Skip to main content

Continuous Glucose Monitoring Sensors for Management of Diabetes

State-of-the-Art and Future Perspectives

  • Living reference work entry
  • First Online:
Handbook of Biochips

Abstract

It is estimated that 1 in 11 adult population in the world is living with diabetes. Till date, the best approach toward management of diabetes involves monitoring of glucose levels and administration of insulin accordingly. While this can be done through frequent self-monitoring of glucose at home, these point measurements lack valuable information related to the glucose excursions. Continuous glucose monitoring of glucose has proven to be beneficial in type 1 diabetes and has helped in reduction of glycated hemoglobin and episodes of hypoglycemia. Over the years, the technologies used for the development of continuous glucose monitoring sensors have further improved yielding accurate and reliable sensors. In this chapter, we present a brief introduction on glucose monitoring sensors and how these sensors evolved toward continuous glucose monitoring sensors for long-term monitoring in the skin interstitial fluid. We also give an overview of the electronics system for glucose sensing and trends in research. For the sake of simplicity, we limit our discussions to electrochemical glucose biosensors.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Similar content being viewed by others

References

  • Bollella P, Sharma S, Cass AEG, Antiochia R (2019) Microneedle-based biosensor for minimally-invasive lactate detection. Biosens Bioelectron 123:152–159

    Article  Google Scholar 

  • Burrin JM, Alberti KG (1990) What is blood glucose: can it be measured? Diabet Med 7:199–206

    Article  Google Scholar 

  • Cass AEG, Davis G, Francis GD, Hill HAO, Aston WJ, Higgins IJ, Plotkin EV, Scott LDL, Turner APT (1984) Ferrocene-mediated enzyme electrode for amperometric determination of glucose. Anal Chem 56(4):667–667

    Article  Google Scholar 

  • Cengiz E, Tamborlane WV (2009) A tale of two compartments: interstitial versus blood glucose monitoring. Diabetes Technol Ther 11(Suppl 1):S11–S16. https://doi.org/10.1089/dia.2009.0002

    Article  Google Scholar 

  • Clark LC Jr, Lyons C (1962) Electrode systems for continuous monitoring in cardiovascular surgery. Ann N Y Acad Sci 102:29–45

    Article  Google Scholar 

  • Clarke SF, Foster JR (2012) A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci 69(2):83–93

    Article  Google Scholar 

  • Degani Y, Heller A (1987) Direct electrical communication between chemically modified enzymes and metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme. J Phys Chem 91(6):1285–1289

    Article  Google Scholar 

  • El-Sharkawy MF (2015) Bio-inspired systems for treatment of diabetes. Ph.D. thesis, Imperial College. https://doi.org/10.25560/67962

  • Ferri S, Kojima K, Sode K (2011) Review of glucose oxidases and glucose dehydrogenases: a bird’s eye view of glucose sensing enzymes. J Diabetes Sci Technol 5(5):1068–1076. https://doi.org/10.1177/193229681100500507

    Article  Google Scholar 

  • Ghoreishizadeh SS, Zhang X, Sharma S, Georgiou P (2018) Study of electrochemical impedance of a continuous glucose monitoring sensor and its correlation with sensor performance. IEEE Sensors letters 2(1):11

    Article  Google Scholar 

  • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359:1464–1476

    Article  Google Scholar 

  • Keilin D, Hartree EF (1948) The use of glucose oxidase for the determination of glucose in biological material and for the study of glucose-producing systems by manometric methods. Biochem J 42(2):230–238

    Article  Google Scholar 

  • Kim YC, Park JH, Prausnitz MR (2012) Microneedles for drug and vaccine delivery. Adv Drug Deliv Rev 64(14):1547–1568

    Article  Google Scholar 

  • Moodley N, Ngxamngxa U, Turzyniecka MJ, Pillay TS (2015) Historical perspectives in clinical pathology: a history of glucose measurement. J Clin Pathol 68(4):258–264

    Article  Google Scholar 

  • Niedzwiecki MM, Samant P, Walker DI, Tran V, Jones DP, Prausnitz MR, Miller GW (2018) Human suction blister fluid composition determined using high-resolution metabolomics. Anal Chem 90(6):3786–3792

    Article  Google Scholar 

  • Park EJ, Werner J, Beebe J, Chan S, Smith NB (2009) Non-invasive ultrasonic glucose sensing with large pigs (approximately 200 pounds) using a lightweight cymbal transducer array and biosensors. J Diabetes Sci Technol 3(3):517–523

    Article  Google Scholar 

  • Rhee SY, Chon S, Koh G, Paeng JR, Oh S, Woo JT, Kim SW, Kim JW, Kim YS (2007) Clinical experience of an iontophoresis-based glucose measuring system. J Korean Med Sci 22(1):70–73

    Article  Google Scholar 

  • Sharma S, El-Laboudi A, Reddy M, Jugnee N, Sivasubramaniyam S, El Sharkawy M, Georgiou P, Johnston D, Oliver N, Cass AEG (2018) A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring. Anal Methods 10:2088–2095

    Article  Google Scholar 

  • Shin JJ, Holtzclaw KR, Dangui ND, Kanderian S Jr, Mastrototaro JJ, Hong PI (2005) Real time self-adjusting calibration algorithm, US patent 6,895,263

    Google Scholar 

  • Steil GM, Rebrin K, Hariri F, Jinagonda S, Tadros S, Darwin C, Saad MF (2005) Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia. Diabetologia 48:1833–1840

    Article  Google Scholar 

  • Stylianou S, Kelnar S (2009) The introduction of successful treatment of diabetes mellitus with insulin. J R Soc Med 102(7):298–303

    Article  Google Scholar 

  • The Diabetes Control and Complications Trial Research Group (1996) Lifetime benefits and costs of intensive therapy as practiced in the diabetes control and complications trial. JAMA 276(17):1409–1415

    Article  Google Scholar 

  • Vaddiraju S, Tomazos I, Burgess DJ, Jain FC, Papadimitrakopoulos F (2010) Emerging synergy between nanotechnology and implantable biosensors: a review. Biosens Bioelectron 25(7):1553–1565

    Article  Google Scholar 

  • Van Der Valk PR, Van Der Schatte Olivier-Steding I, Wientjes KJ, Schoonen AJ, Hoogenberg K (2002) Alternative-site blood glucose measurement at the abdomen. Diabetes Care 25:2114–2115

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sanjiv Sharma .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 Springer Science+Business Media, LLC, part of Springer Nature

About this entry

Check for updates. Verify currency and authenticity via CrossMark

Cite this entry

Ghoreishizadeh, S., Sharma, S. (2021). Continuous Glucose Monitoring Sensors for Management of Diabetes. In: Sawan, M. (eds) Handbook of Biochips. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-6623-9_58-1

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-6623-9_58-1

  • Received:

  • Accepted:

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-6623-9

  • Online ISBN: 978-1-4614-6623-9

  • eBook Packages: Springer Reference EngineeringReference Module Computer Science and Engineering

Publish with us

Policies and ethics