1 Introduction

As the primary carrier of chain branching and propagation reactions, the hydroxyl radical, OH, is one of the most important intermediate species in hydrogen and hydrocarbon combustion chemistry. Consequently, there is a strong need in the combustion community for the ability to accurately measure OH at elevated temperatures. Previous researchers have demonstrated the use of laser-induced fluorescence [1,2,3,4,5,6,7], emission [8,9,10,11,12,13] and absorption [14,15,16,17,18,19,20,21,22,23,24,25] spectroscopy, at both UV [1,2,3,4,5,6,7,8, 10,11,12,13, 16,17,18,19,20,21,22,23,24,25] and IR [9, 14, 15] wavelengths, for OH measurements in flames [1, 2, 4, 5, 9,10,11,12,13], engines [3, 6, 7] and shock tubes [16,17,18,19,20,21,22,23,24,25]. Among these various OH diagnostic methods, UV-laser absorption spectroscopy is particularly useful as it can provide sensitive, quantitative, and time-resolved measurement of OH concentration.

A comprehensive survey of the OH absorption spectrum suggests that the strongest OH transitions at combustion-relevant temperatures are within the A2Σ-X2Π (0,0) rovibronic band in the UV (see Fig. 1) (according to HITRAN 2016 [26], the strongest IR transition is at least two orders of magnitude weaker). Several transitions in this band have been previously explored for sensitive OH detection [26,27,28,29], of which the R1(5) transition particularly merits mention. Although not the strongest transition in the A-X(0,0) band, R1(5) has historically been used for many quantitative measurements of OH in combustion research (e.g., [18, 19, 22,23,24,25]) due to its relative ease of access with frequency-doubled dye lasers, especially when stronger OH transitions were beyond conventional laser tuning ranges.

Fig. 1
figure 1

Simulated linestrengths of OH A2Σ – X2Π (0,0) transitions at 1000 K (left) and 2000 K (right). Note that the Q1(5) transition selected in the current study is one of the three strongest transitions in the entire band. Simulations performed using the spectroscopic parameters from Goldman and Gillis [30]. LIFBase [31] predicts similar results

Very recently, advances in solid-state laser technologies have provided alternative UV light sources and enabled access to other OH transitions, including the strongest ones at combustion-relevant temperatures in the entire A – X (0,0) band: Q1(4) at 308.42 nm, Q1(5) at 308.61 nm, and Q1(6) at 308.82 nm. As such, we were motivated to revisit the spectroscopy and to develop an optimized UV absorption diagnostic for OH. The current study focuses on the Q1(5) transition, which is optimal for OH measurement over 1265–1880 K.

2 OH absorption spectroscopy

In a laser absorption measurement, the mole fraction (χ) of OH in a test gas mixture can be determined from the logarithmic attenuation of the laser intensity (− ln(I/I0)), also known as absorbance (α), via the Beer–Lambert relation: α = χkPL, where P is the total pressure of the test gas, L is the (assumed uniform) absorption pathlength, and k is the OH absorption coefficient, a spectroscopic parameter that is dependent on temperature, pressure, and wavelength. The current study targeted a distinctive and isolated absorption transition of OH for which k could be interpreted in a relatively simple manner: k = S(T)φ(ν,T,P), with S being the integrated linestrength (in units of cm− 2 atm− 1) and φ being the spectral lineshape function (in cm units). The temperature dependence of the linestrength S, relative to a reference temperature of choice, T 0 , is given by

$$\frac{{S\left( T \right)}}{{S\left( {{T_0}} \right)}}=\frac{{Q\left( {{T_0}} \right)}}{{Q\left( T \right)}}\left( {\frac{{{T_0}}}{T}} \right)\exp \left[ { - \frac{{hc{E^{\prime \prime }}}}{k}\left( {\frac{1}{T} - \frac{1}{{{T_0}}}} \right)} \right]\left[ {1 - \exp \left( { - \frac{{hc{\nu _0}}}{{kT}}} \right)} \right]{\left[ {1 - \exp \left( { - \frac{{hc{\nu _0}}}{{kT}}} \right)} \right]^{ - 1}},$$
(1)

where Q is the OH partition function, E″ and v0 are the lower-state energy and the line-center frequency of the OH absorption transition, and h, c, k are Planck’s constant, the speed of light, and Boltzmann’s constant, respectively. Regarding the Q1(5) transition explored in the current study, values of E″ and v0 have been determined with high accuracy in the work of Goldman and Gills [30]: E″ = 544.809 cm− 1 and v0 = 32403.405 cm− 1. Q(T) has also been tabulated by Goldman and Gills, with a minor correction for anharmonic oscillator effects discussed later by Goldman [32]. Over 1000–4000 K, in the current study, Q(T) is fitted with the following polynomial expression, which is valid over 1000–4000 K within ± 0.3% error:

$$Q\left( T \right)=~11.367+1.194 \times {10^{ - 1}}T/K+1.364 \times {10^{ - 5}}{(T/K)^2}+1.600 \times {10^{ - 9}}{(T/K)^3}.$$
(2)

To place absorption measurements on an absolute basis, one needs to know the precise value of S at the reference temperature T0. However, S(T0) was conventionally calculated from the Einstein A coefficient, which was typically determined on a relative basis (e.g., Chidsey and Crosley [33]) with respect to a particular vibrational/rotational state (e.g., the N′ = 0, v′ = 0 state whose natural lifetime was measured by German [34]). The current study is hence motivated to provide a direct measurement of the linestrength S for the OH Q1(5) transition, particularly at a temperature representative of combustion situations.

Another prerequisite for quantitative and accurate measurement of OH concentration is a detailed understanding of the spectral lineshape, φ. Under the current experimental conditions, the lineshape is affected simultaneously by contributions from Doppler and collisional/pressure-broadening and can be described by a Voigt profile: \(\phi =2\sqrt {\ln 2} V(x,a)/\sqrt \pi \Delta {\nu _{\text{D}}}\), where \(\Delta {\nu _{\text{D}}}=5.629 \times {10^{ - 3}}\;{(T/K)^{1/2}}\;{\text{c}}{{\text{m}}^{ - 1}}\) is the Doppler linewidth (FWHM) of the Q1(5) transition, V(x,a) is the normalized Voigt function, \(x=~2\sqrt {\ln 2} \left( {\nu - {\nu _0} - \delta \, \cdot \,P} \right)/\Delta {\nu _{\text{D}}}\) is the normalized frequency detuning relative to line center, and \(a=\sqrt {\ln 2} \Delta {\nu _{\text{C}}}/\Delta {\nu _{\text{D}}}\) is a measure of the relative scale of the collisional vs. the Doppler linewidth. The collisional linewidth \(\Delta {\nu _{\text{C}}}\) is proportional to the pressure of the collisional partner of OH, i.e., \(\Delta {\nu _{\text{C}}}=2\gamma \left( T \right)\, \cdot \,P\). To accurately model the lineshape of the OH Q1(5) transition at various temperatures and pressures, it is necessary to characterize the lineshape parameters δ (the pressure-shift coefficient) and 2γ, which is another objective of the current study.

3 Experimental method

High-temperature OH absorption measurements were conducted in a 15.24-cm diameter high-purity shock tube utilizing a state-of-the-art solid-state UV laser, as illustrated in Fig. 2. Known concentrations of OH radical were generated by shock-heating a 0.1% H2/ 0.1% O2/Ar mixture. The mixture was manometrically prepared in a 40-L mixing tank using a double-dilution procedure described in our earlier work [35]. Between shock experiments, the shock tube and mixing assembly were routinely evacuated to less than 6 µtorr to remove possible residual impurities. Further details about this Stanford shock tube facility have been documented in our previous study [36] and are not repeated here.

Fig. 2
figure 2

Schematic of the experimental setup used in the current study

The UV-laser diagnostic was accessed through a pair of windows located 2 cm away from the shock tube endwall. To access the OH Q1(5) transition near 308.61 nm, the current diagnostic employed a sum–frequency-generation (SFG) solid-state laser system, which consisted of four different components: a 10-W CW 532-nm pump laser (Lighthouse Photonics Sprout™), a Ti:sapphire resonator (M-Squared™ SolsTiS), a frequency- and polarization-stabilized CW 532-nm laser (Coherent Verdi™ V-5, with a maximum power of 5.5 W), and a frequency mixing/SFG module (M-Squared™ ECD-X). The Ti:sapphire resonator was optically pumped by the 10-W 532-nm laser to generate about 2 W of laser radiation at 734.48 nm, which was fed into the SFG module together with the stabilized 532-nm laser for frequency mixing, and the resulting 308.61-nm UV output (up to 300 mW achievable, but set to about 10 mW in the current study to avoid detector damage) was directed to the shock tube for OH measurement.

Wavelength tuning of the UV laser was achieved by adjusting the output wavelength of the Ti:sapphire resonator using the M-Squared™ control software. While a rapid wavelength-scanning measurement strategy is still under development, this study adopted a fixed-wavelength direct-absorption strategy—the laser was tuned to a target wavelength and kept constant during each reflected shock wave experiment. The actual wavelength of the Ti:sapphire resonator output was monitored in real time with a Burleigh™ WA-1000 wavemeter, which had a spectral resolution of 0.01 cm− 1. Both the Ti:sapphire resonator and the SFG module were stabilized with active feedback control to minimize wavelength and intensity drifts (less than ± 0.01 cm− 1 within 30 min and less than ± 0.5% within 100 s, respectively). Using a flip mirror, the UV laser was also guided through a low-pressure (< 10 torr) flowing H2O/He microwave discharge cell. This microwave discharge served as a room-temperature OH source with negligible pressure-induced spectral shift and hence provided a good spectral reference for the OH line center.

Transmitted UV-laser intensities through the shock tube and the discharge cell were measured with Thorlabs™ PDA36A Si switchable-gain detectors (20 dB gain setting, f− 3dB = 1 MHz). A UV beam splitter redirected part of the beam onto a bandwidth-matched reference detector whose signal was used to normalize the diagnostic detectors signals. This scheme, typically referred to as common-mode rejection, successfully reduced the laser intensity noise to less than ± 0.1%. To block the emission of the shock-heated gas or the microwave discharge, a set of UV bandpass filters (Newport™ FSR-UG5) were placed in front of the diagnostic detectors; similarly, an iris was placed in front of the reference detector to block background light. The detector signals were digitally sampled with a 14-bit data acquisition system (National Instruments™ PXIe-5122) at 100 MS/s for anti-aliasing, and low-pass-filtered to 1.25 MHz to reduce bit-noise and electronic noise. Note that 1.25 MHz was still higher than the detectors’ bandwidth (1 MHz), so that the temporal resolution was never compromised.

4 Results and discussion

A direct comparison of OH absorption signals, measured at the peaks of the Q1(5) and R1(5) transitions in two nearly identical reflected shock experiments, is shown in Fig. 3. A mixture of 0.1% H2/0.1% O2/Ar was shock-heated to temperatures of approximately 2010 K and pressures of 1.16 atm. OH was generated through the oxidation of hydrogen, and its concentration rapidly reached a plateau of 165 ppm. This value was determined from the R1(5) measurement using OH absorption coefficient characterized in previous studies [29, 37], and was in excellent agreement (within ± 3 ppm difference) with predictions of several reaction models, such as Aramco 2.0 [38], USC Mech II [39] and the Li et al. model [40]. As evidenced, the current Q1(5) diagnostic yielded a much stronger (a factor of 2.24 ± 0.08) absorption signal compared to our previous R1(5) diagnostic.

Fig. 3
figure 3

OH absorbance time histories measured at the Q1(5) and R1(5) peaks during shock tube oxidation experiments in a 1000 ppm H2/1000 ppm O2/Ar mixture. Post-reflected-shock condition: T = 2012 ± 5 K, P = 1.16 ± 0.01 atm, χOH,peak = 165 ± 3 ppm. Note that the Q1(5) transition selected in the current study is more than 2.2 times the strength of our previously used R1(5) transition

These experiments allowed for direct measurement of the OH absorption coefficient. Moreover, we have also mapped out the absorption lineshapes of the OH Q1(5) transition by repeated reflected shock experiments at similar temperatures and pressures but with slight offsets in wavelength. Figure 4 shows the measured Q1(5) lineshapes at T = 2008 K, P = 1.16 and 4.06 atm. Notably, the OH absorption spectrum became broader and slightly shifted to the low-frequency side at higher pressures. By fitting the measured lineshapes with Voigt profiles, we have determined the integrated linestrength (S), the Ar-broadening (2γAr) and the Ar-shifting (δAr) coefficients of the Q1(5) transition at 2008 K, as shown in Table 1. A more sophisticated model of the OH absorption spectrum could incorporate speed-dependent lineshape [41] and collision-induced narrowing [42], however, according to the previous studies of Rea et al. [29] and Herbon [37], these effects were small (less than ± 2% deviation from the Voigt profile) at the current experimental conditions and hence were omitted in this study.

Fig. 4
figure 4

Spectral lineshapes of the OH Q1(5) transition at T = 2008 K, P = 1.16 and 4.06 atm. Symbols: current data; lines: current Voigt fit. Error bars denote 1−σ uncertainties in laser frequency (horizontal ± 0.01 cm− 1) and OH absorption coefficient (vertical ± 2%)

Table 1 Spectroscopic parameters of the OH Q1(5) vs. R1(5) transitions at T = 2008 K

Similar values of 2γAr are observed between the Q1(5) and R1(5) transitions, which is expected due to the same lower-state rotational quantum number (J” = 5.5) shared by these two transitions. The similarity in δAr, however, is perhaps a coincidence [cross-over of Q1(J”) and R1(J”)], as the J"-dependence of δAr is generally different for each branch [37]. The uncertainties in current determinations of 2γAr and δAr are dominated by the spectral resolution of the fixed-wavelength measurements. Future experiments are planned to improve the accuracy of these measurements using rapid wavelength scanning.

The temperature dependence of the Q1(5) linestrengh S was determined from Eq. 1. To simplify the mathematical expression, the results have been fitted to the following form:

$$S(T)=\exp [6.81 - 1.71 \times {10^{ - 3}}T/K+2.59 \times {10^{ - 7}}{(T/K)^2} - 2.00 \times {10^{ - 11}}{(T/K)^3}]~\;{\text{c}}{{\text{m}}^{ - 2}}\;{\text{at}}{{\text{m}}^{ - 1}}.$$
(3)

The overall 1 − σ uncertainty in this expression, including both measurement uncertainty and fitting error, is estimated to be less than ± 4%. As for 2γAr and δAr, the previous studies of Rea et al. [29] and Herbon [37] suggested that for the OH transitions in the A – X (0,0) band, they generally follow a T− 0.8 dependence. Hence to the first-order approximation, and for the temperature range of current interest (about 1200–3000 K), we can express the Ar-broadening and Ar-shifting parameters of the Q1(5) transition as follows:

$$2{\gamma _{{\text{Ar}}}}\left( T \right)=0.034 \times {(2000\;K/~T)^{0.8}}\;{\text{c}}{{\text{m}}^{ - 1}}\;{\text{at}}{{\text{m}}^{ - 1}},$$
(4)
$${\delta _{{\text{Ar}}}}\left( T \right)= - 0.010 \times {(2000\;K/T)^{0.8}}\;{\text{c}}{{\text{m}}^{ - 1}}\;{\text{at}}{{\text{m}}^{ - 1}}.$$
(5)

Equations 35 provide a complete description for the OH absorption coefficient at Q1(5). To validate this spectroscopic model we directly measured the absorption coefficient and compared these data to the calculated values, as illustrated in Fig. 5. Excellent agreement is seen between the current measurement and model.

Fig. 5
figure 5

Peak OH absorption coefficients of Q1(5) and R1(5) at different temperatures (and pressures). Symbols: direct measurements. Lines: calculations based on the spectroscopic parameters listed above

The following expression is a numerical fit for the OH absorption coefficient at 32403.40 cm− 1 near the Q1(5) line-center:

$$\begin{aligned} k & =\exp (8.622 - 1.852{T_{\text{r}}} - 0.4328{P_{\text{r}}}+0.1786T_{{\text{r}}}^{2}+0.1994{T_{\text{r}}}{P_{\text{r}}}+0.0081P_{{\text{r}}}^{2}~ - ~0.0040T_{{\text{r}}}^{3} \\ & \quad - 0.0259T_{{\text{r}}}^{2}{P_{\text{r}}} - 0.0028{T_{\text{r}}}P_{{\text{r}}}^{2}+0.0002P_{{\text{r}}}^{3})\;{\text{c}}{{\text{m}}^{ - 1}}\;{\text{at}}{{\text{m}}^{ - 1}}, \\ \end{aligned}$$
(6)

where Tr = T/1000 K and Pr = P/1 atm are the reduced/non-dimensional temperatures and pressures. This expression should be valid over 1000–4000 K and 0.5–4 atm, with an estimated 1 − σ overall uncertainty of ± 5%. Under the typical pathlength (~ 15 cm) and minimum detectable absorbance (1 × 10− 3) of Stanford shock tube facilities, sub-ppm-level OH detectivity is easily achievable with the current diagnostic (see Fig. 6).

Fig. 6
figure 6

Projected 1 − σ detection limit of the current OH diagnostic as a function of T and P. Assuming an optical pathlength of 15 cm and a minimum detectable absorption of 0.1%

5 Example application

This new OH diagnostic is intended for use in future kinetics experiments, but here, we report on initial tests to demonstrate and validate its use in shock tube oxidation of dilute C3H8 mixtures. Exhibited in Fig. 7 are two example OH measurements at T = 1419 K and 1646 K, respectively. Even at these extremely low OH concentrations, signal-to-noise ratios of 10 or higher were readily achieved. Shown in comparison with the current measurements are kinetics simulations using the Aramco 2.0 mechanism [38], which is seen to be in excellent agreement with the measurements.

Fig. 7
figure 7

Example OH time histories measured during Ar-diluted stoichiometric oxidation of 20 ppm C3H8. Left: T = 1419 K, P = 1.40 atm. Right: T = 1646 K, P = 1.29 atm. In both cases, the 1 − σ detection limit of OH was less than 0.15 ppm. Excellent agreement is observed between the measurements and kinetics simulations performed using the Aramco 2.0 mechanism [38]

6 Conclusions and future work

In this study, we have developed a high-sensitivity diagnostic for OH using laser absorption at 308.61 nm, aimed particularly at shock tube applications. This new diagnostic utilizes the Q1(5) transition of the OH A – X (0,0) band, one of the strongest OH absorption transitions at elevated temperatures, and has improved the OH detection sensitivity relative to the previous R1(5) diagnostic by a factor of 2.24 ± 0.08. The OH absorption coefficient at the Q1(5) transition was measured behind reflected shock waves at various temperatures, pressures and wavelengths. From these measurements, we have also determined the linestrength and the Ar-broadening and -shift coefficients of this transition.

We have demonstrated the unprecedented sensitivity of this new diagnostic in highly-diluted C3H8 oxidation experiments, where a 1 − σ detection limit of less than 0.15 ppm OH was achieved. Future extensions of the current work will involve applications of this high-sensitivity OH diagnostic to shock tube kinetics studies and also will aim to address other spectroscopic questions. For example, we are interested in investigating use of the Q1(4) and Q1(6) transitions that are slightly stronger (by up to 15% and 5%) than Q1(5) over the temperature ranges of 800–1250 and 1900–2650 K, respectively. We would also like to explore possibilities of rapid wavelength scanning, with hopes of obtaining more accurate determinations of lineshape and shift coefficients.