Introduction

Acetaminophen (ACT) is an antipyretic and analgesic medicine that reduces fever and relieve pain through inhibiting the synthesis of prostaglandins [1, 2]. However, long-term use or overdose of ACT may cause some severe harmful side effects including hepatocyte death, pancreas inflammation and kidney failure [3, 4]. As a result, it is highly necessary to set up a sensitive and stable method for ACT detection. Electrochemical analysis, especially for biological, clinical and environmental sample, has gained great popularity. Development of a sensitive and stable electrode modifier is of importance to overcome the low sensitivity of bare electrode. Various nanomaterials such as metal and metal oxide/metal hydroxide [5, 6], graphene [7], carbon nanotube [8], conductive polymer [9] and ionic liquid [10] have been used to modify bare electrodes for ACT detection. Houshmand et al. [5] studied electrocatalytic oxidation mechanisms of ACT on cobalt hydroxide nanoparticles modified GCE and successfully applied the sensor to analysis of ACT in human urine. Bui et al. [6] developed a sensor based on gold nanoparticles (AuNPs) and glutamic acid for detection of ACT in pharmaceutical. Higher electrocatalytic activity for ACT redox using graphitic-N-rich nitrogen-doped graphene was obtained than that of graphitic-N-free nitrogen-doped graphene by Cao et al. [7]. Alothman et al. [8] achieved simultaneous determination of ACT and dopamine using multi-walled carbon nanotubes modified GCE. It is conceivable that a modifier rich of Co, Au, N and CNTs is promising for ACT monitoring.

Metal-organic frameworks (MOFs), which are composed of inorganic metal irons/clusters and organic ligands, have drawn increasing attention in field of electrochemistry because of their large specific area, tunable internal pore size and functionalization [11, 12]. Zeolitic imidazolate frameworks (ZIFs), as a typical subgroup of MOFs, are rich of carbon, nitrogen and transition metals (e.g., Zn2+, Co2+). ZIFs can be synthesized cheaply and transformed conveniently into nitrogen-doped nanoporous carbon (NPC) for improving their conductivity and mechanical strength [13]. In addition, NPC derived from ZIFs has further proved of outstanding electrocatalytic activity in electrochemical fields. Gai et al. [14] synthesized NPC derived from ZIF-8 to modify the electrode for detection of ascorbic acid, dopamine and uric acid simultaneously. Yue et al. [15] fabricated Prussian blue/NPC/polypyrrole/GCE sensor for monitoring hydrazine based on carbonized ZIF-67. Although the single C-ZIF-8 or C-ZIF-67 has been applied in electrochemical analysis, electrochemical performance of the carbonized hybrid ZIFs like carbonized core-shell ZIF-8@ZIF-67 as well as the difference among them, has rarely been explored.

Inspired by the above, three kinds of carbonized ZIFs, namely C-ZIF-8, C-ZIF-67 and Co-NCNHP, were synthesized and comparatively studied. The best among the three, Co-NCNHP was then coupled with AuNPs via potentiostatic deposition to construct the sensor for electrochemically sensing ACT. The electrochemical parameters including the deposition time of AuNPs, pH value, scan rate, diffusion coefficient and catalytic rate constant for ACT on modifying sensor were optimized. The modified sensor was used to determine ACT in tablets and urine samples.

Experimental section

Reagents

Zinc nitrate hexahydrate (Zn(NO3)2·6H2O), cobalt nitrate hexahydrate (Co(NO3)2·6H2O), 2-methylimidazole (2-MeIm), HAuCl4·3H2O, acetaminophen (ACT) and chitosan were purchased from Aladdin Biochemical Technology Co. Ltd. (Shanghai, China, www.aladdin-reagent.com). The ACT was in 0.1 M phosphate buffer (PB, pH 7), which was made up of sodium phosphate dibasic and sodium dihydrogen phosphate. All the regents were used directly without further dispose and the aqueous solution was freshly prepared with deionized water.

Characterization

Scanning electron microscope (SEM) of Hitachi SU8010 (Hitachi, Japan https://www.hitachi.com/) and transmission electron microscope (TEM) of Hitachi HT7700 (Hitachi, Japan https://www.hitachi.com/) were used to explore the morphology and structure nature. X-ray diffraction (XRD) was measured on Bruker AXS D8 Advance diffractometer (Bruker, Germany, https://www.bruker.com/), N2-adsorption-desorption analysis was tested on MicroActive for ASAP 2460 (Micromeritics, USA, https://www.micromeritics.com/), X-ray photoelectron spectroscopy (XPS) was performed on Thermo Scientific ESCALAB 250Xi (ThermoFisher Scientific, USA, https://www.thermofisher.com/).

Electrochemical measurements

All the electrochemical measurements, including cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), and amperometric i-t curve method were performed via CHI 900 electrochemical workstation (Shanghai CH Instrument, China, http://www.chinstr.com/) at ambient temperature. A three-electrode system was used, which contained working electrode of glassy carbon electrode (GCE, diameter: 3.0 mm), counter electrode of platinum wire electrode, and the reference electrode of Ag/AgCl electrode. The electrochemical characterization of the different modified electrodes were analyzed by CV and EIS in 5 mM [Fe(CN)6]3−/4- (1:1) solution containing 0.1 M KCl. CV was taken between −0.1 and 0.6 V at a scan rate of 100 mV s−1, and EIS was obtained under an open circuit potential about 0.2 V, amplitude of 0.005 V and frequency range of 0.1 to 105 Hz. The electrochemical behavior of different modified electrodes for ACT sample (0.1 M PB, pH 7) were investigated by CV and DPV. CV was recorded between −0.1 and 0.8 V at a scan rate of 100 mV s−1. The DPV was analyzed from 0.1 to 0.6 V. Amperometric i-t curve was performed at 0.35 V with solution stirring rate of 1500 rpm.

Synthesis of Co-NCNHP

The method for synthesis of Co-NCNHP and other materials (ZIF-8, ZIF-67, ZIF-8@ZIF-67, C-ZIF-8 and C-ZIF-67) is largely on the basis of reference [16]. The detailed procedure is shown in Electronic Supporting Material.

Fabrication of Au/Co-NCNHP/GCE sensor

The bare GCE was polished with aluminum oxide powder (0.05 μm) slurry to mirror-like clearness. Then it was rinsed with water and dried at ambient temperature. After that, 1 mg Co-NCNHP was added into 1 mL chitosan aqueous solution (1‰ acetic acid, volume ratio) to get a suspension, 5 μL of which was dropped on the GCE surface before dried under infrared lamp. Afterwards, AuNPs were electrodeposited on the bottom of GCE via reduction of 5 mM HAuCl4·3H2O aqueous solution for 15 s at 0.4 V. The modified electrode was denoted as Au/Co-NCNHP/GCE. All the other sensors including C-ZIF-8/GCE, C-ZIF-67/GCE, Co-NCNHP/GCE, ZIF-8@ZIF-67/GCE and Au/GCE were fabricated by the same way. The procedure for fabrication of the sensor is shown in Scheme 1.

Scheme 1
scheme 1

The fabrication procedure and the reaction mechanism of the Au/Co-NCNHP/GCE for ACT detection

Preparation of real sample

The ACT tablet (labelled 300 mg per tablet, http://www.wtyy.com.cn/cn/) was obtained from local pharmacy. Firstly, each tablet was ground completely and dissolved with water under stirring. Then the sample solution was filtered by syringe filter membrane with the pore diameter of 0.45 μm. Lastly, the tablet sample solution was diluted with PB (pH 7) to different concentration (10 μM, 100 μM and 200 μM) of ACT sample. In the case of human urine sample, it was supplied from healthy volunteer (the first author of this paper) and diluted ten times with PB (pH 7) directly. Then the standard spiked method was used for calculation of ACT recoveries before DPV test.

Results and discussion

Choice of materials

Carbonized ZIFs, a kind of NPC, are widely applied in electrocatalytic field for their fascinating chemical and mechanical stability, as well as good electrical conductivity. Many merits cannot be retained through the synthesis by pyrolysis of a single ZIF. Pyrolysis of a core-shell ZIF-8@ZIF-67 was carried out for better electrocatalyst. This nanomaterial not only exhibits high specific surface area, large pore volume, but reveals highly graphitic structure. Besides, the Co, N and CNT are all existent at the same structure. When coupled to AuNPs, the composite material displays excellent electrochemical activity for ACT redox. Compared with other conducting polymers, or carbon nanomaterial or metallic oxide such as PPy, PANI, rGO, C-dots, ZnO and etc. Au/Co-NCNHP is endowed with the advantages of high sensitivity and robust stability. The difference between C-ZIF-8, C-ZIF-67 and Co-NCNHP was studied as well.

Physical characterization

The XRD patterns of C-ZIF-8, C-ZIF-67, Co-NCNHP and Au/Co-NCNHP are shown in Fig. 1a. For C-ZIF-8, there are two obvious peaks at 25° and 44°, which are assigned to the amorphous carbon. For C-ZIF-67 and Co-NCNHP, the (002) peak is shifted towards 26°, suggesting the presence of graphitic carbon. Peaks at 44.3°, 51.5° and 76.1°correspond to (111), (200) and (220) characteristic diffraction peaks of Co (JCPDS 15–0806) respectively. It manifests that we have synthesized the Co-NCNHP faultlessly. As shown in the pattern of Au/Co-NCNHP, the peaks of Au are located at 38.42° (111), 44.14° (200), 64.39° (220) and 77.48° (311). By contrast, the peaks of Co are somewhat weaker, which might be due to the chitosan and AuNPs covered on the Co-NCNHP partially. The result confirms that the AuNPs have been deposited onto Co-NCNHP evenly. The XRD characterization of synthesized ZIF-8, ZIF-67 and ZIF-8@ZIF-67 further proves the validation of our synthesis strategy, see Fig. S1 in Electronic Supporting Material (ESM).

Fig. 1
figure 1

(a) XRD patterns of synthesized C-ZIF-8 (black line), C-ZIF-67 (blue line), Co-NCNHP (red line) and Au/Co-NCNHP (green line). TEM images of (b) ZIF-8@ZIF-67 and (d) Co-NCNHP. (c) EDS mapping images of ZIF-8@ZIF-67. SEM images of (e) Co-NCNHP and (f) Au/Co-NCNHP

TEM and EDS mapping images in Fig. 1b and c reveal that C, N distribute evenly in ZIF-8@ZIF-67, whereas Zn is mainly located at the center, and Co is located around the Zn cluster, suggesting we have fabricated the core-shell ZIF-8@ZIF-67 structure. Figure 1d, e and Fig. S2 show that the synthesized Co-NCNHP is a hollow polyhedron (about 400 nm) with lots of CNTs. Note that, neither the single C-ZIF-8 nor C-ZIF-67 has CNTs (Fig. S3), which is in accordance with the reference [16]. Therefore, it can be concluded that we synthesized the Co-NCNHP with success. As shown in Fig. 1f and S4, AuNPs are located uniformly on the film of Co-NCNHP with the help of chitosan.

Three types of N can be noticed in N 1 s spectrum of Fig. 2a. These are assigned to pyridinic N (398.6 eV, 32.1%), graphitic N (401.3 eV, 39.2%) and oxidized-N (403.8 eV, 28.6%). It is clear that there is no pyrrolic N, because stability of the pyridinic N and graphic N is stronger than that of pyrrolic N [17]. The percentage of pyridinic N and graphic N is so high that it can improve the electrocatalytic activity and stability of Co-NCNHP [18]. Co 2p spectrum in Fig. 2b indicates that there are two peaks at 778.8 eV and 780.2 eV, corresponding to metallic Co and N-coordinated Co2+ (Co-Nx) respectively. The existence of Co and Co2+ is also helpful for ACT redox [5]. Other element characterization is shown in Fig. S5.

Fig. 2
figure 2

(a) N 1 s spectrum and (b) Co 2p spectrum of Co-NCNHP. (c) N2 adsorption-desorption isotherm (d) pore diameter distribution of the C-ZIF-8, C-ZIF-67 and Co-NCNHP

The specific surface area and pore distribution information are shown in Fig. 2c. The N2 adsorption-desorption curves of the three carbonized ZIFs present the IV type isotherms, with sharp appearance due to the microspores when the relative pressure (RP) under 0.05. Then the curves increase slowly when the RP is between 0.05 and 0.45. With the RP over 0.45, the hysteresis loops of desorption curves are observed, indicating the presence of abundant mesopores. This is also supported by pore diameter distribution in Fig. 2d, pore diameters of the three carbonized ZIFs being 3–5 nm. This pore distribution is beneficial for mass transport in aqueous electrolyte [18]. Table S1 presents the surface area and pore volume of the foregoing three carbonized ZIFs. Obviously, C-ZIF-8 possesses the largest BET surface area (1480 m2 g−1), while that of C-ZIF-67 is the smallest (278 m2 g−1). This may be due to the collapse of micropores for C-ZIF-67 caused by graphitization of amorphous carbon [19]. As expected, Co-NCNHP has a middle value of 461 m2 g−1, and the pore volume is the largest (0.77 cm3·g−1).

Electrochemical characterization of C-ZIF-8, Co-NCNHP and C-ZIF-67

To compare the electrochemical behavior of the carbonized ZIFs, we tested the three electrodes in potassium ferricyanide solution via CV scanning for successive 100 circles. The surface areas A of different electrodes were also calculated in the solution above. The detailed process and results are shown in the section of Results and discussion in ESM. Figure 3a shows that the highest anodic peak current density Ipcd of 0.69 mA cm−2 is achieved on C-ZIF-8/GCE, and the Ipcd of Co-NCNHP/GCE (0.67 mA cm−2) ranks the second. However, the peak separation △Ep of 207 mV on the C-ZIF-8/GCE is not as good as that of Co-NCNHP/GCE (△Ep = 130 mV). It suggests that the Co-NCNHP owns the second highest sensitivity and the best reversibility among them. The reasons may be illustrated as follows: for one thing, larger specific surface area results in more exposed active sites. Therefore, the catalytic efficiency for the target molecule will be improved [20, 21]. Large specific surface area value of the Co-NCNHP contributed to its good electrochemical activity. For another, the electrical conductivity mainly depends on the graphitic degree or some heteroatom in carbon nanomaterial [16, 22]. SEM, TEM, EDS mapping and XPS prove there are not only Co and N, but also lots of CNTs on Co-NCNHP, which contrasts to the C-ZIF-8 or C-ZIF-67. The reasons above illustrate the excellent electrochemical performance of Co-NCNHP. In order to examine the stability of the materials, we extracted the anodic peak current values from 1st, 20th, 40th, 60th, 80th, 100th circle of each electrode, and calculated the relative standard deviation (RSD) of C-ZIF-8/GCE, Co-NCNHP/GCE and C-ZIF-67/GCE, being 9.8%, 1.4% and 0.22%, respectively. C-ZIF-67 exhibits the strongest stability among them. This is probably because the graphitic carbon has a better stability than amorphous carbon. In consideration of the sensitivity and stability, the Co-NCNHP is the best electrocatalyst in this case.

Fig. 3
figure 3

(a) CV scans of successive 100 circles and (b) EIS of C-ZIF-8/GCE, Co-NCNHP/GCE and C-ZIF-67/GCE in 5 mM [Fe(CN)6]3−/4- (1:1) solution with 0.1 M KCl. Scan rate: 100 mV s−1

To evaluate the electron conductivity of the three kinds of carbonized ZIFs, we further measured the electrochemical impedance of them. As shown in Fig. 3b, the smallest impedance value was obtained on Co-NCNHP (83 Ω), implying it possesses the best electron transfer ability among them. On the contrary, the C-ZIF-8 exhibits a weaker electron conductivity of 110 Ω.

The electrochemical behavior of different electrodes for ACT

The electrochemical behavior of the three carbonized ZIFs towards ACT was compared via CV. It is shown in Fig. 4a that the largest redox peaks densities and good reaction reversibility are obtained on Co-NCNHP/GCE. Fig. S6 shows there is a pair of redox peaks at 0.2 V for Co-NCNHP/GCE in PB, which is attributed to the redox of Co2+/Co3+ [23], revealing this reaction probably facilitates ACT redox. Therefore, Co-NCNHP was chosen for our further experiment.

Fig. 4
figure 4

(a) CV scans of C-ZIF-8/GCE, Co-NCNHP/GC and C-ZIF-67/GCE in 0.1 M PB (pH 7) containing 1 mM ACT. (b) CV scans of bare GCE, Au/GCE, ZIF-8@ZIF-67/GCE, Co-NCNHP/GCE and Au/Co-NCNHP/GCE in 0.1 M PB (pH 7) containing 1 mM ACT. Scan rate: 100 mV s−1

In order to improve the sensibility and stability of the sensor, we coupled AuNPs to Co-NCNHP by electrodeposition. The electrochemical behavior of the five electrodes were studied by CV in 1 mM ACT. As shown in Fig. 4b, Au/Co-NCNHP/GCE exhibits the largest redox peaks current densities compared with others. Only oxidation peak is observed on ZIF-8@ZIF-67/GCE. Redox currents densities of both Au/GCE and Co-NCNHP/GCE are larger than that of bare GCE. The anodic peak potential (Epa) and cathodic peak potential (Epc) of bare GCE are at 455 mV and 159 mV respectively, with a peak separation (△Ep) of 296 mV. Meanwhile, the △Ep values of Au/GCE, Co-NCNHP/GCE and Au/Co-NCNHP/GCE are 146 mV, 125 mV and 122 mV respectively. Therefore, the Au/Co-NCNHP presents good electron transport ability and catalytic rate toward the oxidation of ACT, and the electrochemical performance of Co-NCNHP is better than non-carbonized ZIF-8@ZIF-67.

The possible reaction mechanism for ACT on the Au/Co-NCNHP sensor is discussed as follows: (i) For Co-NCNHP, the large specific surface and pore volume lead to more active sites exposed, implying more targets can be adsorbed in a short time. The Co-NCNHP is rich of π electrons, which can strongly adsorb molecules with aromatic rings. In case of the Co, N and CNTs, not only are they helpful to improve the electron conductivity, but the redox of Co2+/Co3+ is likely to promote the ACT redox. (ii) The AuNPs are famous for their superior conductivity, large specific area, and stability. Hence, the AuNPs facilitate the electrocatalysis activity and conductivity of the interface. (iii) The synergistic effect between Co-NCNHP and AuNPs contributes to the excellent electrochemical redox of ACT. The probable reaction is described as Scheme 1.

Optimization of conditions

The following parameters were optimized: (a) sample pH value; (b) deposition time. Respective data and figures are given in Fig. S7a and b. The following experimental conditions were found to give best results: (a) best sample pH value: 7; (b) deposition time: 15 s.

Effect of scan rate

Effect of scan rate toward ACT redox on the sensor was also investigated. Fig. S7c displays that the redox peak current is proportional to the square root of scan rate. The liner equation between Ipa, Ipc and scan rate is expressed as Ipa (μA) = 7.0593 v [(mV·s−1)1/2] - 13.7680, Ipc (μA) - 3.7750 v [(mV·s−1)1/2] + 7.2457. It reveals the process of ACT redox on the Au/Co-NCNHP/GCE is controlled by diffusion.

Chronoamperometry determination of ACT

The ACT oxidation at the sensor was also studied by chronoamperometry (Fig. S7d). The catalytic rate constant and diffusion coefficient are two important parameters for electrochemical reaction. The catalytic rate constant can be calculated by the equation:

$$ \frac{I_{cat}}{I_l}={\left(\pi {k}_{cat} ct\right)}^{1/2} $$
(1)

Where Icat stands for the catalytic current produced on the Au/Co-NCNHP/GCE for ACT. IL means the limited current in absence of ACT. c and t are the bulk concentration of ACT solution and the time, respectively. From the left insert of Fig. S7d, we can obtain the Kcat of 4.94 × 105 M−1 s−1. Besides, from the equation:

$$ I=\mathrm{nFA}{D}^{1/2}c{\pi}^{-1/2}{t}^{-1/2} $$
(2)

Where I (A) refers to the peak current, n is the number of electron taking part in the redox, A (cm−1 s−1) is the efficient area of electrode, D(cm2 s−1) is the diffusion coefficient, and c (mol L−1) is the concentration of ACT. We can also evaluate the diffusion coefficient D of 1.81 × 10−6 cm2 s−1.

Quantitative determination of ACT

The feasibility of the Au/Co-NCNHP/GCE in ACT determination was validated by DPV. As presented in Fig. 5a, the anodic peak current is in proportion to the concentration of ACT with two linear segments. The linear equations are as follows: Ipa (μA) = 0.2189C (μM) + 0.3275 (0.1–40 μM, R2 = 0.9909), Ipa (μA) = 0.0389C (μM) + 7.3028, (40–250 μM, R2 = 0.9952). The LOD is 0.05 μM, and the sensitivity of 1.75 μA μM−1 cm−2. The method is compared with others as listed in Table 1 [24,25,26,27,28,29,30,31,32,33]. It is noticed that the linear range and LOD of the Au/Co-NCNHP/GCE are comparable to many other methods. The result suggests that both the Co-NCNHP and the AuNPs improve the electrochemical activity of the sensor for ACT determination.

Fig. 5
figure 5

(a) DPV response of Au/Co-NCNHP/GCE in 0.1 M PB containing different concentration of ACT (0.1, 0.5, 1, 5, 10, 20, 40, 60, 100, 150, 200, 250 μM, pH 7). Insert plot is the calibration plot of ACT. (b) Amperometric response towards 1 mM ACT in presence of 4-Nitrioaniline (5 mM), Phecantin (5 mM), 4’-Chloroacetanilide (5 mM), Glucose (10 mM), Rutin (1 mM), uric acid (UA, 1 mM) in 0.1 M PB (pH 7.0). Voltage: 0.35 V. Stirring rate: 1500 rpm

Table 1 Comparison of different electrodes for determination of ACT

Selectivity, reproducibility and stability

Selectivity is an important feature of the sensor to detect target with many interferences. In order to examine the selectivity, chemical structure-related drugs like 4-Nitroaniline (5 mM), Phenacetin (5 mM), 4’-Chloroacetanilide (5 mM), and some common biological substances with the close redox potential such as glucose (10 mM), rutin (1 mM), uric acid (UA, 1 mM) were used as the interference towards 1 mM ACT in 7 mL PB with the stirring speed of 1500 rpm. The volume of each substance was 100 μL and the time interval of adding the samples was 50 s. Figure 5b demonstrates the interference have no significant impact on the target of ACT. The relative error is less than ±5.0%, indicating a good selectivity of the sensor. As for the reproducibility, as shown in Fig. S8, Table S2, the RSD for ACT determination is 1.6% at the same electrode (n = 5). As for different electrodes (n = 5), the mean RSD is 4.5%. To study the long-term stability, the modified sensor Au/Co-NCNHP/GCE was stored in refrigerator at 4 °C for ten days, then used to detect ACT. As shown in Fig. S9, the peak current retained about 90.0% of the initial peak current (RSD = 3.0, n = 3). So the long-term stability of the sensor is not so good. The reason may be due to the effect of chitosan binder or the storage condition. The long-term stability of the sensor can be improved by using other binder or eletrodeposition method or changing the storage condition.

Real sample analysis

To estimate the practical application of Au/Co-NCNHP/GCE, tablet sample and urine sample were analyzed with the sensor by DPV. Table 2 reveals that the recoveries of tablet sample are between 97.0%–105.2%, and the recoveries of urine sample are from 96.0% to 102.6%, indicating a great potential for determination of ACT in real samples.

Table 2 Determination of ACT in tablets and human urine

Conclusions

We compared the electrochemical property of three carbonized ZIFs, and fabricated a novel Au/Co-NCNHP/GCE electrode for ACT determination. Due to the synergistic effects of Co-NCNHP and AuNPs, the sensor exhibits a good selectivity and reproducibility. For ACT determination in ACT tablets and spiked urine samples, satisfactory recoveries were received. The work provides a reference for the carbonized ZIFs to detect other substances of biologic interest, as well as an approach to detect the ACT in real sample. For the limitation of the method, more efforts should be made to investigate the aging process of the sensor and improve the long-term stability in future.