Abstract
A simple, rapid, precise, sensitive, and reproducible reverse-phase high-performance liquid chromatography (RP-HPLC) method has been developed for the quantitative analysis of gallic acid in the pharmaceutical dosage form. Chromatographic separation of gallic acid was achieved on Waters Alliance-e 2695, by using Waters X-Terra RP-18 (150 × 4.6 mm, 3.5 μ) column and the mobile phase containing 0.1% formic acid and ACN in the ratio of 70:30% v/v. The flow rate was 1.0 mL/min; detection was carried out by absorption at 275 nm using a photodiode array detector at ambient temperature. The number of theoretical plates and tailing factor for gallic acid was NLT 2000 and should not be more than 2 respectively. Percentage relative standard deviation of peak areas of all measurements is always less than 2.0. The proposed method was validated according to ICH guidelines. The method was found to be simple, economical, suitable, precise, accurate, and robust method for quantitative analysis of gallic acid.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
Keywords
51.1 Introduction
Reverse-phase chromatography or RP-HPLC is a commonly used HPLC technique for the analysis of a wide range of compounds. In this technique, the stationary phase used in nonpolar while the mobile phase is aqueous or moderately polar in nature. Hydrocarbons are used as the stationary phase and water or acetonitrile is used as the mobile phase in this kind of high-performance liquid chromatography (RP-HPLC). Solutes are eluted in decreasing polarity order in RP-HPLC. For RP-HPLC, stationary phases for the silanol group are produced by treating the surface with an organo chloro silane. Non polar hydrocarbon chains in the stationary phase interact with sample molecules to provide a retention mechanism in RP-HPLC.
Gallic acid was determined by Carl Wilhelm Scheele in 1786. It is a naturally occurring low-molecular-weight tri phenolic compound. Its chemical name is 3,4,5-trihydroxy benzoic acid. It is also known as trihydroxy benzoic acid. It exists both independently and as a component of tannins (specifically, gallotannin). Bark, wood, leaves, fruits, roots, and seeds are only some of the plant parts that contain gallic acid or its derivatives. Mechanism of action: Gallic acid has been shown to be selectively hazardous for cancer cells while having no effect on normal cells, inducing the death of cancer cells via mitochondria-mediated mechanisms. Gallic acid has been credited with a number of health benefits, including antioxidant, anti-inflammatory, and anticancer actions. It has a specific beneficial role in the apoptosis of cancer cells and brain health.
51.1.1 Experimental Work
Materials, Reagents, and Chemicals
The pure form of gallic acid, HPLC grade water, acetonitrile, triethyl amine, and formic acid (Rankem), and pipettes, beakers, burettes, and measuring cylinder which are manufactured by Borosil.
Equipment
HPLC (Alliance) was manufactured by Waters e 2695 – Empower software 2.0 versions, UV–vis spectrophotometer by UV-1700, and ultrasonicator (UCA 701) by Unichrome and PH meter by Eutech.
51.1.2 General Preparations
Preparation of Standard Stock Solution
Accurately weigh and transfer 100 mg of gallic acid working standard into a 100 mL clean dry volumetric flask, add diluent and sonicate to dissolve it completely, and make volume up to the mark with the same solvent (stock solution). Further pipette 5 mL of the above stock solutions into a 50 ml volumetric flask and dilute up to the mark with diluent (100 ppm of gallic acid).
Preparation of Buffer (0.1% Formic Acid)
1 mL of the formic acid is dissolved in 1 L of HPLC water and filtered through 0.45 μ membrane filter paper.
Preparation of Mobile Phase
Mobile phase was prepared by mixing 0.1% formic acid and ACN taken in the ratio 70:30. It was filtered through a 0.45 μ membrane filter to remove the impurities, which may interfere in the final chromatogram.
Chromatographic Condition
Multiple trails were run to determine the optimal chromatographic settings for this approach use suitable high-performance liquid chromatographic equipped with PDA detector.
Column: | Waters X-Terra RP-18 (150 × 4.6 mm, 3.5 μ) |
Movable phase: | Acetonitrile and 0.1% formic acid (30:70) |
Wavelength: | 275 nm |
Flow rate: | 1 mL/min |
Injection volume: | 10 μL |
Run time: | 5 min |
Preparation of Diluent
Mobile phase was used as a diluent.
Preparation of Standard Solution
Accurately weigh and transfer 100 mg of gallic acid working standard into a 100 mL clean dry volumetric flask, add diluent and sonicate to dissolve it completely, and make volume up to the mark with the same solvent (stock solution).
Further pipette 5 mL of the above stock solutions into a 50 mL volumetric flask and dilute up to the mark with diluent (100 ppm of gallic acid).
Procedure
Inject 10 μL of the standard, sample into the chromatographic system and measure the areas for gallic acid peak and calculate the %assay by using the formulae.
Determination of Working Wavelength (λmax)
The isosbestic wavelength was utilized to make an estimate of the drug’s potency. At the isosbestic point, the molar absorptivity of all interconvertible compounds is equal to one another. That is why we relied on this wavelength for our precise medication estimations.
The wavelength of maximum absorption of the solution of the drug in a mixture of acetonitrile and 0.1% formic acid (30:70) was scanned using PDA detector within the wavelength region of 200–400 nm against acetonitrile and 0.1% formic acid (30:70) as blank. The absorption curve shows an isosbestic point at 275 nm. Thus 275 nm was selected as the detector wavelength for the HPLC chromatographic method.
51.1.3 Syrup Formulation
Preparation of Simple Syrup
Weigh 66.35 g of sucrose. Add sucrose in hot purified water under continuous stirring until it dissolved. Kept aside for cooling.
Preparation of Gallic Acid Syrup
Add gallic acid, preservative (sodium benzoate), diluents, and sweetener (glycerine) in the above simple syrup. Stir the solution for 20 min. After cooling, filter the final syrup through filter paper.
System Suitability
The tailing factor for the peak due to gallic acid in standard solution should not be more than 2.0.
Theoretical plates for the gallic acid peak in standard solution should not be less than 2000.
Formula for Assay
where:
-
AT = average area counts of test (sample) preparation
-
AS = average area counts of standard preparation
-
WS = weight of working standard taken in mg
-
DS = dilution of working standard in mL
-
DT = dilution of test (sample) in mL
-
WT = weight of test (sample) taken in mg
-
P = percentage purity of working standard
-
LC = Label claim mg/mL
Procedure
Inject each level into the chromatographic system and measure the peak area.
Plot a graph of peak area versus concentration (on the X-axis concentration and on the Y-axis peak area) and calculate the correlation coefficient.
Range
The range of an analytical technique is the concentration range across which its precision, accuracy, and linearity have been shown.
Inclusion Criteria
Correlation coefficient should be not less than 0.999.
51.1.4 Preparation Accuracy Sample Solutions
For the Preparation of 50% Solution (with Respect to Target Assay Concentration)
Accurately weigh and transfer 50 mg of gallic acid standard into a 100 mL clean dry volumetric flask, add diluent and sonicate to dissolve it completely, and make volume up to the mark with the same solvent (stock solution).
Further pipette 5 mL of the above stock solutions into a 50 mL volumetric flask and dilute up to the mark with diluent (50 ppm of gallic acid).
For the Preparation of 100% Solution (with Respect to Target Assay Concentration)
Accurately weigh and transfer 100 mg of gallic acid standard into a 100 mL clean dry volumetric flask, add diluent and sonicate to dissolve it completely, and make volume up to the mark with the same solvent (stock solution).
Further pipette 5 mL of the above stock solutions into a 50 mL volumetric flask and dilute up to the mark with diluent.(100 ppm of gallic acid).
For the Preparation of 150% Solution (with Respect to Target Assay Concentration)
Accurately weigh and transfer 150 mg of gallic acid standard into a 100 mL clean dry volumetric flask, add diluent and sonicate to dissolve it completely, and make volume up to the mark with the same solvent (stock solution).
Further pipette 5 mL of the above stock solutions into a 50 mL volumetric flask and dilute up to the mark with diluent (150 ppm of gallic acid).
Procedure
Inject the standard solution, accuracy – 50%, accuracy – 100%, and accuracy – 150% solutions.
Inclusion Criteria
The % recovery for each level should be between 98.0% and 102.0%.
Precision
Precision is the degree of repeatability of an analytical method under normal operating conditions. Precision is of three types:
-
1.
System precision
-
2.
Method precision
-
3.
Intermediate precision (a. Intraday precision, b. Interday precision)
System precision is checked by using standard chemical substances to ensure that the analytical system is working properly.
In this peak area, % of drug of six determinations is measured and % RSD should be calculated.
In method precision, a homogenous sample of a single batch should be analyzed six times. This indicates whether a method is giving constant results for a single batch. In this, analyze the sample six times and calculate the % RSD.
The precision of the instrument was checked by repeatedly injecting (n = 6) solutions of 100 ppm of gallic acid.
Acceptance Criteria
The % RSD for the absorbance of six replicate injection results should not be more than 2%.
Robustness
As part of the robustness, deliberate change in the flow rate, mobile phase composition, temperature variation was made to evaluate the impact on the method.
-
A.
The flow rate was varied from 0.9 mL/min to 1.1 m.
-
A standard solution of 100 ppm of gallic acid was prepared and analyzed using the varied flow rates along with the method flow rate.
-
On the evaluation of the above results, it can be concluded that the variation in flow rate affected the method significantly. Hence, it indicates that the method is robust even with a change in the flow rate ± 10%.
-
-
B.
The variation of the Organic Phase ratio.
-
A standard solution of 100 ppm of gallic acid was prepared and analyzed using the varied in mobile phase ratio.
-
Limit of Detection (LOD) and Limit of Quantification (LOQ)
The limit of detection (LOD) and limit of quantification (LOQ) of the drug carry were calculated using the following equation as per international conference harmonization (ICH) guidelines.
LOD for gallic acid was found to be 0.3 μg/mL and LOQ for gallic acid was found to be 1 μg/mL.
51.1.5 Degradation Studies
Preparation of Stock
Accurately weigh and transfer 100 mg of Gallic acid working standard into a 100 mL clean dry volumetric flask, add diluent and sonicate to dissolve it completely, and make volume up to the mark with the same solvent (stock solution).
Acid Degradation
Pipette 5 mL of the aforementioned solution was added to a 50 mL vacuum flask, followed by 3 mL of 1 N HCl. The vacuum flask was then maintained at 60 °C for 6 h before being neutralized with 1 N NaOH and diluted to 50 mL with diluent. Filter the solution using 0.22-micron syringe filters and transfer it to bottles.
Alkali Degradation
Pipette 5 mL of the above solution into a 50 mL volumetric flask and add 3 mL of 1 N NaOH was added. Then, the volumetric flask was kept at 60 °C for 6 h and then neutralized with 1 N HCl and make up to 50 mL with diluent. Filter the solution with 0.22 microns syringe filters and place it in vials.
Thermal-Induced Degradation
Gallic acid sample was taken in Petri dish and kept in a hot air oven at 105 °C for 24 h. Then the sample was taken and diluted with diluents and injected into HPLC and analyzed.
Peroxide Degradation
Pipette 5 mL above stock solution was added to a 50 mL vacuum flask, 1 mL of 3% w/v hydrogen peroxide was added to the flask and the volume was built up to the mark using diluent. The vacuum flask was then maintained at 60 °C for 6 h. After that, the vacuum flask was left at room temperature for 15 min. Filter the solution using 0.45-micron syringe filters and transfer it to bottles.
Reduction Degradation
Pipette 5 mL of above-stock solution was added to a 50 mL vacuum flask, 1 mL of 10% sodium bisulfate was added to a flask and the volume was built up to the required volume with diluent. The vacuum flask was then maintained at 60 °C for 6 h. After that, the vacuum flask was left at room temperature for 15 min. Filter the solution using 0.45-micron syringe filters and transfer it to bottles.
Photolytic Degradation
Gallic acid sample was placed in sunlight for 24 h. Then the sample was taken and diluted with diluents and injected into HPLC and analyzed.
Hydrolysis Degradation
Pipette 5 mL of above-stock solution was added to a 50 mL vacuum flask, 1 mL of HPLC grade water was added to a flask and the volume was built up to the required volume with diluent. The vacuum flask was then maintained at 60 °C for 6 h. After that, the vacuum flask was left at room temperature for 15 min. Filter the solution using 0.45-micron syringe filters and transfer it to bottles.
51.3 Analytical Method Validation (HPLC)
The method’s linearity, accuracy, precision, and specificity were all confirmed to be satisfactory. The method was validated in accordance with ICH standards.
Linearity
Accuracy (Table 51.2, Figs. 51.6, 51.7 and 51.8)
Precision (Tables 51.3, 51.4 and Fig. 51.9)
Acceptance Criteria
The % RSD for the area of six standard injections results should not be more than 2% (Table 51.5 and Fig. 51.10).
Acceptance Criteria
The % RSD for the area of six standard injection results should not be more than 2%.
Robustness (Table 51.6, Figs. 51.11, 51.12, 51.13 and 51.14)
Results of Linearity for Gallic Acid (Fig. 51.5)
S. no | Gallic acid | |
---|---|---|
Conc. (μg/mL) | Peak area | |
1 | 25.00 | 512,492 |
2 | 50.00 | 1,033,316 |
3 | 75.00 | 1,474,077 |
4 | 100.00 | 2,016,525 |
5 | 125.00 | 2,533,019 |
6 | 150.00 | 3,023,594 |
Regression equation | y = 20135.78x + 3105.61 | |
Slope | 20135.78 | |
Intercept | 3105.61 | |
R 2 | 0.9998 |
LOD and LOQ (Table 51.7, Figs. 51.15 and 51.16)
Degradation Studies (Figs. 51.17, 51.18, 51.19, 51.20, 51.21, 51.22, 51.23, 51.24 and Table 51.8)
51.4 Conclusion
The devised HPLC technique for estimating the target drug is easy to use, quick to implement, highly reliable, and cheap. Both the mobile phase and the solvents are easily accessible, inexpensive, dependable, sensitive, and quick to prepare. The sample recoveries revealed noninterference of formulation excipients in the estimate, and they may be utilized in labs for the regular analysis of chosen medications, all of which were in excellent agreement with their individual label claims. Since the HPLC method’s system validation parameters have demonstrated good, accurate, and repeatable findings (without any interference of excipients), it can be inferred that the quick and easy procedures presented will be most beneficial for analysis. This study found that the stability indicating test technique by RP-HPLC was straightforward, reproducible, sensitive, and specific, with no cross-contamination from placebo or degradation products. So, they are suitable for regular gallic acid testing.
References
Robert DB (2006) Introduction to instrumental analysis. Pharma Med Press, Hyderabad
James WM (ed) (2001) Pharmaceutical analysis. Part B, International Medicalbook Distributors, New Delhi
Frank AS (ed) (2007) Handbook of instrumental techniques for analytical chemistry. Pearson Education Publishers, New Delhi
John A (ed) (2006) Chromatographic analysis of pharmaceutical, 2nd edn. Marcel Dekker, New York
Kazakevich YV, Lo Brutto R (eds) (2007) HPLC for pharmaceutical scientists. Wiley, Hoboken
Neue UD (1997) HPLC columns: theory, technology, and practice. Wiley-VCH, New York
Beckett AH, Stenlake JB (1997) Practical pharmaceutical chemistry, 4th edn. Vol. I & II CBS Publishers and Distributors, New Delhi
Satinder A, Henrik R (eds) (2007) HPLC method development for pharmaceuticals, vol 8. Elsevier Publishers, Noida
Snyder LR, Kirkland JJ, Glajch JL (eds) (1997) Practical HPLC method development, 2nd edn. Willey International Publication
Mc Loughlin DA, Olah TV, Gilbert JD (1997) A direct technique for the simultaneous determination of 10 drug candidates in plasma by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry interfaced to a prospect solid-phase extraction system. J Pharm Biomed Anal 15(12):1893–1901
Swartz ME (2004) Ultra performance liquid chromatography: tomorrows HPLC technology today. Lab Plus Int 18(3):6–9
Swart ME (2004) Degradation analysis using UPLC. Pharm Formul Qual 6(5):40–42
International Conference on Harmonization (ICH) (1994) Validation of analytical methods definitions and terminology, ICH Q2A
International Conference on Harmonization (ICH) (1996) Validation of analyticalmethods: methodology, ICH Q2 B
Smith G (2010) Bioanalytical method validation: notable points in the 2009 draft EMA guideline and differences with the 2001 FDA Guidance. Bioanalysis 2(5):929–935
Min SC, Qin J, Jun Z, Tawkol AE (2007) Historical review of sample preparation for chromatographic bioanalysis: pros and cons. Drug Dev Res 8(3):107–133
Richard RB (2009) Protein precipitation techniques. Methods Enzymol 463:331–341
Watt AP, Morrison D, Locker KL, Evans DC (2000) Higher throughput bioanalysis by automation of a protein precipitation assay using a 96-well format with detection by LC-MS/MS. Anal Chem 72(5):979–984
Ronald EM (2009) Practical aspects of solvent extraction. LC GC Europe 22(3):143–147
Naxing XR, Fan L, Kim GE, El-Shourbagy TA (2006) A monolithic-phase based on-line extraction approach for determination of pharmaceutical components in human plasma by HPLC-MS/MS and a comparison with liquid-liquid extraction. J Pharm Biomed Anal 40(3):728–736
Zhang N, Hoffman KL, Li W, Rossi DT (2000) Semi-automated 96-well liquid- liquid extraction for quantitation of drugs in biological fluids. J Pharm Biomed Anal 22(1):131–138
Nigel Simpson JK (ed) (2000) Solid-phase extraction: principles, techniques and applications, 1st edn. Marcel Dekker, New York, pp 307–330
Krishnan TR, Ibrahim I (1994) Solid-phase extraction technique for the analysis of biological samples. J Pharm Biomed Anal 12(3):287–294
Schellen A, Ooms B, Van de Lagemaat D, Vreeken R, Van Dongen WD (2003) Generic solid phase extraction-liquid chromatography-tandem mass spectrometry method for fast determination of drugs in biological fluids. J Chromatogr B 788(2):251–259
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 The Author(s), under exclusive license to Springer Nature Switzerland AG
About this paper
Cite this paper
Roja, A., Maheshwari, P.U., Munemma, R., Swathi, K. (2023). Method Development and Validation of Gallic Acid in Liquid Dosage Form by Using RP-HPLC Method. In: Vlamos, P. (eds) GeNeDis 2022. GeNeDis 2022. Advances in Experimental Medicine and Biology, vol 1425. Springer, Cham. https://doi.org/10.1007/978-3-031-31986-0_51