. J Hazard Mater 192:1033–1039. doi:10.1016/j.jhazmat.2011.06.008
Zhao Y, Zhang B, Feng C et al (2012) Behavior of autotrophic denitrification and heterotrophic denitrification in an intensified biofilm-electrode reactor for nitrate-contaminated drinking water treatment. Bioresour Technol 107:159–165. doi:10.1016/j.biortech.2011.12.118
Zhou M, Fu W, Gu H, Lei L (2007) Nitrate removal from groundwater by a novel three-dimensional electrode biofilm reactor. Electrochim Acta 52:6052–6059. doi:10.1016/j.electacta.2007.03.064
Acknowledgments
This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT, and Future Planning (NRF-2015R1A2A1A15054528) and the Brain Korea 21 Plus Project in the Division of Creative Low Impact Development and Management for Ocean Port City Infrastructures (21A20132012304). The authors would like to thank Mr. Donghyun Lee at the Laboratory for Environmental Microbiology and Energy for his contribution to the abstract improvement. The assistance of Mr. Chaeho Im at the Bioenergy and Bioprocess Laboratory, Department of Polymer Science and Chemical Engineering, in gas chromatography operation is also acknowledged.
Author information
Authors and Affiliations
Corresponding author
Additional information
Responsible editor: Bingcai Pan
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(DOCX 383 kb)
Rights and permissions
About this article
Cite this article
Nguyen, V.K., Park, Y., Yu, J. et al. Bioelectrochemical denitrification on biocathode buried in simulated aquifer saturated with nitrate-contaminated groundwater. Environ Sci Pollut Res 23, 15443–15451 (2016). https://doi.org/10.1007/s11356-016-6709-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11356-016-6709-y