Abstract
Flow cytometry is an essential tool for studying the tumor-immune microenvironment. It allows us to quickly quantify and identify multiple cell types in a heterogeneous sample. This chapter provides an overview of the flow cytometry instrumentation and a discussion of the appropriate considerations and steps in building a reproducible flow cytometry staining panel. We present an updated lymphoid tissue and solid tumor-infiltrating leucocyte flow cytometry staining protocol and an example of flow cytometry data analysis.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Pitoiset F, Barbié M, Monneret G et al (2018) A standardized flow cytometry procedure for the monitoring of regulatory T cells in clinical trials. Cytometry B Clin Cytom 94:621–626
Krisna SS, Goncalves C, Gagnon N et al (2021) Optimized protocol for immunophenotyping of melanoma and tumor-bearing skin from mouse. STAR Protoc 2:100627
Sceneay J, Chow MT, Chen A et al (2012) Primary tumor hypoxia recruits CD11b+/Ly6Cmed/Ly6G+ immune suppressor cells and compromises NK cell cytotoxicity in the premetastatic niche. Cancer Res 72:3906–3911
Hulett HR, Bonner WA, Barrett J et al (1969) Cell sorting: automated separation of mammalian cells as a function of intracellular fluorescence. Science 166:747–749
Kamentsky LA, Melamed MR, Derman H (1965) Spectrophotometer: new instrument for ultrarapid cell analysis. Science 150:630–631
Cossarizza A, Chang HD, Radbruch A et al (2021) Guidelines for the use of flow cytometry and cell sorting in immunological studies. Eur J Immunol 51:2708–3145
Park LM, Lannigan J, Jaimes MC (2020) OMIP-069: forty-color full spectrum flow cytometry panel for deep immunophenotyping of major cell subsets in human peripheral blood. Cytometry A 97:1044–1051
Sahir F, Mateo JM, Steinhoff M et al (2020) Development of a 43 color panel for the characterization of conventional and unconventional T-cell subsets, B cells, NK cells, monocytes, dendritic cells, and innate lymphoid cells using spectral flow cytometry. Cytometry A. https://doi.org/10.1002/cyto.a.24288
Ford AL, Foulcher E, Goodsall AL et al (1996) Tissue digestion with dispase substantially reduces lymphocyte and macrophage cell-surface antigen expression. J Immunol Methods 194:71–75
Autengruber A, Gereke M, Hansen G et al (2012) Impact of enzymatic tissue disintegration on the level of surface molecule expression and immune cell function. Eur J Microbiol Immunol (Bp) 2:112–120
Shapiro HM (2005) Practical flow cytometry. Wiley, New York
Hulspas R, Gorman MRG, Wood BL et al (2009) Considerations for the control of background fluorescence in clinical flow cytometry. Cytometry B Clin Cytom 76:355–364
Maecker HT, Frey T, Nomura LE et al (2004) Selecting fluorochrome conjugates for maximum sensitivity. Cytometry A 62:169–173
Hulspas R, Dombkowski D, Preffer F et al (2009) Flow cytometry and the stability of phycoerythrin-tandem dye conjugates. Cytometry A 75:966–972
Roederer M (2001) Spectral compensation for flow cytometry: visualization artifacts, limitations, and caveats. Cytometry 45:194–205
Schmid I, Dagarag M, Hausner MA et al (2002) Simultaneous flow cytometric analysis of two cell surface markers, telomere length, and DNA content. Cytometry 49:96–105
Ferrer-Font L, Small SJ, Lewer B et al (2021) Panel optimization for high-dimensional immunophenotyping assays using full-spectrum flow cytometry. Curr Protoc 1:e222
Kaplan D, Smith D (2000) Enzymatic amplification staining for flow cytometric analysis of cell surface molecules. Cytometry 40:81–85
Perfetto SP, Chattopadhyay PK, Roederer M (2004) Seventeen-colour flow cytometry: unravelling the immune system. Nat Rev Immunol 4:648–655
Boesch M, Cosma A, Sopper S (2018) Flow cytometry: to dump or not to dump. J Immunol 201:1813–1815
Hulspas R (2010) Titration of Fluorochrome-conjugated antibodies for labeling cell surface markers on live cells. Curr Protoc Cytom. Chapter 6:Unit 6.29
Stewart CC, Stewart SJ (2003) Titering antibodies. Wiley, New York
Ferrer-Font L, Pellefigues C, Mayer JU et al (2020) Panel design and optimization for high-dimensional immunophenotyping assays using spectral flow cytometry. Curr Protoc Cytom 92:e70
Niewold P, Ashhurst TM, Smith AL et al (2020) Evaluating spectral cytometry for immune profiling in viral disease. Cytometry A 97:1165–1179
Maecker HT, Trotter J (2006) Flow cytometry controls, instrument setup, and the determination of positivity. Cytometry A 69:1037–1042
Roederer M (2002) Compensation in flow cytometry. Wiley, New York
Herzenberg L, Tung J, Moore W et al (2006) Interpreting flow cytometry data: a guide for the perplexed. Nat Immunol 7:681–685
O’Gorman MR, Thomas J (1999) Isotype controls – time to let go? Cytometry 38:78–80
Holmes K, Lantz LM, Fowlkes BJ et al (2001) Preparation of cells and reagents for flow cytometry. Curr Protoc Immunol. Chapter 5:Unit 5.3
Acknowledgments
This research was funded by the Canadian Institutes of Health Research grant PJT-162260 and the Canadian Cancer Society (grant #707140) to SVDR and by the Leukemia and Lymphoma Society of Canada (grant # 622895) and Cancer Research Society (grant #840423) to KKM.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 The Author(s), under exclusive license to Springer Science+Business Media, LLC, part of Springer Nature
About this protocol
Cite this protocol
Santinon, F., Young, Y.K., del Rincón, S.V., Mann, K.K. (2023). Analyzing the Tumor-Immune Microenvironment by Flow Cytometry. In: Ursini-Siegel, J. (eds) The Tumor Microenvironment. Methods in Molecular Biology, vol 2614. Humana, New York, NY. https://doi.org/10.1007/978-1-0716-2914-7_2
Download citation
DOI: https://doi.org/10.1007/978-1-0716-2914-7_2
Published:
Publisher Name: Humana, New York, NY
Print ISBN: 978-1-0716-2913-0
Online ISBN: 978-1-0716-2914-7
eBook Packages: Springer Protocols