Introduction

A variety of rare inherited inborn errors related to (6R)-5,6,7,8-tetrahydrobiopterin (BH4) metabolism have been described, often referred to as pediatric neurotransmitter disease. These disorders may be associated with or without hyperphenylalaninemia (HPA) and can lead to low or decreased homovanillic acid and 5-hydroxyindoleacetic acid (Blau et al. 2001; Fig. 1). Some BH4 disorders are detected by neonatal newborn screening since they present with HPA and are caused by enzyme deficiencies of guanosine triphosphate cyclohydrolase (GTPCH, OMIM 600225; MIM 233910; EC 3.5.4.16)-autosomal recessive form (Niederwieser 1984), pterin-4-α-carbinolamine dehydratase (PCD, OMIM 126090; EC 4.2.1.96) (Thöny et al. 1998), 6-pyruvoyl-tetrahydropterin synthase (PTPS, OMIM 261640; EC 4.2.3.12), and dihydropteridine reductase (DHPR, OMIM 261630; EC 1.5.1.34) (Kaufman et al. 1975). The neurological symptoms associated with these disorders can vary and include mental disability, convulsions, dystonia, oculogyric crises, drowsiness, irritability, and swallowing difficulties. However, other inborn errors of pterin metabolism that do not present with HPA have been described and include GTPCH-autosomal dominant form (MIM 128230), initially described as Segawa disease (Segawa et al. 1976) and sepiapterin reductase (SR, OMIM 182125; EC 1.1.1.153) deficiency (Bonafe et al. 2001). Initial screening for these defects relies on analysis of pterins and monoamine neurotransmitter metabolites in cerebrospinal fluid (CSF).

Fig. 1
figure 1

Pterin and monoamine metabolism. Abbreviations: GTP guanosine triphosphate, GTPCH GTP cyclohydrolase, PTPS 6-pyruvoyl-tetrahydropterin synthase, SR sepiapterin reductase, BH4 (6R,S)-5,6,7,8-tetrahydrobiopterin, BH2 7,8-dihydrobiopterin, DHPR dihydropteridine reductase, PCD pterin-4-α-carbinolamine dehydratase, CR carbonyl reductase, DHFR dihydrofolate reductase, qBH2 quinine-dihydrobiopterin, TH tyrosine hydroxylase, TPH tryptophan hydroxylase, PAH phenylalanine hydroxylase, AADC aromatic amino acid decarboxylase, L-DOPA L-3,4-dihydroxyphenylalanine, 5-HTP 5-hydroxytryptophan, 3-OMD 3-o-methyldopa, DA dopamine, 5-HT serotonin, HVA homovanillic acid, 5-HIAA 5-hydroxyindoleacetic acid

Numerous methodologies have been employed to determine pteridines, including radioenzymatic assay (Guroff et al. 1967), radioimmunoassay (Nagatsu et al. 1981), HPLC with fluorescence (Stea et al. 1979; Fukushima and Nixon 1980a), HPLC with electrochemistry (Lunte and Kissinger 1983; Bräutigam et al. 1982), and HPLC or UPLC with electrochemistry and fluorescence (Hyland 1985; Guibal et al. 2014). One of the first HPLC methods developed relied on the highly fluorescent characteristics of the fully oxidized pteridines and the differential oxidation of reduced biopterin states (Fukushima and Nixon 1980b; Fukushima et al 1978). This allowed an indirect method of detecting both BH4 and 7,8-dihydrobiopterin (BH2) through the measurement of total biopterin. This method has been applied to detect BH4 and BH2 in tissues, urine, plasma, and dried blood spots (Schmidt et al. 2006; Antonozzi et al. 1988).

We here describe a method using stable isotope dilution liquid chromatography tandem mass spectrometry (LC-MS/MS) to quantitate BH4, BH2, neopterin, and sepiapterin in CSF that can be applied as a screening method for the differentiation of inborn errors of pterin metabolism.

Materials and Methods

Standards and 15N-labeled stable isotope internal standards, BH4, BH2, neopterin, sepiapterin, 15N-BH4, 15N-BH2, and 15N-neopterin, were obtained from Schircks Laboratories (Switzerland). Formic acid, heptafluorobutyric acid, ammonium acetate, and dithiothreitol (DTT) were obtained from Fluka and Optima LC-MS grade methanol from Fisher Scientific. Diethylenetriaminepentaacetic acid (DETAPAC) was purchased from Sigma. Stock standards for each pterin metabolite and internal standard were prepared as 1 mmol/L solutions in water containing 0.2% DTT and stored at −80°C. Microtiter plates used for were purchased from NUNC.

Sample Collection

CSF samples were collected in CSF collection kits provided by the neuropharmacology laboratory at the Baylor Research Institute. Specimens used for accuracy validation of CSF BH4 and neopterin were performed on tube #3 of 5 which contained DTT and DETAPAC. After collection, samples were frozen and shipped by overnight courier on dry ice and are stored at −80°C until analysis. Blood-contaminated CSF samples are rejected, since hemoglobin from erythrocytes may cause auto-oxidation of pterins. This can be avoided by centrifuging prior to freezing, and the clear CSF transferred to another vial and frozen.

Analysis of Amine Neurotransmitters in CSF

CSF amine neurotransmitters were analyzed by HPLC with electrochemical detection by a previously published method (Hyland et al. 1986).

Analysis of BH4 and Neopterin in CSF by HPLC with Electrochemical and Fluorescence

CSF BH4 and neopterin were analyzed by HPLC with electrochemical and fluorescence detection by a previously published method (Hyland 1985).

Analysis of BH4, BH2, Sepiapterin, and Neopterin in CSF by LC-MS/MS

Sample Preparation

The calibration curve was prepared in water containing 0.2% DTT over a range of 3 to 200 nmol/L for each pterin analyte. Internal standard concentrations of 15N-BH4, 15N-BH2, and 15N-neopterin were prepared in water containing 0.2% DTT at a final concentration of 100 nmol/L each. Sample preparation for CSF pterin analysis consisted of combining 210 μL of 100 nmol/L internal standard solution with 30 μL of blank, standard, control, or sample in 1.5 mL Eppendorf tubes, mixed by vortex and loaded in a microtiter plate for analysis.

LC-MS/MS

The LC-MS/MS analysis was performed on an AB Sciex 5500QTRAP mass spectrometer (Foster City, CA, USA) coupled with a Shimadzu ultrahigh pressure Nexera chromatograph system (Kyoto, Japan). Nitrogen gas was supplied by an AB-3G gas generator (Peak Scientific) and was used as the drying, nebulizing, curtain, and collision gas. The MS/MS experiments were performed under positive electrospray ionization (+ESI) with multiple-reaction monitoring (MRM) using a Turbolon Spray electrospray source operating at a voltage of 1.1 kV and desolvation temperature of 700°C. All pterin standards exhibited intense protonated molecular ions under + ESI conditions. The parameters for ion selection and collision-activated fragmentation of the molecular ions of pterin standards and 15N-labeled isotopes were optimized by continuous infusion of pure compounds (1 μmol/L) at a flow rate of 10 μL/min. The selected precursor and fragment ions used for the measurement of unlabeled and labeled pterins are summarized in Table 1. The mass spectrometer was operated under unit resolution. The LC-MS/MS data was acquired and processed using Analyst 1.5.2 software (AB Sciex).

Table 1 MS/MS parameters of pterins and internal standards (declustering potential (DP); collision energy (CE); and collision exit potential (CXP))

Liquid chromatography was performed on a Shimadzu Nexera system by reversed-phase HPLC (EZfaast 250 × 2 mm 4 μm AAA-MS column, with a 4 × 2 mm SecurityGuard column, Phenomenex, CA, USA) equilibrated at 40°C. The system consisted of a binary gradient: Eluent A (water containing 0.1% formic acid and 0.1% heptafluorobutyric acid) and Eluent B (methanol containing 0.1% formic acid). The flow rate was 0.20 mL/min, and 10 μL of processed sample was injected for analysis. The LC gradient was optimized to retain the pterin compounds on the column while eluting ion-suppressing moieties. The initial composition of the gradient was 95% A and increased linearly to 25% A during the first 4 min. The concentration of Eluent B was increased to 100% at 4.1 min and held until 5.0 min. At 5.1 min eluents were returned to initial conditions for equilibration. Total analytical analysis, including column re-equilibration, was 10 minutes. Eluent flow from the column was diverted to waste at the beginning and end of each run and was only directed to the source for the period from 5.0 to 7.5 min.

Assay Validation (Precision, Accuracy, and Recovery)

The method was validated by investigation of linearity, method precision studies (intra- and inter-day), accuracy, detection limit, and recovery. CSF was spiked with external pterin standards to produce a bi-level quality control (QC) used for both intra- and inter-day precision studies. Intraday precision (n = 10) was evaluated by analysis of bi-level QC material acquired within a single analytical run. Inter-day precision (n = 20) was evaluated by repeated analysis of bi-level QC material analyzed in duplicate over a period of 20 different days. Precision was determined as the relative standard deviation (RSD %). Recovery of pterins was performed by spiking CSF with water, 50 or 200 nM of each analyte. Determination of accuracy was performed only for BH4 and neopterin by comparing results obtained by HPLC with electrochemical and fluorescence detection currently used in our laboratory for these metabolites only.

Results

The collision-induced dissociation spectra of the protonated molecular ions of each pterin standard are given in Fig. 2. Representative chromatograms for the analytes in CSF are also shown in Fig. 2. The precursor-product transitions for each analyte and internal standard are shown: m/z 242.2 → 166.0 (BH4), 240.1 → 164.9 (BH2), 254.1 → 206.1 (neopterin), 238.1 → 165.1 (sepiapterin), 243.1 → 167.0 (15N-BH4), 241.1 → 197.0 (15N-BH2), and 255.1 → 206.1 (15N-neopterin) (Table 1). Monitoring of a second transition was not possible because there were no other unique fragments of significant intensity. In order to minimize ion suppression, this LC method was developed to retain analytes and internal standards later in chromatographic run. In preliminary ESI both positive mode and negative mode were tested. Positive ESI produced greater signal intensity for all analytes.

Fig. 2
figure 2

Product ion spectra of each pterin and a representative chromatograph of each metabolite in CSF. (a, BH4 = 51 nM; b, BH2 = 39 nM; c, neopterin = 20 nM; and d, sepiapterin = 23 nM). Spectra were generated with + ESI-MS/MS by infusion (10 μL/min) of pure standards (1 μM/L each)

Assay Performance and Validation

Linear regression analysis showed linearity for all analytes over their calibration range (data not shown). The calibration curves for BH4, BH2, sepiapterin, and neopterin were linear over a concentration range of 3 to 200 nmol/L. Intra-assay precision (n = 10) was assessed in spiked bi-level CSF with coefficient of variation (CVs) for all analytes <6% (Table 2). The inter-assay precision (n = 20) was assessed by analysis of duplicates of bi-level quality controls over a period of 20 different days. The CVs for BH4, BH2, and neopterin were <10% (Table 2). The inter-assay precision for sepiapterin was higher than the other pterins since 15N-BH2 was used as the internal standard since labeled sepiapterin is unavailable (Table 2). Recovery of 50 and 200 nM spikes of BH4, BH2, and neopterin ranged from 98 to 112%, whereas recovery for sepiapterin was 85 to 75% (data not shown).

Table 2 Assay precision, linearity, and limit of detection (LOD)

Method Comparison (BH4 and Neopterin)

Accuracy of the LC-MS/MS method was determined by comparing BH4 and neopterin concentrations in CSF to values obtained by HPLC with electrochemical and fluorescence detection (Hyland 1985). CSF neopterin could not be directly compared between the two methods due to the electrochemical cell oxidizing reduced forms of neopterin completely to neopterin. The LC-MS/MS method only detects native oxidized neopterin and not any of the reduced forms. In order to obtain native oxidized neopterin on the HPLC with electrochemical and fluorescence method, the electrochemical cell was switched off, and this allowed only the native oxidized neopterin present in the CSF to be quantified by fluorescence. Method comparison data of BH4 (HPLC with electrochemical and LC-MS/MS) and neopterin (HPLC fluorescence and LC-MS/MS) is shown in Fig. 3.

Fig. 3
figure 3

Pearson correlation coefficients (95% CLs) for BH4 and neopterin (a and b) were r = 0.9646 (0.9240, 0.9837) and r = 0.9919 (0.972, 0.998)%, respectively. Deming regression analysis for BH4 (a) yielded an intercept (95% CLs) of 1.05 (−1.16, 1.65) nmol/L and a 1/slope of 0.9397; neopterin (b) yielded an intercept of (95% CLs) of −7.17 (−2.86, −11.48) nmol/L and a 1/slope of 0.9539. Bland–Altman proportional bias analyses (c and d) relative bias (95% CLs) for BH4 and neopterin were −1.6 (4.1, −7.4)% and −2.9 (18.8, −24.5)%, respectively. All data expressed as nmol/L

Analysis of Pterins in Known Cases of BH4 Deficiencies

CSF specimens from subjects with pterin enzyme deficiencies, confirmed by genomic DNA analysis, having GTPCH-autosomal dominant PTPS, SR, and DHPR, were analyzed by LC-MS/MS. Pterin metabolite results for each specific enzyme deficiency, with data on monoamine neurotransmitter metabolites, are shown in Table 3. In some cases CSF samples were obtained either prior to treatment or following L-dopa therapy. As expected low BH4 levels were detected in subjects with GTPCH-autosomal dominant form and PTPS, whereas BH2 levels were elevated in patients with SR and DHPR deficiency. Elevated concentrations of sepiapterin were detected in two patients with SR deficiency and were undetectable (<1 nmol/L) in the other pterin disorders. Sepiapterin was undetectable in CSF from other subjects (n = 20) without any defects in pterin metabolism and having monoamine metabolite concentrations within the normal reference range (data not shown). The patient with PTPS deficiency presented with an increase in neopterin and with decreased BH4 and BH2 concentrations in CSF.

Table 3 Differentiation of pterin defects through LC-MS/MS analysis

Discussion

An LC-MS/MS method was developed and validated for the simultaneous determination of four important pterin metabolites in CSF BH4, BH2, neopterin, and sepiapterin. The sample preparation procedure was optimized for increased accuracy and ease of use as a screening procedure for defects in pterin metabolism, which lead to pediatric neurotransmitter diseases. This method was further validated by analysis of CSF from subjects with known defects in pterin metabolism. Results showed the expected pattern of changes in pterin metabolites in subjects (Table 3) with defects in GTPCH-autosomal dominant (low BH4 and low BH2), SR (increased sepiapterin, increased BH2, and normal BH4), PTPS (increased neopterin, low BH4, and low BH2), and DHPR (increased BH2). Detection of neopterin is limited to native oxidized neopterin, which may not be reliable to discriminate GTPCH-autosomal dominant cases. However, elevated levels can distinguish patients that have PTPS deficiency or in cases of macrophage activation due to infection and inflammation.

Previous reports in which metabolites were measured in subjects with suspected disorders of pterin metabolism have relied on either multiple analytical analyses or differential oxidation of BH4 and BH2 to obtain a more complete understanding of the state of pterin synthesis. For example, shortly after the discovery of SR deficiency resulting in decreased BH4 metabolism (Bonafe et al. 2001), a HPLC-fluorescence method was reported to measure sepiapterin alone in CSF of patients suspected of having this disorder (Zorzi et al. 2002). Two recently published methods demonstrated the utility of LC-MS/MS for the determination of pterins (Fismen et al 2012; Kim et al 2012). The study by Fismen et al. (2012) first described the use of 15N-labeled stable isotopes to quantify different oxidative states of biopterin forms without differential oxidation. However, these pterins were only measured in human umbilical vein endothelial cells and did not include sepiapterin and neopterin. The study by Kim et al. (2012) described the quantitative analysis of BH4 and dopamine in rat brain extracts only, using LC-MS/MS and stable isotopes as internal standards.

The LC-MS/MS method described in this study is rapid and precise and requires minimal sample preparation for the analysis of CSF samples The high sensitivity provided by positive ESI LC-MS/MS eliminates the need for derivatization, and the HPLC separation is sufficient to avoid the analytes of interest co-eluting with matrix components that can cause ion suppression. The ability to quantitate BH4, BH2, sepiapterin, and neopterin in a single method will allow differentiation of pterin defects, particularly identifying those with DHPR and SR deficiency from other pterin defects (GTPCH and PTPS), by detecting elevated BH2 and the presence of sepiapterin in the case of SR deficiency. The pterin metabolite profile provided by this method will be beneficial in ascertaining the specific pterin defect involved and the correct course for follow-up testing. This method offers a significant improvement in screening patients and will lead to prompt diagnosis and management of inborn errors of pterin metabolism as well as therapeutic monitoring.