Abstract
To derive and validate a practical patient-specific dose protocol to obtain an image quality, expressed by the image noise, independent of patients’ size and a better radiation dose justification in coronary CT angiography (CCTA) using prospective ECG triggering. 43 patients underwent clinically indicated CCTA. The image noise, defined as the standard deviation of pixel attenuation values in a homogeneous region in the liver, was determined in all scans. Subsequently, this noise was normalized to the radiation exposure. Next, three patient-specific parameters, body weight, body mass index and mass per length (MPL), were tested for the best correlation with normalized image noise. From these data, a new dose protocol to provide a less variable image noise was derived and subsequently validated in 84 new patients. The normalized image noise increased for heavier patients for all patients’ specific parameters (p < 0.001). MPL correlated best with the normalized image noise and was selected for dose protocol optimization. This new protocol resulted in image noise levels independent of patients’ MPL (p = 0.28). A practical method to obtain CCTA images with noise levels independent of patients’ MPL was derived and validated. It results in a less variable image quality and better radiation exposure justification and can also be used for CT scanners from other vendors.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
For patients with suspected stable coronary artery disease it is recommended to perform non-invasive testing prior to invasive coronary angiography [1]. In patients with a low to intermediate pre-test probability for coronary artery disease, use of computed tomography coronary angiography (CCTA) is advised [1]. To reduce the high radiation burden associated with CCTA, prospective ECG-triggering was introduced [2]. This technique activates the X-ray tube only in the end-diastolic phase rather than throughout the cardiac cycle, resulting in dose reductions up to 90 % [3, 4]. However, prospective ECG-triggering cannot be used in combination with automatic anatomy-based tube-current modulation which corrects for the varying patients’ size [4]. This correction ensures a less variable image quality and, hence, sufficient diagnostic CCTA image quality with a minimum radiation exposure. Only few CT scanners have the possibility to automatically adjust the tube settings based on a preceding image, as alternative to anatomy-based tube-current modulation, to correct for the varying patients’ size. Hence, manual adjustment prior to imaging is required in most scanners [3–6].
Multiple CCTA protocols are proposed to adapt for varying patient size to obtain a less variable image quality [7–14]. Most of them modify tube settings based on image noise found in a preceding scan, for example a bolus scan. Although these protocols result in a less variable image noise, it is cumbersome to implement them in clinical practice. Consequently, most institutes nowadays use protocols that are empirically adjusted, using body mass index (BMI) or weight, not necessarily resulting in a constant level of image noise. However, image noise is closely related to image quality [7–11]. In particular, a constant image noise will result in a less variable image quality. But only few studies describe clinical applicable dose protocols for specific CT imaging configurations that result in less variable image noise [10–13]. Moreover, a general method to derive these protocols for different CT settings or scanners is lacking. Therefore, these methods cannot be enrolled at other centers without additional efforts. Hence, the aim of our study was to demonstrate how to derive and validate a practical patient-tailored CCTA imaging protocol using prospective ECG-triggering in order to obtain an image quality, expressed by the image noise, independent of patient’s size and thereby providing a better radiation dose justification.
Materials and methods
Study population
All 129 retrospectively included patients underwent clinically indicated prospective ECG-triggered CCTA (Discovery NM 570c, GE Healthcare). The first 45 patients were consecutively included to derive a patient-tailored dose protocol (further referred to as group A). For the validation part of this study, 84 additional patients were included (further referred to as group B), of which 43 patients were included consecutively. To obtain a population in the full expected range of body mass per body length (MPL) to demonstrate the validity of the protocol an additional 41 patients were included to obtain at least 10 patients in each of the following MPL categories: <40, 40–45, 46–50, 51–55 and >55 kg/m. These patients were consecutively included for each category. Multiple patient-specific parameters and coronary artery disease risk factors were collected for all patients prior to scanning. As this study was set up in a retrospective manner, no approval by the medical ethics committee was required. All patients provided written informed consent for the use of their data for research purposes.
Patient preparation and image acquisition
Patients were instructed to remain fasting for 3 h prior to acquisition. Patients with heart rates between 49 and 59 or >59 beats per minute were requested to take 50 or 100 mg metoprolol orally, respectively, 1 h prior to acquisition. Diazepam (10 mg) was administered when clinically indicated to calm the patients for additional heart rate reduction.
Patients were scanned in supine position, with arms placed above their head. A scout image (120 kV, 10 mA) was acquired prior to the bolus acquisition to determine the scan field. Bolus delay was determined by making 10 consecutive acquisitions in 20 s (120 kV, 60 mA). Next, patients were administered two puffs (2 × 0.4 mg) of nitroglycerine sublingual, unless contraindicated.
All CT-scans were prospectively ECG-triggered at 75 % of the RR interval and were acquired using the following parameters: collimation 64 × 0.625 mm, rotation time of 0.35 s and a tube voltage depending contrast flow of 4 ml/s at 100 kV, 5 ml/s at 120 kV, and 6 ml/s at 140 kV (Optiraytm, Mallinckrodt). The standard applied BMI depending protocol in our institution, as applied in group A, is shown in Table 1. The CT scans were reconstructed using filtered back projection with a slice thickness of 0.625 mm, 512 × 512 matrix and a pixel size of 0.35 mm (Xeleris software, GE Healthcare).
Deriving a patient-specific CCTA protocol
The image noise, defined as the standard deviation of pixel attenuation values in a visually homogeneous region of interest (ROI), was measured in the most cranial part of the liver parenchyma in each scan, as illustrated in Fig. 1. Next, image noise was fitted to multiple patient-specific parameters (P) which were considered easy applicable in daily use; body weight, BMI and MPL, to determine a possible increase in image noise for heavier patients (see Table 1).
To determine the relation between image noise and patients’ size for a fixed radiation dose, the measured image noise was normalized to the squared root of the applied computed tomography dose index (CTDI) expressed in mGy. This was based on the formula previously used by Menke et al. [15]:
Here σ is the measured image noise, µ the mean attenuation coefficient of the region at a defined tube voltage (cm−1) and d the axial diameter of the patient (cm). Subsequently, for each patient a normalized value of image noise (σnorm) was determined using:
Next, the relations between the σnorm and multiple patient-specific parameters (P) were investigated to find the parameter best explaining the relation between σ and P. Therefore, σnorm was fitted using a linear function (σfit):
Here, a and b are fit parameters.
Patient-specific CTDI
When combining Eqs. 2 and 3, with σnorm described by the linear function σfit, we obtained a new CTDI (CTDIapply):
Here σC is the desired constant image noise, which was set equal to the average image noise measured in all patient scans in this study. Ideally, the noise becomes independent of the patient examined when applying the new CTDI using the appropriate tube settings (kV and mA). The choice of tube voltages was based on tube voltage guidelines using weight and BMI; 100 kV below 90 kg or 30 kg/m2 corresponding to a MPL of 45 kg/m, 140 kV for severely obese patients (MPL > 60 kg/m) and 120 kV for the remainder of the patients [4]. Next, the tube currents were derived using these tube voltages to obtain CTDIapply. Yet due to the maximum tube current achievable on the CT scanner, a higher tube voltage of 120 kV was used for MPLs between 45 and 52.5 kg/m to obtain CTDIapply.
To ensure validity of the protocol, it was derived for patients with a body weight between 60 and 130 kg, BMI between 17 and 35 kg/m2 or MPL between 35 and 60 kg/m. Patients outside this pre-specified range received the minimal or maximal recommended radiation dose, i.e. a patient with a MPL of 30 kg/m received the dose corresponding to a patient of 35 kg/m. The effective dose was estimated using the mean irradiated body length of 13.7 cm and the thorax conversion factor of 0.017 mSv/mGy/cm [16].
Validation
The optimized patient-specific CCTA protocol was implemented as a new routine clinical protocol. Next, to examine if the image noise was independent of patients’ size using the new protocol, the best explaining parameter P was correlated to the image noise for patients within the pre-specified range in groups A and B.
Statistics
All patient characteristics for groups A and B were presented as mean ± standard deviation (sd) and compared using the χ2 and unpaired t tests using Stata software (StataSE 12.0). To test if the regression coefficients of the σfit for each patient-specific parameter P differed significantly from zero, implying a significant correlation between σ and P or σnorm and P, t tests were performed. Coefficients of determination, R2, were determined for all fits and compared using the Hotelling–Williams test. Using the results of R2 and the Hotelling–Williams tests, the patient-specific parameter best explaining the σnorm was selected for the validation study.
The level of statistical significance was set to 0.05 for all statistical analyses.
Results
The baseline characteristics of all included patients are summarized in Table 2.
Deriving a patient-specific CCTA protocol
The mean measured image noise (σ) and normalized image noise (σnorm) in group A was 57 ± 14 HU and 162 ± 52 HU mGy1/2, respectively. Despite the applied BMI depending protocol in group A, an increase in image noise was observed for increasing values of all tested patient-specific parameters (p ≤ 0.002), as illustrated in Fig. 2.
The regression coefficients of the fits describing the σnorm as a function of all three patient-specific parameters were also found to be statistically different from zero (p < 0.001), as illustrated in Fig. 3. The calculated fit parameters a and b for all patient-specific parameters are shown in Table 3. MPL had a significantly stronger correlation with the normalized image noise than body weight (p = 0.03) but a similar correlation as BMI (p = 0.37). Yet based on its R2 value, MPL was used in the validation study.
Patient-specific CTDI
Using Eq. 4 and the fit parameters a and b, the recommended patient-specific radiation dose using MPL can be described by:
The derived radiation dose table describing the proposed CTDIapply is shown in Table 4. In comparison to the protocol as applied in group A, a lower CTDI is recommended for leaner patients and a higher CTDI for more obese patients, as illustrated in Fig. 4.
Validation
The mean image noise in group B was 50 ± 12 HU and the normalized image noise, σnorm, was 147 ± 57 HU mGy1/2. Different relations between image noise and MPL were observed for groups A and B, as illustrated in Fig. 5. Whereas the slope of the regression line differed significantly from zero for group A (p = 0.007), this was not the case for group B (p = 0.28).
Discussion
The present study demonstrates a method to derive and validate a practical patient-specific prospective ECG-triggered CCTA protocol to overcome the increasing image noise in heavier patients. The protocol is based on the relation between MPL and image noise normalized to the radiation exposure and can also easily be adopted on CT scanners from other vendors, independent of the acquisition and reconstruction settings used. Hence, it provides a useful alternative to CT scanners which can automatically adjust the tube current and voltage based on a preceding scan in combination with prospective ECG-triggering. Applying an MPL dependent protocol resulted in constant image noise levels, independent of patients’ size.
Our findings are in agreement with previous studies proposing patient-specific protocols for prospective ECG-triggered CCTA [7–14, 17]. Most of these studies propose correction protocols based on the attenuation or image noise in preceding scans, for example in a bolus scan. This approach is also used in the newest generation of CT scanners which can automatically adjust the tube current and voltage based on the scout in combination with prospective ECG-triggering. It could result in less variation in image noise than when using a patient-specific parameter as we derived [7–9, 18]. However, our method has several major advantages over the methods which are based on a preceding scan. It can easily be applied on CT scanners from other vendors independent of the acquisition and reconstruction methods used and it requires fewer manual interactions during the scan which shortens the procedure time. Moreover, it does not require a certain radiation exposure of the preceding scans for sufficient noise measurements, lowering the cumulative radiation exposure.
MPL was chosen as the correcting parameter in this study based on its stronger correlation with normalized image noise in comparison to BMI (R2 = 0.68 and 0.63, respectively). The choice of MPL may be interpreted as arbitrary. However, when seeing the body morphology as a cylinder, the mass per length provides an estimate of the cross-sectional area of a patient and therefore thickness, intuitively making more sense than dividing the mass by a squared length, like at BMI. In the study by Li et al. [18] they tried to identify the parameter best explaining the image noise in CCTA. They determined that chest circumference at the right coronary artery origin level (R2 = 0.60) was the parameter best correcting for the varying patient size. However, they did not test whether this parameter differed significant from BMI (R2 = 0.53). Moreover, they did not include any other parameters that can be considered as easily adoptable in clinical practice, such as weight or MPL.
In our study we made several assumptions. First, a more constant image noise level was assumed to result in a better image quality in CCTA. Yet image quality in CCTA also depends on the heart rate, breath holding, iodine enhancement and contrast timing [6, 19, 20]. A qualitative image quality assessment, purely assessing the effect of the obtained constant image noise while excluding the influences of these other parameters, was considered as hardly possible. However, obtaining a less variable quantitative image noise can be seen as an independent and essential first step towards a constant image quality. Second, the image noise was determined in the liver instead of in the thoracic region, as the non-uniform contrast enhancement makes the definition of homogeneous regions of interest difficult [7]. However, the cranial liver parenchyma is typically located on the same axial level of the caudal part of the myocardium and was therefore considered representative for cardiac image noise measurements. Third, the protocol was only derived for patients within a certain body size range (35 kg/m < MPL < 60 kg/m) which might not fully represent the clinical practice. Final, no iterative reconstruction was used. Yet application of iterative reconstruction instead of filtered back projection results in an evenly spread proportional decrease of the image noise which does not compensate for the higher image noise in heavier patients [21]. The method as presented in this study can be used in combination with iterative reconstructions. Moreover, application of iterative reconstructions will allow the use of a lower desired constant image noise (σC) which enables the use of a lower CTDI without compromising image quality [22].
In conclusion, we have derived a MPL dependent CCTA prospective ECG-triggering dose protocol using the proposed method which is also eligible for CT scanners from other vendors. Application of this protocol resulted in an image noise independent of patient’s size. It provided a less variable image quality and better radiation dose justification.
Abbreviations
- CCTA:
-
Coronary computed tomography angiography
- CTDI:
-
Computed tomography dose index
- MPL:
-
Mass per length (kg/m)
References
Montalescot G, Sechtem U, Achenbach S et al (2013) 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J 34:2949–3003
Einstein AJ, Moser KW, Thompson RC et al (2007) Radiation dose to patients from cardiac diagnostic imaging. Circulation 116:1290–1305
Abbara S, Arbab-Zadeh A, Callister TQ et al (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 3:190–204
Halliburton SS, Abbara S, Chen MY et al (2011) SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT. J Cardiovasc Comput Tomogr 5:198–224
Flotats A, Knuuti J, Gutberlet M et al (2011) Hybrid cardiac imaging: SPECT/CT and PET/CT. A joint position statement by the European Association of Nuclear Medicine (EANM), the European Society of Cardiac Radiology (ESCR) and the European Council of Nuclear Cardiology (ECNC). Eur J Nucl Med Mol Imaging 38:201–212
Mark DB, Berman DS, Budoff MJ et al (2010) ACCF/ACR/AHA/NASCI/SAIP/SCAI/SCCT 2010 expert consensus document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on expert consensus documents. Circulation 121:2509–2543
Hur G, Seong WH, Su YK et al (2007) Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography. Am J Roentgenol 189:188–196
Qi W, Li J, Du X (2009) Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT. Korean J Radiol 10:568–574
Ghafourian K, Younes D, Simprini LA et al (2012) Scout view X-ray attenuation versus weight-based selection of reduced peak tube voltage in cardiac CT angiography. JACC Cardiovasc Imaging 5:589–595
Hosch W, Stiller W, Mueller D et al (2012) Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative reconstruction. Eur J Radiol 81:3568–3576
Odedra D, Blobel J, AlHumayyd S et al (2014) Image noise-based dose adaptation in dynamic volume CT of the heart: dose and image quality optimisation in comparison with BMI-based dose adaptation. Eur Radiol 24:86–94
Rogalla P, Blobel J, Kandel S et al (2010) Radiation dose optimisation in dynamic volume CT of the heart: tube current adaptation based on anterior–posterior chest diameter. Int J Cardiovasc Imaging 26:933–940
Tatsugami F, Husmann L, Herzog BA et al (2009) Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggering. Am J Roentgenol 192:635–638
Shen J, Du X, Guo D et al (2013) Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography. Eur J Radiol 82:349–355
Menke J (2005) Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236:565–571
Menzel HG, Schibilla H, Teunen D E (2000) European guidelines on quality criteria for computed tomography. Publication No. EUR 16262 EN
Ou X, Jiang L, Huang R et al (2013) Computed tomography attenuation correction improves the risk stratification accuracy of myocardial perfusion imaging. Nucl Med Commun 34:495–500
Li J-L, Liu H, Huang M-P et al (2014) Potentially optimal body size to adjust tube current for individualized radiation dose control in retrospective ECG-triggered 256-slice CT coronary angiography. Hell J Cardiol 55:393–401
McCollough CH, Primak AN, Braun N et al (2009) Strategies for reducing radiation dose in CT. Radiol Clin North Am 47:27–40
Leipsic J, Labounty TM, Heilbron B et al (2010) Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. Am J Roentgenol 195:655–660
Zhao L, Plank F, Kummann M et al (2015) Improved non-calcified plaque delineation on coronary CT angiography by sonogram-affirmed iterative reconstruction with different filter strength and relationship with. BMI 5:104–112
Leipsic JA, Labounty TM, Heilbron B et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. Am J Roentgenol 195:649–654
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
All authors declare that they have no conflicts of interest.
Ethical standard
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Informed consent
Informed consent was obtained from all individual participants included in the study.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
van Dijk, J.D., Huizing, E.D., Jager, P.L. et al. A practical approach for a patient-tailored dose protocol in coronary CT angiography using prospective ECG triggering. Int J Cardiovasc Imaging 32, 531–538 (2016). https://doi.org/10.1007/s10554-015-0802-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-015-0802-z