Patient treatment setup accuracy for cranial radiosurgery (SRS) is dependent on a number of parameters; including localization and immobilization. In this study we carried out a quantitative analysis of the reliability of a radiosurgery immobilization mask system in maintaining patient position during SRS treatment sessions. Patients were fitted with a thermoplastic mask and a customized pillow designed for SRS. TomoTherapy MVCT, using 1 mm slice thickness, was carried out and the required shifts, based on bony anatomy, were applied to the patient position prior to radiotherapy. At the completion of the treatment a second MVCT was carried out to determine if any patient movement had taken place. Typical time on the treatment couch varied from 25-60 minutes. A total of 26 patients were analyzed. Some patients received more than one treatment fraction. A total of 38 MVCT measurements were included in this study. The mean absolute shift for the 38 measurements was 0.42 mm (SD=0.29) lateral, 0.75 mm (SD=0.94) longitudinal, and 0.44 mm (SD=0.42) in the vertical direction. Overall, the average vector displacement was 1.18 mm (SD=0.82). The variation in shifts between different patients was significant. Two patients had a vector shift of greater than 3.0 mm; largely due to a longitudinal displacement. Based on these results a margin of approximately 1 mm is sufficient for patient lateral and vertical motion but up to a 2 mm margin may be needed for longitudinal motion. Hence a PRV and PTV of 3 mm is required to account for patient position uncertainty. Care in the initial molding of the mask, and a customized pillow, may be key in ensuring minimal patient motion during cranial SRS.
Access provided by Autonomous University of Puebla. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Bichay, T.J., Ebrom, P. (2013). A Quantitative Analysis of the Reliability of Aquaplast Mask Immobilization for Cranial Radiosurgery With TomoTherapy. In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_504
Download citation
DOI: https://doi.org/10.1007/978-3-642-29305-4_504
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-29304-7
Online ISBN: 978-3-642-29305-4
eBook Packages: EngineeringEngineering (R0)