Introduction

Hepatic steatosis is defined as the presence of at least 5% of fat containing hepatocytes on pathology [1]. It is the main manifestation of non-alcoholic fatty liver disease (NAFLD), whose incidence is increasing worldwide, especially in Western countries. An estimated 25% of adults have NAFLD worldwide [2, 3] with the highest prevalence in the Middle East and South America [4]. Hepatic steatosis is associated with several other conditions in particular alcohol abuse, chronic hepatitis C virus (HCV) infection, and receiving drugs such as chemotherapy [5].

Diagnosis of hepatic steatosis is crucial for patient outcome and management. Patients with NAFLD present with a high risk of associated comorbidities such as type 2 diabetes, cardiovascular disease, and obesity [6]. The pooled overall prevalence of diabetes and obesity among patients with NAFLD is estimated in more than 22% and 51% respectively [4], underling the close association between these pathological conditions. Moreover, steatosis may lead to the development of chronic inflammation (non-alcoholic steatohepatitis) and liver fibrosis, which may progress to cirrhosis or favor the development of hepatocellular carcinoma. In patients with HCV infection, the presence of steatosis accelerates the progression of liver fibrosis [7]. Marked steatosis is also a risk factor for major complications following hepatectomy [8, 9] and may contraindicate the use of the liver for cadaveric allografts [10].

Visual US assessment of hepatic parenchyma is accurate for the diagnosis of high-grade steatosis [11]. Indeed, a “bright liver” is a common finding for patients who undergo US examination to explore liver test abnormality. A significant part of these patients ends up being diagnosed with NAFLD, underlying the clinically value of B-mode US. Nevertheless, the diagnostic performance and the interobserver agreement of this method can decrease when diagnostic threshold is based on low degrees of steatosis (5%) [12].

In the past few years, a transient elastography-derived technique, the controlled attenuation parameter (CAP), has been developed [13]. This approach assesses steatosis by quantifying the total ultrasonic attenuation (go-and-return path) produced by the transient elastography device in the liver (expressed in dB/m) [13]. Nevertheless, a high number (up to 7.7%) of non-valid measurements are a major clinical limitation to CAP [14]. Moreover, CAP measurements are not image-guided. Like CAP, attenuation imaging (ATI) is based on the assumption that ultrasound attenuation can be used as proxy for the assessment of hepatic steatosis. ATI allows the calculation of the attenuation coefficient (AC—expressed in dB/cm/MHz), which expresses the variation of US intensity in the depth. We hypothesized that AC quantification may be valuable for the non-invasive diagnosis and quantification of hepatic steatosis. Yet, ATI differs from CAP because it is coupled with high-end real-time B-mode US that enables simultaneous visualization and clinical exploration of the hepatic parenchyma. AC measurements can be easily obtained by placing a ROI in a color box map. While the AC has been found to be promising for the quantification of steatosis [15, 16], its diagnostic value is largely unknown. The aim of this study is to prospectively assess the diagnostic performance of AC for the detection and quantification of hepatic steatosis using liver biopsy as the reference method

Material and methods

Patient selection

This study and the protocol review were approved by the local IRB, and patients provided informed consent. From April 2017 to February 2018, all patients scheduled for a liver biopsy in the Department of Radiology of Beaujon Hospital, Clichy, France, also underwent an ultrasound examination with measurement of the AC on the same day. AC quantification was performed immediately before the biopsy. When liver biopsy was indicated for tumor characterization, patients were only enrolled in the study if a biopsy of the adjacent liver was required so that the presence of steatosis and fibrosis could be evaluated. The flowchart is described in Fig. 1. Demographics, clinical, biological, and pathological data were extracted from the medical charts.

Fig. 1
figure 1

Patient flow chart

Attenuation imaging

For this study, US examinations were performed by using a clinical US scanner (Aplio i-800, Canon Medical System) with a i8CX1 1–8-MHz curved US transducer used for conventional B-mode examination. ATI technology is based on the attenuation of longitudinal sound waves while travelling through tissue. In this study, a setting for the ultrasound frequency in the range of 3.0 MHz has been selected. The ATI algorithm uses information of beam attenuation from the inside of the entire “ATI box” which is displayed over the normal B-mode image and color coded. ATI produces an average attenuation value including a quality measure that measures the correlation of the attenuation with the depth (goodness of fit—R2). Therefore, it is important to minimize areas of inhomogeneity (such as vessels or focal lesions) in the “ATI box” as well as to avoid zones that contain strong reverberation signals. Regions with significant calculation errors (such as blood vessels) are automatically excluded from the map. When a ROI is placed in the ATI box, the software automatically measure the AC expressed in dB/cm/MHz (extracting the focus-dependent beam profile and internal gain control from the observed intensity on the ultrasound image to remove influence of the system on signal intensity). One operator performed the AC measurements for each patient (M.D.B. with 8 years of experience in the field of liver imaging) following recommendation for good practice provided by the manufacturer. ACs were computed during neutral apnea, by right intercostal approach. The operator was asked to manually place the ROI in the color-coded ATI box below the liver capsule to maximize the coefficient of determination (R2) (Fig. 2). Care was taken during measurement to avoid any capsular artifacts (displayed in red in the superior part of the box—Fig. 2a) and the presence of large vessels. Two measurements with R2 > 0.90 were obtained from each patient and averaged to obtain the AC values used for statistical analysis. The cutoff value of 0.90 was also provided by the manufacturer. If two measurements could not be obtained with R2 > 0.90, this was considered a technical failure (Fig. 2). Raw data were stored in a secure external hard drive.

Fig. 2
figure 2

Ultrasound attenuation imaging coefficient measurement in a 59-year-old female patient. A linear area of high attenuation due to a capsular artifact is visible in the superior part of the image (a, arrow). Three measurements were performed in this patient. The highest R2 were obtained in the first (a) and third (c) measurements. Part (b) shows the second measurement with R2 < 90 (automatically highlighted in yellow) that was not retained for AC calculation. The mean attenuation coefficient obtained from averaging the first and third acquisitions was 0.78 dB/cm/MHz, indicating the presence of mild to moderate steatosis. Biopsy showed 20% steatosis (S1)

Pathological evaluation

Pathological analysis was performed by a pathologist expert in the field of liver diseases. The grade of steatosis (S) was assessed for each patient according to Brunt et al from S0 to S3 by quantification of lipid droplets in the hepatocytes as follows: absent (S0) < 5%, mild (S1) 5 to 33%, moderate (S2) 33 to 66%, and severe (S3) > 66% [17]. Liver fibrosis (F) was classified as absent (F0), mild (F1, perisinusoidal or periportal), moderate (F2, periportal and perisinusoidal), F3 (bridging fibrosis), and F4 (cirrhosis) according to METAVIR [18].

Statistical analysis

The primary endpoint of the study was the diagnostic performance of AC for the diagnosis and quantification of hepatic steatosis. In the absence of previously published study using the same ATI technology and the same reference method (i.e., liver biopsy), sample size calculation was not possible. Data were expressed as means ± standard deviations and ranges or n (%) as appropriate. The Pearson correlation coefficient between ACs and the percentage of steatosis on pathology was calculated. Correlations were graded as follows: r = 0–0.2, very low; r = 0.4–0.6, reasonable; r = 0.6–0.8, high; and r = 0.8–1.0, very high. The Student t test or the Mann–Whitney U test was used to compare continuous variables, as appropriate (the d’Agostino–Pearson test was used to asses normality). Receiver operating curve (ROC) analysis was performed to evaluate the diagnostic performance of the AC for detecting the presence of any grade of steatosis (S0 vs. S1–S3) or the presence of moderate to severe steatosis (S0–S1 vs. S2–S3). Optimal AC cutoff values were identified by maximizing the Youden index, and corresponding sensitivities and specificities were derived. The DeLong test was used to compare the AUCs. One-way ANOVA was used to compare ACs according to the grades of steatosis, and a post hoc pair-wise comparison was performed using the Student–Newman–Keuls test. All tests were considered to be statistically significant in case of p < 0.05, except for pair-wise comparisons where p < 0.0125 was used. All tests were performed using dedicated software (MedCalc version 11.5.1.0).

Results

Patient characteristics

Patient characteristics are summarized in Table 1. The final population included 101 patients (63 men [62%] and 38 women [38%]), mean age 59 years old (25–89). Liver biopsy was performed to characterize focal liver lesions in patients with (n = 31) or without (n = 33) chronic hepatitis, to explore patients with a suspected diagnosis of NAFLD (n = 21), or to explore liver test anomalies (n = 16).

Table 1 Patient characteristics (N = 101)

Pathological analysis

According to pathological analysis, 43 (42%), 35 (35%), 12 (12%), and 11 (11%) patients were classified as S0, S1, S2, and S3, respectively. Thirty-six (35%), 12 (12%), 8 (8%), 18 (18%), and 27 (27%) were classified as F0, F1, F2, F3, and F4, respectively.

Attenuation coefficient and hepatic steatosis

AC measurement technical failures (i.e., R2 < 90) occurred in 2/106 patients (1.9%) as shown in Fig. 1. The mean AC of the entire cohort was 0.71 dB/cm/MHz. There was a significant and positive correlation between the AC and steatosis on pathology (%) (r = 0.58, 95% confidence interval [CI] 0.44–0.70; p < 0.01)—supplemental Figure 1.

The mean AC was 0.63 ± 0.09, 0.71 ± 0.11, 0.87 ± 0.09, and 0.84 ± 0.13 dB/cm/MHz in patients with S0, S1, S2, and S3, respectively. The AC was significantly different for the different grades of steatosis (ANOVA p = <0.01, all pair-wise comparisons p < 0.01, except for S2 vs. S3, p > 0.05). Distribution of AC according to the different steatosis grades is detailed in supplemental Figure 2.

The AC in patients without steatosis on pathology (i.e., S0) was significantly lower than in those with any grade of steatosis (i.e., S1–S3) (0.63 ± 0.09 vs. 0.77 ± 0.13 dB/cm/MHz, p < 0.01—Fig. 3a). The AC in patients with moderate/severe steatosis (i.e., S2–S3) was significantly higher than in those without or with mild steatosis on pathology (i.e., S0–S1) (0.85 ± 0.11 vs. 0.67 ± 0.11 dB/cm/MHz, p < 0.01—Fig. 3b).

Fig. 3
figure 3

Box plot graph shows the distribution of attenuation coefficient (AC) values in patients without (S0) vs. patients with any grade of steatosis (S1–S3) (a) and in patients with no or mild steatosis (S0–S1) vs. patients with moderate or severe steatosis (S2–S3) (b). Boxes represent the 25th and 75th percentiles; whiskers represent the 5th and 95th. Dots are outliers. Mean AC was 0.63 ± 0.09 dB/cm/MHz for S0 vs. 0.77 ± 0.13 dB/cm/MHz for S1–S3 (p < 0.01) and 0.67 ± 0.11 dB/cm/MHz for S0–S1 vs. 0.85 ± 0.11 dB/cm/MHz for S2–S3 (p < 0.01)

Performance of AC for the diagnosis of hepatic steatosis

The areas under the ROC curve (AUROC) of the ACs for the diagnosis of any grade of steatosis and moderate to severe steatosis were 0.805 (95%CI 0.71–0.88, p < 0.01) and 0.892 (95%CI 0.81–0.94, p < 0.01), respectively (Fig. 4).

Fig. 4
figure 4

Receiver operating curve for the diagnostic performance of the attenuation coefficient (AC) in the diagnosis of the presence of any grade of hepatic steatosis (S1 to S3) (a) and the presence of moderate to severe steatosis (S2 to S3) (b). The areas under the ROC curve were 0.805 (95%CI 0.71–0.88, p < 0.01) and 0.892 (95%CI 0.81–0.94, p < 0.01) for the diagnosis of any grade of steatosis (S1–S3) and of moderate to severe steatosis (S2–S3), respectively

The sensitivity and specificity of an AC > 0.69 dB/cm/MHz (Fig. 4a) for the diagnosis of any grade of steatosis (S1–S3) were 76% (95%CI 63–85) and 86% (95%CI 72–95), respectively. The sensitivity and specificity of an AC > 0.72 dB/cm/MHz (Fig. 4b) for the diagnosis of moderate or severe steatosis (S2–S3) were 96% (95%CI 78–100) and 74% (95%CI 63–84), respectively. Using the AC cutoff of 0.69 dB/cm/MHz, 81/101 (80%) of patients were correctly classified as S0 or S1–S3. Using the AC cutoff of 0.72 dB/cm/MHz, 78/101 (77%) of patients were correctly classified as S0–S1 or S2–S3.

The AC rule-in threshold (100% specificity and 19% sensitivity) was > 0.90 dB/cm/MHz for the presence of any grade of steatosis (S1–S3), while the rule-out threshold (100% sensitivity and 0% specificity) was < 0.44 dB/cm/MHz.

Examples of AC measurements in two different patients are reported in Fig. 5.

Fig. 5
figure 5

Attenuation coefficient (AC) quantification measurement in a 71-year-old male patient (a) with non-alcoholic steatohepatitis and in a 50-year-old HIV-positive male patient (b) presenting with a focal liver lesion. For patient 1, AC was 0.90 dB/cm/MHz with high R2 (0.96) indicating the presence of severe steatosis that was confirmed on pathology (grade 3–70%). For patient 2, AC was 0.48 dB/cm/MHz with high R2 (0.92) indicating the absence of steatosis, which was confirmed by pathology (grade 0–0%)

Influence of fibrosis and BMI on attenuation imaging coefficient measurement

A total of 45/101 (44%) patients presented with advanced fibrosis on pathology (F3–F4). The AC of patients with advanced fibrosis (F3–F4) was not significantly different from that of patients with F0–F2 (0.72 ± 0.13 vs. 0.70 ± 0.13 dB/cm/MHz, p = 0.38).

For each separate class of steatosis, the mean AC was not found to be significantly different according to the presence of advanced liver fibrosis (F3–F4) or not (F0–F2). Detailed results are provided in Table 2.

Table 2 Influence of advanced (F3–F4) fibrosis on attenuation coefficient (dB/cm/MHz) values for each class of steatosis taken separately

Overall, 27 patients were obese (i.e., BMI ≥ 30), and 74 were not. Steatosis was more frequent in obese patients (24/27 [89%] vs. 34/74 [46%] in non-obese ones, p < 0.01). When present, steatosis was not more severe in obese patients (12/24 patients with S2–S3 [50%] vs. 11/34 [32%] in non-obese ones, p = 0.18).

The AUROC of AC for the diagnosis of any grade of steatosis was 0.79 ± 0.06 and 0.79 ± 0.10 in non-obese and obese patients, respectively (DeLong test, p = 0.95). The AUROC of AC for the diagnosis of moderate or severe steatosis was 0.85 ± 0.08 and 0.95 ± 0.04 in non-obese and obese patients, respectively (DeLong, p = 0.047).

Discussion

This study shows that ultrasound attenuation imaging is a promising tool for the diagnosis of steatosis, with a high sensitivity and specificity. The EASL guidelines recommend ultrasound as the first-line imaging technique to detect steatosis [1]. The qualitative evaluation of hepatic steatosis by US is usually obtained by comparing the echogenicity of the liver and kidney or evaluating several US features including attenuation of the ultrasound beam, vessel blurring, reduced visualization of the gallbladder wall and the diaphragm, and the presence of fatty sparing areas [19, 20]. However, the sensitivity of US for detecting mild steatosis [21, 22] is limited with a sensitivity and specificity of 73% and 84%, respectively, in a meta-analysis [12]. Moreover, and probably more importantly, the intra- and interobserver agreement of qualitative approaches is low [23]. Results are usually categorized on a 4-point scale (i.e., absent, mild, moderate, or severe steatosis). Thus, changes in the amount of steatosis over time cannot be confidently monitored by visual assessment of steatosis on US. This calls for accurate quantitative approaches that can be implemented into US scanners to be routinely used.

One quantitative approach is based on the use of elastography techniques that quantify liver stiffness via the speed of shear waves propagating in the liver. Transient elastography is routinely performed and is now part of clinical algorithms for the managements of patient with various liver diseases [24]. Yet, liver stiffness quantification is used for the assessment of liver fibrosis and portal hypertension, but not for the quantification of steatosis because it has been reported that stiffness values are not correlated with liver steatosis [25]. Nevertheless, this technique is coupled with the quantification of the US attenuation (the so-called CAP) that has been shown to accurately quantify steatosis [13, 26]. How performant CAP may be, it is limited by a rate of technical failure of up to 7.7% [14]. Moreover, it is not an imaging technique. ATI is based on the same assumption that ultrasound attenuation can be used as a proxy for the assessment of hepatic steatosis. Differently from CAP, ATI is coupled to a real-time B-mode visualization. On top of allowing conventional clinical exploration of the liver with high-quality images, it allows probe repositioning to obtain a good-quality images before attenuation measurements are performed. Indeed, real-time B-mode US helps the operator know exactly where the measurements are performed. This approach helps avoid the major artifacts in images (such as those induced by rib reverberation), large hepatic vessels, or focal liver lesions and finally to detect the presence of heterogeneous depositions of steatosis. This is confirmed by our results, since the rate of technical failures was very low (2% of patients in our study). Moreover, the performance of the AC for the diagnosis of any grade of steatosis (S1–S3) was good, similar to the results from recently published studies [15, 16]. The results of AC are also comparable to those of the CAP, which was found to have a pooled sensitivity of 78% and specificity of 79% for the diagnosis of steatosis in a recent meta-analysis [27]. In our study, sensitivity was found to be almost the same (76%) with greater specificity (86%). Finally, results were not altered by the presence of obesity.

Tada et al [15] investigated the diagnostic performance of AC for the diagnosis of steatosis using MRI-PDFF as the reference standard. They found that a cutoff value of 0.60 dB/cm/MHz had a sensitivity of 85.5% and specificity of 88.5% for the diagnosis of any grade of steatosis while a cutoff of 0.69 dB/cm/MHz had a sensitivity of 82.7% and a specificity of 81.1% for the diagnosis of moderate or severe steatosis. Our results show slightly higher cutoff values (0.69 and 0.72 dB/cm/MHz, respectively). These discrepancies may be due to the difference in reference technique in the two studies. Indeed, we used liver biopsy while Tada et al used MR-PDFF. Although PDFF is extremely accurate in diagnosing steatosis, there is no strict consensus on which PDFF cutoffs should be used to grade steatosis. Second, the manufacturer of the AC measurement was not the same in the two studies [15]. Finally, our patient population differed because we also included patients with chronic liver disease, which is a better reflection of clinical practice because many patients have both fibrosis and steatosis. Although our group was more heterogeneous due to the inclusion of patients with chronic liver disease, this allowed us to investigate the influence of fibrosis and cirrhosis on the measured AC value, which was one of the limitations of the study by Tada et al [15].

A recent publication from Bae et al [16] explored the potential role of ATI using liver biopsy as a reference standard. Reported results were close to ours, with similar diagnostic performance (AUC of AC of 0.80 vs. 0.84 for any grade of steatosis, and of 0.89 vs. 0.89 for S2–S3 steatosis) and similar optimal AC cutoff values (0.69 vs. 0.635 dB/cm/MHz for any grade of steatosis and 0.72 vs. 0.70 dB/cm/MHz for S2–S3 steatosis). This confirms the potential clinical role of the AC measurement with ATI for the diagnosis of hepatic steatosis. Noticeably, we used a more stringent R2 threshold to define technical failure (0.90 vs. 0.80 in the study from Bae et al [16]) explaining the slightly higher rate of technical failure in our study (2% vs. 0%). Finally, due to a higher rate of patients with significant fibrosis in our cohort, we could accurately show that significant fibrosis has no influence on AC value. In this setting, we believe that AC measurement could be added to US elastography to classify both steatosis and fibrosis, allowing this technique to be a comprehensive non-invasive tool for liver diseases.

This study has several limitations. First, the included population was heterogeneous, including patients with chronic liver disease from different etiologies and some with cirrhosis. It has been shown that CAP cutoff values are influenced by the etiologies of liver disease [26]. This must be assessed with ATI. For this reason, more studies including homogeneous cohorts are necessary. We did not compare AC measurements with other quantitative or semi-quantitative US methods such us semi-quantitative visual comparison of hepatic and renal echogenicity or hepatorenal index. Nevertheless, the aim of this study was to assess the ability of this new technique to detect steatosis. We observed an overlap between AC values, especially in patients with S2 or S3 steatosis. This may due to the limited number of patients with high degrees (S2–S3) of steatosis. Nevertheless, from a clinical point of view, this seems to be of limited consequence as ultrasound visual approach alone is performant to diagnose such high grades of steatosis. Moreover, patients with S2 do not differ from those with S3 in terms of management and possible treatment. The added value of ATI is to enable detecting small amounts of fatty deposition in the liver. Finally, our reference method for steatosis was liver biopsy, which can suffer from sample bias [28]. To the best of our knowledge, ATI is not available on other US scanners. This may limit its use but we are confident that, as for elastography, similar technology will be progressively implemented by other vendors.

In conclusion, this study shows that measurement of ultrasound AC is a promising quantitative method for the detection and quantification of hepatic steatosis.