Introduction

An imaging-based liver function test capable of determining liver function on a regional level and allowing prediction of both postoperative liver function and the risk of postoperative liver failure would be a powerful tool for hepatologists and liver surgeons [18]. Liver resections for hepatic malignancies become more radical to achieve a curative therapy for an increasing number of patients [9]. These more radical therapies lead to a higher risk of postoperative liver failure. If volumetry and global liver function tests like indocyanine green (ICG) or LiMAx show a high risk of postoperative liver failure, portal vein embolization (PVE) is an established method to increase future remnant liver (FRL) volume and decrease the incidence of postoperative liver failure, allowing more patients with an otherwise small FRL volume to benefit from partial resection [914]. After PVE, however, liver function is no longer distributed equally over the liver tissue [5]. Additionally, liver function may be compromised by e.g. preoperative chemotherapy or chronic cholestasis. An imaging-based liver function would be the ideal tool to estimate the FRL function, to monitor the success of PVE, to schedule the time of surgery, and to identify patients at an increased risk for postoperative liver failure.

Scintigraphic methods—mostly using 99mTc-IDA (iminodiacetate) analogues like mebrofenin as tracers—are currently the only imaging-based liver function tests used to assess liver uptake and biliary excretion of tracers in clinical practice [1517]. Dynamic 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) or single photon emission computed tomography (SPECT) can be used to estimate total liver function and to predict postoperative remnant liver function of residual liver volume [6, 18]. Furthermore, HBS can be used to monitor the increase in function of the remnant liver following preoperative PVE and correlates with the ICG clearance test [2, 5, 6, 18, 19]. Problems with scintigraphic methods are low temporal and spatial resolution and the overlap of left and right sectors because of planar acquisition [17].

Gd-EOB-DTPA (gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid) is a magnetic resonance imaging (MRI) contrast agent that shares several pharmacokinetic properties with IDA—both are taken up by hepatocytes through the organic anionic transport system (OATS) and are excreted into the bile by glutathione S-transferase. Therefore, Gd-EOB-enhanced MRI is being developed as an alternative to the established scintigraphic methods but is not yet available for routine clinical use [3, 4, 20, 21]. Potential advantages include that there is no need for a radioactive tracer and that the examination can be integrated into routine preoperative workflow. Moreover, state-of-the-art MRI sequences provide superior temporal and spatial resolution compared to SPECT-CT. By increasing the flip angle, the signal ratio of Gd-EOB to background can be increased substantially to enable an acquisition quite similar to HBS [22]. However, as Gd-EOB-DTPA is also eliminated by renal excretion (approx. 50 %), there is the need for an investigation to quantitatively compare the hepatic uptake measured by HBS and EOB-MRI in normal and functionally impaired liver tissue to ensure equal ability of EOB-MRI with regards to liver function testing before starting further efforts to develop a sophisticated EOB-MRI liver function quantification tool [23]. This requires prospective testing with both modalities in subjects with different liver function in the left and right lobe to allow for an intraindividual analysis of uptake differences reliably quantifiable by HBS as the reference method and by EOB-MRI.

Therefore the purpose of this study was to compare static Gd-EOB-DTPA-enhanced MRI with 99mTc-mebrofenin HBS as imaging-based liver function tests. PVE served as a model for heterogeneous distribution of liver function where the separate right and left liver lobe function was evaluated.

Materials and methods

Patients treated with right PVE between July 2010 and March 2014 and underwent 99mTc-mebrofenin HBS and Gd-EOB-enhanced MRI within 24 h were retrospectively enrolled in our study. The study complied with the Declaration of Helsinki. The study protocol was approved by the institutional review board.

99mTc-mebrofenin HBS

All examinations were performed on a SPECT/CT system (Symbia T6, Siemens Healthcare, Erlangen, Germany). An unenhanced low-dose CT of the upper abdomen was obtained for planning. The CT images were evaluated to determine the individual scan fielding z-axis and the right anterior oblique rotation angle of the detector according to the line separating the left and right liver lobe (reference structures: middle hepatic vein, gall bladder, inferior vena cava). After intravenous administration of 185 MBq 99mTc-mebrofenin (Bridatec, GE Healthcare), dynamic image acquisition was performed with the liver and heart in the field of view (FOV) using a single low energy high resolution collimator (energy window, 130–150 keV; matrix, 64 × 64). Dynamic acquisition was performed over 45 min at 30 s per frame (90 frames).

Regions of interest (ROIs) were drawn around right liver lobe and left liver lobe and heart/large vessels within the mediastinum as blood pool. Liver ROIs were drawn manually by one experienced radiologist and nuclear medicine physician with 10 years of experience. The parameters T max and T 1/2 were obtained from the time–activity curve of the right and left liver lobe. Liver uptake of mebrofenin was calculated as the increase in blood-pool-corrected 99mTc-mebrofenin uptake per minute from 150 to 350 s after injection (total duration of 200 s) to ensure that the calculations are made during a phase of homogeneous distribution of the agent in the blood pool, before biliary excretion takes place, as described by Bennink et al. [6, 18, 24]. The percentage function of the right and left liver lobe was calculated by multiplying mebrofenin liver uptake U of the right or left liver lobe by the appropriate lobar volume V from prior AC-CT, similar to the hepatic uptake index (HUI) in MRI, and then setting these values in proportion with the following formula (exemplarily for RLL):

$$ {U}_{\mathrm{RLL}} \times {V}_{\mathrm{RLL}}/\left[{U}_{\mathrm{RLL}} \times {V}_{\mathrm{RLL}} + {U}_{\mathrm{LLL}} \times {V}_{\mathrm{LLL}}\right]. $$

MRI

Gd-EOB-DTPA-enhanced MRI was performed within 24 h before or after HBS. MRI was acquired on a 1.5-T-device (Avanto, Siemens, Erlangen, Germany) using and an eight-channel body phased-array coil. A standard volume interpolated breath-hold examination sequence (VIBE) in the axial plane with a TR of 4.26 ms, a TE of 1.87 ms, a flip angle (FA) of 10°, a slice thickness 3 mm and a matrix size of 256 × 127 was acquired covering the entire liver with 60–72 slices and an adjusted field of view (FOV) of 255–300 × 340–400 mm. A dose of 0.1 mL Gd-EOB-DTPA (0.25 mmol/mL) per kg body weight was then manually injected in an anterior cubital vein, followed by a saline flush of 20 mL. After 20 min in the hepatocyte phase, the standard VIBE sequence was repeated.

Images were evaluated with OsiriX version 5.8 (Pixmeo SARL, Bernex, Switzerland). MRI was evaluated by one experienced radiologist and nuclear medicine physician with 10 years of experience. Five representative circular regions of interest (ROIs) with a fixed diameter of 3 cm were placed on the images in both the left (territory of the left nonembolized portal vein) and the right liver lobe (territory of the embolized right portal vein) and the spleen, avoiding large vessels and liver lesions such as cysts or tumours. ROIs were placed in different parts of the liver lobe to minimize gravity and magnetic heterogeneity effects. Relative enhancement was calculated by subtracting the signal intensity (SI) of the unenhanced images from the SI in the hepatobiliary phase and dividing the difference by the SI of the unenhanced images [25]. Volume (V) was measured manually delineating both the RLL and the LLL, virtually separated by the planned resection line. Tumour masses, large vessels or bile ducts and other liver lesions were excluded from the volume. As introduced by Yamada et al. [7], the HUI for RLL and LLL was calculated according to the following formula: V Liver [(SILiver/SISpleen) − 1], where V L and SIL were taken either for RLL or for LLL. The percentage function of the right and left liver lobe was calculated according to the proportions of HUI for RLL and LLL.

Statistical analysis

Statistical analysis was performed using PASW Statistics 22 (IBM, Armonk, New York). The t test and Wilcoxon signed-rank test for paired values were applied to compare features of RLL and LLL. Correlations were tested by calculating Spearman Rho correlation coefficients. A two-sided test was used for assessing statistical significance assuming significance at a p value of less than 0.05. Unless otherwise indicated, all quantitative data are expressed as mean ± standard deviation.

Results

Patient characteristics

During the interval from July 2010 and March 2014, 14 patients (five women, nine men) were included in our study. Mean patient age was 59.2 ± 10.3 years (range 45–83). The indication for HBS and MRI was planned extended liver resection after PVE in all cases. Reasons for resection were colorectal liver metastases in four patients and cholangiocarcinoma in ten patients. Average time from PVE to HBS and MRI was 15.2 ± 2.1 days. Total serum bilirubin at the time of PVE was 1.4 ± 1.23 mg/dL (range, 0.4–3.9; normal, <1.2 mg/dL) and was elevated in two patients because of cholestasis. No patient had clinical or morphologic signs of cirrhosis or other diffuse liver diseases. Serum creatinine at the time of PVE was 0.77 ± 0.18 mg/dL (range, 0.52–1.1; normal, <1.2 mg/dL).

Results of 99mTc-mebrofenin HBS

Average T max was 979.3 ± 537.8 s for RLL and 848.6 ± 295.7 s for LLL (Table 1). Average T 1/2 was 2,244.3 ± 695.4 s for RLL and 2,011.6 ± 626 s for LLL. Mebrofenin uptake in %/min was 10.54 ± 4.26 %/min for RLL and 13.76 ± 3.65 %/min for LLL. The difference between RLL and LLL for T max and T 1/2 was not statistically significant (p = 0.209 and 0.070, respectively). However, mebrofenin uptake was significantly higher for LLL than for RLL (p = 0.001). The average share of total function was 49.02 ± 12.68 % for RLL and 50.98 ± 12.68 % for LLL.

Table 1 Parameters derived from 99mTc-mebrofenin hepatobiliary scintigraphy and Gd-EOB-enhanced MRI as well as volumes for right liver lobe (RLL) and left liver lobe (LLL)

Results of Gd-EOB-enhanced MRI

The average size of the RLL was 989.7 ± 203.6 cm3 and the average size of the LLL was 753.9 ± 230.9 cm3. Average unenhanced SI for RLL was 285.4 ± 61.9 and 266.0 ± 78.5 for LLL. Average SI in the hepatobiliary phase was 441.1 ± 138.3 for RLL, 446.2 ± 133.7 for LLL and 271 ± 120.1 for the spleen. Average RE was 0.49 ± 0.17 for RLL and 0.66 ± 0.22 for LLL. Average HUI was 778.7 ± 674.4 for RLL and 547.6 ± 352.1 for LLL. RE for LLL was significantly higher than for RLL (p > 0.001). HUI did not differ statistically significantly between RLL and LLL (p = 0.066). The average share of total function as indicated by HUI was 57.43 ± 21.23 % for RLL and 42.57 ± 21.23 % for LLL.

Correlation of scintigraphy and MRI

Both T max and T 1/2 showed negative correlations with RE and HUI, but none of these were statistically significant. Mebrofenin uptake showed statistically significant correlations with HUI and RE for both liver lobes (Figs. 1 and 2). Strong correlation with HUI was calculated for RLL (r 2 = 0.802, p = 0.001) and with RE for LLL (r 2 = 0.704, p = 0.005); furthermore, moderate correlation with HUI for LLL (r 2 = 0.560, p = 0.037) and RE for RLL (r 2 = 0.620, p = 0.018) was revealed. Correlating the percentage share of RLL function derived from MRI (from the proportion of HUI) with the percentage share of RLL function derived from mebrofenin uptake revealed a strong correlation (r 2 = 0.775), which was statistically significant (p = 0.002) (Fig. 3).

Fig. 1
figure 1

67-year-old patient with colorectal liver metastasis scheduled for extended right liver resection; portal vein embolization was performed 2 weeks before. a Unenhanced and b Gd-EOB-enhanced MRI (T1 VIBE). c 99mTc-mebrofenin hepatobiliary scintigraphy after 10 min. d Liver uptake time–activity curve for RLL (red) and LLL (green)

Fig. 2
figure 2

Scatter plots show the correlation of relative enhancement or hepatic uptake index with mebrofenin uptake (%/min) for right and left liver lobe. Lines of best fit and 95 % confidence intervals are shown as straight and curved lines, respectively

Fig. 3
figure 3

Correlation of percentage RLL function as calculated from Gd-EOB-enhanced MRI using the proportion of HUI of RLL and LLL and percentage RLL function as calculated by mebrofenin uptake in 99mTc-mebrofenin hepatobiliary scintigraphy. Line of best fit and 95 % confidence intervals are shown as straight and curved lines, respectively

Discussion

We compared static Gd-EOB-DTPA-enhanced MRI with 99mTc-mebrofenin HBS as imaging-based liver function tests for the separate evaluation of right and left liver lobe function following PVE as a model for heterogeneous distribution of liver function in 14 patients.

T max and T 1/2 derived from scintigraphy correlated negatively with HUI and RE, but this correlation was not statistically significant. This can be explained by the fact that they are too dependent on blood flow parameters and biliary congestion. Since mebrofenin and Gd-EOB are both taken up into hepatocytes through the OATS, which plays a key role in liver function, mebrofenin uptake and RE from Gd-EOB-enhanced MRI show strong correlation. The HUI is a measure of relative enhancement corrected for blood flow and liver volume, which explains the similar strength of correlation with mebrofenin uptake. Multiplying lobar mebrofenin uptake with lobar volume—similar to HUI—enables separate determination of left and right liver function from scintigraphy.

Imaging-based liver function tests represent a major improvement on global liver function tests such as the LiMAx or ICG test. The latter tests are unreliable in patients with regional dysfunction or heterogeneous distribution of liver function and are therefore unable to correctly predict postoperative liver function after PVE. Using 99mTc-mebrofenin SPECT combined with dynamic planar acquisition, de Graaf et al. showed that the increase in FRL function after PVE is higher than the increase in FRL volume, underlining the need for an image-based liver function test [5]. In recent years, increasing evidence has emerged to suggest that Gd-EOB-enhanced MRI can be used to determine liver function [3, 7, 21, 2634]. However, there still exists no consensus on which parameter derived from MRI is the most suitable. The parameters that have been proposed include relative enhancement, HUI, absolute uptake determined by T1-mapping, hepatic extraction fraction and input relative blood flow [4, 7, 33, 34]. Relative enhancement and hepatic uptake index are two parameters that can be derived from virtually any Gd-EOB-enhanced MRI. Both have been shown to correlate with results of the ICG test and distinguish between normal and elevated MELD scores, which is why we chose these two parameters for our study [3335].

When 99mTc-mebrofenin HBS is performed, the two most commonly used parameters to determine liver function are mebrofenin clearance (MCR) and uptake (MUR) rate. Both provide similar results relative to clearance rate expressed as millilitres per minute. The MUR is used in all clinical application to date [24]. Functional estimation with 99mTc-mebrofenin HBS is sufficient to predict postoperative outcome more accurately than by using liver volumetry [2]. By combining dynamic planar imaging and static three-dimensional imaging with SPECT, de Graaf et al. were able to visualize the functional increase per millilitre liver volume in the remnant liver following preoperative PVE [5]. This functional gain was also shown with Gd-EOB-enhanced MRI [8]. We did not use SPECT acquisition because our primary goal was the separation of right and left liver function, which can be achieved by rotating the detector to a right anterior oblique position determined by prior CT [36].

Gd-EOB-enhanced MRI has several advantages over 99mTc-labelled mebrofenin scintigraphy. First, it does not rely on a radioactive tracer, which makes it easier to conduct and avoids radiation exposure for the patient. Second, it easily integrates into preoperative clinical workflow. Gd-EOB-enhanced MRI is already conducted in an increasing number of patients scheduled for liver surgery since it not only provides morphological information but also allows highly sensitive tumour detection and assessment of topography with the intrahepatic vessels [37, 38]. Gd-EOB-enhanced MRI yields all the information required for preoperative planning with the functional information that can be derived from the data sets providing an additional bonus. Third, MRI has a superior temporal and spatial resolution. When novel sequences such as CAIPIRINHA-Dixon-TWIST are used, up to 14 high spatial resolution three-dimensional data sets (1.2 × 1.2 × 3 mm × 21 slices) can be acquired within 29 s [39]. This will enable precise calculation of hepatic extraction fraction from Gd-EOB-enhanced MRI in the near future.

Our study has several limitations. First, the study design was retrospective and the patient number was small, which can be explained by the still small number of patients undergoing 99mTc-mebrofenin HBS. Second, we were not able to correlate Gd-EOB uptake with mebrofenin uptake as MRI was only conducted at two time points (unenhanced and 20 min after contrast injection). A dynamic MRI study with high temporal resolution is needed to calculate Gd-EOB uptake and extraction fraction. Another weakness is that the reliability of both methods may be reduced in patients with elevated bilirubin; two patients had elevated bilirubin because of obstruction. It is assumed that Gd-EOB-DTPA and mebrofenin compete with bilirubin for uptake, similar to ICG. Last, correlation with postoperative liver function as a “gold standard” would be highly desirable. This is, however, difficult to achieve as a perfect liver function test does not exist.

Although the correlation of HUI and mebrofenin uptake was significant, the average functional share of right and left liver lobe differed as average RLL function determined by MRI was 49.02 ± 12.68 % versus 57.43 ± 21.23 % by HBS. A possible explanation could be the so-called attenuation bias resulting from the fact that the right liver lobe generally has a larger diameter than the left liver lobe, even when the gamma camera is rotated into right-anterior oblique orientation based on the individual patient’s line separating the left and right liver lobe. This drawback can be overcome by simultaneous data acquisition in the anterior and posterior projection using a dual-head gamma camera and calculating geometric mean activity. The posterior view, however, is hampered by the unequal attenuation of tissues between the liver and the collimator, which is caused by the spine. Although this can be partially overcome by adding an additional fast SPECT acquisition during the dynamic phase [5], MRI should theoretically yield more accurate functional results because the three-dimensional data set is not subject to an attenuation bias and allows more exact separation of left and right liver lobe. This has to be verified in additional studies.

In conclusion our results suggest that Gd-EOB-enhanced MRI and 99mTc-mebrofenin HBS may equally be used to separately determine right and left liver lobe function after PVE.