It is estimated that 1 in 11 adult population in the world is living with diabetes. Till date, the best approach toward management of diabetes involves monitoring of glucose levels and administration of insulin accordingly. While this can be done through frequent self-monitoring of glucose at home, these point measurements lack valuable information related to the glucose excursions. Continuous glucose monitoring of glucose has proven to be beneficial in type 1 diabetes and has helped in reduction of glycated hemoglobin and episodes of hypoglycemia. Over the years, the technologies used for the development of continuous glucose monitoring sensors have further improved yielding accurate and reliable sensors. In this chapter, we present a brief introduction on glucose monitoring sensors and how these sensors evolved toward continuous glucose monitoring sensors for long-term monitoring in the skin interstitial fluid. We also give an overview of the electronics system for glucose sensing and trends in research. For the sake of simplicity, we limit our discussions to electrochemical glucose biosensors.
Similar content being viewed by others
References
Bollella P, Sharma S, Cass AEG, Antiochia R (2019) Microneedle-based biosensor for minimally-invasive lactate detection. Biosens Bioelectron 123:152–159
Burrin JM, Alberti KG (1990) What is blood glucose: can it be measured? Diabet Med 7:199–206
Cass AEG, Davis G, Francis GD, Hill HAO, Aston WJ, Higgins IJ, Plotkin EV, Scott LDL, Turner APT (1984) Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Anal Chem 56(4):667–667
Cengiz E, Tamborlane WV (2009) A tale of two compartments: interstitial versus blood glucose monitoring. Diabetes Technol Ther 11(Suppl 1):S11–S16. https://doi.org/10.1089/dia.2009.0002
Clark LC Jr, Lyons C (1962) Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci 102:29–45
Clarke SF, Foster JR (2012) A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci 69(2):83–93
Degani Y, Heller A (1987) Direct electrical communication between chemically modified enzymes and metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme. J Phys Chem 91(6):1285–1289
El-Sharkawy MF (2015) Bio-inspired systems for treatment of diabetes. Ph.D. thesis, Imperial College. https://doi.org/10.25560/67962
Ferri S, Kojima K, Sode K (2011) Review of glucose oxidases and glucose dehydrogenases: a bird’s eye view of glucose sensing enzymes. J Diabetes Sci Technol 5(5):1068–1076. https://doi.org/10.1177/193229681100500507
Ghoreishizadeh SS, Zhang X, Sharma S, Georgiou P (2018) Study of electrochemical impedance of a continuous glucose monitoring sensor and its correlation with sensor performance. IEEE Sensors letters 2(1):11
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359:1464–1476
Keilin D, Hartree EF (1948) The use of glucose oxidase for the determination of glucose in biological material and for the study of glucose-producing systems by manometric methods. Biochem J 42(2):230–238
Kim YC, Park JH, Prausnitz MR (2012) Microneedles for drug and vaccine delivery. Adv Drug Deliv Rev 64(14):1547–1568
Moodley N, Ngxamngxa U, Turzyniecka MJ, Pillay TS (2015) Historical perspectives in clinical pathology: a history of glucose measurement. J Clin Pathol 68(4):258–264
Niedzwiecki MM, Samant P, Walker DI, Tran V, Jones DP, Prausnitz MR, Miller GW (2018) Human suction blister fluid composition determined using high-resolution metabolomics. Anal Chem 90(6):3786–3792
Park EJ, Werner J, Beebe J, Chan S, Smith NB (2009) Non-invasive ultrasonic glucose sensing with large pigs (approximately 200 pounds) using a lightweight cymbal transducer array and biosensors. J Diabetes Sci Technol 3(3):517–523
Rhee SY, Chon S, Koh G, Paeng JR, Oh S, Woo JT, Kim SW, Kim JW, Kim YS (2007) Clinical experience of an iontophoresis-based glucose measuring system. J Korean Med Sci 22(1):70–73
Sharma S, El-Laboudi A, Reddy M, Jugnee N, Sivasubramaniyam S, El Sharkawy M, Georgiou P, Johnston D, Oliver N, Cass AEG (2018) A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring. Anal Methods 10:2088–2095
Shin JJ, Holtzclaw KR, Dangui ND, Kanderian S Jr, Mastrototaro JJ, Hong PI (2005) Real time self-adjusting calibration algorithm, US patent 6,895,263
Steil GM, Rebrin K, Hariri F, Jinagonda S, Tadros S, Darwin C, Saad MF (2005) Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia. Diabetologia 48:1833–1840
Stylianou S, Kelnar S (2009) The introduction of successful treatment of diabetes mellitus with insulin. J R Soc Med 102(7):298–303
The Diabetes Control and Complications Trial Research Group (1996) Lifetime benefits and costs of intensive therapy as practiced in the diabetes control and complications trial. JAMA 276(17):1409–1415
Vaddiraju S, Tomazos I, Burgess DJ, Jain FC, Papadimitrakopoulos F (2010) Emerging synergy between nanotechnology and implantable biosensors: a review. Biosens Bioelectron 25(7):1553–1565
Van Der Valk PR, Van Der Schatte Olivier-Steding I, Wientjes KJ, Schoonen AJ, Hoogenberg K (2002) Alternative-site blood glucose measurement at the abdomen. Diabetes Care 25:2114–2115
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2021 Springer Science+Business Media, LLC, part of Springer Nature
About this entry
Cite this entry
Ghoreishizadeh, S., Sharma, S. (2021). Continuous Glucose Monitoring Sensors for Management of Diabetes. In: Sawan, M. (eds) Handbook of Biochips. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-6623-9_58-1
Download citation
DOI: https://doi.org/10.1007/978-1-4614-6623-9_58-1
Received:
Accepted:
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-6623-9
Online ISBN: 978-1-4614-6623-9
eBook Packages: Springer Reference EngineeringReference Module Computer Science and Engineering