Keywords

These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

1 Introduction

Grazing-incidence spectrometers with classical concave gratings for a wavelength range λ ~ 20–300 Å are astigmatic. This entails a drastic lowering in the irradiance of spectral lines and the loss of spatial resolution. Using focusing normal-incidence MMs in combination with varied line-space (VLS) diffraction gratings (DGs) makes it possible to remedy these defects.

Cornu [1] realized that monotonic variations in line spacing modified the curvature of the diffracted wavefronts and the spectral (horizontal) focal curve. Hettrick and Bowyer [2] proposed a way to obtain a stigmatic spectral image in the XUV by sending a converging homocentric beam onto a VLS DG whose local line density has to obey the local grating equation to bring the diffracted rays in the principal plane to a common focus. However, in this case, the spectral image is stigmatic at only one wavelength (Fig. 58.1).

Fig. 58.1
figure 1

Cancellation of astigmatism at one wavelength (λ 1) in the incidence of a converging beam on a plane VLS grating (φ 0 and ψ 0 are the grazing angles of the central rays of the incident and diffracted beams, and m is the order of diffraction)

The line density p(w) of a VLS grating is conveniently expressed as

$$p(w) = p_{0} + p_{1} w + p_{2} w^{2} + p_{3} w^{3} + \cdots .$$
(58.1)

Factor p 1 modifies the spectral curve and p 2 and p 3 remove meridional coma and spherical aberration. In the approach of [2], p 0 and φ 0 are free parameters.

2 Spectrometer Design

Let a slightly astigmatic beam be incident on a plane VLS grating (Fig. 58.2). Let L 1 be the distance of the vertical focus of the incident beam from the grating center and L 2 be that of the horizontal one (L 1 > L 2). Then, it is possible to cancel astigmatism at two wavelengths, λ 1 and λ 2, at a sacrifice of one free parameter (either p 0 or φ 0). The slightly astigmatic beam incident on the grating is produced by a near normal-incidence MM, which images a point source. The sequence of steps is as follows: we define the spectral range, and then determine λ 1 and λ 2 to minimize the defocusing in the range. If we define φ 0, then \(p_{0} = \sqrt {(L_{1} /L_{2} - 1)(\sin^{2} \varphi_{0} )/\lambda_{1} \lambda_{2} }\). If, alternatively, we define p 0, then \(\varphi_{0} = \arcsin (mp_{0} \sqrt {\lambda_{1} \lambda_{2} } /\sqrt {L_{1} /L_{2} - 1} )\). The grating parameters p i result from  (58.2) after Taylor series decomposition:

Fig. 58.2
figure 2

Cancellation of astigmatism simultaneously at two wavelengths, λ 1 and λ 2

$$\begin{aligned} mp(w)\lambda_{1,2} & = \cos \left[ {\text{arcctg} \left( {\text{ctg} \varphi_{0} - \frac{w}{{L_{2} \sin \varphi_{0} }}} \right)} \right] - \\ & \quad - \cos \left[ {\text{arcctg} \left( {\text{ctg} \psi_{0}^{1,2} - \frac{w}{{L_{1} \sin \psi_{0}^{1,2} }}} \right)} \right]. \\ \end{aligned}$$
(58.2)

We calculated several 1-m-long spectrometer versions for the 120–300 Å range, with λ 1 = 144 Å, λ 2 = 270 Å, and p 0 = 600 mm−1. For a grating area of 50 × 20 mm, the ray trace images of a point source are all confined to one detector pixel. The plate scales are about 5 Å/mm and, in view of the detector pixel size of 13 μm, typical practical resolution is expected at ~(0.05–0.07) Å throughout the range. The spectrometer may be equipped with a narrowband periodic multilayer mirror or a broadband aperiodic one. In the latter case, the operating range may span an octave in wavelength or more. In the instrument described below, the MM was mounted at an angle of incidence of 7.59° and the VLS grating was mounted at a grazing angle of 6.44°.

3 Spectrometer Implementation

The spectrometer layout is shown in Fig. 58.3. The XUV source was the plasma of a plane LiF target irradiated by a 1.06 μm, 0.5 J, 10 ns laser pulse. For a test, we took an aperiodic MM spanning a range of at least 125–250 Å [3].

Fig. 58.3
figure 3

Spectrometer elements accommodated on a 1.1-m-long base plate. VLS grating (top of drawing: tungsten VLS grating made by e-beam lithography)

The VLS grating (p 0 = 600 mm−1, p 1 = 2.32 mm−2) was fabricated by e-beam lithography (EBL) followed by inductively coupled plasma (ICP) etching. A 100 nm tungsten film was deposited on a glass substrate, which was next spin-coated with the positive-tone e-beam resist PMMA A4 (Microchem, 5000 rpm, 90 s). It was then exposed to EBL (beam energy 50 keV, current 15.5 nA, write field 600 × 600 μm, dwell time 0.14 ms). The resist was developed in MIBK:IPA (1:3) for 120 s and IPA for 60 s. Finally, the structure was formed with SF6 ICP etching followed by O2 plasma cleaning.

Due to its high light-gathering power, the spectrometer records the spectrum in one 0.5 J laser shot. The portion shown in Fig. 58.4 contains the lines of Li III and F V–F VII. The closest first-order lines resolved with a safety margin are the 163.138 Å line of F VI and the {163.456, 0.501, 0.558, 0.596 Å} unresolved line array of F V, yielding a conservative figure λ/δλ ~ 510. The line half-widths typically correspond to four detector pixels (52 μm). In view of the plate scale (5.5 Å/mm at 125 Å, 6.3 Å/mm at 200 Å), this corresponds to λ/δλ ~ 450 and 600, respectively. The strongest line arises from the 3d → 2p (127.653 Å, 127.796 Å) transitions in F VII, which saturates the CCD detector pixels corresponding to the near-surface portion of the space-resolved spectral image and broadens the apparent linewidth. Its second order is much weaker and is safely resolved, testifying to a resolving power of ~900.

Fig. 58.4
figure 4

Single-shot first-order stigmatic spectrum of an LiF target excited by a 0.5 J pulse. Asterisks indicate unresolved line arrays. Entrance slit width: 30 μm