Abstract
This study presents the fatigue durability of a cantilevered deck slab strengthened by Near-Surface-Mounted (NSM) method using Carbon Fiber Reinforced Polymer (CFRP) rods. The CFRP rod manufactured by PULTRUSION method has ultra-high modulus of 450 GPa. The study used a polymer-cementitious mortar of ultra-high-early strength as a filling material for CFRP rod while the rod is generally embedded in epoxy-resin mortar/adhesive. The ultra-high-early strength mortar can contribute to shortening the construction term for strengthening upper-deck slabs. The CFRP rod has little shear-resistance ribs, so the bond performance in concrete is significantly low. In this study, Glass Fiber Reinforced Polymer (GFRP) ribs were attached to CFRP rods to improve the bond performance. To examine the fatigue durability, the study conducted a moving-wheel load test for a cantilevered deck slab embedding the bond-improved CFRP rods. The test shows that the cantilevered deck slab strengthened with the bond-improved CFRP rods had the excellent fatigue durability even to 150% higher wheel load than the load in Japanese design code.
Access provided by Autonomous University of Puebla. Download conference paper PDF
Similar content being viewed by others
1 Introduction
Fatigue is a serious concern for bridge deck slabs directly subjected to wheel load. Heavy traffic load and de-icing materials significantly accelerates fatigue damage of the slab. In particular, cantilevered deck slabs under negative bending moment have been remarkably damaged. Near-Surface-Mounted (NSM) is an effective strengthening method for concrete members under fatigue loading (Teng et al. 2001; Yoshitake et al. 2010; Dongkeun et al. 2011). This study focuses on the NSM strengthening method using a Carbon Fiber Reinforced Polymer (CFRP) rod of ultra-high modulus and a polymer-cementitious mortar of ultra-high-early strength. The greatest concern in the NSM strengthening is the significant low-bonding property of the CFRP rod embedded in the mortar. Our previous study developed a bond-improved CFRP rod attaching Glass Fiber Reinforced Polymer (GFRP) ribs and conducted monotonic and cyclic loading tests of RC beams strengthened with the bond-improved CFRP rods (Hasegawa et al. 2016; Kuroda et al. 2016; Hasegawa et al. 2018; Hasegawa et al. 2019; Yoshitake et al. 2020). The flexural loading test showed excellent fatigue durability of the beams. This study conducted a moving-wheel load test to confirm the fatigue durability of the strengthened deck slab. The present paper reports the fatigue property of the slab.
2 Moving-Wheel Loading Test
2.1 Materials
Table 1 shows the material properties used in this study. Compressive strength and Young’s modulus of concrete at 28 days were 29.5 MPa, 32.5 GPa, respectively. The strength of the polymer-cementitious mortar was significantly higher than the concrete strength. The compressive strength and Young’s modulus of the mortar at 28 days were 55.9 MPa, 30.8 GPa, respectively. The modulus of the mortar was slightly lower than the modulus of concrete to reduce the interfacial shear stress. Young’s modulus of CFRP rod of 8 mm diameter was 440 GPa. The modulus is 2.1 times higher than the modulus of steel reinforcement. The ultra-high modulus CFRP rod must contribute to the reduction of the rebar stress and the deflection of deck slab. Note is that the CFRP rod indicates low bond strength because of smooth surface. To improve the bond strength in concrete, the CFRP rods were wrapped with GFRP prepreg sheets to add the shear-resistance ribs (Fig. 1a). Dimensions of GFRP ribs were 1.5 mm thick, 75 mm long, 300 mm interval (Fig. 1b).
2.2 Cantilevered Slab Specimen
Figure 2 shows the preparation process of the cantilevered slab specimen strengthened with CFRP rods. A RC slab of 140 mm thick was firstly made and thin concrete-cover of top surface was removed by using water-jet (Fig. 2a). The top surface was coated with epoxy resin at the concrete age of 58 days (Fig. 2b). The polymer-cementitious mortar of 20 mm thick was cast on the fresh epoxy resin. The bond-improved CFRP rods were embedded in the mortar (Fig. 2c). The embedment depth of CFRP rod was approximately 15 mm. Figure 2d shows the moving-wheel load of two solid rubber tires.
2.3 Experimental Procedure
Figure 3 shows the schematic of RC slab specimen. Dimensions of the specimen were 3050 mm width, 4500 mm long, 160 mm thick. The CFRP rods (Dia. 8 mm) and main rebars (SD345 D13) intervals (center to center) were 200 mm, 150 mm respectively. The slab end was fixed with a H-steel of 150 mm height and PC bars of 13 mm diameter. The cantilevered slab was supported on a rigid steel bar of 50 mm diameter which was placed at 1600 mm from the fixed edge. The cantilevered span was 1000 mm. The moving span of wheel load was 3600 mm. The wheel load of 60 kN was applied on the slab specimen up to 1,000,000 cycles. After that, the increased load of 70 kN was applied up to 120,000 cycles. The maximum stress of the rebar was calculated as 210 MPa under the loading of 60 kN. The stress is 1.5 times higher than the allowable stress under the service load (Japan Road Association 2017). The strains of CFRP rod and reinforcing bar and the free-end deflection were monitored during the moving-wheel load test (Fig. 3).
3 Test Results and Discussion
3.1 Cracking Behavior
Figure 4 shows the crack pattern of specimen subjected to 1,120,000 wheel-loads (1,000,000 cycles for 60 kN + 120,000 cycles for 70 kN). When the wheel load was applied on the slab end (D/F), the cantilevered slab was subjected to the maximum moment. Crack-I (A – E and C – E) occurred due to the maximum bending moment until 1,000 cycles. A longitudinal crack (Crack-II) at the support occurred and developed from 100,000 to 150,000 loading cycles because the flexural rigidity of the cantilevered slab decreased by the flexural cracks (Crack-I). The transverse crack (Crack-III) occurred up to 600,000 cycles. After that, remarkable cracks were hardly observed until 1,120,000 cycles.
3.2 Estimation of Equivalent Loading Cycles
The moving-wheel load test had been conducted to estimate the fatigue durability of bridge deck slabs. Maeda and Matsui (1984) reported that the moving-wheel load test could simulate the fatigue failure of the slab. Matsui (1991) proposed an empirical equation (Eq. 1) to estimate the fatigue life of RC deck slab based on the moving-wheel load test. Kaido and Matsui (2008) also reported that the fatigue durability of cantilevered steel–concrete composite slabs can be estimated by Eq. (1). The study assumed that Miner's linear rules are applicable for the fatigue damage accumulation. The equivalent cycles for the different loads can be calculated by using Eq. (2).
where P is wheel load; Psx is static loading capacity of the slab; k is coefficient (0.07835); N is the ultimate loading cycle; C is coefficient (1.23 for wet and 1.52 for dry); neq1 is equivalent loading cycle and ni is loading cycle.
Based on these assumptions, the loading history (1 million cycles for 60 kN + 120,000 cycles for 70 kN) was equivalent to 2 million cycles for the initial load of 60 kN. The cantilevered slab strengthened with NSM CFRP rods endured 2 million loading cycles even under the 150% higher wheel load than the service load (Japan Road Association 2017).
3.3 Deformation
Figure 5 shows the deflection at the free-end of the cantilevered slab (point E in Fig. 4). The deflection increased significantly due to the flexural cracking (Crack-II), and gradually increased after 150,000 cycles. Figure 5 also shows that the deflection slightly increased by the occurrence of Crack-III at 600,000 cycles.
Figure 6 shows the strains of rebar and CFRP at point B in Fig. 4. It presents remarkable increase of strain at 60,000 cycles. The strains increased gradually until 150,000 cycles. The observation implies that invisible flexural cracks occurred on the support. Note is that the invisible cracks had developed to the visible cracks (Crack-II) as increase of load cycles. After 150,000 cycles, there was no significant strain variation except for 600,000 cycles at that Crack-III was occurred. Figure 7 shows the strain distribution of CFRP. The CFRP strain at the support section increased significantly at 150,000 cycles. The CFRP strain at 300 mm from the support increased remarkably. The gradual increase of deflection from 150,000 to 600,000 cycles was caused by the cracking in the fixing section.
Figure 8 shows the strain profiles. The linear profiles imply that debonding or slippage of CFRP rods did not happen. The bond-improved CFRP rod with GFRP ribs indicated the adequate bond property up to equivalent 2 million wheel-loads of 60 kN.
4 Conclusions
This study focused on the fatigue durability of cantilevered RC deck slab strengthened with ultra-high modulus CFRP rods. The moving-wheel loading test of cantilevered deck slab was conducted to examine the fatigue properties. The conclusions of this study are as follows:
-
(1)
The cantilevered RC slab strengthened with the bond-improved CFRP rods endured the equivalent 2 million wheel-loads of 60 kN that was 150% higher than the designed service load. The moving-wheel load test confirmed the adequate fatigue durability.
-
(2)
The deflection and strain after 600,000 cycles were stable until 2 million cycles. The strain profile was linear up to the equivalent 2 million cycles. The observation confirmed that the CFRP rod with GFRP ribs had appropriate bond capacity even under the 2 million cycles of wheel load.
References
Dongkeun L, Lijuan C (2011) Assessing the strengthening effect of various near-surface-mounted FRP reinforcements on concrete bridge slab overhangs. J Compos Constr 15(4):615–624, August
Hasegawa H, Hisabe N, Kuroda Y, Yoshitake I (2016) Flexural behavior of a cantilevered RC slab strengthened with NSM CFRP rods. In: Proceedings of ACMBS-VII, Vancouver, 22 August
Hasegawa H, Hisabe N, Onari Y, Yoshitake I (2018) Improvement of mechanical shear resistance of high modulus CFRP rod with GFRP ribs. In: Proceedings of the 9th international conference on FRP composites in civil engineering, Paris, 18 July
Hasegawa H, Onari Y, Shimose K, Yoshitake I (2019) Cyclic loading test of flexural RC member embedding bond-improved high modulus CFRP rods. In: International conference of bridge engineering institute, Honolulu, 24 July
Japan Road Association (2017) Specifications for highway bridges, Part II, Chapter 11 Decks, pp 284–337
Kaido H, Matsui S (2008) Evaluation for fatigue strength of shear studs in steel plate-concrete composite deck. J Japan Soc Civil Eng 64(4):765–777
Kuroda Y, Hasegawa H, Hisabe N, Yoshitake I (2016) Strengthening effect of a CFRP rod having ribs for a cantilevered slab. In: Proceedings of 6th international conference of GEOMATE, pp 420–425, Bangkok, 15 November
Maeda Y, Matsui S (1984) Experimental study of fatigue durability of RC deck slab by moving-wheel load test. Proc JCI 6:221–224 (in Japanese)
Matsui S (1991) Prediction of fatigue life of reinforced concrete slabs of highway bridges. Japan Soc Saf Eng 30(6):432–440 (in Japanese)
Teng JG, Cao SY, Lam L (2001) Behaviour of GFRP-strengthened RC cantilever slabs. Constr Build Mater15(7):339–349, Oct
Yoshitake I, Yail KJ, Yumikura K, Hamada S (2010) Moving-wheel fatigue for bridge decks strengthened with CFRP strips subject to negative bending. J Compos Constr 14(6):784–790, Dec
Yoshitake I, Hasegawa H, Kodai S (2020) Monotonic and cyclic loading tests of reinforced concrete beam strengthened with bond-improved carbon fiber reinforced polymer (CFRP) rods of ultra-high modulus. Eng Struct 206, Mar
Acknowledgements
The authors would like to thank Mr. Onari (a former graduate-student of Yamaguchi Univ.) and Mr. Sodbayar (Yamaguchi Univ.) for their support to the experimental study.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 Canadian Society for Civil Engineering
About this paper
Cite this paper
Hasegawa, H., Kato, T., Shimose, K., Yoshitake, I. (2023). Moving-Wheel Load Test of a Cantilevered RC Slab Strengthened with Bond-Improved Ultra-High Modulus CFRP Rods. In: Benmokrane, B., Mohamed, K., Farghaly, A., Mohamed, H. (eds) 8th International Conference on Advanced Composite Materials in Bridges and Structures. Lecture Notes in Civil Engineering, vol 278. Springer, Cham. https://doi.org/10.1007/978-3-031-09632-7_5
Download citation
DOI: https://doi.org/10.1007/978-3-031-09632-7_5
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-031-09631-0
Online ISBN: 978-3-031-09632-7
eBook Packages: EngineeringEngineering (R0)