Abstract
The development of methods for lead ion determination in various biological and environmental samples is both necessary and challenging. In this context, considering the properties of both SBA-15 and MCM-41 mesoporous materials and the role of NH2-functional groups grafted on the silica surface (SBA-15-NH2 and MCM-41-NH2), the aim of the study was to investigate the electrochemical detection of Pb2+ by means of silica-modified glassy carbon electrodes (GCEs). The square wave anodic stripping voltammetry (SWASV) was used to characterize the modified electrodes with four different samples of ordered mesoporous silica (OMS) powders, mentioned above. Additionally, scanning electron microscopy (SEM) was used to characterize these modifiers. Pb2+ exhibits a well-defined oxidation peak (around − 0.5 V vs. Ag/AgCl/KClsat) and high peak current at either bare or OMS-modified glassy carbon electrodes, but the best response was recorded in the case of GC/SBA-15-NH2-modified electrode in 0.1 M acetate buffer. The performance of the prepared electrodes is highlighted by good analytical parameters (satisfies the requirements of low cost and rapid results), which recommends them to be used for real sample analysis.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
1 Introduction
Heavy metals are environmental priority pollutants, especially in developing countries with rapid industrialization of the economy (Chu et al. 2019). Many heavy metal ions (HMIs) are known as toxic and carcinogenic. HMIs of particular concern such as Cd2+ (Awual et al. 2018), Cu2+ (Cao et al. 2013), Hg2+ (Hazra et al. 2019), Ni2+ (Li et al. 2013), Pb2+ (Kang et al. 2017), and their compounds are widely used in industries and, unlike organic contaminants, are not biodegradable leading to contamination of natural water, tending to accumulate in living organisms and threatening the health of human beings. It is worth mentioning that Cd2+, Cu2+, Hg2+, and Pb2+ are the most common HMIs present in our daily lives. The importance of controlling the level of environmental pollutants in natural waterways and potable water has generated increasing interest in the development of novel sensors for the detection of HMIs such as lead ions.
Lead has several uses, such as in accumulators, ammunitions, piping, paints, anti-radiation screens, and tin-based welding alloys, as well as the industrial processing of other metals, for example silver, gold, and bismuth (Sadiq and Alan 1997). A medical condition caused by elevated levels of the lead metal in the blood is lead poisoning. The detection of Pb2+ becomes an important concern of the research, because humans accumulate elevated levels of lead in the blood stream, which affect seriously their one health (kidney, liver, cardiovascular, brain functions, reproductive and immune system) (Afkhami et al. 2013) and its detection becomes an important concern of the research. Therefore, this led to increasing demands to develop reliable methods that can rapidly detect Pb2+ in a sensitive and selective manner (Awual et al. 2018).
For the detection of trace amount of lead, many standardized methods have been used, such as atomic absorption spectrometry (AAS) (Fayazi et al. 2016), atomic fluorescence spectrometry (AFS), and inductively coupled plasma mass spectroscopy (ICP-MS) (Sánchez Trujillo et al. 2013) or atomic emission spectrometry (ICP-AES) (Wuilloud et al. 2002). However, electrochemical methods are often preferred due to their simplicity, efficiency, high selectivity, excellent sensitivity, short analysis time, portability, and low cost (Cunci and Cabrera 2011).
In order to determine Pb2+, the electrochemical properties of various modified glassy carbon electrodes were investigated by other authors and previously reported (Xiong et al. 2013; Zhou et al. 2016). Among the modifiers, silica-based materials deserve special attention for a number of reasons. The siliceous mesoporous materials, mainly SBA-15 and MCM-41, have attracted the scientists’ interest due to their large specific surface areas (200–1200 m2 g−1), ordered structure (El-Salamony et al. 2017), inert framework, non-toxicity (Hudson et al. 2008), and hydro/thermal stability (Mesa et al. 2008), which allow them to be used as catalyst and enzyme supports (Pitzalis et al. 2017), as well as adsorbents (Llewellyn 2014; Lachowicz et al. 2019), sensing devices (Buica et al. 2013), or drug delivery systems (Nairi et al. 2017; Wang 2009). Recently, we used OMS-modified glassy carbon electrodes (GCEs) for the electrochemical detection of malachite green (MG) (Sacara et al. 2017) and Cd2+ ions (Sacara et al. 2019). It was found that OMS modification of GCE to obtain GC/OMS/Nafion significantly improved the sensitivity and the detection limits of either MG or Cd2+ respect to GC/Nafion electrodes.
This work is aiming to establish the optimal conditions for the analysis of Pb2+ by square wave anodic stripping voltammetry (SWASV), using glassy carbon electrodes drop-casted with a composite layer containing one of four different types of OMS (pristine SBA-15 and MCM-41 and amino-functionalized silica (SBA-15-NH2 and MCM-41-NH2) (McManamon et al. 2012; Guo et al. 2015), immobilized in an ion-exchange polymer (Nafion).
2 Experimental Section
2.1 Apparatus
The electrochemical experiments were conducted using an Eco Chemie Metrohm Autolab PGSTAT302N 30 V/2 A (Utrecht, The Netherlands) connected to a PC for control and data storage. A classical three-electrode cell (10 mL volume, Princeton Applied Research, USA) containing a glassy carbon (GC) electrode (inner diameter of 3 mm, polyether ether ketone isolation, ALS Ltd., Japan) as the working electrode, a silver/silver chloride electrode in saturated potassium chloride solution (Ag/AgCl, KClsat) as reference electrode, and a platinum plate (Radiometer Analytical M241Pt, USA) as counter electrode was employed for the electrochemical studies. The pH measurements were made using a glass electrode connected to a Hanna Instrument HI2002 pH meter.
For morphological analysis, the samples deposited on glassy carbon electrodes were coated with a 10-nm gold layer and performed using a Hitachi SU8230 High Resolution Scanning Electron Microscope (SEM) equipped with a cold field emission gun.
Standard measurements by inductively coupled plasma optical emission spectrometry (ICP-OES) were performed with a Spectro CirosCCD (Spectro Kleve, Germany) apparatus.
2.2 Reagents
All reagents were of analytical grades and used without further purification. Deionized water was used to prepare all solutions. Working solutions were freshly prepared before use by diluting stock solutions. Tetraethoxysilane (TEOS, 98%), hexadecyltrimethylammonium bromide (CTAB, > 99%), Pluronic copolymer 123 (EO20-PO70EO20), sodium hydroxide, anhydrous toluene (99.8%), 3-aminopropyltriethoxysilane (APTES, > 98%), triethylamine (> 99%), and hydrochloride acid (37%) were purchased from Sigma-Aldrich (Milan, Italy). A 0.1 mol L−1 acetate buffer solution with pH 4.4 was prepared by mixing C2H3NaO2 with CH3COOH (Merck, Darmstadt, Germany). Sodium dodecyl sulfate (SDS) and Nafion (5% wt. ethanol) were purchased from Sigma-Aldrich (Milan, Italy). ZnSO4∙7H2O (Sigma-Aldrich, Milan, Italy), Cd(CH3COO)2·2H2O and Pb(CH3COO)2·3H2O were purchased from Reactivul Bucuresti, Romania.
2.3 Synthesis of OMS Samples
MCM-41, MCM-41-NH2, SBA-15, and SBA-15-NH2 samples were synthesized according to a previously reported procedure and their physico-chemical characterisation (TEM, SAXS, TGA, etc) are described thoroughly by Salis et al. (2010, 2016).
2.4 Preparation of the Modified GC Electrode
Prior to any modification, the GC electrode was polished to a mirror-like surface on a piece of felt with alumina slurry (0.3 nm), rinsed thoroughly with deionized water after each step, then washed successively with ethanol and deionized water for 2 min in an ultrasound bath separately and dried. In order to obtain a homogeneous suspension and to prevent precipitation and aggregation of silica particles, 1% of SDS was used to prepare 2.0-mg/mL OMS suspensions. The cleaned GCE surfaces were covered by drop-casting with 5.0 μL suspension and dried at room temperature (RT). To improve the stability of samples, 5.0 μL of Nafion 2.5% (prepared by dilution with ethanol from a 5% wt. solution) was added on the electrode surface. The coating was allowed to dry at RT for 20 min. Before use, the electrodes were equilibrated for 10 min in the supporting electrolyte solution. The GC/Nafion electrode was compared with all other electrodes being the reference. The investigated GCEs were Nafion-modified with or without OMS (namely GC/Nafion; GC/SBA-15/Nafion; GC/SBA-15-NH2/Nafion; GC/MCM-41/Nafion; GC/MCM-41-NH2/Nafion).
2.5 Electrochemical Measurements
All experiments were performed at room temperature (RT, 22 ± 2 °C), and by pumping argon gas in solution, the dissolved oxygen was removed. All potentials reported in this paper were referenced to Ag/AgCl (in saturated KCl solution). SWASV was used to study the electrochemical behavior of Pb2+.
SWASV conditions were as follows: potential range, from − 0.7 V to − 0.4 V vs. Ag/AgCl, KClsat; frequency, 25 Hz; amplitude, 0.07 V; and step potential, 0.005 V; after equilibration, 5 s; electrode conditioning, 0 V vs. Ag/AgCl, KClsat; duration, 60 s; deposition time, 120 s; deposition potential, − 1 V vs. Ag/AgCl, KClsat.
3 Results and Discussion
3.1 Electrochemical Determination of Pb2+
As a highly sensitive and low detection limit electrochemical method, SWASV was used to detect the Pb2+ ions. The role of –NH2 functional groups grafted on the silica surface on the electrochemical behavior of the modified electrodes was also investigated. Starting from the literature data (Xiong et al. 2013), 0.1 M acetate buffer was chosen as electrolyte.
3.2 Influence of Silica Type
The results presented in Fig. 1 are in line with those obtained for the determination of surface area of the working electrode (GC). A difference of the Pb2+ signal strength between the SWASV represented in Fig. 1a (GC/Nafion, GC/SBA-15/Nafion, and GC/SBA-15-NH2/Nafion) and Fig. 1b (GC/Nafion, GC/MCM-41/Nafion, and GC/MCM-41-NH2/Nafion) is seen. Besides the unique properties of OMS, the highest Ip and the less positive Ep result from their large surface areas.
Figure 2 a shows the SWASV of the GC/SBA-15-NH2/Nafion electrode in 0.1 M acetate buffer (pH 4.4) containing various concentrations of Pb2+ (0.5–6.0 μM), and from Fig. 2b, it could be seen that the peak current height varied linearly with Pb2+ concentration in the same range. In Table 1, the electroanalytical parameters of the various GC modified electrodes with mesoporous silica and Nafion are presented, and it can be seen that the best analytical performance belongs to the electrode with GC/SBA-15-NH2/Nafion, where the calibration curve and correlation coefficient for Pb2+ was: Ipeak (μA) = 1.33 C (μM) + 4.81 (R = 0.9983 for 12 experimental points).
3.3 Calibration Curves and Electroanalytical Parameters
Calibration curves for the silica-modified GC electrodes were drawn for all silica-modified electrodes by plotting the peak current, Ipeak, versus the lead ion concentration (Fig. 3), and the corresponding electroanalytical parameters are listed in Table 1.
In Table 1, the detection limits (DLs) were calculated for a signal-to-noise ratio of 3, using the formula DL = 3SD/slope, where the slope and standard deviation (SD) correspond to the parameters of the fitting equation.
It can be seen that all silica powders immobilized on GC surface have a good impact on metal ion detection due to their good adsorption properties.
Despite their smaller specific surface area, silica powders SBA-15 (SBET = 880 m2/g) and SBA-15-NH2 (SBET = 373 m2/g) were proven to perform more than MCM-41 (SBET = 1061 m2/g) and MCM-41-NH2 (SBET = 894 m2/g), in which the detection limit of the electrodes is concerned, suggesting that the surface area is not the only characteristic of the silica powders that should be taken into consideration. The best results were obtained with the GC/SBA-15-NH2/Nafion electrode (lowest detection limit and highest sensitivity). The presence of the –NH2 group has a beneficial effect on electrodes’ performances, being probable that amino groups bind metal ions, thus increasing their concentration at the interface during the accumulation step (Dai et al. 2014) and hence lowering the detection limit. Moreover, considering that the SBA-15 structures are synthesized from non-ionic templates and show thicker walls, they usually are more stable than the MCM-41 structure. Similar results were previously obtained for Cd2+ detection through OMS-modified GCEs. In that case, besides an effect due to surface area and surface functionalization, an additional effect due to solution pH was observed. Indeed, while at pH 4.4 the GC modified with MCM-41 (the material with the highest surface area) gave the highest sensitivity; at pH 6, this was obtained with the SBA-15-NH2-modified electrode. It is hence likely that the GCE performances, expressed by the slopes of the electrochemical calibration curves, are the outcome of several contrasting effects involving OMS surface area and functionalization, as well as metal ion species, the nature, and the pH values of buffer solution (Sacara et al. 2019).
3.4 Morpho-structural Analysis
In Fig. 4, the SEM micrographs of GC electrodes modified with amino-functionalized OMS (SBA-15-NH2 Fig. 4a, and MCM-41-NH2 Fig. 4b) and Nafion are presented.
It is seen that GC/SBA-15-NH2/Nafion (Fig. 4a) has a looser structure than GC/MCM-41-NH2/Nafion (Fig. 4b) allowing an easier accumulation of the Pb2+ ions in the pores and channels of the coating.
3.5 Selectivity and Interference Studies
In order to evaluate the possible interference of other HMIs with the detection of lead, two heavy metal ions, Zn2+ and Cd2+, were tested. Figure 5 presents the SWASVs at the bare GCE (Fig. 5a), the GCE/SBA-15-NH2/Nafion (Fig. 5b) by using the concentration of 50 μM of the three heavy metal ions. Figure 5 c displays SWASVs at GCE/SBA-15-NH2/Nafion by peak currents of Pb2+ which increase linearly with concentrations in the range of 50–300 μM and peak currents of Cd2+ maintaining constant with concentration of 50 μM. All the electrodes were tested in 0.1 M acetate buffer (pH 4.4).
Three distinct and well-separated peaks were obtained for Zn2+, Cd2+, and Pb2+, indicating that no interference exists in the case of these ions.
3.6 Repeatability and Reproducibility of GC/SBA-15-NH2/Nafion Electrode
Repeatability and reproducibility were tested by SWASV and expressed for current peak intensities. Repeatability was found to be 4% for a single electrode GC/SBA-15-NH2/Nafion with four consecutive measurements and reproducibility (RSD%) was found to be 5.1% for five electrodes following identical measurement procedures.
3.7 Real Sample Analysis
Determination of Pb2+ concentration was performed by SWASV, with GC/SBA-15-NH2/Nafion electrode from a natural water sample (pH 5) situated in Sălaj region, Romania. The measurements were repeated three times and the peak height values mediated, then interpolated on a premade calibration curve for the estimation of the unknown concentration. Working conditions (see Fig. 1) were the same as for all SWASVs measured before, and the calibration curve was done in 0.5–6 μM Pb2+ concentration range, at pH 4.4. In Table 2, the results of the standard ICP-OES method compared with the value obtained with GC/SBA-15-NH2/Nafion-modified electrode are presented. As can be seen, the obtained results by both methods are in good agreement.
4 Conclusions
Ordered mesoporous silica immobilized on GCE improves the electroanalytical parameters of GCEs/Nafion due to their large surface area and to their adsorption ability.
The electrodes exhibited a linear response over a wide concentration range with a selective response to lead ion, and they are easy to prepare and is a rapid method of determination.
The analytical parameters of the prepared electrodes determined by square wave anodic stripping voltammetry were very promising, recommending the use of the modified electrode for determination of trace amount of Pb2+ ions in real sample analysis.
References
Afkhami, A., Ghaedi, H., Madrakian, T., & Rezaeivala, M. (2013). Highly sensitive simultaneous electrochemical determination of trace amounts of Pb(II) and Cd(II) using a carbon paste electrode modified with multi-walled carbon nanotubes and a newly synthesized Schiff base. Electrochimica Acta, 89, 377–386.
Awual, M. R., Khraisheh, M., Alharthi, N. H., Luqman, M., Islam, A., & Karim, M. R. (2018). Efficient detection and adsorption of cadmium(II) ions using innovative nano-composite materials. Chemical Engineering Journal, 343, 118–127.
Buica, G. O., Ungureanu, E. M., Birzan, L., Razus, A. C., & Mandoc, L. R. (2013). Voltammetric sensing of lead and cadmium using poly(4-azulen-1-yl-2,6- bis(2-thienyl)pyridine) complexing films. Journal of Electroanalytical Chemistry, 693, 67–72.
Cao, Y., Ding, L., Hu, W., Wang, L., & Fang, Y. (2013). Selective sensing of copper and mercury ions with pyrene functionalized fluorescent film sensor containing a hydrophilic spacer. Applied Surface Science, 273, 542–548.
Chu, Y., Gao, F., Gao, F., & Wang, Q. (2019). Enhanced stripping voltammetric response of Hg2+, Cu2+, Pb2+ and Cd2+ by ZIF-8 and its electrochemical analytical application. Journal of Electroanalytical Chemistry, 835, 293–300.
Cunci, L., & Cabrera, C. R. (2011). Preparation and electrochemistry of boron-doped diamond nanoparticles on glassy carbon electrodes. Electrochemical and Solid-State Letters, 14, K17–K19.
Dai, X., Qiu, F., Zhou, X., Long, Y., Li, W., & Tu, W. Y. (2014). Amino-functionalized mesoporous silica modified glassy carbon electrode for ultra-trace copper(II) determination. Analytica Chimica Acta, 848, 25–31.
El-Salamony, R. A., Gobara, H. M., & Younis, S. A. (2017). Potential application of MoO3 loaded SBA-15 photo-catalyst for removal of multiple organic pollutants from water environment. Journal of Water Process Engineering., 18, 102–112.
Fayazi, M., Taher, M. A., Afzali, D., Mostafavi, A., & Ghanei-Motlagh, M. (2016). Synthesis and application of novel ion-imprinted polymer coated magnetic multi-walled carbon nanotubes for selective solid phase extraction of lead(II) ions. Materials Science and Engineering: C, 60, 365–373.
Guo, K., Han, F., Arslan, Z., McComb, J., Mao, X., Zhang, R., Sudarson, S., & Yu, H. (2015). Adsorption of Cs from water on surface-modified MCM-41 mesosilicate. Water, Air, and Soil Pollution, 226, 288–297.
Hazra, S., Bodhak, C., Chowdhury, S., Sanyal, D., Mandal, S., Chattopadhyay, K., et al. (2019). A novel tryptamine-appended rhodamine-based chemosensor for selective detection of Hg2+ present in aqueous medium and its biological applications. Analytical and Bioanalytical Chemistry, 411, 1143–1157.
Hudson, S. P., Padera, R. F., Langer, R., & Kohane, D. S. (2008). The biocompatibility of mesoporous silicates. Biomaterials, 29, 4045–4055.
Kang, W., Pei, X., Rusinek, C. A., Bange, A., Haynes, E. N., Heineman, W. R., & Papautsky, I. (2017). Determination of lead with a copper-based electrochemical sensor. Analytical Chemistry, 89, 3345–3352.
Lachowicz, J. I., Delpiano, G. R., Zanda, D., Piludu, M., Sanjust, E., Monduzzi, M., & Salis, A. (2019). Adsorption of Cu2+ and Zn2+ on SBA-15 mesoporous silica functionalized with triethylentetramine chelating agent. Journal of Environmental Chemical Engineering, 7, 103205. https://doi.org/10.1016/j.jece.2019.103205.
Li, Z., Teng, T. T., Alkarkhi, A. F. M., Rafatullah, M., & Low, L. W. (2013). Chemical modification of imperata cylindrica leaf powder for heavy metal ion adsorption. Water, Air, & Soil Pollution, 224, 1505–1519.
Llewellyn, P. (2014). Adsorption by ordered mesoporous materials. Adsorption by powders and porous solids, Marseille; pp. 529–564.
Mesa, M., Hoyos, L., & Sierra, L. (2008). Effect of the porosity and hydrothermal stability of SBA-16 type mesoporous silica on the characteristics of their carbon replicas. Studies in Surface Science and Catalysis, 174, 361–364.
McManamon, C., Burke, A. M., Holmes, J. D., & Morris, M. A. (2012). Amine-functionalised SBA-15 of tailored pore size for heavy metal adsorption. Journal of Colloid and Interface Science, 369, 330–337.
Nairi, V., Medda, L., Monduzzi, M., & Salis, A. (2017). Adsorption and release of ampicillin antibiotic from ordered mesoporous silica. Journal of Colloid and Interface Science, 497, 217–225.
Pitzalis, F., Monduzzi, M., & Salis, A. (2017). A bienzymatic biocatalyst constituted by glucose oxidase and horseradish peroxidase immobilized on ordered mesoporous silica. Microporous and Mesoporous Materials, 241, 145–154.
Sacara, A. M., Nairi, V., Salis, A., Turdean, G. L., & Muresan, L. M. (2017). Silica-modified electrodes for electrochemical detection of malachite green. Electroanalysis., 29, 2602–2609.
Sacara, A. M., Pitzalis, F., Salis, A., Turdean, G. L., & Muresan, L. M. (2019). Glassy carbon electrodes modified with ordered mesoporous silica for the electrochemical detection of cadmium ions. ACS Omega., 4, 1410–1415.
Sadiq, M., & Alam, I. (1997). Lead contamination of groundwater in an industrial complex. Water, Air, and Soil Pollution, 98, 167–177.
Salis, A., Parsons, D. F., Boström, M., Medda, L., Barse, B., Ninham, B. W., & Monduzzi, M. (2010). Ion specific surface charge density of SBA-15 mesoporous silica. Langmuir., 26, 2484–2490.
Salis, A., Fanti, M., Medda, L., Nairi, V., Cugia, F., Piludu, M., Sogos, V., & Monduzzi, M. (2016). Mesoporous silica nanoparticles functionalized with hyaluronic acid and chitosan biopolymers. Effect of Functionalization on Cell Internalization. ACS Biomaterials Science & Engineering., 2, 741–751.
Sánchez Trujillo, I., García de Torres, A., Vereda Alonso, E. I., & Cano Pavón, J. M. (2013). Sequential determination of Pb, Cd and Hg by flow injection-chemical vapour generation-inductively coupled plasma mass spectrometry. Journal of Analytical Atomic Spectrometry, 28, 1772–1780.
Wang, S. (2009). Ordered mesoporous materials for drug delivery. Microporous and Mesoporous Materials, 117, 1–9.
Wuilloud, R. G., Acevedo, H. A., Vazquez, F. A., & Martinez, L. D. (2002). Determination of lead in drinking water by ICP-AES with ultrasonic nebulization and flow-injection on-line preconcentration using an amberlite XAD-16 resin. Analytical Letters, 35, 1649–1665.
Xiong, S., Wang, M., Cai, D., Li, Y., Gu, N., & Wu, Z. (2013). Electrochemical detection of Pb(II) by glassy carbon electrode modified with amine-functionalized magnetite nanoparticles. Analytical Letters, 46, 912–922.
Zhou, W., Li, C., Sun, C., & Yang, X. (2016). Simultaneously determination of trace Cd2+ and Pb2+ based on L-cysteine/graphene modified glassy carbon electrode. Food Chemistry, 192, 351–357.
Acknowledgments
AS acknowledges FIR 2018, RAS, and Fondazione di Sardegna (CUP F72F16003070002, 2017) and MIUR (FFABR 2017).
Funding
This work was supported by a grant of the Romanian Ministry of Research and Innovation, CCCDI-UEFISCDI, project number PN-III-P1-1.2-PCCDI-2017-0652/84PCCDI/2018, within PNCDI III.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Cotolan, N., Mureşan, L.M., Salis, A. et al. Electrochemical Detection of Lead Ions with Ordered Mesoporous Silica–Modified Glassy Carbon Electrodes. Water Air Soil Pollut 231, 217 (2020). https://doi.org/10.1007/s11270-020-04599-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s11270-020-04599-7