Introduction

Cardiac amyloidosis (CA) has a poor prognosis [1], so diagnosis for treatment decisions is important. Although endomyocardial biopsy is the most accurate method for the diagnosis of CA, the procedure has risks due to its invasiveness [2]. Echocardiography is the most commonly used non-invasive imaging method, but it is insensitive in the early stage of CA [3]. Several studies have shown that CA can be diagnosed using cardiovascular magnetic resonance (CMR) with late gadolinium enhancement (LGE) images because of its characteristic enhancement pattern, including diffuse, global subendocardial enhancement [4,5,6], but CA might show atypical features, such as patchy or focal enhancement [7]. The most common LGE patterns of hypertrophic cardiomyopathy (HCMP) are patchy and multifocal distributions [8,9,10], so differentiating between CA and HCMP can be difficult if the CA does not show specific LGE patterns. In addition, amyloid deposition shortens the T1 time of the myocardium, making it difficult to identify the appropriate nulling time during acquisition of the LGE images [4].

T1 mapping and extracellular volume (ECV) have been introduced as quantitative parameters according to the development of the CMR techniques [11, 12]. Recently, studies have compared patients with CA, HCMP, or non-amyloid cardiomyopathy using values of native T1 mapping and ECV [13,14,15]. However, additional acquisition time is required to obtain T1 mapping, and acquiring T1 mapping images both before and after injection of gadolinium contrast is required to calculate ECV. The inversion time (TI) scout images, which are a type of routine image, generally are used to obtain LGE images corresponding to the optimal nulling time. From the TI scout images, we can determine the nulling time of the LV cavity and myocardium. Indeed, assessment of the temporal order of nulling on the TI scout images in patients with CA has been used to establish the characteristics of CA [16]. We hypothesized that quantitative parameters obtained from the TI scout images will demonstrate characteristic values for CA patients. Thus, the purpose of this study was to compare the native T1, ECV, and TI parameters on CMR imaging between patients with CA or HCMP and to evaluate whether the TI parameter can replace the ECV as a quantitative CMR parameter.

Methods

Patient population

Between October 2011 and April 2016, 46 consecutive patients with histopathologically diagnosed CA of the light-chain type were included in this study. All patients underwent CMR examination at the time of pathologic diagnosis. The mean interval between pathologic diagnosis and CMR study was 2.7 ± 2.4 days (median 2 days; range 0–10 days). In addition, 30 consecutive patients with clinically diagnosed HCMP of a concentric or septal type and ten asymptomatic subjects who underwent screening CMR for a health checkup at the Health Promotion Center of our institute were included in this study. None of ten control subjects had hypertension or diabetes. This study was approved by the Institutional Review Board at Samsung Medical Center, one of the major tertiary referral centers in Seoul, Korea, and the requirement for informed consent for the use of patient data was waived.

CMR imaging protocol

All patients underwent cardiac MRI with a 1.5 T scanner (Magnetom Avanto, Syngo MR B17 version; Siemens Healthcare, Erlangen, Germany) and a 32-channel phased-array receiver coil during repeated breath-holds. CMR scans consisted of localizing images (axial, coronal, and sagittal), cine scans, native T1 mapping, late gadolinium enhancement scans, and post-T1 mapping.

After localization, cine images of the left ventricle (LV) were acquired using a steady-state free precession (SSFP) sequence on 4-, 3-, and 2-chambers and short-axis (SA) views for obtaining 30 contiguous SA slices to include the entire LV with a 6-mm slice thickness and 4-mm intersection gaps. Balanced SSFP cine images with the generalized auto-calibrating partially parallel acquisitions (GRAPPA; Siemens Medical Solutions, Erlangen, Germany) reconstruction algorithm were obtained during multiple breath-holds. Cine images were acquired with the following parameters: repetition time/echo time, 3.31 ms/1.31 ms; flip angle 72°; phases per cardiac cycle 30; field of view 240 × 300 mm2; matrix 256 × 150; and generalized auto-calibrating partially parallel acquisitions (GRAPPA) acceleration factor, 2.

T1 mapping images were acquired with modified Look-Locker inversion-recovery (MOLLI) sequence. The pre-contrast MOLLI was composed of 5 images over 5 heartbeats after the first inversion pulse and 3 images over 3 heartbeats after the second inversion pulse [a 5(3)-3 protocol with a pause of 3 heartbeats]. Finally, eight images during 11 heartbeats were obtained, and T1 maps were generated after registration of individual inversion images with inline motion correction prior to non-linear curve fitting using the 3-parameter signal model. The post-contrast MOLLI scheme was 4(1)-3(1)-2 over 11 heartbeats with three inversion pulses. Finally, nine images with different TIs were acquired. The following scan parameters were used: slice thickness 8 mm; flip angle 35°; field of view 360 mm × 307 mm; initial TI 120 ms; TI increment 80 ms; voxel size 1.87 × 1.88 × 8 mm3; TR (Repetition time)/TE (Echo time), 2.4/1.01 ms; partial Fourier, 7/8; and GRAPPA parallel imaging factor, 2. Post-contrast images were acquired at the same positions as the pre-contrast images within 15 min after the injection. All scans were carried out by qualified technicians and supervised by an experienced radiologist.

The TI scout gradient echo sequence had the following parameters: 8 mm thick, mid ventricle level, TR 23.58 ms, TE 1.11 ms, flip angle 30°, generated using 20 or 30 ms increments (depending on heart rate) from 85 to 795 ms.

Anatomical and functional analysis of the left ventricle

CMR image analyses were performed by one experienced investigator (Y.K) blinded to the clinical results. Septal and posterior wall thicknesses were measured on SA images at the LV mid-ventricular level. Quantitative evaluation of LV volume and mass at end diastole and end systole was performed. Frames with the largest and smallest ventricular volumes were chosen as end diastole and end systole, respectively. The LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), LV ejection fraction, stroke volume (SV), cardiac output, and LV mass were calculated from the SA cine images using ARGUS™ software (Siemens Healthcare, Erlangen, Germany) with semiautomatic contour detection. Manual correction of the automatically rendered endo- and epicardial contours was performed in all data-sets, and the papillary muscles and myocardial trabeculations were included in the ventricular cavity. The LV mass was measured by multiplying the sum of total LV myocardial volume from the cine images by specific gravity of the myocardium.

Analysis of T1 mapping with ECV quantification and TI scout

For the acquisition of myocardial T1 values, ROIs for signal intensity were drawn manually in the septum of the pre- and post-contrast T1 maps at the mid-ventricular level. The T1 value of blood was measured by positioning a circular ROI in the LV cavity while avoiding the papillary muscle. The ECV of the myocardium was calculated as follows: \({\text{ECV}}\;(\% )=\left( {{{\Delta {\text{R}}{1_{\text{m}}}} \mathord{\left/ {\vphantom {{\Delta {\text{R}}{1_{\text{m}}}} {\Delta {\text{R}}{1_{\text{b}}}}}} \right. \kern-0pt} {\Delta {\text{R}}{1_{\text{b}}}}}} \right) \times \left( {1 - {\text{hematocrit}}\;{\text{level}}} \right) \times 100\), where R1 is 1/T1; R1m is the R1 of the myocardium; R1b is the R1 of the blood; and ΔR1 is the change in relaxivity. The change in relaxivity (ΔR1) was determined with the following equation: ΔR1 = R1post − R1pre, where R1post and R1pre are the R1 after and before contrast administration, respectively [17, 18].

The TI scout used for delayed hyper-enhancement was the time to complete nulling of the signal of the myocardium. TI scout images were acquired at 10 min after contrast injection. The temporal order of nulling of the contrasted blood pool in the LV cavity and myocardium (interventricular septum) was recorded in each case from the TI scout sequence. We compared the TI of the nulling point between the CA, HCMP, and control groups. We also analyzed the intervals of TI obtained from the LV cavity and myocardial septum in those groups (Fig. 1).

Fig. 1
figure 1

TI scout images and TI curve in patients with cardiac amyloidosis and hypertrophic cardiomyopathy. Inversion time (TI) scout images with ROI measurement of LV cavity (yellow circle) and myocardium (red circle) and TI curve in patients with cardiac amyloidosis and hypertrophic cardiomyopathy. a and b TI interval (TI value of the myocardial septum—TI value of the left ventricular cavity, arrow in b), − 22 ms in a 52-year-old man with cardiac amyloidosis. c and d TI interval (arrow in d), 70 ms in a 58-year-old man with hypertrophic cardiomyopathy. [LV left ventricle, RV right ventricle on short-axis views (a, c)]

Statistical analysis

Statistical analysis was performed with SAS version 9.4 (SAS Institute, Cary, NC) and R 3.4.0 (Vienna, Austria). The clinical features and CMR parameters between the CA, HCMP, and control groups were compared using Fisher’s exact test for categorical variables and Kruskal–Wallis test for continuous variables. Comparisons of TI between the CA, HCMP, and control groups were performed by ANOVA and Kruskal–Wallis tests; for the post-hoc analysis, we used Mann–Whitney U test with Bonferroni correction. Receiver-operating characteristic (ROC) curve analysis was used to test the predictive performance of TI and intervals of TI between the LV cavity and myocardium and the results were presented as the area under the ROC curve (AUC) and 95% confidence interval (CI). The comparison of AUC for diagnostic performance among CMR parameters was analyzed by using the DeLong method [19]. The correlation between the representative parameter, such as ECV and other CMR parameters, was calculated with Spearman’s correlation coefficient. Interobserver agreement for the measurement of TI scout and T1 mapping was analyzed with intraclass correlation coefficients (ICCs). ICC values of 0.20 or less were indicative of poor agreement; 0.21–0.40 was considered fair; 0.41–0.60, moderate; 0.61–0.80, good; and 0.81 or more, excellent correlation. In all statistical analyses, p values < 0.05 were considered statistically significant.

Results

Patient characteristics

Patient characteristics for all groups are summarized in Table 1. There were no significant differences in age or sex among the CA, HCMP, and control groups. Body surface area was about 0.1 m2 higher in patients with HCMP than in other groups (p < 0.001). Patients with CA had 5–6% significantly lower hematocrit level than did patients with HCMP (p < 0.001). Among the CMR parameters, left ventricular mass index was lower in patients with CA than patients with HCMP by 30 g/m2 (p < 0.001). There was a significant difference between patients with CA and HCMP in LVEF, LVEDV and SV among the remaining CMR parameters (all p < 0.001).

Table 1 Basic characteristics of CA, HCMP, and control groups

TI of the nulling point and TI interval obtained from the myocardium and LV cavity in CA, HCMP, and control groups

There were significant differences in TI in the myocardial septum among the CA, HCMP, and control groups (Fig. 2a). Patients with CA had significantly decreased TI of the myocardium (192.1 ± 33.2 ms) compared to patients with HCMP (234.6 ± 29.0 ms, p < 0.001) and controls (244.6 ± 19.8 ms, p < 0.001). The TI of the LV cavity was increased in patients with CA (203.5 ± 36.9 ms) compared to patients with HCMP (168.4 ± 35.7 ms, p < 0.001) and controls (160.7 ± 18.1 ms, p < 0.001) (Fig. 2b). There were no statistically significant differences in the TI of the myocardium or the TI of the LV cavity between HCMP patients and controls (p = 0.320 and 0.937, respectively) (Table 2).

Fig. 2
figure 2

TI values in hypertrophic cardiomyopathy, cardiac amyloidosis, and healthy controls. Inversion time (TI) values obtained from the TI scout of the a myocardial septum and b left ventricular cavity in three groups of patients. Comparisons between subgroups: a Hypertrophic cardiomyopathy (HCMP) versus cardiac amyloidosis (CA), p < 0.001; CA versus control, p < 0.001; HCMP versus control, p = 0.320. b HCMP versus CA, p < 0.001; CA versus control, p = 0.001; HCMP versus control, p = 0.937

Table 2 Comparison with CMR parameters between CA, HCMP, and control groups

The TI interval differed significantly between the myocardium and the LV cavity (Fig. 3). The CA group had a decreased TI interval (-11.5 ± 28.4 ms, p < 0.001) compared to the HCMP group (66.2 ± 25.4 ms). The TI interval differed significantly between the CA and control groups (83.9 ± 16.8 ms, p < 0.001), but not between the HCMP and control group (p = 0.096).

Fig. 3
figure 3

TI interval in hypertrophic cardiomyopathy, cardiac amyloidosis, and healthy controls. Inversion time (TI) intervals (TI value of the myocardial septum—TI value of the left ventricular cavity) in three groups of patients. Comparisons between subgroups: Hypertrophic cardiomyopathy (HCMP) versus cardiac amyloidosis (CA), p < 0.001; CA versus control, p < 0.001; HCMP versus control, p = 0.096

Native T1 mapping and ECV in CA, HCMP, and control groups

Native T1 mapping differed significantly between the CA (1170.5 ± 86.4 ms), HCMP (1059.5 ± 63.4 ms), and control groups (965.0 ± 49.9 ms, p < 0.001). Posthoc analyses also revealed significant differences between the CA and HCMP groups, CA and control groups, and HCMP and control groups (all p < 0.001) (Fig. 4a). Patients with CA showed increased ECV values (56.7 ± 12.2) compared to patients with HCMP (28.5 ± 5.8, p < 0.001) and controls (24.8 ± 4.7, p < 0.001) (Fig. 4b). The ECV differed significantly between the HCMP and control groups (p = 0.016).

Fig. 4
figure 4

Native T1 (a) and ECV (b) in hypertrophic cardiomyopathy, cardiac amyloidosis, and healthy controls. Comparisons between subgroups: a Hypertrophic cardiomyopathy (HCMP) versus cardiac amyloidosis (CA), p < 0.001; CA versus control, p < 0.001; HCMP versus control, p < 0.001. b HCMP versus CA, p < 0.001; CA versus control, p < 0.001; HCMP versus control, p = 0.016. ECV extracellular volume

Interobserver reliability was excellent for the measurement of TI scout and native T1 mapping [ICCs for TI scout, 0.936 (CI 0.866–0.970); for native T1 mapping, 0.898 (CI 0.786–0.952)].

Comparison of TI values, native T1 Mapping and ECV for differential diagnosis between HCMP and CA

In the comparison of diagnostic performance of the TI interval (myocardium-LV cavity), native T1 mapping, and ECV between HCMP and CA, ROC curve analysis (Fig. 5) showed an AUC of 0.975 for the TI interval, which was not significantly different from that of the ECV (0.980, p = 0.776). The AUC for the TI interval was significantly greater than that for native T1 mapping (0.845, p = 0.004). The optimal cutoff values obtained from Youdens index were 25 for the TI interval, 1130.9 for the native T1 value, and 40.1 for the ECV. Each sensitivity and specificity is as follows: TI interval, 0.967, 0.891; native T1, 0.761, 0.833; ECV, 0.957, 0.933.

Fig. 5
figure 5

ROC curve for native T1, ECV, and TI interval. Receiver-operating characteristic (ROC) curves to detect the diagnostic performance of native T1, extracellular volume (ECV) and inversion time (TI) interval for differential diagnosis between cardiac amyloidosis and hypertrophic cardiomyopathy. AUC area under the curve

Spearman rank correlations were performed to identify which CMR parameters, such as TI value and LV mass index, were correlated with ECV. There was a strong correlation between ECV and TI interval (r = − 0.724, p < 0.001) and a moderate correlation between the TI of the myocardium and ECV (r = − 0.581, p < 0.001) (Table 3).

Table 3 Correlation of CMR parameters and ECV

Discussion

The main finding of our study was that the TI interval between the myocardium and LV cavity showed a higher AUC value (0.975) than did the native T1 (0.845, p = 0.004) and showed non-inferiority to the ECV (0.980, p = 0.776) for differential diagnosis between CA and HCMP. In the correlation analysis of CMR parameters and ECV, the TI interval showed the strongest correlation with ECV (r = − 0.724, p < 0.001).

Pandey et al. [16] reported diagnostic utility for the presence of myocardial amyloidosis using the pattern of nulling on the TI scout sequence of CMR and analyzed the TI scout sequence with specific attention to the order of temporal nulling between the myocardium, blood pool, and spleen. They found that patients with myocardial amyloid infiltration null the myocardium before the blood pool, while non-amyloid patients null the blood pool before the myocardium. On the basis of their findings, we explored a new CMR parameter using TI scout and T1 mapping images. We found two distinctive results: (1) Patents with CA had significantly decreased TI of the myocardium (192.1 ± 33.2 ms) compared to patients with HCMP (234.6 ± 29.0 ms, p < 0.001). This finding can be explained by shortening of the TI caused by higher ECV in CA patients than HCMP patients. Previous investigators [12, 13, 15] have also found that patients with CA have significantly higher ECV than patients with HCMP. (2) Patients with CA showed increased TI in the LV cavity (203.5 ± 36.9 ms), compared to patients with HCMP (168.4 ± 35.7 ms, p < 0.001) or healthy controls (160.7 ± 18.1 ms, p = 0.001). The pathophysiology of this phenomenon is not well understood, but Maceira et al. [20] reported that blood gadolinium clearance is significantly faster in amyloid patients, resulting in a higher blood T1 over time and a lower T1 of the myocardium compared to controls. These opposing effects result in a markedly smaller difference in TI between the blood and myocardium in the amyloid patients compared to healthy controls. It can be assumed that an increased amyloid load affects renal function, resulting in disturbance of gadolinium clearance.

To our knowledge, this is the first study to report an increased TI of the blood pool in patients with CA compared to healthy controls and HCMP patients. We speculated that the TI interval between the myocardium and LV cavity would differ significantly between patients with CA and HCMP. Indeed, we revealed a remarkable difference in TI interval between patients with CA (− 11.5 ± 28.4 ms) and those with HCMP (66.2 ± 25.4 ms, p < 0.001). Thus, the TI interval might have potential as a method for diagnosing cardiac involvement of amyloidosis and differential diagnosis for HCMP. In our study, we reported an AUC of 0.975, which represents the diagnostic performance of the TI interval between the myocardium and LV cavity. This AUC value, was similar to other CMR parameters, such as ECV, which have been highly useful in the diagnosis of cardiac amyloidosis (AUC, 0.980, p = 0.776), and superior to the native T1 (AUC, 0.845, p = 0.004).

Several previous studies of CMR have investigated non-invasive techniques for the diagnosis of myocardial amyloidosis, and the usefulness of CMR has been noted [13,14,15,16, 21,22,23,24]. Previous investigators [13, 14] found that T1 mapping can differentiate patients with cardiac involvement of amyloidosis from normal controls with high diagnostic accuracy and from patients with hypertrophic cardiomyopathy or aortic stenosis, two other conditions causing LV hypertrophy. It is well known that cardiac involvement in amyloidosis leads to excessive accumulation of extracellular contrast agents and a subsequent marked increase in ECV [15, 21, 23]. The ECV is considered to be a more accurate and reliable parameter than the native T1 [12, 21, 22]. We found a strong correlation between the diagnostic performance of ECV and TI interval in a Spearman rank correlation test. Thus, the TI interval may be considered as another potential parameter, especially when T1 mapping is not available. However, since the number of patients in our study was relatively small, the clinical application of this parameter should be verified in larger cohort studies.

Our study had several limitations, mainly its single-center, retrospective study design. These aspects of our study design limit the generalizability of the findings and raise the possibility of selection bias. In addition, the sample size was relatively small. However, we tried to include all patients with histopathologically proven CA by endocardial biopsy. Second, we analyzed multiple CMR parameters at the interventricular septum and interpreted these as representative of the whole myocardium. Third, a comparison with echocardiography was not performed because it was outside the scope of the study.

Conclusions

The diagnostic performance of the TI interval between the myocardium and LV cavity was superior to that of the native T1 and non-inferior to that of the ECV for differential diagnosis between CA and HCMP. In addition, the TI interval showed a strong correlation with ECV. We suggest that the TI interval has the potential to replace ECV as a quantitative CMR parameter when T1 mapping images are not available.