Introduction

Ascorbic acid (AA), or vitamin C (VC), is a common water-soluble vitamin with good antioxidant properties. It plays a key role in human metabolism and growth [1]. However, the AA can’t be synthesized or converted by the body itself [2], and its lack can lead to scurvy, colds, mental disease and infertility [3,4,5]. Meanwhile, AA can promote the synthesis of collagen, enhancing the body resistance [6]. The daily needs of the human body for VC are mainly obtained by ingesting fruit. The change of the VC content is one of the important indicators to judge the freshness and storage of fruits. In this regard, it is of great significance to establish a rapid and effective method for detecting the VC in fruits. Many methods for AA detection, including electrochemistry [7, 8], high performance liquid chromatography (HPLC) [9, 10], colorimetric [11] and etc. Although these methods can meet the requirement of sensitivity, they are usually time-consuming, cumbersome, expensive or the need of complex synthesis or complicated extraction process. The fluorescent assay technique received extensive attention because of the advantages of high sensitivity, good reproducibility, easy to realize real-time, and in situ monitoring [12,13,14].

Hydrogen peroxide (H2O2) is a relatively common peroxide, which is often used as an oxidant, bleach agent and disinfectant in real life. H2O2 plays an important role in biological metabolism and environmental engineering. However, under normal circumstances, H2O2 is easily decomposed into water and oxygen, not easy to exist for a long time. On October 27, 2017, the World Health Organization’s International Agency for Research on Cancer published a preliminary list of carcinogens, H2O2 is in the list of three types of carcinogens. Therefore, it is of great significance to develop a rapid and accurate detection method for H2O2.

Over the last decade, carbon quantum dots (CQDs) have get extensive attention because of its unique properties, including tunable photoluminescence, molecular size, excellent photostability, low toxicity, chemical inertness, good solubility, biocompatibility, and ease of functionalization [15,16,17]. Lately, a large mass of fluorescent probes have been developed to the monitoring of metal ions [18,19,20]. For example, green fluorescent nitrogen-rich quantum dots (N-dots) served as a turn-off chemosensor for rapid and selective detection of Hg2+ and Ag+ in aqueous solutions [21]. A reusable P, N-doped carbon quantum dot was utilized as an efficient probe for detecting cobalt ion [22].

In this paper, an inexpensive way to synthesize multifunctional S,N-CQDs by utilizing citric acid (CA) and methionine (Met) was developed. Interestingly, the luminescence intensity of S,N-CQDs was effectively quenched by Fe3+. Meanwhile, as we all know, the Fe3+ could be converted into Fe2+ under the presence of ascorbic acid or Fe2+ could be converted to Fe3+ under H2O2. Accordingly, on the basis of the fluorescence quenching mechanism and the principle of chemical reaction, we proposed an experimental strategy for rapid monitoring of AA and H2O2. The proposed method is depicted in Scheme 1. Initially, the luminescence of S,N-CQDs could be quenched by the iron(III). However, when AA is added to the system, iron(III) ions are reduced to iron(II) ions, the recovery efficiency of luminescence intensity displayed a linear fluorescent response to the concentration of AA. Finally, the iron(II) ions could be oxidized to iron(III) ions under the presence of H2O2. The fluorescence intensity will be annihilated again due to the iron(III) ions.

Scheme 1
scheme 1

Design and principle for AA and H2O2 detection use S,N-CQDs/Fe3+ or S,N-CQDs/Fe2+ system.

Experimental Section

Materials and Reagents

Citric acid, FeCl3·6H2O, FeCl2·4H2O, trimethylaminomethane, NaOH, HCl, KCl, NaCl, NH4Cl, Na2SO4, Al(NO3)3, NaH2PO4, Na2HPO4, Zn(NO3)2, CaCl2, MgSO4, MnCl2, H2O2, Ni(NO3)2, CuSO4, Cd(NO3)2, Pb(NO3)2, glucose, were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Quinine sulfate, ascorbic acid, N-2-Hydroxyethylpiperazine-N′-2-ethylsulfonyl (HEPES), Amino acids (Cys, Try, His, Tyr, Trp, Phe, Met) were purchased from Aladdin (Shanghai, China). All reagents were analytical reagent grade. Water used in the experiment (18.2 MΩ cm) was purified by a Millipore-Q system.

Apparatus

The size and morphology of S,N-CQDs was characterized by performing on an electronic microscope (TEM, Hitachi). Fourier transform infrared spectroscopy (FT-IR) was recorded by a Bruker IFS 66v/S infrared spectrophotometer (Bruker Optics Inc., Billerica, MA, USA). The crystalline phases of S,N-CQDs were characterized using a Rigaku D/max 2550 Xray diffractometer (XRD). All absorption spectra were measured on a UV-2600 UV-Vis spectrophotometer (Shimadzu, Japan). The chemical composition and state of S,N-CQDs were investigated by PHI Quantera II X-ray photoelectron spectroscopy (XPS, Thermo Fisher Scientific 250Xi). Fluorescence spectra were measured on a LS-55 spectrofluorometer with excitation silt width of 10 nm and emission silt width of 15 nm (PerkinElmer, USA). The fluorescence lifetime was measured with Fluo Time 100 (PicoQuant, Germany). All pH measurements were made with a PHS-3E pH meter (Inesa Instrument, China).

Preparation of S,N-CQDs

S,N-CQDs were synthesized via a one-step hydrothermal method. The detailed procedures are as follows: citric acid (4.5 g) and methionine (2 g) were mixed with ultrapure water (10.0 mL). And the mixture was then sonicated for 3 min to give a transparent solution. The solution was then transferred to a poly(tetrafluoroethylene) (Teflon)-lined autoclave (25 mL), heated at 180 °C for 10 h and then cooled down to room temperature. The brown-yellow product was further purified by filtration (0.22 μm nitrocellulose filters). After evaporating the solvent and further drying under vacuum, the S,N-CQDs were dispersed in the aqueous solution as stock solution for later characterization and use.

Detection of Fe3+ Based on S,N-CQDs

In a typical assay of Fe3+, 20 μL (50 μg/mL) of S,N-CQDs was added to 280 μL 50 mM tris buffer solution which contained various of chemical species (Fe3+, Cu2+, Pb2+, Fe2+, K+, Zn2+, Cd2+, Mg2+, Al3+, Na+, Mn2+, Ni2+, NH4+, Ca2+, Cys, Try, Phe, His, Tyr, Trp, glucose, AA, H2O2). Then, the fluorescence spectra were recorded after 1 min. In order to investigate the relationship between the different Fe3+ concentrations and the fluorescence data of S,N-CQDs, different concentrations of a Fe3+ solution were added to the system. The fluorescence spectra were measured with excitation at 330 nm (excitation bandwidth 10 nm).

AA Sensing Based on S,N-CQDs/Fe3+

AA detection was realized as follows: different concentrations of AA were added to 300 μL S,N-CQDs/Fe3+ system (50 μg/mL in 50 mM Tris-HCl, pH 6.0). Following that, the mixtures were transferred into a 400 μL quartz cuvette. The fluorescence spectra of the final mixture solution were measured. (excited at 330 nm).

Monitoring of H2O2 Based on S,N-CQDs/Fe2+

For the H2O2 detection, the H2O2 solutions with varied concentrations were added to 300 μL S,N-CQDs/Fe2+ system (50 μg/mL in 50 mM Tris-HCl, pH 6.0). Afterward, the mixtures were transferred into a 400 μL quartz cuvette. The luminescence emission signals were measured with excitation at 330 nm.

Real Sample Assay

A variety of fruits were purchased from the fruit shop (The orange, grapefruit and lemon are all fresh, Bubugao supermarket, Changsha, Hunan) and then fruit juices were squeezed out. Furthermore, to remove the matrix effect, real fruit juices filtered with a 0.45 μM filter membrane was obtained and then diluted 10 times with ultrapure water. Vitamin C lozenge (The mass of the whole chewable tablet is 1 g and each tablet contains 0.1 g of vitamin C, Jiangxi Xinyijiang Pharmaceutical Co., Ltd.) was ground into powder with a mortar. After being diluted into an appropriate concentration with ultrapure water, AA with different concentrations was spiked into the real samples, which was detected following the as-provided strategy.

Medical hydrogen peroxide disinfectant (hydrogen peroxide 3%~3.5%, Yiyang Medical Research Institute, Hunan Province) was purchased from a local clinic. The sample was diluted into an appropriate concentration with ultrapure water. Standard H2O2 solution with different concentrations was spiked into the real samples, the fluorescence spectra were recorded at 395 nm (excited at 330 nm).

Results and Discussion

Characterization of S,N-CQDs

In order to study the structure and morphology of the prepared S,N-CQDs, a series of characterizations including TEM, FT-IR, XRD, UV–vis and XPS were conducted. As shown in Fig. 1a, uniform particle size distribution for S,N-CQDs can be observed and the S,N-CQDs are spherical and well-dispersed. As shown in Fig. 1b, FT-IR spectrum of S,N-CQDs reveals a band around 3404 cm−1 correlated with OH stretching vibrations. Meanwhile, the peak at 2924 cm−1 corresponds to the stretching of C-H. The peak at 1713 cm−1 is attributed to C=O stretching vibration. The peak at 1654 cm−1 might be attributed to C=C, C=O and C=N stretching in the conjugated structure [23]. The characteristic absorption bands of C–S–C stretching vibration at 1202 cm−1 demonstrated the presence of S elements on the surface of S,N-CQDs. XRD results (Fig. 1c) showed that a broader peak around 23.5°, which indicated that the N,S-CQDs appeared to be amorphous carbon particles in nature [24, 25]. In UV–vis spectrum (Fig. 1d), there are two distinct absorption peaks. One can be assigned to n-σ* transition at 213 nm, which indicates the presence of -NH2. The other one might attribute to n-π* transition of C=O bond at 313 nm [26, 27].

Fig. 1
figure 1

a TEM images of S, N-CQDs. (b) FT-IR spectra of S,N-CQDs. (c) XRD pattern of the S,N-CQDs. (d) UV–vis absorption spectrum of S,N-CQDs

The results of XPS analysis are shown in Fig. 2. Four distinct peaks around 164.0 eV, 286.0 eV, 399.0 eV, and 532.0 eV in Fig. 2a could be ascribed to sulfur, carbon, nitrogen and oxygen, respectively [28]. As shown in Fig. 2b, C1s spectrum could be divided into five main peaks corresponding to C=C, C − C (284.6 eV), C − S (285.2 eV), C − N (286.1 eV), C − O (286.8 eV), and C=N, C=O (288.4 eV) functional groups [29, 30] respectively. Deconvolution of N1 s spectra in Fig. 2c reveals two nitrogen species of −NH (399.6 eV) and C − N − C (400.0 eV) [31, 32]. The detailed information of sulfur could be characterized by the deconvoluted high resolution S2p spectrum in Fig. 2d. The peak at lower binding energy consisted of two peaks, in which peak at 163.3 eV and 164.6 eV was assigned to S2p3/2 and S2p1/2, respectively [33].

Fig. 2
figure 2

a XPS spectrum of S,N-CQDs. b High-resolution XPS spectra of C1s, c N1 s and (d) S2p

Fe3+ Detection Performance

To test the specificity of this fluorescence probe, the fluorescence responses of S,N-CQDs upon addition of the potential interferring species were examined. Figure 3a displays the selectivity results of the method toward Fe3+ in the presence of other interfering species. A dramatic fluorescence quenching was observed when Fe3+ was added to the solution of S,N-CQDs, while no significant fluorescence decrease happened at the introduction of any other species, suggesting that this fluorescence system cannot be interfered by other species. The possible mechanism is that the introduced sulfur atoms seem to be able to eliminate the O-states and enhance the N-states, leading to that the original surface states nearly neglected in the N,S-CQDs.

Fig. 3
figure 3

a Selectivity of 50 μg/mL N, S-CQDs after adding different metal ions and other interferents with the same concentration of 1 mM. b The relationships between (F0 -F)/F0 and Fe3+ ions (50–1000 μM). c The relationship between (F0 -F)/F0 and Fe3+ from 50 to 300 μM. (d) The relationship between (F0 -F)/F0 and Fe3+ from 300 to 800 μM. F and F0 are the FL intensities of S,N-CQDs in the presence and absence of Fe3+, respectively. All data represent the fluorescence intensity at 395 nm in the 50 mM Tris-HCl buffer at pH 6.0, λex = 330 nm

Then the response of the S,N-CQDs at different Fe3+ concentrations was evaluated. The fluorescence was gradually quenched with increasing concentration of Fe3+ from 50 μM to 1000 μM (Fig. 3b). Additionally, Fig. 3c and Fig. 3d displays the fluorescence data versus the different Fe3+ concentrations. The fluorescence intensity at 395 nm was linearly correlated with the Fe3+ concentration in the range of 50–300 μM (R2 = 0.995) and 300–800 μM (R2 = 0.981), respectively. The detection limit (in terms of the 3σ rule) was calculated to be 5.0 μM.

AA Sensing Performance

To further explore the selectivity of this nanosystem for AA, other potential interferents including a variety of metal ions, amino acids, and organics (AA, Fe2+, K+, Mg2+, Na+, Ca2+, Cys, Try, Phe, His, glucose) were incubated with a mixed solution of S,N-CQDs/Fe3+. Figure 4a vividly shows the fluorescence recovery degree under different species. Obviously, the mixture solution of AA and S,N-CQDs/Fe3+ exhibited the highest fluorescence recovery relative to other interferents, revealing that the N,S-CQDs/Fe3+ composite possessed high specificity toward AA under the presence of other interfering species. In addition, the fluorescence intensity of S,N-CQDs/Fe3+ at around 395 nm increased gradually with increasing AA concentrations (Fig. 4b). Figure 4c depicts the feasibility that S,N-CQDs/Fe3+ as excellent probe in the detection of AA. As indicated in Fig. 4d, the enhancement of FL had a good linearity to the AA concentration in the range from 50 to 500 μM and the limit of detection (LOD) was 4.2 μM. As shown in Fig. S1, AA performed different fluorescence recovery effect in different buffer solutions. But only in Tris-HCl buffer, AA had the best fluorescence recovery effect. The pH stability of S,N-CQDs/Fe3+ system is displayed in Fig. S 2a, in which fluorescence intensity changed little in the pH range from 3 to 12.

Fig. 4
figure 4

a FL responses of the S, N-CQDs/Fe3+ system towards different chemicals at the concentration of 1 mM (the concentration of AA is 600 μM). b FL responses of the S, N-CQDs/Fe3+ system towards different concentrations of AA (25, 50, 100, 150, 200, 250, 300, 350, 400, 500, 600 μM). c Representative fluorescence emission spectra of S, N-CQDs/Fe3+ in the presence of increasing AA concentrations (50–500 μM) in 50 mM Tris-HCl buffer at pH 6.0. d Plot of FL responses of S, N-CQDs/Fe3+ vs concentration of AA from 50 to 500 μΜ

H2O2 Monitoring Performance

The selectivity of S,N-CQDs/Fe2+ toward H2O2 was evaluated by screening its response to metal ions, amino acids and organics (H2O2, AA, K+, Mg2+, Na+, Ca2+, Cys, Try, Phe, His, glucose, Tyr). As indicated in Fig. 5a, the fluorescence intensity was the feeblest when H2O2 was added to the S,N-CQDs/Fe2+ system, suggesting that S,N-CQDs/Fe2+ could be applied to selectively monitor H2O2 in aqueous solution. In contrast, no obvious decrease in fluorescent intensity could be observed by adding other interfering species. For the sake of achieving good quenching effect, the appropriate Fe2+ concentration was also optimized. As shown in Fig. 5b, when the Fe2+ concentration reached 1 mM, the fluorescence intensity of S,N-CQDs could be well quenched. Under optimized condition, we explored the application of S,N-CQDs/Fe2+ as a fluorescence sensing for the measurement of H2O2. Figure 5c depicts the fluorescence spectroscopy recovery of S,N-CQDs/Fe2+ composite system after adding different concentrations of H2O2, implying the feasibility that S,N-CQDs/Fe2+ as excellent probe in the detection of H2O2. Figure 5d illustrates the relationship between the fluorescence intensity at 395 nm with various concentrations of H2O2. A linear calibration in the scope of 10 to 140 μM (R2 = 0.996) was constructed. The detection limit of H2O2 was calculated to be 1.9 μM according to the equation 3σ/S. Moreover, as shown in Fig. S 2b, the effect of pH was also investigated, the result shows fluorescence intensity of S,N-CQDs/Fe2+ droped sharply in the case of alkaline condition.

Fig. 5
figure 5

a FL responses of the S, N-CQDs/Fe2+ system towards different chemicals at the concentration of 1 mM (the concentration of H2O2 is 300 μM). b The relationships between (F0 -F)/F0 and Fe2+ (0.3–2.7 μM) in the presence of 500 μM H2O2. c Representative fluorescence emission spectra of S, N-CQDs/Fe2+ in the presence of increasing H2O2 concentrations in 50 mM Tris-HCl buffer at pH 6.0. (d) The relationships between (F0 -F)/F0 and H2O2 (2.5–300 μM)

Application in Real Samples

Practical application for the development of S,N-CQDs/Fe3+ and S,N-CQDs/Fe2+ as fluorescent probes was exploited. For the purpose of verifying the method, standard addition experiments were carried out with fruit juices and hydrogen peroxide disinfectant. Table 1 shows the AA test results, the relative standard deviation (RSD) was lower than 5.1 and the recoveries were found to be varied between 87.8% and 117.5% for the samples of various fruit juices. Table 2 shows the H2O2 test results, RSD was found to be lower than 3.1 with the recoveries between 99.2% and 106.4% for the detection of hydrogen peroxide disinfectant.

Table 1 AA detection in diverse real samples
Table 2 H2O2 detection in real sample

Conclusions

In conclusion, the synthetic S,N-CQDs were thoroughly characterized by chemical morphology and structural analysis, affirming the presence of various functional groups associated with sulfur and nitrogen. Moreover, the fluorescence intensity of S,N-CQDs was effectively quenched by Fe3+ and then facilely recovered with the addition of AA. On the basis of the fluorescence quenching-recovery principle, we proposed an experimental strategy for the determination of strongly reducing and oxidizing substances based on a simple redox principle and the proposed method has been successfully applied to selective monitoring of AA and H2O2 in an enzyme-free and label-free way. The as prepared S,N-CQDs/Fe3+ and S,N-CQDs/Fe2+ might provide an effective way for the measuring of various redox reaction–involved system, and might have great potential for food industry monitoring and commercial testing.