Skip to main content

Pulsation and Counterpulsation

  • Living reference work entry
  • First Online:
Mechanical Circulatory Support

Abstract

Heart failure remains a leading cause of morbidity and mortality in the United States. While heart transplantation remains the definitive treatment for patients with advanced disease, limited availability of healthy donor organs restricts this life-saving procedure. An alternative therapy is the use of mechanical circulatory support (MCS) devices to supplement native cardiac function using either ventricular assist devices (VAD), or, counterpulsation devices. Despite providing long-term support, VAD implantation is only offered to the sickest patients due to the invasive nature of the procedure (sternotomy, thoracotomy) and high complication rate. The intra-aortic balloon pump (IABP) is a counterpulsation device that functions by augmenting diastole leading to decreased cardiac workload and increased coronary perfusion. Due to its minimally invasive design and significant hemodynamic benefit, the IABP is the most commonly used device as a bridge to transplant. Nevertheless, IABPs were only designed for short-term use limiting their utility beyond the in-patient setting. The recent development of a novel ambulatory IABP device (iVAS NuPulse, Raleigh, NC) may expand the use of counterpulsation therapy to patients at home and provides a versatile minimally invasive solution that may avoid the complications associated with VAD placement. These benefits make this device ideally suited to provide a long-term solution that may function as a bridge to recovery or destination therapy.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Similar content being viewed by others

References

  • Auricchio A, et al. Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure. The Pacing Therapies for Congestive Heart Failure Study Group. The Guidant Congestive Heart Failure Research Group. Circulation. 1999;99:2993–3001.

    Article  CAS  PubMed  Google Scholar 

  • Bregman D, Casarella WJ. Percutaneous intraaortic balloon pumping: initial clinical experience. Ann Thorac Surg. 1980;29:153–5.

    Article  CAS  PubMed  Google Scholar 

  • Clauss RH, et al. Assisted circulation. I. The arterial counterpulsator. J Thorac Cardiovasc Surg. 1961;41:447–58.

    Article  CAS  PubMed  Google Scholar 

  • Colvin M, et al. OPTN/SRTR 2020 annual data report: heart. Am J Transplant. 2022;22:350–437.

    Article  PubMed  Google Scholar 

  • Davies AN, et al. Extra-ascending aortic versus intra-descending aortic balloon counterpulsation-effect on coronary artery blood flow. Heart Lung Circ. 2005;14:178–86.

    Article  PubMed  Google Scholar 

  • Dennis C, et al. Studies external counterpulsation as a potential measure for acute left heart failure. Trans Am Soc Artif Intern Organs. 1963;9:186–91.

    CAS  PubMed  Google Scholar 

  • Dick P, et al. Decreasing incidence of critical limb ischemia after intra-aortic balloon pump counterpulsation. Angiology. 2009;60:235–41.

    Article  PubMed  Google Scholar 

  • Estep JD, et al. Percutaneous placement of an intra-aortic balloon pump in the left axillary/subclavian position provides safe, ambulatory long-term support as bridge to heart transplantation. JACC Heart Fail. 2013;1:382–8.

    Article  PubMed  Google Scholar 

  • Ferguson JJ, et al. The current practice of intra-aortic balloon counterpulsation: results from the Benchmark Registry. J Am Coll Cardiol. 2001;38:1456–62.

    Article  PubMed  Google Scholar 

  • Giridharan GA, Pantalos GM, Litwak KN, Spence PA, Koenig SC. Predicted hemodynamic benefits of counterpulsation therapy using a superficial surgical approach. ASAIO J Am Soc Artif Intern Organs. 2006;1992(52):39–46.

    Article  Google Scholar 

  • Griffith BP, et al. Genetically modified porcine-to-human cardiac xenotransplantation. N Engl J Med. 2022. https://doi.org/10.1056/NEJMoa2201422.

  • Hayward CS, et al. Chronic extra-aortic balloon counterpulsation: first-in-human pilot study in end-stage heart failure. J Heart Lung Transplant Off Publ Int Soc Heart Transplant. 2010;29:1427–32.

    Article  Google Scholar 

  • Heidenreich PA, et al. Forecasting the impact of heart failure in the United States. Circ Heart Fail. 2013;6:606–19.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  • Hozain AE, et al. Multi-day maintenance of extracorporeal lungs using cross-circulation with conscious swine. J Thorac Cardiovasc Surg. 2019. https://doi.org/10.1016/j.jtcvs.2019.09.121.

  • Imamura T, et al. Improvement in biventricular cardiac function after ambulatory counterpulsation. J Card Fail. 2019;25:20–6.

    Article  PubMed  Google Scholar 

  • Jackson SL, et al. National burden of heart failure events in the United States, 2006 to 2014. Circ Heart Fail. 2018;11:e004873.

    Article  PubMed  PubMed Central  Google Scholar 

  • Jeevanandam V, et al. Circulatory assistance with a permanent implantable IABP: initial human experience. Circulation. 2002;106:I183–8.

    Article  PubMed  Google Scholar 

  • Jeevanandam V, et al. The first-in-human experience with a minimally invasive, ambulatory, counterpulsation heart assist system for advanced congestive heart failure. J Heart Lung Transplant Off Publ Int Soc Heart Transplant. 2018;37:1–6.

    Article  Google Scholar 

  • Kantrowitz A. Experimental augmentation of coronary flow by retardation of the arterial pressure pulse. Surgery. 1953;34:678–87.

    CAS  PubMed  Google Scholar 

  • Kantrowitz A, McKinnon WM. The experimental use of the diaphragm as an auxiliary myocardium. Surg Forum. 1958;9:266–8.

    CAS  PubMed  Google Scholar 

  • Kantrowitz A, et al. A clinical experience with an implanted mechanical auxiliary ventricle. JAMA. 1966;197:525–9.

    Article  CAS  PubMed  Google Scholar 

  • Kantrowitz A, et al. Intraaortic balloon pumping. JAMA. 1968a;203:988.

    Article  CAS  PubMed  Google Scholar 

  • Kantrowitz A, et al. Mechanical intraaortic cardiac assistance in cardiogenic shock. Hemodynamic effectsHemodynamic effects. Arch Surg Chic Ill. 1968b;1960(97):1000–4.

    Article  Google Scholar 

  • Kantrowitz A, et al. Initial clinical experience with a new permanent mechanical auxiliary ventricle: the dynamic aortic patch. Trans Am Soc Artif Intern Organs. 1972;18:159–67, 179.

    Article  CAS  PubMed  Google Scholar 

  • Kass DA, et al. Improved left ventricular mechanics from acute VDD pacing in patients with dilated cardiomyopathy and ventricular conduction delay. Circulation. 1999;99:1567–73.

    Article  CAS  PubMed  Google Scholar 

  • Kawaguchi O, Pae WE, Daily BB, Pierce WS. Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure. J Thorac Cardiovasc Surg. 1999;117:164–71.

    Article  CAS  PubMed  Google Scholar 

  • Koenig SC, Spence PA, Pantalos GM, Dowling RD, Litwak KN. Development and early testing of a simple subcutaneous counterpulsation device. ASAIO J Am Soc Artif Intern Organs. 2006;1992(52):362–7.

    Article  Google Scholar 

  • Mayer JH. Subclavian artery approach for insertion of intra-aortic balloon. J Thorac Cardiovasc Surg. 1978;76:61–3.

    Article  CAS  PubMed  Google Scholar 

  • Molina EJ, et al. The Society of Thoracic Surgeons Intermacs 2020 annual report. Ann Thorac Surg. 2021;111:778–92.

    Article  PubMed  Google Scholar 

  • Moulopoulos SD, Topaz S, Kolff WJ. Diastolic balloon pumping (with carbon dioxide) in the aorta – a mechanical assistance to the failing circulation. Am Heart J. 1962;63:669–75.

    Article  CAS  PubMed  Google Scholar 

  • Nishida H, et al. Outcomes of ambulatory axillary intraaortic balloon pump as a bridge to heart transplantation. Ann Thorac Surg. 2021;111:1264–70.

    Article  PubMed  Google Scholar 

  • Nishida H, et al. Ten-year, single center experience of ambulatory axillary intra-aortic balloon pump support for heart failure. J Cardiol. 2022;79:611–7.

    Article  PubMed  Google Scholar 

  • Page A, Messer S, Large SR. Heart transplantation from donation after circulatory determined death. Ann Cardiothorac Surg. 2018;7:75–81.

    Article  PubMed  PubMed Central  Google Scholar 

  • Sales VL, McCarthy PM. Understanding the C-pulse device and its potential to treat heart failure. Curr Heart Fail Rep. 2010;7:27–34.

    Article  PubMed  Google Scholar 

  • Scheidt S, et al. Intra-aortic balloon counterpulsation in cardiogenic shock. N Engl J Med. 1973;288:979–84.

    Article  CAS  PubMed  Google Scholar 

  • Sintek MA, et al. Intra-aortic balloon counterpulsation in patients with chronic heart failure and cardiogenic shock: clinical response and predictors of stabilization. J Card Fail. 2015;21:868–76.

    Article  PubMed  PubMed Central  Google Scholar 

  • Song TH, Jeevanandam V. Technique of percutaneous supraclavicular subclavian intra-aortic balloon pump placement. JTCVS Tech. 2021;8:20–2.

    Article  PubMed  PubMed Central  Google Scholar 

  • Soroff HS, Birtwell WC, Levine HJ, Bellas AE, Deterling RA. Effect of counterpulsation upon the myocardial oxygen consumption and heart work. Surg Forum. 1962;13:174–6.

    CAS  PubMed  Google Scholar 

  • Starling RC, et al. Risk assessment and comparative effectiveness of left ventricular assist device and medical management in ambulatory heart failure patients: the ROADMAP study 2-year results. JACC Heart Fail. 2017;5:518–27.

    Article  PubMed  Google Scholar 

  • Stefanadis C, et al. Aortic function in patients during intra-aortic balloon pumping determined by the pressure-diameter relation. J Thorac Cardiovasc Surg. 1998;116:1052–9.

    Article  CAS  PubMed  Google Scholar 

  • Subramanian VA, et al. Preliminary clinical experience with percutaneous intraaortic balloon pumping. Circulation. 1980;62:I123–9.

    CAS  PubMed  Google Scholar 

  • Tanaka A, et al. The subclavian intraaortic balloon pump: a compelling bridge device for advanced heart failure. Ann Thorac Surg. 2015;100:2151–7; discussion 2157–8.

    Article  PubMed  Google Scholar 

  • Uriel N, et al. Clinical outcomes and quality of life with an ambulatory counterpulsation pump in advanced heart failure patients. Circ Heart Fail. 2020;13:e006666.

    Article  PubMed  Google Scholar 

  • Webb CA-J, Weyker PD, Flynn BC. Management of intra-aortic balloon pumps. Semin Cardiothorac Vasc Anesth. 2015;19:106–21.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Valluvan Jeevanandam .

Editor information

Editors and Affiliations

Section Editor information

Rights and permissions

Reprints and permissions

Copyright information

© 2023 Springer Nature Switzerland AG

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Hozain, A.E., Jeevanandam, V. (2023). Pulsation and Counterpulsation. In: Arabía, F.A. (eds) Mechanical Circulatory Support. Springer, Cham. https://doi.org/10.1007/978-3-030-86172-8_58-1

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-86172-8_58-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-86172-8

  • Online ISBN: 978-3-030-86172-8

  • eBook Packages: Springer Reference MedicineReference Module Medicine

Publish with us

Policies and ethics