Introduction

Intravoxel incoherent motion (IVIM) reflects the random microscopic motion that occurs in voxels on magnetic resonance (MR) images of water molecules (either intra-cellular or extra-cellular) and the microcirculation of blood [14]. Initially, it was claimed that signal attenuation as a function of b was mono-exponential in diffusion-weighted imaging (DWI), owing to a mono-compartmental model of water diffusion [1, 3, 5]. However, in 1988, le Bihan et al. [4] proved that it was possible to identify two different compartments of diffusion in the brain. According to IVIM theory, the fast component of diffusion (represented by D*) is related to microperfusion, whereas the slow component (represented by D) is linked to pure molecular diffusion. Owing to this bi-compartmental model, the signal decay of IVIM DWI was described using a bi-exponential model [4]. Though IVIM studies have long been limited to the brain due to technical limitations in moving organs [6], the door has recently opened on applications of IVIM in the liver [2, 715].

Interestingly, the liver is anatomically and physiologically different from the brain, and may be more complex. These differences include the presence of several vessel types (arteries/arterioles, portal veins/venules, hepatic veins/venules), sinusoid capillaries, bile ducts, a rich lymphatic system [16], and a functionally important intermediate area between the sinusoids and hepatocytes, called the space of Disse [16]. Flowing or moving spins are present in these compartments, which are directly or indirectly connected together. This could support the hypothesis that more than two diffusion compartments may exist in the liver [17].

However, bi-exponential modelling of the IVIM signal in a single patient or even in single voxels is known to be challenging [2, 9, 10, 12, 18] with a lack of reproducibility especially for D* calculations, owing to the limited sampling and signal-to-noise ratio (SNR). The increase in the degree of freedom of the IVIM model without both adequate sampling and improved SNR results in fitting failure. It has been proposed to average the data of several patients in order to improve the SNR [8, 19]. In order to keep individual data, the averaging over multiple data points per patient might also improve the data quality.

The aim of this study was to compare mono-, bi- and tri-exponential models without any assumption regarding their diffusion coefficient(s) in order to determine which of them best fits the IVIM signal of normal liver. To avoid drawing erroneous conclusions, we prospectively validated the results in another population of patients using a different IVIM sequence.

Materials and methods

The pilot and the validation studies were approved by our regional ethics committee. Written informed consent was obtained from all patients.

Pilot study

The pilot study included a series of type-2 diabetic patients with a presumed normal liver. Between December 2010 and September 2012, 149 consecutive patients were screened at the endocrinology department of our institution for type 2 diabetes. The inclusion criteria were: an age older than 18-years-old; body weight less than 150 kg; no known acute or chronic disease (other than diabetes) according to the patient’s medical history with physical examination and standard laboratory tests; alcohol consumption of less than 20 g per day; and no evidence of liver disease such as viral hepatitis. These patients underwent MRI as outpatients for their annual disease assessment or for educational purposes. Four patients were excluded for claustrophobia.

To ensure that patients enrolled in the pilot study had a normal liver, we excluded patients with >5 % liver steatosis (as evaluated on proton MR spectroscopy [2022]), those with a liver T2* lower than 15 msec (as calculated using triple-echo gradient-echo sequences [21, 22]), which reflects hepatic iron overload, and those with a Fibrotest® > F1 [2325]. Therefore, the pilot study was conducted in 38 patients (20 women and 18 men) with a mean age of 43.4 years (range: 20-79 years), a mean steatosis of 1.02 % (range: 0.14-4.59 %, SD: 0.9), and a mean T2* value of 19.95 msec (range: 16-27 msec; SD: 2.7).

MR Imaging

MR imaging was performed with a 3.0 T unit (Magnetom Trio; Siemens Erlangen, Germany) with a peak gradient amplitude of 45 mT/m and a time to peak of 204 μsec. A six-element body phased-array coil system was used. All patients were carefully instructed to suspend respiration in expiration and to be consistent in their breath-holds. To allow correct positioning, localizing sequences in the coronal, transverse, and sagittal planes were acquired during a breath-hold.

As mentioned above and as previously reported [21, 22], we performed seven proton-MR spectroscopic sequences (for correction of T2 decay) for the evaluation of steatosis, and a spoiled triple-echo gradient-echo sequence for T2* calculation (Appendix 1).

IVIM DW Imaging Sequence

The IVIM DW imaging sequence was performed during the same MR examination and was acquired using navigator-echo triggered PACE (prospective acquisition correction, Siemens Healthcare) single-shot echoplanar imaging (SS EPI) with twice-refocused bipolar diffusion preparation and 11 b values (Table 1).

Table 1 IVIM DWI sequence parameters

IVIM DW-MRI analysis

As previously underlined [26, 27], separating microperfusion from pure molecular diffusion requires a high SNR. With the aim to optimize this ratio, we measured the liver signal as follows. At each b value, the recorded SI was obtained by averaging the mean SI in a 1 cm-ROI in the right liver (avoiding extra-hepatic fat, large hepatic vessels or bile ducts) positioned by a radiologist (JPC, with 19 years of experience in liver imaging) on three slices. These ROIs were initially positioned on images with b = 0 s/mm2, then copied and pasted on each corresponding image for each b value.

Since we aimed to model a (presumed) normal liver, we recorded the signal values at each b level after normalization by attributing a value of 100 at b = 0 s/mm2 (Snorm = (SI/SI0)*100 where Snorm is the normalized signal, SI = signal at a given b value, and SI0 = signal at b = 0 s/mm2). Using this normalization, the Snorm value was independent from the signal value at b = 0 s/mm2, thus, giving the same weight to each patient in order to globally analyse the signal of a normal liver.

If diffusion is considered mono-compartmental, signal attenuation as a function of b is expressed using the following mono-exponential equation:

$$ SI=S{I}_0\cdot {e}^{-b\cdot ADC} $$

where SI is the signal intensity at the given b value, ADC is the apparent diffusion coefficient ,and SI0 is proportional to \( {e}^{-TE/T2} \).

According to IVIM theory [1, 2, 4], diffusion is considered bi-compartmental (pseudo-diffusion [also called perfusion-related diffusion] and pure molecular diffusion), which explains why signal attenuation as a function of b is expressed by a bi-exponential equation:

$$ SI=S{I}_0\cdot \left[{f}_1\cdot {e}^{-b\cdot {D}_1}+{f}_2\cdot {e}^{-b\cdot {D}_2}\right] $$
(1)

where f 2 (i.e., perfusion fraction usually called f) and f 1 (usually called (1-f)) represent the fraction of each diffusion compartment, D2 (usually called D*) represents perfusion-related diffusion, and D1 (usually called D) represents pure molecular diffusion.

If diffusion is considered as tri-compartmental, signal attenuation is expressed by the following tri-exponential equation:

$$ SI=S{I}_0\cdot \left[{f}_1\cdot {e}^{-b\cdot {D}_1}+{f}_2\cdot {e}^{-b\cdot {D}_2}+{f}_3\cdot {e}^{-b\cdot {D}_3}\right] $$

Where f 1 , f 2, and f 3 represent the fractions of each diffusion compartment (f 1 + f 2 + f 3 = 1) and D1, D2, and D3 represent the diffusion / pseudo-diffusion coefficient of each compartment.

Then to avoid erroneous conclusions, we validated the results in a prospective series of patients.

Validation study

The validation study prospectively included type-1 diabetic patients with a presumed normal liver. Between December 2012 and October 2013, 61 consecutive patients were screened at the endocrinology department of our institution for type 1 diabetes. The inclusion criteria were exactly the same as those used for the pilot study. These patients were imaged as outpatients for annual disease assessment or educational purposes. Two patients were excluded for claustrophobia.

To ensure that patients enrolled in the validation study had a normal liver, patients with >5 % liver steatosis, with a liver T2* lower than 15 msec, or with a Fibrotest® > F1 were excluded (as for the pilot study). Therefore, the validation study was conducted in 36 patients with mean age 42 years (range: 19-72 years), 16 women and 20 men, a mean steatosis of 0.72 (range: 0.1-4.33 %, SD: 1), and a T2* value of 21.5 msec (range: 16-33 msec; SD: 3.3).

MR imaging was performed on the same MR system. Localizing sequences, MR spectroscopic sequences, and triple-echo gradient-echo sequences were the same as for the pilot study.

Since we aimed to validate a tri-exponential model as independent from the chosen b values, we used more b-values (n = 16) in combination with less numbers of signal averages keeping acquisition time constant (parameters in Table 1). IVIM MR-DWI data analysis was performed using the same protocol (ROIs, signal normalization) as for the pilot study (Fig. 1).

Fig. 1
figure 1

Axial MR image from the 16 b IVIM DWI sequence used for the validation study. A typical ≈ 1 cm region of interest within the liver parenchyma (avoiding extra-hepatic fat, large hepatic vessels and bile ducts) used for signal measurement is shown

Statistical analysis

The estimation of diffusion parameters and their standard deviations was carried out using a nonlinear least squares regression model. A robust variance estimator was used to take into account the cluster-correlated data (i.e., several measurements per patient, since data were not averaged) and heteroscedasticity (i.e., unequal variances) [28]. Three models were assessed: single-, bi-, and tri-exponential decay. The initial values of diffusion parameters for each model were obtained by “exponential feathering”. A Wald test was used to test the hypothesis that diffusion parameters were different from zero. The assumption of normality of residuals (part of model adequacy) was checked using tests based on skewness and kurtosis. Models were compared via two strategies: using the extra sum-of-squares test [29] and using information criteria. For the latter strategy, we calculated the Akaike information criterion (AIC), the second-order Akaike information criterion (AICc), delta AIC (instead of AICc because AIC was almost equal to AICc in our study), and relative likelihood as suggested by Anderson [30]. The best fitting exponential model was selected based on the criteria above. All analyses were performed using Stata software version 12 (Stata corporation, College Station, TX, USA). A P-value below .05 was considered significant.

Results

Pilot study

Normalized signal values and the averaged curve for the pilot study are shown in Fig. 2. Diffusion coefficients for mono-, bi-, and tri-exponential models determined from nonlinear regression are reported in Table 2. Using the extra sum-of-squares test, the bi-exponential model provided a better fit than the mono-exponential model (P < .001) and the tri-exponential model provided a better fit than the bi-exponential model (P < .001) (Table 3). Using information criteria, the tri-exponential model provided a better fit than the bi-exponential model, which in turn provided a better fit than the mono-exponential model (Table 4).

Fig. 2
figure 2

Individual normalized signal values at each b value (small squares) and fitting curve (red curve) derived from an averaged data set obtained from all the individual data points at each b-value for the pilot study (11 b values). Please note that it is only an illustration since our methodology did not average all patient data before fitting, but took into account all individual data for fitting

Table 2 Results of the nonlinear regression applied in the pilot study using a mono-, bi-, and tri-exponential model
Table 3 Comparison in the pilot study of mono-, bi-, and tri-exponential models using extra sum-of-squares tests (F tests)
Table 4 Comparison in the pilot study of mono-, bi-, and tri-exponential models using information criteria

Validation study

Diffusion coefficients for each model determined in the validation study are reported in Table 5. Mono-, bi-, and tri-exponential regression curves are shown in Fig. 3. Comparison of the three models using the extra sum-of-squares test (Table 6) and the information criteria (Table 7) showed the same results as for the pilot study. The tri-exponential model provided a better fit than the bi-exponential model, which in turn provided a better fit than the mono-exponential model. The contribution of each diffusion compartment to the total signal is reported in Table 8.

Table 5 Results of the nolinear regression applied in the validation study using a mono-, bi-, and tri-exponential model
Fig. 3
figure 3

Bi- (red curve) and tri-exponential (blue curve) modelling of the averaged IVIM signal obtained from one patient of the validation study (16 b values). This illustrates that tri-exponential modelling provided a better fit to the IVIM signal

Table 6 Comparison in the validation study of mono-, bi-, and tri-exponential models using extra sum-of-squares tests (F tests)
Table 7 Comparison in the validation study of mono-, bi-, and tri-exponential models using information criteria
Table 8 Contribution of each diffusion compartment in the DWI signal according to the values of b (validation study)

Discussion

We found that a tri-exponential model provided a better fit for DWI signal decay of the normal liver than did the classical bi-exponential model, initially described by Le Bihan [4, 31]. The original IVIM model considered two different compartments: a slow diffusion compartment related to either intra-cellular or extra-cellular pure molecular diffusion (represented by D), and a rapid diffusion compartment related to microperfusion (represented by D*). In our study, we demonstrated that a third diffusion compartment could exist. We believe that this finding is not an artefact since 1) we made no specific assumption regarding this third compartment and 2) the results of the pilot study were confirmed in the validation study using a different population of patients, as well as a different number and a different distribution of the b values. The precise origin of the third compartment is beyond the scope of this study, but we can make two observations: First, according to IVIM theory [1, 2, 4], the fast component of diffusion is linked to perfusion by the equation \( Dfast=\frac{l\cdot v}{6} \) ,where l is the mean length of the capillary segment and v is the mean velocity of capillary blood. With a ≈ 400*10-3 mm2/s diffusion coefficient, this compartment clearly contains very rapid flowing spins. Second, diffusion is characterized by a diffusion sphere whose radius is defined by R = (6Dt)1/2 as the mean squared displacement of a water molecule with diffusion coefficient D from the centre of the sphere in time t. For D = 400 × 10-3 s/mm2 and t ≈ 50 msec (i.e., diffusion time), the calculated R is ≈ 350 μm. This radius is considerably larger than the diameter of terminal arterioles (≈22 μm), portal venules (≈53 μm), or hepatic venules (≈33 μm) in the hepatic lobule [32]. Thus, flowing spins of the third compartment are probably located in larger vessels (arterioles and/or portal venules and/or hepatic venules), which exhibit IVIM characteristics as long as they are randomly oriented and so numerous that the spins lose their phase memory during the measurement period [33]. The second compartment with a diffusion coefficient (≈25 × 10-3 mm2/s) that is ten times greater than the diffusion coefficient of free water (2.5 × 10-3 mm2/s at 40 °C) probably reflects microperfusion effects. Such an admixture of various perfusion components in liver parenchyma has already been proposed and referred to as the multiple-perfusion-components theory [17].

Interestingly, according to the literature regarding bi-exponential IVIM DWI of the normal liver, there is a tendency for D* to increase when the number of very low (<20 s/mm2) b values increases. For one very low b value (i.e., b = 0 s/mm2), D* was reported as being between 27-52 × 10-3 mm2/s [7, 9, 11, 14, 15] while it was between 60-100 × 10-3 mm2/s for two very low b values [8, 10], and between 75-110 × 10-3 mm2/s for three very low b values [2, 6, 12, 13]. The D* value in our series (121 × 10-3 mm2/s), calculated using four very low b values, is in keeping with these results. Interestingly, in the study by Delattre et al. [8], D* of the liver was calculated from the same acquisition (13b IVIM sequence) using either 13 b values (D* = 100.3 × 10-3 mm2/s from b = 0, 15, 30, 45, 60, 75, 90, 105, 120, 250, 350, 450, 550 s/mm2) or only 9 b values (D* = 75.6 × 10-3 mm2/s from b = 0, 30, 60, 75, 90, 120, 250, 450, 550 s/mm2). Again, the use of an additional very low b value (b =15 s/mm2) resulted in a greater D*, whereas D did not differ (1.53 × 10-3 mm2/s using 13 b versus 1.54 × 10-3 mm2/s using 9 b values). This tendency for D* to increase when the number of very low b values increases reflects the contamination of perfusion-related diffusion (derived from the standard bi-exponential IVIM model) by the third compartment, which contributes to the IVIM signal only for b values within the 0-15 s/mm2 range (Table 8).

Hayashi et al., published two papers in which they used a tri-exponential model to fit the diffusion signal in cirrhosis [11] and steatosis [34]. Since they used higher b values (i.e., until 1500s/mm2) and did not sample the diffusion signal decay in the 0-50s/mm2 range, they reported two diffusion components instead of two perfusion components like in our study. Thus, it is not unlikely that four diffusion compartments (or more) may exist in the liver.

The principle of averaging several ROI measurements per patient [35, 36], which are in turn averaged for all patients to model the IVIM signal, has been already used to improve the SNR ratio [8, 19]. Our derived methodology may explain why we report much lower SDs for diffusion coefficients than those usually reported in the literature. Yet, these SDs still remained high for the two fastest diffusion compartments. It has been reported that an increased number of b values (i.e., sampling) results in a more precise estimation of the diffusion coefficients [2, 9, 10, 12, 18]. However, to keep within an acceptable acquisition time, we had to reduce the number of signal acquisitions (only one for the 16 b sequence). Despite the use of state-of-the-art gradient hardware, 3 T acquisition, respiratory triggering, parallel imaging, and reduced TE, the SNR still remained low for IVIM DWI of the liver. This is a major cause of difficulties in modelling the fast compartment(s) of diffusion. We notice in Table 8 that for b = 0 s/mm2, each of the first two compartments contributed to only 13 % of the total signal. This proportion falls very quickly when b values increase. If noise is considered constant, the SNR from the two fastest diffusion compartments at b = 0 is half that of the global IVIM signal at b = 800 s/mm2. This very low SNR can at least partly explain why the reliable and precise determination of corresponding diffusion coefficients is extremely challenging.

As mentioned above, the quality of sampling (i.e., the number of b values used) is also a critical point to precisely estimate these coefficients. In our validation study using 16 b values, only the first compartment (S1 signal) contributed to the IVIM signal over the 200-800 s/mm2 range. Over the 15-150 s/mm2 range (9 b values), both the first and second compartment contributed to the IVIM signal while over the 0-10s/mm2 range (3 b values), the three compartments contributed. Therefore, for the third compartment, we have both a low SNR and very low sampling. It was, thus, logical for measurement to be imprecise. For the second compartment, we were able to achieve an adequate number of samples (9 b values in the 15-100 s/mm2 range), but as for D* estimation in the bi-exponential IVIM model, the SNR still has to be improved to obtain reliable and precise results. New IVIM sequences that allow a flexible number of acquisitions for each b value in clinically acceptable acquisition times, when available, should at least partly compensate for the low SNR.

The pooled analysis from different patients with a normal liver was useful to demonstrate the existence of a third compartment, but in clinical practice, the aim is to calculate diffusion parameters at an individual level. For bi-exponential IVIM, a segmented approach, that is to say calculating D then f then D*, has frequently been used in the literature [2, 11, 1315] since simultaneous fitting of all diffusion parameters usually gives unstable results. By using only b values >15 s/mm2, the tri-exponential model can be reduced to a bi-exponential model since the third compartment no longer contributes to the IVIM signal. Then, a segmented approach may be used to model the first and second compartment. The acquisition of only >15 s/mm2 b values would give the opportunity to simplify the tri-exponential model and to increase the number of samples to model the first two compartments. This approach needs to be explored in a future work.

Several limitations of this study must be acknowledged. First, we selected patients with a presumed normal liver, without histological confirmation. However, since liver biopsy in this context was not ethically acceptable, we combined multiple criteria (based on patients’ history, clinical examinations, biological markers, the Fibrotest® ,and the absence of liver steatosis or iron overload as determined by multimodal MRI) to rule out liver disease. Second, the liver and blood have completely different T2 times [2] and f values are strongly influenced by these different T2 times. We did not calculate T2-corrected f values[19], since we could not make sure that the second and third compartment of diffusion corresponded to blood. The use of different TEs between the pilot and the validation study would have allowed us to calculate the differences between the T2 relaxation times of the second and third compartments [6, 19], and would, thus, have indicated whether or not they had the same nature (blood). However, since we aimed to minimize the TE to improve the SNR in this study, TEs were almost similar. Third, we did not consider noise (especially Rician noise) influence in the diffusion signal decay. However, its influence was probably limited since we used relatively low b values (≤800 s/mm2) with the aim to preserve a high SNR. Fourth, our study was designed for the normal liver. The behaviour of the IVIM signal could be different in tumours or maybe in diffuse liver diseases like cirrhosis or steatosis. The adequacy of the tri-exponential model in these settings needs to be explored in further studies. Finally, we did not assess other multi-compartmental models (four compartments or more) given the technical limitations regarding sampling and the SNR of our IVIM sequences.

In conclusion, the tri-exponential model provides a better fit for IVIM signal decay in the liver than the classical bi-exponential model across the 0-800 s/mm2 range. The tri-exponential model accounts for three different compartments: a slow component of diffusion corresponding to classical pure molecular diffusion, a fast diffusion compartment with a ≈ 20 × 10-3 mm2/s diffusion coefficient, and a very fast diffusion compartment with a ≈ 400 × 10-3 mm2/s diffusion coefficient. Due to limited sampling and the SNR of usual IVIM sequences, the study of the fastest compartment is probably unrealistic at an individual level. This third very fast (pseudo) diffusion component will be relevant for liver IVIM analysis when more sophisticated IVIM sequences become available.