Introduction

Exposure of human beings to the ionizing radiations present in the natural environment has associated health risk concerns. Radon (222Rn) and thoron (220Rn) are radioactive gaseous elements produced as immediate decay products of 226Ra and 224Ra respectively, found in decay chains of 238U and 232Th present in earth’s crust. Radon having half-life (t1/2) of 3.8235 days decays by alpha radiation of energy 5.48 MeV where as thoron having half-life (t1/2) of 55.6 sec emits alpha radiation of energy 6.28 MeV. Radon has been long known as lung cancer causing agent (Darby et al., 2005; Stojanovska et al., 2011). Radon and thoron gases enter into the indoor air through the process of exhalation from soil and building materials (Nazaroff and Nero, 1988).These gases and their decay products present in air enter the human body mainly through inhalation. Recent studies have established that thoron and its decay products also have significant contribution to inhalation dose along with radon and associated decay products (Smetsers & Thomas, 2019). Interaction of alpha particles, emitted by the short lived decay products of radon and thoron with biological tissues in the lungs may lead to DNA damage resulting in development of lung cancer (Edling et al., 1986; Sevc et al., 1976).The worldwide annual effective dose received by the population from all natural and artificial sources is 2.8 mSv, out of which nearly 85 % of the dose (2.4 mSv) comes from only natural background radiations (UNSEAR, 2000b). Also it is well documented that radon and thoron along with their decay products account for more than 50% of the natural background radiation dose received by the humans (UNSCEAR, 2008). The indoor concentration of radon, thoron and decay products depends on environmental (such as seasons) as well as anthropogenic factors (such as dwellings). Several studies have highlighted the role of such factors towards the variations of the indoor concentration data in the past. Stojanovska et al. (2011) in their study performed in dwellings of Macedonia found that the average radon concentration was highest (115 Bq/m3) in the winter season among winter, spring, summer and autumn seasons. They also studied the influence of building characteristics such as floor type, house age, building material, basement and type of windows on radon concentration. In a follow-up work in the same region, Stojanovska et al. (2013) obtained seasonal and regional variability for the measured data of indoor thoron concentration. A study performed in the region of Garhwal Himalayas (Ramola et al., 2016) revealed that ventilation conditions do not affect the thoron concentration but affect the radon concentration due to the shorter half-life of the former. The study also showed the dependency of radon/thoron, their decay products and equilibrium factors on seasons. The geometric mean annual effective dose due to radon and its decay products and thoron and its decay products was found to be 1.1 mSv and 0.5 mSv, respectively. Researchers have taken keen interest in the Punjab region in recent past aiming to measure and interpret indoor radon/thoron and the decay product’s concentration levels. Mehra et al. (2006) reported an average indoor concentration value of 90.60 Bq/m3 in their measurement campaign performed using the bare mode technique in the Malwa region of Punjab. Virk and Sharma (2000) reported variation of the annual effective dose from 0.61 to 1.11 mSv with an average value of 0.92 mSv using a twin-chamber Rn-Tn dosimeter cup for Punjab. The annual effective dose has also been reported varying between 3 and 10 mSv for Hamirpur district, Himachal Pradesh (Singh et al., 2016). Widely varying geological influences, climatic patterns, source term etc. necessitate study of measurements of radon and thoron gases and decay products for different regions covering different contexts.

The present study measures the indoor concentration of radon/thoron and their decay products in Ludhiana district of Punjab, India. Pinhole dosimeters for gaseous measurements and deposition-based progeny sensors for decay product measurements have been used in this work. The measured values have been employed to estimate the equilibrium factors, inhalation doses and annual effective doses for this region. The work discusses interpretations of the observed data in terms of the effect of variations in seasons, building materials, ventilation condition, altitude etc. as well.

Study area

Geology

Ludhiana district is centrally located in the Malwa region (plain) of Punjab, India, as shown in Fig. 1. The total geographical area occupied by the district is about 3767 km2. In 2011, the total population was 3,498,739 in the district (District survey report). The district is situated between north latitudes 30° 33′ and 31° 01′ and east longitudes 75° 25′ and 76° 27′. The area is covered by Indo-Gangetic alluvium. The variation in soil profile is sandy loam to clayey with normal reaction (pH 7.8 to 8.5) (Ludhiana district Punjab, 2013). Figure 1 is showing different types of soil in Punjab state of India (Punjab Remote Sensing Centre, Ludhiana) as well. The major hydrographic features of the district are Satluj river and its minor tributary, Budhanala.

Fig. 1
figure 1

Map showing different soil types in Punjab state of India (Punjab Remote Sensing Centre, Ludhiana)

Climate

The climatic periods of district in a year are described as tropical steppe, hot and semi-arid. These are generally dry with hot summer and very cold in winter except the monsoon season. According to the District survey report, there are four seasons viz. winter (mid-November to early March), summer (March to end of June), monsoon (July, August and first half of September) and post-monsoon (mid-September to mid-November). June is known to be the hottest month due to the mean daily temperature of 40.6 °C, which reaches as high as 45 °C on single days. January is the coldest month with a mean minimum temperature of 6.4 °C. In August, the precipitation reaches the peak with average rainfall of 202 mm (District survey report).

Materials and methods

Design of the investigation

The main objective of the present study was to collect the representative results of levels of indoor radon/thoron and their decay products in the Ludhiana district. A preliminary study was conducted in 217 villages of the district to measure the outdoor gamma dose rate levels. These measurements were carried out in air at a height of 1 m above the ground using an AT2140 portable dosimeter (ATOMTEX). These villages were then classified into three categories on the basis of gamma dose rate levels. The criterion for classification was the villages with gamma dose rate < 0.1 µSv/h, dose rate in range 0.1–0.2 µSv/h and villages with outdoor gamma dose rate level > 0.2 µSv/h. In our measurements, no villages with dose rate levels > 0.2 µSv/h were found. For these categories, dwellings were further divided on the basis of floor material like mud, fired bricks, mosaic floor tiles, cement and marble. Floor was chosen because soil beneath a dwelling is considered the most prominent source of indoor radon.

Table 1 shows the statistics of the dwellings chosen for the preliminary and the main part of the present study. Out of 217 samples, 106 dwellings from 42 villages were selected for the main part. Figure 2 depicts the location of 42 villages selected for conducting the measurements in study area. The targeted dwellings were also divided on the basis of ventilation criterion (good, average, poor) and type of room (bedroom, hall and kitchen).

Table 1 Summary of dwelling characteristics
Fig. 2
figure 2

Map showing the location of 42 villages selected for measurements in Ludhiana district

Measurements were conducted in three cycles of 4 months to include the effect of seasonal variation. These three cycles of months are chosen on the basis of temperature, humidity and precipitation/rainfall level as shown in Table 2 (District survey report). The three cycles of measurements were from November to February (winter season), March to June (summer season) and July to October (rainy season). Pre- and post-monsoon months were combined into rainy season as the mean daily maximum temperature for these months was close. High humidity in the months of July to October is due to higher precipitation in these months compared to months of other seasons.

Table 2 Mean daily maximum and minimum temperatures, humidity and precipitation/rainfall in Ludhiana district of Punjab

Estimation of indoor radon and thoron gas concentrations

For the estimation of indoor radon and thoron gas concentrations, a single-entry (facing down) pinhole dosimeter (Fig. 3) comprising of SSNTD (solid-state nuclear track detector) LR-115 film was used. It gives time-integrated concentration levels of radon and thoron and is based on the radon-thoron discrimination technique. The minimum detection limit for radon and thoron concentration in the pinhole dosimeter is 2 Bq/m3 and 6 Bq/m3, respectively (for details see, Sahoo et. al., 2013).

Fig. 3
figure 3

Schematic diagram of single-entry pinhole dosimeter

The dosimeters were suspended from the ceiling, at least 10–20 cm away from nearest wall and at a height of at least 1.5 m from the ground for an exposure period of 4 months. The retrieved films were chemically etched in the laboratory with 2.5 N NaOH at 60 °C for 90 min and counted using a spark counter to get the values of the density of tracks registered on the LR-115 films.

Radon and thoron gas concentrations were calculated from the track densities using the formulae given in Eqs. (1) and (2) (Sahoo et. al., 2013):

$${C}_{R}=\frac{{T}_{1}-B}{t\times {K}_{R}}$$
(1)
$${C}_{T}=\frac{{T}_{2}-{T}_{1}}{t\times {K}_{T}}$$
(2)

where CR is the radon gas concentration (Bq/m3); T1 and T2 are the track densities (tracks/cm2) measured for both the radon and radon + thoron chambers, respectively; B is the background counts observed; KR (0.017 ± 0.003 tracks/cm2/day/Bq/m3) and KT (0.010 ± 0.005 tracks/cm2/day/Bq/m3) are the calibration factors for radon in the radon chamber and for thoron in the radon + thoron chamber, respectively; and t is the exposure period (number of days).

Estimation of equilibrium equivalent radon/thoron concentrations (EERC/EETC)

Measurements of equilibrium equivalent radon/thoron concentrations (EERC/EETC) were performed with direct radon/thoron progeny sensors (DRPS/DTPS), depicted in Fig. 4.

Fig. 4
figure 4

Schematic diagram of direct deposition–based radon/thoron progeny sensors (DTPS/DRPS). (a) is for DTPS and (b) for DRPS

In the DRPS, an absorber of thickness 37 µm is in combination with the LR-115 detector, to detect α-particles emitted from 214Po having energy of 7.69 MeV, formed from the decay of 218Po, 214Pb and 214Bi atoms deposited on the sensor (Mishra et. al., 2009). To measure EETC, the LR-115 detector is mounted with an aluminised Mylar absorber of 50-µm thickness to record the tracks formed by α-particles emitted from 212Po having energy of 8.78 MeV, which are formed from the decay of 212Pb and 212Bi atoms deposited on the Mylar surface. Due to difference in thickness (50 µm and 37 µm) of the absorber in the DTPS and DRPS, there is no mutual interference of deposited progenies. In the DRPS and DTPS, the minimum detection limit for radon progeny and thoron decay products is 1 Bq/m3 and 0.1 Bq/m3, respectively (Bangotra et. al., 2019). The DRPS and DTPS were exposed along with the pinhole dosimeters in the dwellings for the same exposure period. The exposed LR-115 films were chemically etched and counted as explained earlier.

The equilibrium equivalent thoron/radon concentrations (EETC/EERC) were calculated using the formulae given by Eqs. (3) and (4) (Mishra and Mayya, 2008):

$$EETC= \frac{{T}_{T}-B}{t\times {S}_{TT}}$$
(3)
$$EERC=\frac{\left({T}_{R}-B\right)-EETC\times {S}_{RT}\times t}{t\times {S}_{RR}}$$
(4)

where STT, SRT and SRR are sensitivity factors for DTPS and DRPS, respectively, estimated by Mishra et al. (2010). The value of the sensitivity factor STT is 0.94 ± 0.027 tracks/cm2/day/EETC (Bq/m3), and sensitivity factors SRR and SRT are 0.09 ± 0.0036 tracks/cm2/day/EERC (Bq/m3). B is the background track density; TT and TR are the measured track densities in DTPS and DRPS, respectively; and t is exposure period (number of days).

Estimation of equilibrium factors

Significant dependence of equilibrium factors on the regions, climate, ventilation and other factors has been reported in different studies (Ramola et. al., 2016, Porstendorfer, 1984). Hence, the equilibrium factors were computed using the gas concentrations and the progeny concentrations for individual dwellings. For calculating equilibrium factors, i.e. FR for radon and FT for thoron, the following Eqs. (5) and (6) were used:

$${F}_{R}=\frac{EERC}{{C}_{R}}$$
(5)
$${F}_{T}=\frac{EETC}{{C}_{T}}$$
(6)

where CR and CT are radon and thoron concentrations measured from pinhole twin cup dosimeters, respectively. EETC/EERC are the equilibrium equivalent concentrations of thoron and radon calculated from direct thoron/radon progeny sensors, i.e. DTPS/DRPS, respectively.

Estimation of total annual inhalation dose

The annual inhalation dose due to radon/thoron and their decay products was calculated by using Eq. (7) (UNSCEAR, 2000b):

$$\begin{aligned}D (\mathrm{mSv}/\mathrm{year})=&\;({C}_{R}\times 0.17+{C}_{T}\times 0.11+EERC\times 9\\&+EETC\times 40)\times 8760\times 0.8\times {10}^{-6}\end{aligned}$$
(7)

where 0.17/0.11/9/40 nSv (Bqh/m3)−1 are dose conversion factors for radon gas/thoron gas/radon decay products/thoron decay products, respectively (UNSCEAR, 2000a); 8760 h/year is the indoor occupancy time; and 0.8 is the indoor occupancy factor; 10−6 is the multiplication factor used for conversion of nanosieverts to millisieverts.

Results and discussion

Statistical interpretation of overall annual results

Annual average concentrations of radon, thoron and their decay products along with their descriptive statistics are summarised in Table 3. The radon concentration (CR) varied from 9.4 ± 1.6 to 43.4 ± 4.7 Bq/m3 with an average of 22.7 ± 3.2 Bq/m3, and the thoron concentration (CT) varied from 11.4 ± 3.1 to 145 ± 11 Bq/m3 with an average of 49.2 ± 6.1 Bq/m3. The frequency distribution and quartile-quartile (Q-Q) plot for radon and thoron data are shown in Fig. 5a, b, respectively.

Table 3 Measured values of indoor radon/thoron, equilibrium equivalent concentrations (EERC/EETC), equilibrium factors (FR/FT) and annual inhalation dose and annual effective doses (AEDR/AEDT)

In Fig. 5a, the Q-Q plot for radon concentration (right) is showing that both ends deviate from the straight line but the middle points follow a straight line. This verifies that the distribution is log-normal distribution (Fig. 5a) (left)). Skewness (0.5) and kurtosis (0.2) are showing that the distribution is fairly symmetric and light tailed, respectively (Table 3), and the histogram is positively skewed.

Fig. 5
figure 5

a Frequency distribution (left) and Q-Q plot (right) for annual average radon concentration. b Frequency distribution (left) and Q-Q (right) plot for annual average thoron concentration

The Q-Q plot (right) and frequency distribution (left) for the data of thoron concentration are shown in Fig. 5b. Similar to radon, deviations observed in the Q-Q plot and skewness and kurtosis values for thoron concentration data (Table 3) indicate that the distribution is log normal in nature. The measured average EERC ranged between 2.9 ± 0.5 and 17.8 ± 1.3 Bq/m3 with an average of 9.3 ± 0.9 Bq/m3, and the average EETC ranged between 0.2 and 1.5 ± 0.1 Bq/m3 with an average of 0.6 ± 0.1 Bq/m3. The frequency distribution for EERC and EETC data is depicted by Q-Q plots in Fig. 6a, b, respectively. The Q-Q plot for annual average EERC (Fig. 6a) shows that the data is symmetric with skewness 0.4 and light tailed with kurtosis − 0.2. Similarly, Fig. 6b shows that annual average EETC distribution is moderately skewed with skewness 1.0 and light tailed with kurtosis 0.5.

Fig. 6
figure 6

a Frequency distribution of annual average radon progeny concentration (EERC) and b thoron progeny concentration (EETC) (Bq/m3)

The reason for the observed variations in the data could be attributed to the difference in the geological condition of sampling sites, ventilation condition of the houses and building material used for the construction. The annual average thoron concentration has been found higher in comparison to the annual average radon concentration, similar to the trend of data seen in Kumar et al. (2017). The geometric mean values of annual average indoor concentrations of radon, thoron, EERC and EETC (with geometric standard deviations in brackets) were obtained to be 21.73 Bq/m3 (1.4), 44.89 Bq/m3 (1.6), 8.76 Bq/m3 (1.4) and 0.58 Bq/m3 (1.6), respectively. For indoor radon, 25% (1st quartile) of data lies below 17.9 Bq/m3 and 75% (3rd quartile) of data lies below 27.1 Bq/m3 with a median value of 21.6 Bq/m3. For indoor thoron, 25% (1st quartile) of data lies below 33.9 Bq/m3 and 75% (3rd quartile) of data lies below 61.5 Bq/m3 with a median value of 47.2 Bq/m3. EERC has 25% (1st quartile) of data below 6.8 Bq/m3 and 75% (3rd quartile) below 11.2 Bq/m3 with median 9.5 Bq/m3, while 25% of EETC (1st quartile) data is below 0.4 Bq/m3 and 75% (3rd quartile) is below 0.8 Bq/m3 with a median value of 0.5 Bq/m3.

The measured values of radon and thoron concentrations are within the safe limit of 300 Bq/m3 recommended by ICRP (2011). The estimated annual average concentration of radon (22.7 Bq/m3) was also found to be lower than the global average value of 40 Bq/m3 and the national average of 42 Bq/m3 (UNSCEAR, 2000a and Mishra et al., 2009). In contrast, the thoron (49.2 Bq/m3) concentration was found to be higher than the global average value of 10 Bq/m3 as well as the national average value of 12.2 Bq/m3 (UNSCEAR, 2000a and Mishra et al., 2009). The higher thoron in the study region could be due to the higher thorium content in the source term. The annual average equilibrium factor for radon was found to vary from 0.13 to 0.81 with an average of 0.47. The frequency distribution of the equilibrium factor of yearly averaged radon and its decay products is shown in Fig. 7a. Here, the distribution is normal distribution with a GM of 0.45 (GSD 1.36). The calculated average value of the equilibrium factor for radon and its decay products (0.47) has been found to be slightly higher than the global average value (UNSCEAR (2008)). The equilibrium factor evaluated for thoron ranged between 0.003 and 0.061 with an average of 0.021. Log-normal distribution has been found for the equilibrium factor of yearly averaged thoron and its decay products, which is shown in the frequency distribution graph in Fig. 7b. The average value (0.021) has been found to be smaller compared with the global average value of 0.1 (UNSCEAR, 1993). Variations in equilibrium factors and the reasons for the same have been discussed elsewhere (Porstendorfer, 1984; Jilek et al., 2010; Yu & Nikezic, 1996; Ramola et al., 20032016).

Fig. 7
figure 7

a Frequency distribution of annual average radon equilibrium factor and b thoron equilibrium factor

The calculated values of the annual average inhalation dose due to radon, thoron and their decay products has been found to vary from 0.3 to 1.6 mSv with an average of 0.8 mSv. The geometric mean value of the annual average inhalation dose was found to be 0.8 with GSD 1.4. Normal distribution of the data has been seen in the frequency distribution graph (Fig. 8). The annual average value measured is less than the world’s average inhalation dose of 1.2 mSv given by UNSCEAR (2000b).

Fig. 8
figure 8

Frequency distribution for total inhalation dose

The annual average effective doses due to radon and thoron decay products have been found to vary from 0.2 to 1.1 mSv with an average of 0.6 mSv and 0.1 to 0.4 mSv with an average of 0.2 mSv, respectively. Figure 9 shows the contribution of the total annual effective dose due to radon and thoron decay products. It can be seen that 75% and 25% of the annual average effective dose were contributed by radon and thoron decay products, respectively, for the study region. This shows the importance of decay product measurements for the study region.

Fig. 9
figure 9

Total annual effective dose due to radon and thoron progenies

Figure 10a represents the correlation plot for measured indoor radon and thoron concentration data while Fig. 10b shows a similar plot for measured radon and thoron decay product concentrations. As can be seen, a weak positive correlation (r = 0.14) was obtained for the gaseous measurement data whereas a low moderate positive correlation (r = 0.39) was obtained for the decay product concentrations. A positive moderate correlation with r values of 0.52 and 0.41 was obtained for the pairs radon gas-radon decay product concentration (Fig. 11a) and thoron gas-thoron gas concentration data (Fig. 11b), respectively. No correlation (r = 0.01) was obtained between equilibrium factors of radon and thoron (Fig. 12).

Fig. 10
figure 10

a Correlation between annual indoor radon and thoron concentrations and b annual indoor radon progeny and thoron progeny concentrations.

Fig. 11
figure 11

a Correlation between annual indoor radon and radon progeny concentrations and b annual indoor thoron and thoron Progeny concentrations.

Fig. 12
figure 12

Variation of equilibrium factors of radon/thoron in dwellings of Ludhiana district

Seasonal dependence of indoor radon/thoron and progeny concentrations

As mentioned earlier, the yearlong investigation was carried out in three cycles of 4 months to study the seasonal dependence of radon/thoron and decay product concentration. Detailed statistically estimated parameters of seasonal variation can be seen in Table 4, and the variation with respect to different seasons is shown as box whisker plots in Fig. 13. Measurements revealed that radon and thoron show a similar trend of seasonal variation as shown in Doi et al. (1994) and Mishra et al., (2004). Radon/thoron and radon decay product (EERC) concentrations have been found higher in the winter season (Fig. 13; Table 4). In the winter season, the geometric mean values of annual average indoor concentrations of radon, thoron, EERC and EETC (with geometric standard deviations in brackets) were obtained to be 26.6 Bq/m3 (1.5), 45.2 Bq/m3 (2.2), 9.5 Bq/m3 (1.6) and 0.5 Bq/m3 (2), respectively. The values for equilibrium factors (FR/FT), annual inhalation dose and annual effective doses (AEDER/AEDET) are also summarised in Table 4.

Table 4 Seasonal variation in statistical measured values of indoor radon/thoron, equilibrium equivalent concentrations (EERC/EETC), equilibrium factors (FR/FT), annual inhalation dose and annual effective doses (AEDER/AEDET)
Fig. 13
figure 13

Box whisker plots showing seasonal dependence of radon, thoron and progeny concentrations (Bq/m3)

The skewness values of radon, thoron and EERC are 0.9, 0.6 and 1 for the winter season, respectively. These values indicate that the distribution of the data is moderately skewed. For EETC, the skewness value of 1.3 shows highly skewed data. The kurtosis values for radon (1.4), thoron (− 0.2), EERC (0.5) and EETC (2.8) are less than 3, which indicates that the data is light tailed (Table 4).

In the winter season, due to cold weather, dwellers tend to keep the doors and windows mostly closed to increase the room temperature. Less ventilation leads to an increase in the concentration of radon/thoron gases in the room. Temperature inversion resulting in the trapping of gases near the surface also results in a high concentration in the winter season (Sathish et al., 2012; Sesana et al., 2003). The other reason may be the decrease in atmospheric pressure inside the rooms as compared to that outside, which increases the exhalation rate from the floor and walls (Mishra et al., 2004). For the study region, the radon gas concentration measured in 19% of dwellings was found to be higher than 40 Bq/m3 in the winter season. Similarly, for the case of thoron gas, the concentration in 14% of dwellings was measured to be above 100 Bq/m3 (Table 4). Measured values of indoor radon, thoron, radon decay product and thoron decay product concentrations have been found to be nearly the same for rainy and summer seasons (Table 4). The reason behind it may be the similar ventilation conditions of the room for both seasons. The average thoron decay product concentration has been found to be nearly the same in all seasons as 1.9 Bq/m3 (rainy), 1.9 Bq/m3 (winter) and 1.8 Bq/m3 (summer) (Table 4). The same trend of data can be seen in Omori et al. (2016) and Zhuo et al. (2000).

Impact of building materials

With a view to study the impact of building materials on indoor concentrations of gases and decay products, all the dwellings were divided into different categories as shown in Table 2. Division of dwellings for analysis was made on the basis of different types of floor, roof and wall material (Figs. 14 and 15a, b). Out of 106 dwellings, approximately 90% of dwellings had brick walls with cement plastering, 50% of dwellings had an RCC (reinforced concrete construction) roof and 32% had a cemented floor. Studies of Ningappa et al. (2008) and Sannappa et al. (2003) have revealed that the indoor radon concentration is mainly dependent on the building materials used for construction, ventilation condition of the house and types of soil beneath.

Fig. 14
figure 14

Radon concentration variation due to different floor materials

Fig. 15
figure 15

Radon and thoron concentrations due to a different wall materials and b different roofs

In the present study, a higher concentration of indoor radon has been found in dwellings with fired brick and mud-plastered floors. As fired bricks are also made from the local soil, both mud and fired bricks are major contributors of indoor radon concentration (Fig. 14). The higher concentration for these floors might be due to usage of radium-rich soil in mud plastering (UNSCEAR, 1988) and high porosity (Ningappa et al., 2008). On the other extreme, the lower porosity of mosaic tiles resulted in a lower radon concentration (Fig. 14).

This investigation revealed that most of the roofs were made up of wooden/thatched, bricks and RCC materials. A higher radon/thoron concentration has been found in wooden/thatched roof houses, and a lower concentration has been found in RCC roof houses (Fig. 15b).

Figure 16 demonstrates that roof/wall combinations of different building materials have significant impact on the thoron concentration found in the room. As detectors were deployed near walls and roofs, these were the main contributor of thoron gas rather than the floor due to the short half-life of thoron.

Fig. 16
figure 16

Thoron concentration variation among different roof and wall combinations. WM wooden roof/mud wall, BM fired brick roof/mud wall, BB fired brick roof and wall, BC fired brick roof/cemented wall, KC RCC roof/cemented wall, WC wooden roof/cemented wall

Footprints of mud-plastered walls can be seen in both combinations with wooden and brick roofs as wooden roof, mud and fired brick floors have shown a high concentration of thoron in the room figured out earlier. The fired brick roof and wall combination closely resembles fired brick roof and mud wall combinations as these bricks are also made with the thorium-rich local soil (UNSCEAR, 1988). Combinations of fired brick roof, RCC roof and wooden roof made with cement walls have shown a lower thoron concentration than others.

The final aspect has been studied broadly by categorising 106 houses into kaccha houses and pakka houses. Categorisation has been made on the point that those houses that have used mud for the roof/wall/floor are kaccha houses and the houses made with materials other than mud are pakka houses. Figure 17 illustrates that significant difference can be seen in the thoron concentration of kaccha houses and pakka houses. Kaccha houses have higher concentration of radon and thoron than pakka houses. Radium/thorium-rich soil is the main reason behind the higher concentration of radon/thoron in kaccha houses or mud houses (Kumar et al., 2014, Kumar and chauhan 2014).

Fig. 17
figure 17

Radon/thoron concentration in kaccha and pakka houses

Influence of ventilation condition

To study the effect of ventilation on the indoor concentrations of gases and progeny, dwellings were divided qualitatively into three categories: poor, average and good ventilation. The selection has been made on the basis of number of doors and windows in the room. Poorly ventilated rooms were those who have only one door, those with one door with one side window are considered average ventilated rooms and rooms with two doors and two side windows are considered well-ventilated rooms. With one door, air is stuck inside and cannot easily leave the room. It causes an increase in the air pollutants inside the room. Therefore, these rooms are termed as poorly ventilated rooms. In fully ventilated rooms (rooms having two doors and two windows), air circulates properly in the rooms and takes away all the pollutants outside and fresh air inside the rooms. Likewise, the rooms with one door and one window are considered average-ventilated rooms depending upon the positions of the window.

The study has revealed that the radon concentration has been reduced with increasing ventilation in the room (Mehta et al., 2015) and same as with thoron concentration (Fig. 18). Higher radon concentrations in poorly ventilated rooms have been also reported in Mehra and Bala (2013) and Mehta et al. (2015), and a high thoron concentration in poorly ventilated rooms can be seen in Sathish et al. (2012). This is due to the difference in their half-lives. Thoron progeny has been found almost same for all ventilation conditions, which can also be seen in Ma et al. (1997).

Fig. 18
figure 18

Radon/thoron and their progeny concentration under different ventilation conditions

Influence of room type

An attempt has also been made to study the variation of radon and thoron in different types of rooms, i.e. bedroom, hall (living room) and kitchen. It is shown that the radon concentration is found to be different in all room types because of different ventilation effects (Fig. 19a) and a higher concentration has been found in bedrooms relative to those in halls and kitchens. The probable reason is that bedrooms are less ventilated as compared to halls and kitchens. The thoron concentration has been found to be approximately the same in all due to the short half-life (Fig. 19b) as ventilation conditions do not affect the thoron concentration. Additionally, exhaust fans have been almost found in most of the kitchens, which can be the reason for the low radon concentration in kitchens.

Fig. 19
figure 19

a Variation of radon and b thoron concentrations due to different rooms

Comparison between indoor and outdoor terrestrial gamma radiation doses

The results of indoor and outdoor gamma radiation doses estimated during this study are summarised in Table 5. Indoor and outdoor absorbed dose rates varied from 113.1 to 217.5 nGy/h and 104.4 to 200.1 nGy/h, which are found to be higher than the world’s average of 60 nGy/h ranging from 10 to 200 nGy/h (UNSCEAR, 2000b and Tuskin et al., 2009). The average annual effective dose for indoor and outdoor was obtained to be 0.82 mSv and 0.18 mSv, respectively, which are less than the ICRP (1990) recommended limit of 1 mSv. The indoor to outdoor dose ratios were ranging between 3.11 and 6.46.

Table 5 Average indoor and outdoor gamma level, absorbed dose rate and annual effective dose equivalent in different houses of the Ludhiana district

Conclusion

This study has been conducted in Ludhiana district of Punjab state, India. A total of 106 houses in 42 villages have been examined for assessment of radon/thoron and their progeny. This study was performed in order to explore the factors that are accountable for radon/thoron and their decay product concentration variations in the indoor environment. The indoor/outdoor terrestrial gamma radiation level has also been measured for these selected locations in this study. The indoor gamma radiation dose has been found to be 86% higher than the outdoor dose. The average indoor radon and thoron concentrations have been found to be ranging from 9.4 ± 1.6 to 43.4 ± 4.7 Bq/m3 and 11.4 ± 3.1 to 145 ± 11 Bq/m3, respectively.

The average annual inhalation dose has been found to be 0.8 mSv/year, which is less than the world’s average inhalation dose, i.e. 1.2 mSv/year (UNSCEAR, 2000b). The contribution to the annual average effective dose due to radon progeny and thoron progeny was found to be 75% and 25%, respectively. In seasonal behaviour, higher radon and thoron concentrations have been found in the winter season whereas bedrooms of the study region showed higher concentrations than those measured in halls and kitchens. Both of these observations pertain to the role of ventilation in ascertaining the concentration levels.