Abstract
Increased awareness of climate change has precipitated more stringent mitigation targets. Public sector institutions in Canada are committed to becoming carbon neutral to attain a leadership position in climate change mitigation-related initiatives. Recent statistics reveal that buildings account for the majority of the corporate carbon footprint of public sector institutions. Hence, there is an increasing interest towards developing net zero energy and net zero emission buildings to comply with climate action targets. With limited financial resources, public sector institutions must optimize investments into building energy retrofits by considering lifecycle cost (LCC), overall energy performance, and related greenhouse gas (GHG) emission. The aim of this paper is to develop an investment planning approach for net zero emission buildings (NZEB). First, an investment planning approach for NZEB is proposed. A typical recreational centre building in British Columbia, Canada, was used as the archetype to demonstrate the concept. Second, innovative and proven building energy retrofits were analysed using energy simulation software to assess the impact on energy consumption reduction, GHG emissions, and LCC. Third, impacts of geographical location, tariff regimes, and grid emission factors on energy retrofits were studied by locating the same building in other provinces of Canada. This study revealed that net zero energy investment has a strong correlation to the grid emission factor. The proposed approach in this paper will assist building managers and owners in retrofitting and budget planning.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
One of the primary outcomes of the United Nations Paris Agreement in 2016 was a commitment to limit global temperature increase to 1.5 degrees Celsius above the pre-industrial levels (United Nations Framework Convention on Climate Change 2016). This target requires strengthening mitigation plans more than ever before. Reducing GHG emissions and the environmental footprint have been priorities of the Federal Sustainable Development Strategy (FSDS) of Canada from 2013 to 2016 (Environment Canada 2013). Canada is committed to the Copenhagen Accord and has targeted an ambitious 17% GHG emission reduction by 2020 (612 Mt CO2 eqFootnote 1) from the 2005 GHG emission level (738 Mt CO2 eq) (Canada’s Action on Climate Change 2013). In 2012, GHG emissions in Canada reached 699 Mt CO2 eq, which is a 5.2% decrease from 2005 levels. GHG emissions in British Columbia (BC) should be reduced 33% by 2020 and 80% by 2050 from 2007 levels (Ministry of Environment BC 2007). In 2012, BC reduced its GHG emissions by 4.4% from 2007 levels (Ministry of Environment BC 2012). Therefore, Canada has to pursue more aggressive strategies to achieve the Copenhagen Accord target by 2020 (Environment Canada). In order to support the ongoing climate action agenda, a majority of public sector organizations of BC signed the BC climate action charter and committed to becoming carbon neutral by 2012 (Government of British Columbia 2013). In the quest to become carbon neutral, municipal governments are compelled to implement programs and policies that contribute to a reduced carbon footprint of both corporate and community actions. Improving the energy efficiency of buildings is one of the most viable ways to achieve institutional climate action targets, since buildings emit approximately one third of the GHG emissions in Canada (Frappé-Sénéclauze and Kniewasser 2015).
Building industry initiatives to mitigate climate impact include net zero energy buildings, net zero emission buildings, net zero source energy buildings, and net zero cost buildings (Torcellini et al. 2006). These building types adopt energy efficiency features to reduce energy demand and supply the remaining demand via renewable energy sources (Steven Winter Associates Inc. 2014). Net zero emission buildings (NZEB) use emission-free energy and supply the energy demand through on-site renewable energy generation (US Department of Energy 2015). Advantages of NZEBs include minimized environmental footprint, minimized operation and maintenance costs, system reliability, and energy security (US Department of Energy 2015). The NZEB was identified as a key route to ambitious energy efficiency targets in BC (Frappé-Sénéclauze and Kniewasser 2015).
Energy retrofitting is the most preferred building GHG emission mitigation strategy (Estes 2011). Building energy retrofits aim to reduce GHG emissions, improve energy performance, and reduce fuel consumption while maintaining comfort levels (Picco et al. 2014) (Yu and Chow 2007). Common barriers for building retrofit projects include lack of funding, lack of interoperability, and unstructured decision-making (Woo and Menassa 2014). Despite a large number of policy instruments aimed at improving building energy efficiency, the pace of innovation is deemed inadequate (Altwies and Nemet 2013). Altwies and Nemet determined that this is the result of insufficient information, disjointed decision-making, principal agent problems, and lack of learning from similar projects (Altwies and Nemet 2013).
The feasibility of an energy retrofit depends on a number of factors, such as building characteristics and location (Liu et al. 2010; Kircher et al. 2010; Huang et al. 2013). The whole building energy system should be analysed to determine feasible energy retrofits (Zhao et al. 2009). This method should be capable of detecting abnormalities in building energy efficiency and to improve performance of the building (Escrivá-Escrivá et al. 2012). Budget limitations require innovative decision-making methods to obtain the best value for allocated funds. In building retrofitting, it is important to identify the retrofit that achieves the best reduction in energy consumption, GHG emissions, and operational cost (Wang et al. 2014).
Despite the availability of a large number of energy retrofits, analysing and identifying the most suitable retrofit remains a challenge (Asadi et al. 2014). Decision-making associated with energy efficiency investments is not straightforward (Hertzsch et al. 2012). Various appraisal methods have been used for evaluating building energy retrofits (Martinaitis et al. 2007). Though energy simulation software can estimate the impacts of an energy retrofit, the use of simulation software is limited to trained professionals (Chidiac et al. 2011). Building energy consumption, GHG emissions, and lifecycle costs (LCC) have complex interactions when identifying the optimal investment limit for retrofits. Energy, environment, economy, and timing of retrofits are the main decision criteria in building management. Since various retrofits are available for GHG emission, operational cost reduction is important when determining the optimal trade-off (Chiang et al. 2014). Reliable analysis of interactions between building condition, environment, and annual energy consumption is cumbersome (Peng et al. 2014). Optimization of building energy retrofits considering multiple factors has been overlooked by the building industry (Rysanek and Choudhary 2013). Hence, the retrofit planning process should be improved to obtain the best value for investment.
This paper presents a detailed investigation of energy retrofit planning based on regional characteristics and extends the concept to NZEB. First, a comprehensive investment planning method was proposed for NZEB. Second, the proposed approach was applied for an aquatic centre building operating in British Columbia, Canada. Innovative and proven building retrofits were identified and optimized to identify the best retrofit alternative considering energy consumption, GHG emission, and investment. Third, the impacts of varying climates and tariff schemes on the optimal retrofit were analysed for various provinces in Canada to determine the optimal net zero emission investments (NZEI). This study informs building managers in determining the investment required to achieve superior GHG emission reduction targets by incorporating regional climate and tariffs.
Literature review
Decision-making based on capital cost can be a significant drawback in infrastructure management, as it ignores the operating costs of assets, which can be substantial across the life of the constructed facility (iceberg effect) (Wübbenhorst 1986; Bull 1993). Hence, lifecycle cost has become popular recently as a basis for making engineering-related decisions. More recent literature reveals that an integrated decision-making approach has been adopted in infrastructure-related decision-making. There are many innovative triple bottom line-based decision-making methods that assist infrastructure planning and management by incorporating social, environmental, and economic priorities into the evaluation. Innovative triple bottom line-based infrastructure management decision-making methods include water–energy nexus (Assaf et al. 2002; Hossaini et al. 2014); water–energy–GHG nexus (Nair et al. 2014); and eco-efficiency analysis (Seiler-Hausmann 2004) (United States Environmental Protection Agency (USEPA) 2014).
Identifying the optimal retrofit level for buildings has been a popular research topic in recent years (Leal et al. 2014; Ferrara et al. 2014). Ibn-Mohammed et al. (2014) have developed an approach to evaluating and identifying economically efficient building retrofit options that achieve the highest operational and embodied GHG reductions. Ashrafian et al. (2016) proposed a framework that helps identify energy retrofits from cost and energy savings. Chidiac et al. (2011) proposed a regression approach to estimating the impact of building energy retrofits. Leal et al. (2014) identified that medium efficiency is the best retrofit level from an economic perspective. McArthur and Jofeh (2015) suggested an approach that identifies strategic investments for building retrofits in a building portfolio. Jafari and Valentin (2015) developed an approach that identified the optimal retrofit level for a residential building based on energy consumption savings. Findings of this study were based on a single case study and required additional case studies to improve the validity of the findings.
Simulation-based optimization methods have been developed to identify a cost-optimal energy efficiency retrofit configuration (Ferrara et al. 2014). Asadi et al. (2012) used a TRNSYS, Genopt, and MATLAB-based multi-objective optimization model to select retrofit strategies. Asadi et al. (2014) proposed a genetic algorithm and artificial neural network-based model for assessing energy retrofits. A similar approach was used by Magnier and Haghighat (2010) to optimize the design of a building. Wang et al. (2014) proposed an optimization model for building retrofitting that maximizes energy savings and operational cost savings. Ferrara et al. (2014) tried a cost-optimal configuration of near net zero energy buildings. Malatji et al. (2013) proposed a multi-objective optimization model for building retrofits by optimizing energy savings and payback period. Shao et al. (2014) used a multi-objective optimization (MOO) model and stakeholder requirement analysis-based framework for decision-making for selecting building energy retrofits. Zhivov et al. (2013) proposed an energy optimization method for operating army buildings.
Net zero emission buildings (NZEB)
Similar to net zero energy buildings, NZEB is a new concept. Improving energy efficiency is the priority in achieving net zero energy/emission status. The remaining energy demand should be met by renewable energy sources that are economical, readily available, and replicable (Steven Winter Associates Inc. 2014). For NZEB, supply may be from on-site or off-site renewable energy sources (Torcellini et al. 2006). A building that is situated in an area with a clean electricity grid (e.g. hydro, nuclear) can achieve net zero emission status with lesser configurations than a similar building powered with electricity generated by a coal powered plant (Torcellini et al. 2006). Hence, the regional grid emission factor is important in NZEB (Torcellini et al. 2006). Because grid energy sources vary extensively across Canada, energy prices and carbon footprints of the grid vary extensively between regions. “Appendix” lists rates and GHG emission conversion factors for electricity and natural gas for Canadian Provinces.
Building retrofits are vital for achieving NZEB and they encompass efficiency improvements and renewable energy generation. Building energy retrofits are classified into three categories: minor, major, and deep retrofits, as discussed below (Natural Resources Canada 2014).
Minor retrofits Minor retrofits are low-cost, easy to implement modifications to a building that offer good value for the money and effort (low hanging fruit), e.g. air sealing of the building, upgrading lighting systems. These modifications can create considerable differences in the building’s energy consumption (Natural Resources Canada 2014).
Major retrofits Major building retrofits are holistic modifications to buildings that can be installed with minimal disturbance to the building users. Several examples of major retrofits include replacing building fenestration items, upgrading the HVAC system, and installing automated controls (Natural Resources Canada 2014).
Deep retrofits Deep retrofits are expensive overhauls of the building envelope and HVAC system. Examples include roof replacements, installing ground source heat pumps, and rearranging window locations. Even though these options are highly disruptive to building occupants, they have the potential to result in high energy savings (~60%). It is beneficial to combine deep retrofits with large-scale renovation projects (Natural Resources Canada 2014).
This study evaluates the impacts of energy retrofits on an aquatic centre building. Specific features of public aquatic centre buildings are explained below.
Public aquatic centre buildings
Published literature has largely overlooked performance assessments of public aquatic centre buildings. Only a handful of studies related to this subject area were found during the literature search. Howat and Crilley (2007) developed a performance assessment model for aquatic centres integrating customer service quality, satisfaction, and operational performance. Another study by Howat et al. (2008) examined the relationships among service quality, overall satisfaction, and customer loyalty for Australian aquatic buildings. This study revealed that the main factors influencing overall satisfaction are relaxation, staffing, and facility presentation. Priyadarsini (2014) studied energy performance of aquatic centre buildings in Victoria and revealed that annual energy use intensity in aquatic centres ranges from 632 to 2247 kWh/m2. Sharma et al. (2008) mentioned that customer expectations, legislative requirements, and the community are important criteria for assessing the level of service for an infrastructure asset. Multipurpose public aquatic facilities can be financially viable sources of earning and can attract greater public participation. Public aquatic centre buildings consist of multiple areas such as swimming pools, gymnasiums, sports halls, cafeterias, administrative blocks (Trianti-Stourna et al. 1998); the floor area of an aquatic centre building ranges from 4883 to 7825 m2 to accommodate these various functions.
Energy consumption within public aquatic centre buildings is quite different than regular commercial and institutional buildings. Figure 1 shows annual energy consumption within a typical public aquatic centre building (Trianti-Stourna et al. 1998).
Methodology
A sequential process was adopted to identify optimal investment and planning for building energy retrofits (Fig. 2). This generic framework could be adopted for different building types.
Case study
A sample aquatic centre building operating in South Okanagan, BC Canada, was used for demonstration purposes. As-built drawings were used to develop a 3D model of the building. The identified system was modelled using Design Builder V4 software environment. Building details collected from as-built drawings and expert input are presented in Table 1.
Figure 3 depicts the schematic view of the Design Builder model used in this study. The model was validated using annual energy consumption data (Shown in Fig. 4). Annual monitored energy values were compared with estimated values from the energy model.
Energy retrofits for aquatic centre buildings
Published literature was used to identify energy retrofits for aquatic centre buildings (Table 2). These retrofits have been successfully used in various aquatic centre buildings in Canada. Identified energy retrofits were simulated in the Design Builder energy building simulation software. Simulation results are presented in “Appendix”.
Ranking energy retrofits
The objective of energy retrofits is to decrease annual cost savings, decrease energy consumption, and decrease GHG emissions. Hence, retrofit alternatives were ranked according to the 3Es (energy, economy, and environment). Energy simulation and LCC analysis results for each retrofit were normalized to obtain a score for each parameter. Scores for the 3Es were combined using the weighted sum method to obtain a final score. Equal weighting was considered for the 3Es. The final score was used to rank the energy retrofits considered.
Investment planning for NZEB
Results of energy simulations for retrofit alternatives were used to determine energy cost reduction, GHG emission reduction, and LCC for various retrofit investments. Maintenance cost was assumed to be included in the installation cost contract. Equations (1–4) were used to calculate the aforementioned values.
Equivalent annualized cost (EAC) of the initial investment is calculated using Eq. (4) (Sasmita 2010).
Where i is the discounting factor and n is the number of periods.
Regional analysis for Canada
The same building was simulated at different geographical locations in Canada. Details about the locations of the building, electricity grid, and tariff information are presented in “Appendix”. In order to identify the optimal retrofit investment curves for energy cost reduction, energy consumption and LCC should be identified. This step required a large number of data points to construct a graph. Hence, various combinations of retrofits identified in Table 1 were considered. Microsoft Excel was used to create the required data points for the analysis. Equations (1–3) were used to calculate all possible data points. For 10 retrofits, 1024 combinations were created. A second-order polynomial function was used for similar applications in the literature (Jafari and Valentin 2015), and it had the best fit for data points. Hence, the second-order polynomial function was assumed for the trend line. Optimal investment for retrofits, retrofit investment for new zero GHG, and energy status were calculated for various regions of Canada assuming the same building. Microsoft Excel solver was used to solve the polynomial function obtained for LCC, GHG emission, and energy cost reduction.
Results
Energy simulation for the considered building returned the following results. Figure 4 compares simulation results with monitored values and shows that the energy model is a reasonable representation of the building in focus.
Table 3 presents values calculated for energy cost reduction, lifecycle cost, and GHG emissions for the Okanagan region of BC. Detailed cost and energy information are included in “Appendix”. Retrofits are ranked based on energy reduction, GHG emission, and lifecycle cost, assuming equal weight for the three parameters. Based on the analysis, automatic lighting controls (R6) are the optimal retrofit.
Based on Fig. 5, net zero emission investment (NZEI) is CAD 824,640 for the building in focus. These retrofits will achieve an annual operational cost reduction of CAD 57,737.
Therefore, in order to become NZEB, the optimal approach is installing retrofits R1, R2, R3, R5, R6, R7, R8, R9, and R10 (Cost CAD 856,796).
Regional analysis
The impact of optimal retrofit alternatives on regional characteristics is presented in Table 4. Table 4 depicts that optimal retrofits differ based on the provincial grid and energy tariff.
Table 5 lists net zero energy installation (NZEI) for different provinces of Canada. Per floor area, NZEI was calculated to generalize the findings. This data would assist in capital budget planning for building energy retrofits. The analysis was not conducted for Prince Edward Island, Newfoundland and Labrador, the Yukon, and the Northwest Territories due to unavailability of data. Results show that geographical variation is a main factor affecting optimal retrofit.
Figure 6 presents NZEI as a function of the provincial grid emission factor. There is a strong correlation (R 2 = 0.9715) between the grid emission factor and NZEI.
Discussion
Renovation and refurbishment of buildings is a more prudent approach than new building construction. Building renovation and refurbishment provides improved functional quality, durability, and economy compared to demolition and reconstruction (Poel et al. 2007). Also, the use of proper refurbishment methods contribute to environmentally sound buildings with social and financial value throughout the life cycle of a building (Poel et al. 2007). A planned and systematic investment planning approach was proposed for achieving NZEB. An energy simulation analysis was conducted to identify the optimal energy retrofit investment and investment to achieve net zero emission status. This study was extended to various provinces in Canada to identify the impact of regional grid and energy (i.e. electricity and natural gas) tariffs on retrofit investment planning.
Based on the analysis, economic and environmental viability of the retrofit would change as a result of locational parameters (e.g. energy tariff, grid emission factor). Hence, proven technology in one province would not be feasible in a different province. Detailed analysis is needed before retrofitting the built environment. This study further investigated the correlation between the grid emission factor and NZEI. The strong correlation reveals that larger investments are needed to achieve net zero emission in provinces such as Alberta and Nova Scotia. Per floor area, investment cost identified in this study can be used directly in energy investment planning for aquatic centre buildings with similar configurations.
The analysis for the operating building in BC revealed that the NZEI is CAD 856,796 and annual operational cost reduction is CAD 57737. Based on the analysis, the simple payback period is 14.8 (~15) years. This is a significant time span and can be associated with significant uncertainty due to macroeconomic factors. Hence, it is important to incorporate various uncertainties in retrofit LCC calculation using a suitable method (Ruparathna et al. 2017). In 2016, a tonne of GHG was valued at CAD 41 and is expected to increase in the future (Environment and Climate Change Canada 2016). If the monetary value of all NZEB benefits is considered, the payback period would be further shortened.
Several studies in the past have revealed that, except at the end of the life stage, retrofitted buildings outpace new buildings in assembly and operation phases (McGrath et al. 2013). Building retrofits are commonly analysed based on their impact on energy and lifecycle cost, overlooking lifecycle impacts (Jafari and Valentin 2015). Various factors can affect the decision-making related to refurbishments, such as economy, impact on the ecological environment, and heritage value (Kovacic et al. 2015). The lifecycle impact differs depending on the geographic location. Hence, incorporating lifecycle impacts of retrofits can contribute to a holistic analysis of a retrofit. These decisions should be supported by adequate information, incentives, knowledge, and access to capital (Hinnells 2008). Currently, the construction industry lacks such decision support frameworks.
The purpose of this study was to identify the trend line of GHG emissions, lifecycle cost, and energy cost. One thousand and twenty-three combination scenarios were analysed using ten different retrofits to determine the trend lines. The analysed list of retrofits were commonly used in aquatic centres. There are other popular retrofits, such as heat recovery, which could have been considered in the analysis. Incorporating additional retrofits will further improve the accuracy of the trend lines. In the context of the building considered, net zero emission does not achieve net zero energy or net zero cost status; the primary reason is the zero emission hydroelectricity used in the building. Even though the emission factor of the BC electricity grid is 9.1 g CO2(eq)/kWh, energy utility companies supply electricity with low emission factors. Therefore, net zero cost status is not achieved during the zero emission stage. Energy operational cost reduction at NZEI in provinces with a high grid emission factor (e.g. Alberta) would be greater than in provinces with low grid emission factor (e.g. BC). Similar to the above, low emission electricity can be purchased from utility companies at different tariffs, lowering the net zero emission retrofit investment.
Buildings classified as net zero energy or net zero emissions can be connected to the grid (Steven Winter Associates Inc 2014). This energy would be utilized at times when renewable energy cannot meet the building’s energy demand. Where the law permits, the surplus on-site generation can be supplied to the grid. Due to high costs associated with energy storage, grid connection ensures reliability of the building energy system. Energy exported from the building to the grid can positively impact the project economics.
The proposed approach can be applied in budgeting for energy retrofits for buildings. Presently, retrofits are planned on an ad-hoc basis. The proposed systematic procedure will ensure value for money in case of limited financial resources. This study highlighted the regional variability of energy retrofit impacts due to climatic, tariff, and grid differences. This highlights the importance of focusing on detailed analysis of a retrofit project incorporating priorities of institutions. The proposed method allows the organization to set weights for the 3Es (i.e. energy, economy, and environment) to identify the best retrofit alternative, which may not be the most economically sound alternative. Additionally, as public buildings are operated using public money it is important to maintain transparency in management decisions. Public institutions are compelled to reduce GHG emission from buildings with the recent carbon neutral corporate climate action plans. Hence, this study provides a structured approach that enables them to proceed to this goal without affecting the transparency of the process.
Implementing NZEI is a challenge due to budget restrictions in public entities. These retrofits should be implemented as annual packages to match the annual budget allocation. Hence, a systematic sequential procedure should be adopted to achieve the eventual zero emission status. Despite huge interest in NZEB within the industry, limited frameworks are available to guide users in achieving zero emission status.
Limitations of this study
Several limitations were observed in this study, and adjustments were made to mitigate their impact. Further research on these limitations would strengthen the movement towards NZEB.
-
Findings from this study (NZEI for buildings) could be generalized only after extensive studies. The above results could be used for buildings with similar configurations, even though NZEI could differ with building use, size, etc.
-
LCC cost parameters are associated with significant uncertainties. Electricity and natural gas rates in major cities across Canadian Provinces were identified from the literature. These rates may change by utility provider and are subject to inflation over time. There may also be rate arrangements between building owners and utility providers. This drawback was minimized by adopting novel energy retrofit lifecycle costing methods.
-
This analysis ignored deterioration of equipment and building components, and replacing retrofits at the end of their economic life. Deterioration of equipment will reduce the components’ performance, eventually affecting the results. However, future technologies will be more energy efficient and more economical than those currently in use. This would be a main uncertainty associated with this analysis.
-
The GHG emission factor of natural gas was assumed to be equal for all provinces due to data limitations. This value can vary from province to province due to differences in extraction, processing, and transportation. Currently, landfill gas is used as renewable natural gas with a low GHG emission factor. Since the supply of renewable natural gas is limited, it was omitted from this analysis.
-
This study assumed polynomial functions to GHG emission, energy cost reduction, and lifecycle cost. This assumption is another uncertainty associated with the results. However, the results display minor deviations when different trend lines were assumed.
-
This study ignored the time dependency of grid source energy. Time-dependent valuations for time of use source energy is an important factor in determining the net zero emission. Hence, real-time building management is needed to maintain the net zero emission status.
-
The purpose of this study was to identify the trend line of the GHG emission, lifecycle cost and energy cost. One thousand and twenty-three combinations scenarios were analysed using ten different retrofits to determine the trend lines. The analysed list of retrofits was commonly used in aquatic centres. There are other popular retrofits such as heat recovery which could have considered in the analysis. Incorporating additional retrofits will further improve the accuracy of the trend lines.
-
The proposed approach ignores interactions between energy retrofits. For example, LED lighting has a lower heat output than fluorescent lighting, which can have an impact on the heating energy demand. Interactions can be accounted for when simulating each retrofit scenario. However, simulating a large number of energy scenarios will be time consuming.
Conclusions
Increased awareness of climate change mitigation has stimulated an interest in building energy retrofitting. The optimal retrofit for buildings depends on factors such as climate, tariffs, local grid, initial investment, and institutional goals. Detailed analysis of the retrofit is essential in the prefeasibility stage. In order to ensure transparency and effectiveness, retrofit planning should be standardized. Due to the service life of the building, it is important to incorporate the associated uncertainties. The results of this research revealed that NZEI is strongly correlated to the grid emission factor. Hence, the proposed approach would contribute to existing practices by achieving maximum emission reductions as well as being financially viable.
The findings of this study could be extended to several other areas. First, the proposed methodology could be developed for different types of commercial and institutional buildings. A similar study would help to establish a stronger correlation between NZEI and grid emission factor. The aforementioned findings could be used to develop a generalized tool that would be used in energy retrofit planning. Second, it is important to study the uncertainty associated with the parameters. Third, enabling the ability to integrate user preference into the retrofit planning will enhance the flexibility of the proposed concept. This flexibility can be achieved by defining a weight scheme for the parameters. The aforementioned improvements would lead to a user-friendly and industry-ready decision-making tool for building retrofit planning. Finally, further research is needed on implementing the findings from this research. Characteristics of retrofits vary from one to another (e.g. service life). Hence, a systematic capital expenditure planning approach should be developed to plan retrofit installation to gain the best value for the building owners.
Notes
Mega tonnes of carbon dioxide equivalent.
References
Altwies JE, Nemet GF (2013) Innovation in the U.S. building sector: an assessment of patent citations in building energy control technology. Energy Policy 52:819–831. doi:10.1016/j.enpol.2012.10.050
Asadi E, da Silva MG, Antunes CH, Dias L (2012) A multi-objective optimization model for building retrofit strategies using TRNSYS simulations, GenOpt and MATLAB. Build Environ 56:370–378. doi:10.1016/j.buildenv.2012.04.005
Asadi E, Da Silva MG, Antunes CH et al (2014) Multi-objective optimization for building retrofit: a model using genetic algorithm and artificial neural network and an application. Energy Build 81:444–456. doi:10.1016/j.enbuild.2014.06.009
Ashrafian T, Yilmaz AZ, Corgnati SP, Moazzen N (2016) Methodology to define cost-optimal level of architectural measures for energy efficient retrofits of existing detached residential buildings in Turkey. Energy Build 120:58–77. doi:10.1016/j.enbuild.2016.03.074
Assaf SA, Al-Hammad A, Jannadi OA, Saad SA (2002) Assessment of the problems of application of life cycle costing in construction projects. Cost Eng 44:17–22
Bull JW (1993) Life cycle costing for construction. Spon press, London
Canada′s action on climate change (2013) Copenhagen Accord. http://climatechange.gc.ca/default.asp?lang=En&n=AA3F6868-1
CEI Architecture Planning Interiors (2011) UBC new aquatic centre study. Vancouver, BC
Chiang Y, Zhou L, Li J (2014) Achieving sustainable building maintenance through optimizing life-cycle carbon, cost, and labor: case in Hong Kong. J Constr 140:1–10. doi:10.1061/(ASCE)CO.1943-7862.0000823
Chidiac SE, Catania EJC, Morofsky E, Foo S (2011) A screening methodology for implementing cost effective energy retrofit measures in Canadian office buildings. Energy Build 43:614–620. doi:10.1016/j.enbuild.2010.11.002
City of Toronto (2009) Community centre and pools: energy retrofit case study. https://www1.toronto.ca/City of Toronto/Environment and Energy/Key Priorities/Files/pdf/R/Retrofit/community_centre_case_study.pdf. Accessed 8 Jun 2016
City of Toronto (2014) Energy conservation and demand management (ECDM) plan. Toronto, ON
Enridge Gas New Brunswick (2016) Handbook of rates and distribution services. Fredericton
Environment Canada (2013) Planning for a sustainable future: a federal sustainable development strategy for Canada 2013–2016. https://www.ec.gc.ca/dd-sd/default.asp?lang=en&n=B8F4119E−1#fnb6
Environment Canada (2014) National inventory report 1990–2012. Ottawa
Environment and Climate Change Canada (2016) Technical update to environment and climate change Canada’s social cost of greenhouse gas estimates. Environment and Climate Change Canada, Gatineau
Escrivá-Escrivá G, Santamaria-Orts O, Mugarra-Llopis F (2012) Continuous assessment of energy efficiency in commercial buildings using energy rating factors. Energy Build 49:78–84. doi:10.1016/j.enbuild.2012.01.020
Estes HM (2011) Economic analysis of energy retrofit. University of Alabama
Ferrara M, Fabrizio E, Virgone J, Filippi M (2014) A simulation-based optimization method for cost-optimal analysis of nearly zero energy buildings. Energy Build 84:442–457. doi:10.1016/j.enbuild.2014.08.031
FortisBC (2016) Rate schedule. https://www.fortisbc.com/About/RegulatoryAffairs/GasUtility/NatGasTariffs/Documents/RateSchedule_1.pdf
Frappé-Sénéclauze T-P, Kniewasser M (2015) The path to “Net-zero energy” buildings in BC. Victoria
ATCO Gas (2016) Current rate summary. http://www.atcogas.com/Rates/Current_Rates/Current-Rates-South-Customer-Rate-Summary. Accessed 14 Jul 2016
Gaz Métro (2016) Price of natural gas. http://www.gazmetro.com/en/business/price/natural-gas-price/. Accessed 14 Jul 2016
Government of British Columbia (2013) Carbon neutral government overview. Victoria
Heritage Gas (2016) Rates for business. http://www.heritagegas.com/business/rates-business/. Accessed 14 Jul 2016
Hertzsch E, Heywood C, Piechowski M (2012) A methodology for evaluating energy efficient office refurbishments as life cycle investments. Int J Energy Sect Manag 6:189–212. doi:10.1108/17506221211242068
Hinnells M (2008) Technologies to achieve demand reduction and microgeneration in buildings. Energy Policy 36:4427–4433. doi:10.1016/j.enpol.2008.09.029
Hossaini N, Reza B, Akhtar S et al (2014) AHP based life cycle sustainability assessment (LCSA) framework: a case study of six storey wood frame and concrete frame buildings in Vancouver. J Environ Plan Manag. doi:10.1080/09640568.2014.920704
Howat G, Crilley G (2007) Customer service quality, satisfaction, and operational performance: a proposed model for Australian public aquatic centres. Ann Leis Res 10:168–195. doi:10.1080/11745398.2007.9686760
Howat G, Crilley G, Mcgrath R (2008) A focused service quality, benefits, overall satisfaction and loyalty model for public aquatic centres. Manag Leis 13:139–161. doi:10.1080/13606710802200829
Huang Y, Niu J, Chung T (2013) Study on performance of energy-efficient retrofitting measures on commercial building external walls in cooling-dominant cities. Appl Energy 103:97–108. doi:10.1016/j.apenergy.2012.09.003
Ibn-Mohammed T, Greenough R, Taylor S et al (2014) Integrating economic considerations with operational and embodied emissions into a decision support system for the optimal ranking of building retrofit options. Build Environ 72:82–101. doi:10.1016/j.buildenv.2013.10.018
International Energy Agency (2011) Technology roadmap. https://www.iea.org/roadmaps/
Jafari A, Valentin V (2015) Decision-making life-cycle cost analysis model for energy-efficient housing retrofits. Int J Sustain Build Technol Urban Dev 6:173–187. doi:10.1080/2093761X.2015.1074948
Kircher K, Shi X, Patil S, Zhang KM (2010) Cleanroom energy efficiency strategies: modeling and simulation. Energy Build 42:282–289. doi:10.1016/j.enbuild.2009.09.004
Kovacic I, Summer M, Achammer C (2015) Strategies of building stock renovation for ageing society. J Clean Prod 88:349–357. doi:10.1016/j.jclepro.2014.04.080
Leal VMS, Granadeiro V, Azevedo I, Boemi S-N (2014) Energy and economic analysis of building retrofit and energy offset scenarios for net zero energy buildings. Adv Build Energy Res 9:120–139. doi:10.1080/17512549.2014.944567
Liu J, Li W, Liu J, Wang B (2010) Efficiency of energy recovery ventilator with various weathers and its energy saving performance in a residential apartment. Energy Build 42:43–49. doi:10.1016/j.enbuild.2009.07.009
Magnier L, Haghighat F (2010) Multiobjective optimization of building design using TRNSYS simulations, genetic algorithm, and artificial neural network. Build Environ 45:739–746. doi:10.1016/j.buildenv.2009.08.016
Malatji EM, Zhang J, Xia X (2013) A multiple objective optimisation model for building energy efficiency investment decision. Energy Build 61:81–87. doi:10.1016/j.enbuild.2013.01.042
Manitoba Hydro (2015) Utility rate comparisons. https://www.hydro.mb.ca/regulatory_affairs/energy_rates/electricity/utility_rate_comp.shtml. Accessed 18 Jun 2016
Manitoba Hydro (2016) Current natural gas rates. https://www.hydro.mb.ca/regulatory_affairs/energy_rates/natural_gas/current_rates.shtml. Accessed 14 Jul 2016
Martinaitis V, Kazakevičius E, Vitkauskas A (2007) A two-factor method for appraising building renovation and energy efficiency improvement projects. Energy Policy 35:192–201. doi:10.1016/j.enpol.2005.11.003
McArthur JJ, Jofeh CGH (2015) Strategic retrofit investment from the portfolio to the building scale: a framework for identification and evaluation of potential retrofits. Procedia Eng 118:1068–1076. doi:10.1016/j.proeng.2015.08.550
McGrath T, Basheer M, Keig P et al (2013) Retrofit versus new-build house using life-cycle assessment. Proc ICE Eng Sustain 166:122–137. doi:10.1680/ensu.11.00026
Ministry of Environment BC (2007) Ministry of environment climate action secretariat. http://www.env.gov.bc.ca/cas/
Ministry of Environment BC (2012) British Columbia greenhouse gas inventory report 2012. Victoria
Ministry of Environment BC (2016) BC Best practices methodology for quantifying green house gas emissions. Victoria
Nair S, George B, Malano HM et al (2014) Water-energy-greenhouse gas nexus of urban water systems: review of concepts, state-of-art and methods. Resour Conserv Recycl 89:1–10. doi:10.1016/j.resconrec.2014.05.007
Natural Resources Canada (2014) Retrofitting. http://www.nrcan.gc.ca/energy/efficiency/buildings/eeeb/retrofit/4111. Accessed 1 May 2015
Peng C, Wang L, Zhang X (2014) DeST-based dynamic simulation and energy efficiency retrofit analysis of commercial buildings in the hot summer/cold winter zone of China: a case in Nanjing. Energy Build 78:123–131. doi:10.1016/j.enbuild.2014.04.023
Picco M, Lollini R, Marengo M (2014) Towards energy performance evaluation in early stage building design: a simplification methodology for commercial building models. Energy Build 76:497–505. doi:10.1016/j.enbuild.2014.03.016
Poel B, van Cruchten G, Balaras CA (2007) Energy performance assessment of existing dwellings. Energy Build 39:393–403. doi:10.1016/j.enbuild.2006.08.008
Priyadarsini R (2014) Energy performance of aquatic facilities in Victoria, Australia. Facilities 32:565–580. doi:10.1108/F-02-2013-0015
Ruparathna R, Hewage K, Sadiq R (2017) Economic evaluation of building energy retrofits: a fuzzy based approach. Energy Build 139:395–406. doi:10.1016/j.enbuild.2017.01.031
Rysanek AM, Choudhary R (2013) Optimum building energy retrofits under technical and economic uncertainty. Energy Build 57:324–337. doi:10.1016/j.enbuild.2012.10.027
SaskEnergy (2016) Commercial rates. http://www.saskenergy.com/business/comrates_curr.asp. Accessed 14 Jul 2016
Sasmita M (2010) Engineering economics and costing. PHI Learning, New Delhi
Seiler-Hausmann J-D (2004) Eco-efficiency and beyond: towards the sustainable enterprise. Greenleaf Publishing Limited, Sheffield
Shao Y, Geyer P, Lang W (2014) Integrating requirement analysis and multi-objective optimization for office building energy retrofit strategies. Energy Build 82:356–368. doi:10.1016/j.enbuild.2014.07.030
Sharma V, Al-hussein M, Asce M, et al (2008) Municipal infrastructure asset levels of service assessment. 193–200
Consulting Ltd. (2008) Feasibility study district of Elkford. Elkford
Steven Winter Associates Inc (2014) Net zero energy buildings. https://www.wbdg.org/resources/netzeroenergybuildings.php. Accessed 2 Oct 2016
Sydney Water (2011) Best practice guidelines for water management in aquatic leisure centres. Sydney, Australia
Torcellini P, Pless S, Deru M, Crawley D (2006) Zero energy buildings: a critical look at the definition. In: ACEEE Summer Study. National renewable energy laboratory, Pacific Grove
Township of Esquimalt (2013) Esquimalt recreation centre aquatic energy retrofit project. http://www.civicinfo.bc.ca/practices_innovations/l&i-ca-esquimalt.pdf. Accessed 21 Dec 2015
Trianti-Stourna E, Spyropoulou K, Theofylaktos C et al (1998) Energy conservation strategies for sports centers: part B. Swimming pools. Energy Build 27:123–135. doi:10.1016/S0378-7788(97)00041-8
Union Gas (2016) Gas supply charges. https://www.uniongas.com/~/media/aboutus/rates/business/rate10.pdf?la=en. Accessed 14 Jul 2016
United Nations Framework Convention on Climate Change (2016) Historic Paris agreement on climate change. http://newsroom.unfccc.int/unfccc-newsroom/finale-cop21/. Accessed 16 Mar 2016
United States Environmental Protection Agency (USEPA) (2014) Eco-efficiency analysis. http://www.epa.gov/sustainability/analytics/eco-efficiency.htm
US Department of Energy (2012) Solar ventilation air preheating. https://www.wbdg.org/resources/svap.php#om. Accessed 11 Jul 2016
US Department of Energy (2015) A common definition for zero energy buildings. Washington
Wang B, Xia X, Zhang J (2014) A multi-objective optimization model for the life-cycle cost analysis and retrofitting planning of buildings. Energy Build 77:227–235. doi:10.1016/j.enbuild.2014.03.025
Woo J-H, Menassa C (2014) Virtual retrofit model for aging commercial buildings in a smart grid environment. Energy Build 80:424–435. doi:10.1016/j.enbuild.2014.05.004
Wübbenhorst KL (1986) Life cycle costing for construction projects. Long Range Plan 19:87–97. doi:10.1016/0024-6301
Yu PCH, Chow WK (2007) A discussion on potentials of saving energy use for commercial buildings in Hong Kong. Energy 32:83–94. doi:10.1016/j.energy.2006.03.019
Zhao J, Zhu N, Wu Y (2009) The analysis of energy consumption of a commercial building in Tianjin, China. Energy Policy 37:2092–2097. doi:10.1016/j.enpol.2008.11.043
Zhivov A, Liesen RJ, Richter S et al (2013) Energy performance optimization for Army installations. Build Serv Eng Res Technol 34:87–101. doi:10.1177/0143624412462907
Acknowledgements
The authors would like to acknowledge FortisBC, the City of Penticton, and the collaborative research and development grants program of the Natural Sciences and Engineering Research Council (NSERC CRD) for funding this research. Last but not least, the authors sincerely acknowledge Mr. Phil Hawkes of FortisBC and Mr. Chris Schmidt of the City of Penticton for providing case study data.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ruparathna, R., Hewage, K. & Sadiq, R. Rethinking investment planning and optimizing net zero emission buildings. Clean Techn Environ Policy 19, 1711–1724 (2017). https://doi.org/10.1007/s10098-017-1359-4
Received:
Accepted:
Published:
Issue Date: