Abstract
The aim of the present study was to investigate whether anodal transcranial direct-current stimulation (tDCS) of lower-limb primary motor cortex (M1) could increase cortical excitability when reference electrodes were placed at extracephalic positions. Ten healthy volunteers participated in this study. Anodal electrodes were placed over the left lower-limb M1, whereas reference electrodes were placed on the contralateral forehead (cephalic condition) or contralateral upper arm (extracephalic condition). Motor evoked potentials (MEPs) were recorded as a measure of cortical excitability before and after tDCS (2 mA, 10 minutes). Compared with a sham condition, MEPs significantly increased for both cephalic and extracephalic conditions, and this increase was maintained for approximately 60 minutes after stimulation. No side effects were reported. We conclude that tDCS over lower-limb M1 in conjunction with extracephalic reference electrodes can increase cortical excitability without any side effects.
This work was supported by KAKENHI (24680061) to S.T.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
References
Nitsche, M.A., Paulus, W.: Excitability changes induced in the human motor cortex by weak transcranial direct current stimulation. J. Physiol. 527, 633–639 (2000)
Tanaka, S., Watanabe, K.: Transcranial direct current stimulation–a new tool for human cognitive neuroscience. Brain Nerve 61, 53–64 (2009)
Vandermeeren, Y., Jamart, J., Ossemann, M.: Effect of tDCS with an extracephalic reference electrode on cardio-respiratory and autonomic functions. BMC Neurosci. 11, 38 (2010)
Moliadze, V., Antal, A., Paulus, W.: Electrode-distance dependent after-effects of transcranial direct and random noise stimulation with extracephalic reference electrodes. Clin. Neurophysiol. 121, 2165–2171 (2010)
Jeffery, D.T., Norton, J.A., Roy, F.D., Gorassini, M.A.: Effects of transcranial direct current stimulation on the excitability of the leg motor cortex. Exp. Brain Res. 182, 281–287 (2007)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Tatemoto, T., Yamaguchi, T., Otaka, Y., Kondo, K., Tanaka, S. (2013). Anodal Transcranial Direct Current Stimulation over the Lower Limb Motor Cortex Increases the Cortical Excitability with Extracephalic Reference Electrodes. In: Pons, J., Torricelli, D., Pajaro, M. (eds) Converging Clinical and Engineering Research on Neurorehabilitation. Biosystems & Biorobotics, vol 1. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-34546-3_135
Download citation
DOI: https://doi.org/10.1007/978-3-642-34546-3_135
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-34545-6
Online ISBN: 978-3-642-34546-3
eBook Packages: EngineeringEngineering (R0)