Keywords

Background

Carnitine palmitoyltransferase IA (CPTIA, EC# 2.3.1.21) deficiency is a rare autosomal recessively inherited disorder of the carnitine cycle (MIM #255120) (Bonnefont et al. 2004). This enzyme is essential for transport of long-chain fatty acyl-CoA esters into mitochondria for subsequent beta-oxidation. It is located in the outer mitochondrial membrane and catalyzes the conversion of cytosolic long-chain acyl-CoA esters into their respective acylcarnitine esters. Acylcarnitines are subsequently transported across the inner mitochondrial membrane and reconverted to acyl-CoA thioesters by the actions of carnitine/acylcarnitine translocase (CACT, SLC25A20) and carnitine palmitoyltransferase II (CPTII, EC# 2.3.1.21). Loss of CPT-IA activity diminishes the intra-mitochondrial substrate levels for fatty acid beta-oxidation, thereby impairing energy generation (Bonnefont et al. 2004). Clinical symptoms often appear during periods of prolonged fasting or illness. Life-threatening hypoketotic hypoglycemia, hepatic encephalopathy, hepatomegaly with or without acute liver failure, seizures, and coma are prominent presenting clinical features. Mild cardiomegaly and heart beat disorders may be part of the clinical spectrum, as well as renal tubular acidosis (Bonnefont et al. 2004).

Classically, high plasma concentrations of free carnitine (C0) were considered diagnostic (Bonnefont et al. 2004; Stanley et al. 1992). It became, however, increasingly clear that this diagnostic parameter is problematic and that the diagnosis could be easily overlooked since quite often the concentration of C0 in plasma was found to be normal (Bergman 1994; Bonnefont et al. 2004; Innes et al. 2000; Primassin and Spiekerkoetter 2010; de Sain-van der Velden et al. 2013). It has been suggested that a high concentration of C0 in blood spot is more sensitive than its concentration in plasma (Primassin and Spiekerkoetter 2010; de Sain-van der Velden et al. 2013; Sim et al. 2001). This could be debated. Fingerhut et al. (2001) investigated the concentrations of C0 and acylcarnitines in 6 blood spot samples of 3 patients diagnosed with CPT-IA deficiency (2 days to 12 months old) and compared the results with those of 177,842 samples from the central Bavarian newborn-screening program. Blood spot C0 concentrations were normal in two of three patients. Diagnostic accuracy improved considerably in these patients when the molar ratio of C0/(C16:0-ac+C18:0-ac) was used (Fingerhut et al. 2001). In the most commonly used matrix, i.e., plasma, this ratio might have high sensitivity as well (de Sain-van der Velden et al. 2013). Unfortunately, the specificity of this marker is currently unknown.

To gain insight in the sensitivity ánd specificity of biochemical markers of CPT-IA deficiency, acylcarnitines in plasma of patients with proven CPT-IA deficiency were compared with those of patients in our historical dataset.

Methods

(Acyl-) carnitines in nine plasma samples of four patients with enzymatically and genetically confirmed CPT-IA deficiency were analyzed in three hospital laboratories, using comparable analytical methods. Blood spot acylcarnitines were available for three patients. The plasma results were compared with the historical dataset of 2,190 subjects of whom samples were analyzed in one of our laboratories between 2006 and 2012, (2,194 including the samples of 4 CPT-IA deficient patients). Only analyses of the first sample presented to our laboratories were included. The need for formal ethical review was waived by the local ethics committee. The study design was in accordance with the current revision of the Helsinki Declaration.

Samples were prepared according to local standard operating procedures. In short, plasma was deproteinized with acetonitrile. Subsequently, 6 deuterium-labeled internal standards in methanol/H2O were added and samples were analyzed by flow-injection tandem-mass spectrometry (API-3000, AB Sciex, Framingham, USA). Concentrations of C0 and the individual acylcarnitines were quantitated by multiple reaction monitoring. C0 by an m/z transition of 162->103 and acylcarnitines by selected precursor ions with m/z 85 as the common product ion, as described earlier by Derks et al. (2008). For free carnitine, a daughter-mass with an m/z 103 was chosen because it had a higher intensity than the m/z 85 fragment. Data evaluation was performed with Chemoview® 3.0 software (AB Sciex, Framingham, USA).

Reference values were calculated using a reference population, consisting of 1,600 subjects out of the total population of 2,194 subjects. The other 594 samples derived from subjects diagnosed with an inborn error of metabolism, mainly fatty acid oxidation disorders, organic acidurias, phenylketonuria, glycogen storage diseases, and urea cycle defect, or originated from subjects who underwent a function test, i.e., fasting, glucose tolerance, or exercise tests. Concentrations of C18:1-ac and C16:0-ac are relatively high compared to the other long-chain acylcarnitines (lc-ac) (see, e.g., Table 1). It was decided to study C0, lc-ac (C16:0-, C16:1-, C18:0-, C18:1-, and C18:2-ac), the sum of lc-ac (∑lc-ac), and the molar ratios C0/(C16:0-ac+C18:0-ac) and C0/∑lc-ac. Age-dependency of these biochemical markers was investigated in the reference population by Spearman rank tests (significant p < 0.05). For each established age category, 95% reference intervals were based on 2.5 and 97.5% percentiles (non-Gaussian distributed metabolites). Normality was assessed using Shapiro–Wilk tests (significant p < 0.05). Receiver Operating Characteristic (ROC) curves were generated from results of patients with CPT-IA deficiency versus all (age-matched) subjects in the total cohort. The values of the biochemical markers to diagnose CPT-IA deficiency were compared using the areas under the curve (AUC). Sensitivity and specificity were calculated at 95% reference limits; sensitivity = true positives (TP)/(TP+false negatives (FN)) and specificity = true negatives (TN)/(TN+false positives (FP)). Analyses were done using Excel 2007 and Analyse-it 2008 (Analyse-it software, Ltd).

Table 1 Reference values and ROC analyses for biochemical markers of CPT-IA deficiency

Results

Reference Values and ROC Analysis of Biochemical Markers

Except for C18:1-ac, all markers were significantly age-dependent (Spearman rank P < 0.001), with correlation coefficients (R) between (−) 0.05 for ∑lc-ac and (+) 0.34 for C0. This relation was most significant in the first 30 days of life. Even though age-dependency remained to be significant after 30 days for C0 and C18:0-ac, their relation with age was considered too small to have a relevant effect on calculated reference values (+0.07 μmol/L per year for C0, and +0.0001 μmol/L per year for C18:0-ac (linear regression analyses)). Reference values were calculated for three age-categories: 0–6 days (n = 169), 7–30 days (n = 106), and ≥31 days (n = 1,325) (Table 1). All biomarkers in these subgroups had non-Gaussian distributions (Shapiro–Wilk p < 0.05).

Plasma and blood spot acylcarnitines concentrations and ratios of patients with CPT-IA deficiency are presented in Table 2. All nine plasma samples had normal concentrations of C0, whereas all had low C18:0-ac, C18:1-ac, and ∑lc-ac concentrations, and high molar ratios. The ROC curves, and the sensitivity and specificity using 95% reference limits are also presented in Table 1. Because all samples of CPT-IA deficient patients were obtained after 30 days of age, only subjects and patients ≥31 days of age were included (n = 1,803/2,194). AUC were highest for C18:1-ac, C18:0-ac, and ∑lc-ac, closely followed by C0/∑lc-ac. Using 95% reference limits, C18:1-ac <0.05 μmol/L had the highest diagnostic value with a sensitivity of 100% and a specificity of 97.4%. Values were slightly less for other lc-ac and ratios, see Table 1. The ratio C0/(C16:0-ac+C18:0-ac) had slightly better specificity at these cut-off values compared to C0/∑lc-ac.

Table 2 Biochemical marker concentrations of 4 CPT-IA deficient patients

Using a combination of two markers, i.e., a concentration in plasma of C18:1-ac <0.05 μmol/L and a molar ratio of C0/(C16:0-ac+C18:0-ac) >587, specificity to diagnose CPT-IA deficiency increased to 99.3% compared with either C18:1-ac (97.4%) or C0/(C16:0-ac+C18:0-ac) (96.9%) alone, all at a sensitivity of 100%.

Characteristics of Subjects with False-Positives Test Results

Figure 1 shows the values of the 2 biochemical markers: C18:1-ac and C0/(C16:0-ac+C18:0-ac) for all subjects and patients ≥31 days of age, including 5 follow-up samples of CPT-IA deficient patients. Forty-eight subjects had false-positive test results for C18:1-ac. Ten of them were diagnosed with an inborn error of metabolism other than CPT-IA deficiency, i.e., phenylketonuria (n = 4), medium chain acyl-CoA dehydrogenase (MCAD) deficiency (n = 4), biotinidase deficiency (n = 1), and molybdenum cofactor deficiency (n = 1). Two out of four patients with MCAD deficiency and the patient with biotinidase deficiency had low concentrations of the sum of all carnitine-containing species in plasma (total carnitine). Six patients without a diagnosis also had low total carnitine concentrations. None of the 48 subjects had a high total carnitine concentration.

Fig. 1
figure 1

Presents the results of C18:1-ac versus C0/(C16:0-ac+C18:0-ac) of all subjects and patients ≥31 days of age, including the first (circles) and follow-up (triangles) samples of four patients with CPT-IA deficiency [n = 1,808 (1,803 + 5 follow-up samples)]. The numbers correspond to the case numbers presented in Table 2. The dashed lines indicate the 95% cut-off limits for C18:1-ac (0.05 μmol/L) and C0/(C16:0-ac+C18:0-ac) (587). The quadrant limited by C18:1-ac <0.05 μmol/L and C0/(C16:0-ac+C18:0-ac) >587 had a sensitivity of 100% and a specificity of 99.3% for diagnosis of CPT-IA deficiency in our study population

Fifty-six subjects out of the total population had a false-positive test results for the molar ratio C0/(C16:0-ac+C18:0-ac). Nineteen of them were diagnosed with an inborn error of metabolism other than CPT-IA deficiency, i.e., phenylketonuria (n = 11), glycogen storage disease 1A (n = 2), multiple acyl-CoA dehydrogenase deficiency (n = 1), MCAD deficiency (n = 1), molybdenum cofactor deficiency (n = 1), Smith–Lemli–Opitz syndrome (n = 1), pyruvate dehydrogenase deficiency (n = 1), and OCTN2 deficiency (n = 1). The MCAD deficient patient and ten subjects without a diagnosis had plasma total carnitine concentrations above the 95% percentile of their reference age group. None of the 56 subjects had a low total carnitine concentration in plasma.

Twelve patients had a false-positive test result when using the combination of a low C18:1-ac and a high molar ratio of C0/(C16:0-ac+C18:0-ac), of whom three had phenylketonuria and one had molybdenum cofactor deficiency. Of the other eight subjects, one was clinically suspected to suffer from CPT-IA deficiency. This was ruled out by CPT-IA enzyme activity measurements. All patients and subjects had a normal concentration of total carnitine.

Biochemical Markers of CPT-IA Deficiency in Neonatal Blood Spot

Acylcarnitine profiles were analyzed in blood spots obtained at the time of presentation in three of our patients with CPT-IA deficiency (cases 2–4). In these patients, C0 concentrations were above 197 μmol/L, whereas all lc-ac concentrations were below 0.02 μmol/L (Table 2). For case 1 the neonatal blood spot was requested at the Dutch neonatal screening authority. In this bloodspot, the concentration of C0 was found to be >100 μmol/L. In controls, C0 concentrations are lower and lc-ac concentrations are higher in blood spots compared to plasma (de Sain-van der Velden et al. 2013). This implies that these values are highly abnormal, even when applying plasma reference values.

Discussion

The results clearly show that CPT-IA deficiency can easily be overlooked when using the classical biomarker, i.e., high concentrations of C0 in plasma, as the sole criterion for diagnosis, as previously reported (Bergman 1994; Bonnefont et al. 2004; Innes et al. 2000; Primassin and Spiekerkoetter 2010; de Sain-van der Velden et al. 2013). Blood spot acylcarnitines, in particular the ratio of C0/(C16:0-ac+C18:0-ac), seem to have high diagnostic value for CPT-IA deficiency (Fingerhut et al. 2001; McHugh et al. 2011; Primassin and Spiekerkoetter 2010; de Sain-van der Velden et al. 2013; Sim et al. 2001). Even though our data support this suggestion, the present study also demonstrates that plasma, the more commonly used matrix, can be used for this purpose as well. The current study confirmed the high sensitivity of the molar ratio of C0/(C16:0-ac+C18:0-ac) in plasma, as proposed earlier (de Sain-van der Velden et al. 2013). Sensitivity of low plasma lc-ac concentrations was, however, equally high. When taking specificity under consideration, the diagnostic value became much better when using the combination of a high molar ratio of C0/(C16:0-ac+C18:0-ac) >587 mol/mol ánd a low C18:1-ac <0.05 μmol/L (cut-offs for patients ≥31 days of age). For low prevalent diseases such as CPT-IA deficiency, the increase of specificity from 97 to 99% has a dramatic effect on the positive predictive value of a test. In our selected population with a prevalence of 0.0018 (4/2,194), the positive predicted value increases from 7 to 25%.

ROC curve analysis is a well-known tool to compare diagnostic values of biomarkers. Using this analysis (Table 1), plasma C18:0-ac, C18:1-ac, and ∑lc-ac had highest and similar diagnostic values (AUC 1.000), closely followed by C0/∑lc-ac (AUC 0.999). To reduce the chance of missing a CPT-IA deficient patient, fixed cut-off values based on 95% reference values were evaluated. Using these cut-offs, the molar ratio C0/∑lc-ac was equally sensitive, but slightly less specific than the originally proposed molar ratio, i.e., C0/(C16:0-ac+C18:0-ac). False-positive results for C0/(C16:0-ac + C18:0-ac) were explained by high total carnitine concentrations in 11 of 56 patients and subjects. On the other hand, low C18:1-ac concentrations were associated with low total carnitine concentrations in 9 of 48 patients. Combining both markers significantly diminished the number of false positives, partly due to low or high carnitine concentrations. False-positive results were not clearly associated with other (known) inborn errors of metabolism. Three patients with phenylketonuria (3/100 in this cohort) had low C18:1-ac concentrations in combination with high C0/(C16:0-ac+C18:0-ac) ratios. After reviewing other acylcarnitine profiles of the three patients, only one sample, i.e., the first sample, had this remarkable result. The reason for this is unknown.

An important limitation of this study is the relatively low number of patients with CPT-IA deficiency. Plasma acylcarnitines have high intra-individual biological variation, depending on nutritional status (fasting), exercise, and clinical condition. The large biological variation may impair the diagnostic value of the markers. This is illustrated by the results of case 3. The analysis of the first sample gave near-normal values of the molar ratios of C0/(C16:0-ac+C18:0-ac) and C0/∑lc-ac, whereas the analysis of the second sample gave clearly abnormal values, see Table 2. When reviewing all nine plasma samples of our CPT-IA deficient patients (see Table 2 and Fig. 1), it is clear that the suggested cut-off values are highly sensitive and that the diagnostic value of the (combination of) markers is not dependent on the clinical condition and treatment regimens of our patients. When reviewing six plasma C0 concentrations and C0/(C16:0-ac+C18:0-ac) ratios of the 2 CPT-IA deficient patients presented in the study of de Sain-van der Velden et al. (2013), all the samples of these patients would probably also have been identified using the proposed marker combination. It is nevertheless important to investigate these markers in a larger cohort of CPT-IA deficient patients.

Conclusion

CPT-IA deficiency is rare and can easily be overlooked by relying on the classical marker, i.e., high plasma C0 concentrations. It has therefore been suggested to use blood spots acylcarnitines for diagnosis of CPT-IA deficiency. This study, however, demonstrates that CPT-IA deficiency can be diagnosed reliably with high sensitivity and specificity in plasma by a combination of a low C18:1-ac concentration and a high molar ratio of C0/(C16:0-ac+C18:0-ac). It is advised to further validate these markers in a larger cohort of patients with CPT-IA deficiency.