Abstract
Charged particle activation analysis (CPAA) is a rapid method with high accuracy which can analyze multi-elements simultaneously. Since multiple γ-ray detection method is expected to improve the detection efficiency and the signal-to-noise ratio, we study what design of the γ-ray detector array is the most suitable for CPAA. We take up four design candidates and investigated the responses by the radiation simulation code Geant 4. From the results, we have deduced the best design with 5 germanium detectors in close geometry. By inspecting the sensitivity in CPAA, the method is proved to be useful and applicable to 116 nuclides.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
In general, elemental quantification methods based on activation analysis have the characteristics of a rapid, non-destructive analysis with high accuracy which can handle multi-elements simultaneously. Charged particle activation analysis (CPAA) is a typical example of them [1,2,3,4,5,6,7,8,9,10,11,12] as well as neutron activation analysis (NAA) which is widely used. In the previous investigation [13], we have demonstrated that CPAA analysis is possible over the whole elements including the heavy nuclear region, while the determination sensitivity tends to decrease gradually as the target nucleus becomes heavy.
A typical beam needed for CPAA is an 8–15 MeV proton beam with an intensity of 0.1–1 μA. This kind of the beam can be provided by small accelerators which are commercially available for some medical applications such as positron emission tomography (PET) for cancer therapy. The beams provided by these accelerators are intense enough for CPAA. Nowadays, around 150 PET accelerators are running in Japan [14]. The introduction cost becomes reasonable so that a commercial CPAA facility is possible.
In CPAA and NAA we normally use a single germanium (Ge) detector. In the field of nuclear spectroscopy, an array of Ge detectors is often used to improve γ-ray detection efficiency and sensitivity [15,16,17]. Furthermore, in the previous investigations [18,19,20,21,22,23,24,25,26,27,28,29,30], we found that the γ–γ coincidence method or multiple γ-ray detection method utilizing the array of Ge detectors is effective in improving not only energy resolution in nuclide determination but also the detection limit in the γ-ray spectrum in NAA (for details see [29]). The method is called neutron activation analysis combined with multiple γ-ray detection (NAAMG) [29].
The multiple γ-ray detection method has also been applied to neutron prompt γ-ray analysis (PGA), which is called the multiple prompt γ-ray activation analysis (MPGA) [31,32,33,34,35,36]. The compound nucleus produced after the neutron capture reaction generally locates at high excitation energy (at several MeV). Prompt γ-rays emitted from such highly excited states generally have high energy and the number of the γ-rays is large reflecting a high level density in this region. Accordingly, the individual strength would be small. This situation sometimes makes the multiple γ-ray detection method less effective in PGA than in NAA. The merit of PGA is that it covers almost all the stable nuclides, while the applicability of NAA is restricted by the decay properties of produced nuclides, that are half life, γ-ray energy, γ-ray branching ratio and so on. Since CPAA deals with decay γ-rays similarly to those in NAA, we can expect a greater improvement of the detection limit by adopting multiple γ-ray detection method than the case of PGA. Here we study the applicability of the multiple γ-ray detection method to CPAA.
In this paper, we firstly study what design of the γ-ray detector array is the most suitable for CPAA. So far we have developed the GEMINI [37] and GEMINI-II [29] arrays for NAAMG and heavy ion induced in-beam γ-ray spectroscopy experiments, the STELLA array for MPGA and neutron induced in-beam γ-ray spectroscopy experiments in JRR-3 M facility, and the ANNRI array for MPGA and pulsed neutron induced in-beam γ-ray spectroscopy experiments in J-PARC facility. Their detector configurations are optimized for the different purposes and as a result, they are different from one another. Here we will investigate the optimum design for CPAA.
The detection limit is important as the performance of the multiple γ-ray detector array. The detection limit is derived from γ-ray detection efficiency and peak-to-background (signal-to-noise) ratio. We take up candidates of the detector configuration and investigate their performances by deriving the signal-to-noise ratio and detection efficiency, which are evaluated by Monte Carlo simulation code Geant 4.10.2 [38,39,40,41]. Based on the results, the optimum design of the multiple γ-ray detector array for CPAA is proposed.
Simulation
Details of CPAA
CPAA utilizing a 8–15 MeV proton beam will soon become possible by small accelerators such as the one for boron neutron capture therapy (BNCT) in the Ibaraki Neutron Medical Research Center (INMRC). In the previous investigation [13], we have shown that the possible reactions in CPAA are mostly (p, n) reactions but the other reactions of (p, α), (p, γ), (p, d), (p, 2n) and (p, t) are also available. The radionuclides generated by these reactions decay mostly by β−, β+ or electron capture process. The γ-rays, annihilation γ-rays and X-rays emitted after those decays could be utilized for CPAA. We can apply multiple γ-ray detection method to improve the energy resolution and the detection limit, since some of these radiations are emitted simultaneously in cascade.
Detector configurations
By taking into account the cost of the introduction and the maintenance suitable for a commercial device, we take up four possible configurations labeled A, B, C and D in Fig. 1 for the multiple γ-ray detector array. The design A is composed of six coaxial Ge detectors, each with a BGO anti-Compton shield. The BGO shield is used to decrease the background due to the Compton scattering in the Ge crystal. A lead collimator is placed before the front face of the BGO shield to prevent the γ-rays from directly entering it from a sample. The design B, C and D consist respectively of 6, 7 and 5 Ge detectors without BGO shields which are arranged so as to surround the sample. It is expected intuitively that the design A might have the highest signal-to-noise ratio and the design C and D might have higher detection efficiency than the others. We performed a realistic simulation to evaluate quantitatively the performance of each configuration and to know which configuration has the best detection limit.
Simulation for the spectrometer configurations
Simulations were performed using Geant 4.10.2 [38,39,40,41]. The Ge detector in the simulation were reproduced from the catalogue sheet for a commercially available Ge detector (AMETEK GMX40P4-70-A-S) with detection efficiency of 40% relative to a ϕ3″ × 3″ NaI scintillation detector. The BGO scintillation detector used in the simulation was manufactured by Saint-Gobain SA. The Ge detector and BGO shield for the simulation were reproduced from the drawing provided by the manufacture as detailed as possible as shown in Fig. 2. The dead layer of the Ge detector, however, had to be made considerably thicker than the drawing in order to improve the accuracy of the simulated detection efficiency. Materials outside of the detectors such as supporting frames and the sample itself were not taken into account in the simulation.
Simulation results and discussion
Comparison with experimental singles spectra
Before going to the detailed discussion of simulation results, we first compare the experimental γ-ray spectrum for the standard γ-ray source of 152Eu with the calculation in Fig. 3 both are taken at the source-to-detector distance of 25 cm. The differences of peak efficiencies between the experiment and calculation are shown in Table 1. The table shows that, while there is some deviation at low energy, the agreement is good taking account of the statistical error.
Total detection efficiency
The γ-ray detection efficiency at 1.33 MeV for a single detector at 5 cm from the source is calculated to be 0.56% from a γ-ray spectrum for 60Co. The calculated detection efficiencies for the proposed design A, B, C, and D are 1.66, 3.79, 4.89, and 5.06%, respectively. In spite of the smallest number of detectors (5), the design D has the largest detection efficiency reflecting the close geometry. The averaged detection efficiencies of single detector for each configuration are 0.29, 0.69, 0.81 and 1.17%, respectively.
These values are comparable with 1.5, 2.5, and 3.5% for GEMINI-II, STELLA (MPGA), and ANNRI, respectively in spite of the relatively small number of detectors included. The GEMINI-II array at the tandem accelerator facility in Tokai establishment in Japan atomic energy agency (JAEA) comprises sixteen BGO anti Compton spectrometers with 40–70% Ge detectors and three low energy photon spectrometers. The STELLA (MPGA) array in JRR-3 M guided neutron beam facility in JAEA is composed of eight BGO suppressed Clover detectors (120% relative efficiency) and four coaxial detectors (100% efficiency). Two BGO Compton suppressed EURISYS Cluster detectors and eight BGO suppressed coaxial detectors are used in the ANNRI detector array at the beam line #4 in J-PARC in JAEA.
Signal-to-noise ratio
One dimensional spectra and two dimensional γ–γ matrices are created to evaluate the signal-to-noise ratio and the determination sensitivity from the γ–γ coincidence events generated by the Monte Carlo simulation calculation code Geant 4.10.2. Figure 4 shows a typical example of two dimensional γ–γ matrix obtained for the design A by assuming a 152Eu standard source. The 152Eu standard γ-ray source is chosen for two reasons. One is that it is commercially available and can be used to obtain the experimental spectrum and matrix. The other is that it incorporates many γ-rays and coincident cascade γ-rays which are useful to evaluate the general features of signal-to-noise ratios. The decay scheme of 152Eu is well established by many investigations and summarized in [42]. The level structure is irregular enough at the high-energy region to assure that favorable feature as a γ-ray source. The γ-ray intensity is known down to 10−3 order relative to the strongest 122.2 keV transition.
In the evaluation of signal-to-noise ratio, we take into account all the γ-ray cascades tabulated in the β− decay data set of 152Eu in NUDAT application developed in Brookhaven National Laboratory; the 52 gates and the 475 cascades have been included [42].
The signal-to-noise ratio is evaluated as the ratio (A0–B0)/B0 for the singles spectrum for a single detector at 10 cm from the sample. Here a peak gross count A0 for a specified transition with the energy Eγ is obtained by summing counts between Eγ − 3 and Eγ + 3 keV. A background count B0 is summed between Eγ + 5 and Eγ + 11 keV. The signal-to-noise ratios are derived for all the 36 transitions tabulated in [42].
The signal-to-noise ratio is given as the ratio (A1–B1)/B1 for the singles spectrum for a detector array. Here a peak gross count A1 for a specified transition and a background count B1 are defined in the same manner as above.
The signal-to-noise ratio for the two-dimensional spectrum is evaluated as (A2–B2)/B2. Here a peak gross count A2 for a specified cascade γ1–γ2 is derived by summing counts in a rectangular region of Eγ1 − 3 to Eγ1 + 3 keV and Eγ2 − 3 to Eγ2 + 3 keV. A background count B2 is summed in a rectangular region of Eγ1 + 5 to Eγ1 + 11 keV and Eγ2 + 5 to Eγ2 + 11 keV.
The improvement factor IF(SN) of the signal-to-noise ratio for the two-dimensional spectrum relative to that of the singles spectrum is defined as
and is shown in Fig. 5 for the 36 transitions from 152Eu source tabulated in [42] as a function of γ-ray intensity. Data points scattering vertically originate from the IF(SN) values obtained for a single transition gated by the different transitions in the cascade.
One important common feature in Fig. 5 is that the improvement factor is much dependent on the counterpart of the coincidence in the cascade of which the branching ratio and the γ-ray energy differ. Another feature is that we cannot find much dependence of IF(SN) on the γ-ray intensities. The average values of the improvement factors are 177, 121, 112, and 155 for the design A, B, C, and D, respectively. Here the simulation has confirmed our earlier expectation that the design A may have the highest improvement for the signal-to-noise ratio.
Detection limit
When a nuclide with quantity, q, produces a peak in the singles spectrum of a single Ge detector (we may call it SS spectrum later), we can define the detection limit as
Here we take 3 times the standard deviation for the detection limit.
Also the detection limit deduced from the summed singles spectrum of the γ-ray detector array (we may call it SA spectrum later) is defined as
Similarly we can define the detection limit obtained from the two dimensional spectrum of the γ-ray detector array (we may call it MA spectrum later) as
Then the improvement factor of IF1(DL) and IF2(DL) for the SA and MA spectra relative to the SS are defined as follows, respectively.
The improvement factor IF1(DL) is shown in Fig. 6 for the 36 transitions from 152Eu tabulated in [42] as a function of γ-ray intensity. The averaged values are 4.58, 5.15, 5.82, and 6.40 for the design A, B, C, and D, respectively.
The improvement factor IF2 (DL) is shown in Fig. 7 for the same transitions as above. The averaged values are 1.31, 2.84. 3.69, and 3.93 for the design A, B, C, and D, respectively. Thus we conclude that the performance of the design D is the best on detection limit among them. Also we note the number (5) of Ge detectors of design D is the least of them that means the cost performance of the design D is the best as well.
Figure 8 show the typical γ-ray spectra; Blue line is the singles spectrum and red line is the projected spectrum gated by the 411 keV transition. The inset of the figure is the expanded portion of the spectra in the energy range between 600 and 1000 keV. The improvement of the signal-to-noise ratio and the detection limit is obvious in the figure. The peaks indicated by arrows in the inset are 678.6, 712.8, 794.8 and 937.1 keV transitions, showing the improvement factors of the signal-to-noise ratio between 132 and 379 in the design D.
Based on the calculated improvement factors of the signal-to-noise ratio and detection limit we deduce general features of the merits attained by using the γ-ray detector array of design D: they are (1) the signal-to-noise ratio would be improved by a factor between 10−1 and 104 (155 on the average), (2) the detection limit would be improved by a factor between 10−3 and 102 (3.9 on the average), and (3) the improvement factors of the signal-to-noise ratio and detection limit of a single transition depend much on the counterpart of the coincidence in the cascade: by properly selecting the gate condition we attain the improvement factors better than one in most of the cases.
The following is a comment for the case of improvement factors less than one. If both the singles and γ–γ coincidence measurements are available, we are able to choose the one with better signal-to-noise ratio and detection limit. In that case the signal-to-noise ratio would be improved by a factor between 1 and 104; the detection limit would be improved by a factor between 6.4 and 102.
Application to CPAA
As reviewed in [13], most elements (~ 65) can be analyzed among 85 stable elements including H-Bi, Th and U by CPAA. Since each element has plural stable nuclide[s], it amounts to 158 nuclides. However, the number of nuclides which emit cascade γ-rays is restricted to 116 nuclides.
As discussed in [13], most of the light elements with Z less than 20 are β+ emitters which emit no γ-rays but 511 keV annihilation γ-rays. To analyze those elements, only a singles γ-ray measurement or multiple γ-ray measurement is not sufficient and we require radiochemical procedure coupled with CPAA. Although CPAA generally has the characteristics of non-destructive analysis, it is difficult for those elements.
The sensitivity of a singles γ-ray measurement for almost all the stable nuclides in CPAA is already described in [13]. Here we deduce the sensitivity of a multiple γ-ray measurement for three nuclides, and discuss their accuracy and detection limit.
We take up three nuclides of 111Cd, 130Te and 100Ru, which transform to 111In, 130I and 100Rh via the (p, n) reaction. Following the procedures of [13], we calculate for each nuclide the radioactivity after irradiating a single-element sample of 1 μg with an 8 MeV and 1 μA proton beam; where the irradiation time is set to the half life of each nuclide but not exceeding 10 h. The number of decays is then calculated by assuming the same cooling and measuring time as in [13]. We made for each nuclide the Geant 4 calculation based on the γ-ray detector array of design D for the number of decays obtained above and derived a γ–γ matrix. From the γ–γ matrix we derive the peak and background counts for the most prominent peak of each nuclide. Table 2 is the summary of this analysis, showing the counts, accuracy and detection limit for the three nuclides.
The result shows that, in the present CPAA conditions, the peak counts are large enough for the element quantification. Due to the small background counts, the accuracy and detection limit are in the range of 1–3% and 0.03–0.11 ng, respectively. However we should note that in this calculation single-element samples of 1 μg were assumed and no matrix elements were included, which would cause background counts. Since element composition is much dependent on samples and accordingly background count is influenced by the composition, the accuracy and detection limit for actual samples need to be derived individually by taking into account the matrix elements. It will be made in forth coming papers.
Summary
For CPAA we take up four design candidates of a γ-ray detector array. By the radiation simulation code Geant 4.10.2, we investigated the performances of those detector candidates against the γ-rays emitted from 152Eu γ-ray source. We first studied the response of a single detector. By adjusting the thickness of the dead layer of the Ge detector, we have succeeded in reproducing the experimental γ-ray singles spectrum.
Next, we derived one-dimensional spectra and two-dimensional matrices for the four candidates of a γ-ray detector array. By inspecting the signal-to-noise ratios and detection limits for those candidates, we have deduced the best design of the γ-ray detector array for CPAA, which is the one utilizing five bare germanium detectors in close geometry. This design also gives the best cost performance.
We have calculated the improvement factors of the signal-to-noise ratio and detection limit for all the known 52 transitions and 475 cascades in β− decay of 152Eu, and deduced general features of the merits attained by using the γ-ray detector array of the best design presented above: they are (1) the signal-to-noise ratio would be improved by a factor of 155 on the average, (2) the detection limit would be improved by a factor of 3.9 on the average, and (3) the improvement factors of the signal-to-noise ratio and detection limit of a single transition depend much on the counterpart of the coincidence in the cascade: by properly selecting the gate condition we attain the improvement factors better than one in most of the cases.
Finally, in the application to CPAA analysis, we deduced the sensitivity of a multiple γ-ray measurement for three nuclides, their accuracy and detection limit. The result shows that the multiple γ-ray measurement is useful and applicable to 116 nuclides, which emit cascade γ-rays. The accuracy and detection limit, however, need to be studied individually for real samples, since background counts in the γ–γ matrix depend on the elemental composition.
References
Ricci E, Hahn RL (1965) Theory and experiment in rapid, sensitive 3He activation analysis. Anal Chem 37:742–748
Sanni AO, Roche NG, Dowell HJ, Schweikert EA, Ramsey TH (1984) On the determination of carbon and oxygen impurities in silicon by 3He activation analysis. J Radioanal Nucl Chem 81:125–129
Valladon M, Debrun JL (1977) Determination of oxygen in metals and semiconductors by means of the 16O(T, n) 18F reaction. J Radioanal Nucl Chem 39:385–395
Debefve P, Do HP, Friedli C, Lerch P (1981) Trace determination of oxygen in gold copper alloys and in high purity gold using 3He and 4He activation analysis. J Radioanal Nucl Chem 64:213–223
Bottger ML, Birnstein D, Helbig W, Niese S (1980) Removal of disturbances in carbon determination by activation analysis for lowering the detection limit. J Radioanal Nucl Chem 58:173–181
Yagi M, Masumoto K (1985) Simultaneous determination of Ti, Cr, Fe, Cu, Ga and Zr in aluminium alloys by charged-particle activation analysis using the internal standard method. J Radioanal Nucl Chem 91:379–387
Masumoto K, Yagi M (1985) Determination of strontium in biological materials by charged-particle activation analysis using the stable isotope dilution method. J Radioanal Nucl Chem 91:369–378
Yagi M, Masumoto K, Muto M (1986) An automatic gamma-ray spectrometer equipped with a micro-robot for sample changing. J Radioanal Nucl Chem 98:31–38
Yagi M, Masumoto K (1987) Instrumental charged-particle activation analysis of several selected elements in biological materials using the internal standard method. J Radioanal Nucl Chem 111:359–369
Shikano K, Yonezawa H, Shigematsu T (1993) Charged particle activation analysis of light elements at sub-ppb level. J Radioanal Nucl Chem 167:81–88
Chaturvedula CS, Banerjee A, Sauvage T, Courtois B, Duval F (2016) Application of 12 MeV proton activation to the analysis of archaeological specimens. J Radioanal Nucl Chem 308:241–249
Datta J, Dasgupta S, Guin R, Venkatesh M, Suvarna S, Chowdhury DP (2016) Determination of total arsenic and speciation of As(III) and As(V) in ground water by charged particle activation analysis. J Radioanal Nucl Chem 308:927–933
Oshima M, Yamaguchi Y, Muramatsu W, Amano H, Bi C, Seto H, Bamba S, Morimoto T (2016) Study of charged particle activation analysis (I): determination sensitivity for single element samples. J Radioanal Nucl Chem 308:711–719
PET http://www.jcpet.jp/1-3-4-1/. Accessed 19 Jun 2017
Lee IY (1990) The gammasphere. Nucl Phys A520:c641–c655
Wangen LE, Gladney ES, Starner JW, Hensley WK (1980) Determination of selenium in environmental standard reference materials by a gamma–gamma coincidence method using lithium-drifted germanium detectors. Anal Chem 52:765–767
Jakubek J, Nuiten P, Pluhar J, Pospisil S, Sinor M, Stekl I, Timoracky S, Vobecky M (1998) Coincidence gamma–gamma spectroscopy system for instrumental neutron activation analysis. Nucl Instr Method A414:261–264
Oshima M (2000) Non destructive trace element analysis. Look Japan 46:30–31
Hatsukawa Y, Oshima M, Hayakawa T, Toh Y, Shinohara N (2001) Application of multidimensional spectrum analysis for neutron activation analysis. J Radioanal Nucl Chem 248:121–124
Toh Y, Oshima M, Hatsukawa Y, Hayakawa T, Shinohara N (2001) Comparison method for neutron activation analysis with γ-γ matrix. J Radioanal Nucl Chem 250:373–376
Oshima M, Toh Y, Hatsukawa Y, Hayakawa T, Shinohara N (2002) A high-sensitivity and non-destructive trace element analysis based on multiple gamma-ray detection. J Nucl Sci Technol 39:292–294
Hatsukawa Y, Oshima M, Hayakawa T, Toh Y, Shinohara N (2002) Application of multiparameter coincidence spectrometry using a Ge detectors array to neutron activation analysis. Nucl Instrum Methods A 482:328–333
Oshima M, Toh Y, Hayakawa T, Hatsukawa Y, Shinohara N (2002) Development of a new method of neutron activation analysis with multiple gamma-ray detection—a high-sensitivity and non-destructive trace element analysis. J Nucl Sci Tech Suppl 2:1369–1371
Toh Y, Hatsukawa Y, Oshima M, Shinohara N, Hayakawa T, Kushita K, Ueno T (2002) Isotopic ratio of 129I/127I in seaweed measured by neutron activation analysis with γ–γ coincidence. Health Phys 83:110–113
Hatsukawa Y, Toh Y, Oshima M, Hayakawa T, Shinohara N, Kushita K, Ueno T, Toyota K (2003) New technique for the determination of trace elements using multiparameter coincidence spectrometry. J Radioanal Nucl Chem 255:111–113
Kimura A, Toh Y, Oshima M, Hatsukawa Y, Goto J (2007) Determination of As and Sb in iron and steel by neutron activation analysis with multiple gamma-ray detection. J Radioanal Nucl Chem 271:323–327
Hatsukawa Y, Miyamoto Y, Toh Y, Oshima M, Gharaie MHM (2007) Determination of trace elements using multi-parameter coincidence spectrometry. J Radioanal Nucl Chem 271:43–45
Kimura A, Toh Y, Oshima M, Hatsukawa Y (2008) Lower limit of determination values for trace elements in iron certified reference materials by neutron activation analysis with multiple gamma-ray detection. J Radioanal Nucl Chem 278:521–525
Oshima M, Toh Y, Hatsukawa Y, Koizumi M, Kimura A, Haraga A, Ebihara M, Sushida K (2008) Multiple gamma-ray detection method and its application to nuclear chemistry. J Radioanal Nucl Chem 278:257–262
Jorgensen UG, Appel PWU, Hatsukawa Y, Frei R, Oshima M, Toh Y, Kimura A (2009) The earth–moon system during the late heavy bombardment period—geochemical support for impacts dominated by comets. Icarus 204:368–380
Oshima M, Toh Y, Kimura A, Ebihara M, Oura Y, Itoh Y, Sawahata H, Matsuo M (2007) Multiple prompt gamma-ray analysis and construction of its beam line. J Radioanal Nucl Chem 271:317–321
Toh Y, Koizumi M, Oshima M, Kimura A, Hatsukawa Y, Osa A, Goto J (2007) Analysis of toxic elements by MPGA. J Radioanal and Nucl Chem 272:303–305
Toh Y, Oshima M, Koizumi M, Kimura A, Hatsukawa Y (2008) Development of multiple prompt gamma-ray analysis. J Radioanal Nucl Chem 276:217–220
Toh Y, Oshima M, Koizumi M, Osa A, Kimura A, Goto J, Hatsukawa Y (2006) Analysis of cadmium in food by multiple prompt γ-ray spectroscopy. Appl Radiat Isot 64:751–754
Oura Y, Watanabe R, Ebihara M, Murakami Y, Toh Y, Kimura A, Koizumi M, Furutaka K, Oshima M, Hara K, Kin T, Nakamura S, Harada H (2012) Application of multiple prompt gamma-ray analysis (MPGA) to geochemical and cosmochemical samples. J Radioanal Nucl Chem 291:335–339
Shozugawa K, Matsuo M, Sano Y, Toh Y, Murakami Y, Furutaka K, Koizumi M, Kimura A, Hara K, Kin T, Oshima M, Nakamura S, Harada H (2012) Chemical composition of sediments from marine shallow-water hydrothermal mounds in Wakamiko submarine crater revealed by multiple prompt gamma-ray analysis. J Radioanal Nucl Chem 291:341–346
Furuno K, Oshima M, Komatsubara T, Furutaka K, Hayakawa T, Kidera M, Hatsukawa Y, Matsuda M, Mitarai S, Shizuma T, Saitoh T, Hashimoto N, Kusakari H, Sugawara M, Morikawa T (1999) A γ-ray detector array for joint spectroscopy experiments at JAERI tandem booster. Nucl Instr Method A421:211–226
Geant 4. http://geant4.cern.ch/. Accessed 19 June 2017
Agostinelli S et al (2003) Geant 4—a simulation toolkit. Nucl Instr Method A506:250–303
Allison J et al (2006) Geant 4 developments and applications. IEEE Trans Nucl Sci 53:270–278
Allison J et al (2016) Recent developments in Geant 4. Nucl Instr Method A835:186–225
NuDat. http://www.nndc.bnl.gov/nudat2/. Accessed 19 Jun 2017
Acknowledgements
The authors appreciate the discussions by Drs. T. Hayakawa and Y. Hatsukawa of National Institutes for Quantum and Radiological Science and Technology. This work was supported in part by JSPS KAKENHI Grant Number 15K01357.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Goto, J., Oshima, M., Sugawara, M. et al. Introduction of multiple γ-ray detection to charged particle activation analysis. J Radioanal Nucl Chem 314, 1707–1714 (2017). https://doi.org/10.1007/s10967-017-5558-6
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10967-017-5558-6