Abstract
The standardization in photography in plastic surgery is a very important issue and has been exhaustively discussed in the last years. The documentation of images in scientific research must be done in a systemic and standardized way in order to allow its reproducibility [1]. This enables the validation and comparison of techniques as well as the analysis of results maintaining the scientific accuracy. The clinical photograph must always be taken by the same camera, film, lenses, distances, luminosity, and the same position of the patient [2, 3]. The use of a leveled tripod, electronic flash, spotlights, and markers and the standardization of the distance between the feet and the photographic background are very important technical elements [4]. The photographic background must be of gray color or surgical blue (royal blue), nonreflective. The spotlights (two units) are positioned at 45°, and the leveled tripod allows the adequate framework, which allows the stabilization of the image. The photographic incidences (front, right and left oblique, and right and left side) must be standardized (Fig. 9.1).
Access provided by Autonomous University of Puebla. Download chapter PDF
Similar content being viewed by others
1 Introduction
The standardization in photography in plastic surgery is a very important issue and has been exhaustively discussed in the last years. The documentation of images in scientific research must be done in a systemic and standardized way in order to allow its reproducibility [1]. This enables the validation and comparison of techniques as well as the analysis of results maintaining the scientific accuracy. The clinical photograph must always be taken by the same camera, film, lenses, distances, luminosity, and the same position of the patient [2, 3]. The use of a leveled tripod, electronic flash, spotlights, and markers and the standardization of the distance between the feet and the photographic background are very important technical elements [4]. The photographic background must be of gray color or surgical blue (royal blue), nonreflective. The spotlights (two units) are positioned at 45°, and the leveled tripod allows the adequate framework, which allows the stabilization of the image. The photographic incidences (front, right and left oblique, and right and left side) must be standardized (Fig. 9.1).
It is relevant to highlight the importance of preserving the right of privacy of the patient; therefore, the consent form must be solicited before any photographic documentation [4,5,6].
2 Technical Aspects of the Photograph
2.1 Positioning
Aiming at standardizing the distance between the feet and the photographic background, a 1-cm-thick ethylene vinyl acetate (EVA) frame can be used, which keeps the positioning of the patient fixed at 70 cm from the photographic background and the distancing of 30 cm between the feet (Figs. 9.1 and 9.2) [2].
The photographic background made of polyester fabric measuring 1.60 m length by 1.40 m width in blue color is well stretched and fixed to the wall [7]. There is also a care protocol that was developed with the purpose of standardizing and ordering all stages of data collection, aiming at systematizing them [8]. A distance of 1.2–1.8 m for the body and the face is adequate. We suggest a 105 mm lens at a distance of 1.5 m for the face and a 50 mm lens or an equivalent for the documentation of the body (Fig. 9.2) [2].
The patient is guided to stay in anatomic position, keeping the eyes’ horizontality (Frankfurt plan) during the measuring. The photo framework of the mammary region is defined by the crossline gnathion (chin region) on top and by the bottom edge of the navel at the bottom (Fig. 9.3) [1].
Even though the clinical photographs are taken of five different positions (anteroposterior (AP), right and left side, and right and left oblique [1, 9, 10]), a relaxed and a contracted position of the breast can be added. This maneuver is achieved by pushing the hands against the hip, and it allows a more dynamic assessment. In some particular cases, a leaning forward position is useful to demonstrate asymmetry. Several authors strive aiming at standardizing clinical photographs, but variability remains a challenge [1, 2, 10,11,12].
2.2 Lighting
In plastic surgery many lighting ways have been suggested, from flashes of the camera itself to external lights in different configurations [8]. When it comes to a normal and informal picture, we observe a certain asymmetry in lighting; in other words, one of the sides of the body is illuminated differently. Now, when it comes to surgical documentation, there has to be symmetry between the hemibodies, as well as equal illumination of both sides. Thus, we suggest using a pair of umbrellas assembled at the height of the eyes with a 45-degree angulation.
A recurring problem in the lighting of images of the patient is that some details and contours are eliminated of flattened in such a way by the light that they are not visible. The cellulite in the body or certain facial wrinkles are frequently not seen in anterior light (flash) but are extremely apparent in vertical light. In general, skin irregularities are better observed in tangential light. Shapes such as breasts or contours of the body are better seen in slightly shaded light.
Lighting is a topic of extreme importance to preserve the technical accuracy of clinical photograph. Excessive lighting or overexposure can mask furrows, wrinkles, or scars. In the same way, poor lighting or underexposure may cause shades which accentuate folds or scars [4].
2.3 Storing of Images
Technology has evolved quickly. Some decades ago, drawings were used and, next, black and white photography, colored transparencies, and films. In the last 15–20 years, digital images have become the new pattern, and analogic photography became obsolete.
There has also been a change in the way images are stored. Diskettes, magnetic tapes, CDs, DVDs, USB drives, external HDs, and network units gave way to data archiving in the cloud [13]. The advance of technology presents challenges concerning technical work (software incompatibility, hardware, execution problems, scanning, and storing) and security. The lack of a specific legislation and clear rules makes the circulation of images through the Internet a weak point.
3 New Technologies for Breast Measuring
The three-dimensional surface image has gained popularity in plastic and reconstructive surgery worldwide because the two-dimensional pattern lacked in shape and depth [14]. The 3D image is a significant advance in photographic evaluation, because it is able to calculate measures and carry out clinical analyses in x, y, and z coordinates (three-dimensional). This triangulation allows the creation of 3D images [15].
The 3D image was first described in 1994 to diagnose ortho-dental conditions. It was initially used to highlight facial asymmetry and subsequently used to show alterations in the body contour [16, 17].
In breast surgery, the 3D images help in determining the volumes and shapes of the breast, estimate the differences, and allow the projection of results after the surgery [18]. This tool must be used as an auxiliary, and the virtual post-surgery results must not be promises of actual results. Numerous variables may interfere in the final result (age, BMI, ethnicity, height, gender, quality of breast tissue, lactation period, among others) [19].
It is important to observe the limitation of the use of these images, which still bump into cost, quickness and capture of image processing, portability, and special characteristics of the images [19, 20].
The 3D image is a tool which assists the surgeon in his decisions, besides being an important form of marketing. The quick advance of technology will provide a more efficient communication between the doctor and the patient, allowing a more precise and effective instruction.
The ultimate objective is to bring about a more satisfactory result for the patient.
References
Hochman B, Nahas FX, Ferreira LM (2005) Fotografia aplicada na pesquisa clínico-cirúrgica. Acta Cir Bras [Serial Online] 20(Suppl 2):19–25
Dibernardo BE, Adans RL, Krause J, Fiorillo MA, Gherardini G (1998) Photography standards in plastic surgery. Plast Reconstr Surg 102(2):559–568
Parker WL, Czerwinski M, Sinno H et al (2007) Objective interpretation of surgical outcomes: is there a need for standardizing digital images in the plastic surgery literature? Plast Reconstr Surg 120(5):1419–1423
Jakowenko J (2009) Clinical photography. J Telemed Telecare 15(1):7–22
American Society of Plastic Surgeons: Authorization for and Release of medical photographs/slides/and/or video footage in patient consultation resource book (2009) American Society of Plastic Surgeons Arlington Heights
Reed ME, Feingold SG (1988) Ethical consideration. In: Nelson GD, Krause JL (eds) Clinical photography in plastic surgery. Little, Brown, Boston, pp 129–153
Galdino GM, Vogel JE, Vander Kolk CA (2001) Standardizing digital photography: it’s not all in the eye of the beholder. Plast Reconstr Surg 108(5):1334–1344
Riml S, Piontke AT, Larcher L et al (2010) Widespread disregard of photographic documentation standards in plastic surgery: a brief survey. Plast Reconstr Surg 126(5):274e–276e
Westreich M (1997) Anthropomorphic breast measurement: protocol and results in 50 women with aesthetically perfect breast and clinical application. Cosmetic 100(2):468–479
Gherardini G, Matarasso A, Serure AS, Toledo LS, Dibernardo LS (1997) Standardization in photography for body contour surgery and suction-assisted lipectomy. Plast Reconstr Surg 100(1):227–237
Ellenbogen R, Jankauskas S, Collini FJ (1990) Achieving standardized photographs in aesthetic surgery. Plast Reconstr Surg 86(5):955–961
Disaia JP, Ptak JJ, Achauer BM (1998) Digital photography for the plastic surgeon. Plast Reconstr Surg 102(2):569–573
Besser H (2000) Digital longevity. Maxine S Handbook for digital projects: a management tool for preservation and access. Northeast Document Conservation Center Andover, pp 155–166
Da Silveira AC, Daw JL Jr, Kusnoto B, Evans C, Cohen M (2003) Craniofacial applications of three-dimensional laser surface scanning. J Craniofac Surg 14:449–456
Geng J (2011) Structured-light 3D surface imaging: a tutorial. Adv Opt Photon 3:128–160
Tzou CH, Frey M (2011) Evolution of 3D surface imaging systems in facial plastic surgery. Facial Plast Surg Clin North Am 19:591–602, vii
Thalmaan D (1944) Die Stereogrammetrie: ein diagnostisches Hilfsmittel in der Kieferorthopaedie (Stereophotogrammetry: a diagnostic device in orthodontology). University of Zurich, Zurich
Creasman CN, Mordaunt D, Liolios T, Chiu C, Gabriel A, Maxwell GP (2011) Four-dimensional breast imaging, part II: clinical implementation and validation of a computer imaging system for breast augmentation planning. Aesthet Surg J 31:925–938
Chang JB, Small KH, Choi M, Karp NS (2015) Three-dimensional surface imaging in plastic surgery: foundation, practical applications, and beyond. Plast Reconstr Surg 135:1295–1304
Smith DM, Aston SJ, Cutting CB et al (2005) Applications of virtual reality in aesthetic surgery. Plast Reconstr Surg 116(3):898–906
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer International Publishing AG, part of Springer Nature
About this chapter
Cite this chapter
Fraga, M., Colferai, D.R., Sampaio, M. (2019). Photographic Principles of Medical Documentation. In: Urban, C., Rietjens, M., El-Tamer, M., Sacchini, V.S. (eds) Oncoplastic and Reconstructive Breast Surgery. Springer, Cham. https://doi.org/10.1007/978-3-319-62927-8_9
Download citation
DOI: https://doi.org/10.1007/978-3-319-62927-8_9
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-62925-4
Online ISBN: 978-3-319-62927-8
eBook Packages: MedicineMedicine (R0)