Abstract
Novel implants based on metallic alloys (stainless steel 316 LVM, Ti6Al4V ELI and Ti6Al7Nb alloys) prepared by self-developed method of surface modification are presented in this study. Implants were coated with biodegradable and bioresorbable layer of poly(glycolide-co-caprolactone). Next, half of the perpetrated specimens was subjected to radiation sterilization. After that, samples were divided in to two groups: I - initial state (samples with sterilized “S” and nonsterilized polymer “NS”; II - samples with sterilized “S90” and non-sterilized polymer coating “NS90” after 90 days of exposure to artificial urine. As a result of the conducted research, it was found that after long-term exposure the polymer degradation was even and inconsiderable. However, reduction of adhesion and finally, retraction of the coatings on the titanium alloys has been observed. Moreover, the influence of sterilization process on the kinetics of metallic ion release to corrosion environment for all metallic biomaterials has been observed.
Access provided by CONRICYT-eBooks. Download to read the full chapter text
Chapter PDF
Similar content being viewed by others
Keywords
References
Borkowski A.: Urologia: Podręcznik dla studentów medycyny. PZWL, Warszawa (2008)
Jacobse S.M., Strickler D.J. Mobley H.L., Shirtliff M.E.: Complicated catheter–assiociated urinary tract infections due to Escherichia coli and Proteus mirabilis. Clin Microbil Rev 21(1), 26–59 (2008)
Shaw G.L., Choong S.K., Fry C.: Ecrustation of biomaterials in the urinary tract. Urol Res 33(1), 17–22 (2005)
Ostrowska K., Strzelczyk A., Różalski A., Strączek P.: Biofilm bakteryjny jako przyczyna zakażeń układu moczowego — mikroorganizmy patogenne, metody prewencji i eradykacji. Postepy HigMed Dosw 67, 1027–1033 (2013)
Klimek L., Różański W., Jabłonowski Z., Sosnowski M., Kliś R.: Obserwacje zmian mikroskopowych cewników typu Double J w zależności od czasu utrzymywania ich w drogach moczowych. Inzynieria Biomaterialow 43-44, 36–39 (2005)
Kajzer A., KajzerW., Gołombek K., Knol M., Dzielicki J.,WalkeW.: Corrosion resistance, eis and wettability of the implants made of 316 LVM steel used in chest deformation treatment. Archives of Metallurgy and Materials, 61 2a, 767–770 (2016)
Szewczenko, J.; Marciniak, J.; Kajzer, W.; Kajzer A.: Evaluation of corrosion resistance of titanium alloys used for medical implants. Archives of Metallurgy and Materials. 61 2 695–699 (2016)
M. Bartmański, B. Świeczko-Źurek: Project of hip joint endoprosthesis for an individual patient with materials selection, Advances In Materials Science, 15, 1 (43), 30–36 (2015) Solid State Phenomena Corrosion and Surface Engineering 227 491–494 (2015)
Basiaga M., Paszenda Z., Karasiński P., Kajzer A., Walke W.: Mechanical Properties of Anodically Oxidized cpTi and Ti-6Al-7Nb Alloy Applications of Computational Tools in Biosciences and Medical Engineering. Adv Struct Mater 71. Chapter 8 Springer 123–132 (2015)
Roe D., Karandikar B., Bonn–Savage N., Gibbins B., Roullet J.B.,: Antimicrobial surface functionalization of plastic catheters by silver nanoparticles. J Antimicrob Chemother 61, 869–876 (2008)
Trupti A., Lauserpina C., Shanta M.: Efficacy of a silicone urinary catheter impregnated with chlorhexidine and triclosan against colonization with proteus mirabilis and other uropathogens. Infect Control Hosp Epidemiol 28, 596–598 (2007)
Hachem R., Reitzel R., Borne A., Jiang Y., Tinkey P., Uthamanthil R., Chandra J., Ghannoum M. Raad I.: Novel antiseptic urinary catheters for prevention of urinary tract infections: correlation of in vivo and in vitro test results. Antimicrob Agents Chemother 53, 5145–5149 (2009)
Lee G., Marathe S., Sabbagh S., Crisp J.: Thermo-expandable intra-prostatic stent in the treatment of acute urinary retention in elderly patients with significant comorbidities. Int Urol Nephrol 37, 501–504 (2005)
Opalko F.J., Adria J.H., Khanc S.R.: Heterogeneous nucleation of calcium oxalate trihydrate in artificial urine by constant composition. J Cryst Growth 181, 410–417 (1997)
Szewczenko J., Kajzer W., Grygiel-Pradelok M., Jaworska J., Jelonek K., Nowińska K., Gawliczek M., Libera M., Marcinkowski A., Kasperczyk J.: Corrosion resistance of PLGA-coated biomaterials. Acta of Bioengineering and Biomechanics 19 1 173–179 (2017)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG
About this paper
Cite this paper
Kajzer, W., Jaworska, J., Jelonek, K., Szewczenko, J., Nowińska, K., Kajzer, A. (2018). Efect Of Sterylization And Long-Term Exposure To Artificial Urine On Corrosion Behaviour Of Metallic BiomaterialsWith Poly(Glikolide-Co-Kaprolactone) Coatings. In: Gzik, M., Tkacz, E., Paszenda, Z., Piętka, E. (eds) Innovations in Biomedical Engineering . IBE 2017. Advances in Intelligent Systems and Computing, vol 623 . Springer, Cham. https://doi.org/10.1007/978-3-319-70063-2_41
Download citation
DOI: https://doi.org/10.1007/978-3-319-70063-2_41
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-70062-5
Online ISBN: 978-3-319-70063-2
eBook Packages: EngineeringEngineering (R0)